• Title/Summary/Keyword: Early Complication

Search Result 616, Processing Time 0.028 seconds

Reconstruction plates used in the surgery for mandibular discontinuity defect

  • Seol, Guk-Jin;Jeon, Eun-Gyu;Lee, Jong-Sung;Choi, So-Young;Kim, Jin-Wook;Kwon, Tae-Geon;Paeng, Jun-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.6
    • /
    • pp.266-271
    • /
    • 2014
  • Objectives: The purpose of this study was to analyze the survival rate of reconstruction plates that were used to correct mandibular discontinuity defects. Materials and Methods: We analyzed clinical and radiological data of 36 patients. Only discontinuous mandibular defect cases were included in the study. Reconstruction plate survival rate was analyzed according to age, gender, location of defect, defect size, and whether the patient underwent a bone graft procedure, coronoidectomy, and/or postoperative radiation therapy (RT). Results: Plate-related complications developed in 8 patients, 7 of which underwent plate removal. No significant differences were found in plate survival rate according to age, gender, location of defect, defect size, or whether a bone graft procedure was performed. However, there were differences in the plate survival rate that depended on whether the patient underwent coronoidectomy or postoperative RT. In the early stages ($9.25{\pm}5.10months$), plate fracture was the most common complication, but in the later stages ($35.75{\pm}17.00months$), screw loosening was the most common complication. Conclusion: It is important to establish the time-related risk of complications such as plate fracture or screw loosening. Coronoidectomy should be considered in most cases to prevent complications. Postoperative RT can affect the survival rate and hazard rate after a reconstruction plate is fitted.

Intracorporeal Anastomosis Using Linear Stapler in Laparoscopic Distal Gastrectomy: Comparison between Gastroduodenostomy and Gastrojejunostomy

  • Lee, Hak-Woo;Kim, Hyoung-Il;An, Ji-Yeong;Cheong, Jae-Ho;Lee, Kang-Young;Hyung, Woo-Jin;Noh, Sung-Hoon
    • Journal of Gastric Cancer
    • /
    • v.11 no.4
    • /
    • pp.212-218
    • /
    • 2011
  • Purpose: Intracorporeal anastomosis during laparoscopic gastrectomy is becoming increasingly prevalent. However, selection of the anastomosis method after laparoscopic distal gastrectomy is equivocal because of a lack of technical feasibility and safety. We compared intracorporeal gastroduodenostomy with gastrojejunostomy using linear staplers to evaluate the technical feasibility and safety of intracorporeal anastomoses as well as its' minimally invasiveness. Materials and Methods: Retrospective analyses of a prospectively collected database for gastric cancer revealed 47 gastric cancer patients who underwent laparoscopic distal gastrectomy with either intracorporeal gastroduodenostomy or gastrojejunostomy from March 2011 to June 2011. Perioperative outcomes such as operation time, postoperative complication, and hospital stay were compared according to the type of anastomosis. Postoperative inflammatory response was also compared between the two groups using white blood cell count and high sensitivity C-reactive protein. Results: Among the 47 patients, 26 patients received gastroduodenostomy, whereas 21 patients received gastrojejunostomy without open conversion or additional mini-laparotomy incision. There was no difference in mean operation time, blood loss, and length of postoperative hospital stays. There was no statistically significant difference in postoperative complication or mortality between two groups. However, significantly more staplers were used for gastroduodenostomy than for gastrojejunostomy (n=6) than for gastroduodenostomy and (n=5). Conclusions: Intracorporeal anastomosis during laparoscopic gastrectomy using linear stapler, either gastroduodenostomy or gastrojejunostomy, shows comparable and acceptable early postoperative outcomes and are safe and feasible. Therefore, surgeons may choose either anastomosis method as long as oncological safety is guaranteed.

Pylorus-Preserving Gastrectomy for Gastric Cancer

  • Oh, Seung-Young;Lee, Hyuk-Joon;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.16 no.2
    • /
    • pp.63-71
    • /
    • 2016
  • Pylorus-preserving gastrectomy (PPG) is a function-preserving surgery for the treatment of early gastric cancer (EGC), aiming to decrease the complication rate and improve postoperative quality of life. According to the Japanese gastric cancer treatment guidelines, PPG can be performed for cT1N0M0 gastric cancer located in the middle-third of the stomach, at least 4.0 cm away from the pylorus. Although the length of the antral cuff gradually increased, from 1.5 cm during the initial use of the procedure to 3.0 cm currently, its optimal length still remains unclear. Standard procedures for the preservation of pyloric function, infra-pyloric vessels, and hepatic branch of the vagus nerve, make PPG technically more difficult and raise concerns about incomplete lymph node dissection. The short- and long-term oncological and survival outcomes of PPG were comparable to those for distal gastrectomy, but with several advantages such as a lower incidence of dumping syndrome, bile reflux, and gallstone formation, and improved nutritional status. Gastric stasis, a typical complication of PPG, can be effectively treated by balloon dilatation and stent insertion. Robot-assisted pylorus-preserving gastrectomy is feasible for EGC in the middle-third of the stomach in terms of the short-term clinical outcome. However, any benefits over laparoscopy-assisted PPG (LAPPG) from the patient's perspective have not yet been proven. An ongoing Korean multicenter randomized controlled trial (KLASS-04), which compares LAPPG and laparoscopy-assisted distal gastrectomy for EGC in the middle-third of the stomach, may provide more clear evidence about the advantages and oncologic safety of PPG.

Linear-Shaped Gastroduodenostomy in Totally Laparoscopic Distal Gastrectomy

  • Son, Hyaung-Mi;Lee, Sang-Lim;Hur, Hoon;Cho, Yong-Kwan;Han, Sang-Uk
    • Journal of Gastric Cancer
    • /
    • v.10 no.2
    • /
    • pp.69-74
    • /
    • 2010
  • Purpose: Laparoscopic gastrectomy has been common treatment modality for gastric cancer. But, most surgeons tend to perform laparoscopy-assisted distal gastrectomy using epigastric incision. Delta-shaped anastomosis is known as intracorporeal gastroduodenostomy, but it is technically difficult and needed many staplers. So we tried to find simple and economical method, here we report on the results of liner-shaped gastroduodenostomy in totally laparoscopic distal gastrectomy. Materials and Methods: We retrospectively reviewed the medical records of 25 patients who underwent totally laparoscopic distal gastrectomy using liner-shaped anastomosis at School of Medicine, Ajou University between January to October 2009. The indication was early gastric cancer as diagnosed by preoperative workup, the anastomoses were performed by using laparoscopic linear stapler. Results: There were 12 female and 13 male patients with a mean age of $55.6{\pm}11.2$. The following procedures were performed 14 laparoscopic gastrectomies, 11 robotic gastrectomies. The mean operation time was $179.5{\pm}27.4$ minutes, the mean anastomotic time was $17.5{\pm}3.4$ minutes. The mean number of stapler cartridges was $5.6{\pm}0.8$. Postoperative complication occurred in one patient, anastomotic stenosis, and the patient required reoperation to gastrojejunostomy. The mean length of postoperative hospital stay was $6.7{\pm}1.0$ days except the complication case, and there was no case of conversion to open procedure and postoperative mortality. Conclusions: Linear-shaped gastroduodenostomy in totally laparoscopic distal gastrectomy is technically simple and feasible method.

Delayed Retrobulbar Hemorrhage after Orbital Floor Reconstruction (안와하벽재건술 후 발생한 지연성 눈뒤출혈: 증례보고)

  • Lee, Seung-Woo;Choi, Young-Woong;Nam, Sang-Hyun;Kim, Hoon
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.489-491
    • /
    • 2010
  • Purpose: Retrobulbar hemorrhage is a rare complication followed by blepharoplasty, trauma, orbital reconstruction, and so on. Most of the cases occur within 24 hours, half of them in the first 6 hours. Some authors have reported delayed retrobulbar hemorrhage after blepharoplasty and trauma within 1 day to 9 days. However, there have been few reports of delayed retrobulbar hemorrhage resulting from the complication of orbital reconstruction. Methods: A 22-year-old male underwent orbital floor reconstruction due to the orbital floor fracture. In 84 hours after the surgery, he complained sudden onset orbital pain and decreased visual acuity immediately after defecation. Intraocular pressure was unmeasurable due to the swelling at that time. Emergency computed tomography was performed. Results: Computed tomography revealed subperiosteal hematoma on inferior orbital wall extended to the apex. Emergency decompressive surgery was performed within 1 hour. After evacuation of hematoma, orbital symptom was improved and visual acuity was restored. Conclusion: Delayed retrobulbar hemorrhage is rare but vision-threatening. Therefore early diagnosis and treatment of delayed retrobulbar hemorrhage is thought to be crucial. The cause of delayed hemorrhage was not clear, however, valsalva maneuver might be the cause of hemorrhage.

Outcomes of transcatheter closure of ductus arteriosus in infants less than 6 months of age: a single-center experience

  • Choi, Gwang-Jun;Song, Jinyoung;Kim, Yi-Seul;Lee, Heirim;Huh, June;Kang, I-Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.12
    • /
    • pp.397-402
    • /
    • 2018
  • Purpose: Transcatheter device closure of patent ductus arteriosus (PDA) is challenging in early infancy. We evaluated PDA closure in infants less than 6 months old. Methods: We performed a retrospective review of infants less than 6 months of age who underwent attempted transcatheter device closure in our institution since 2004. To compare clinical outcomes between age groups, infants aged 6-12 months in the same study period were reviewed. Results: A total of 22 patients underwent transcatheter PDA closure during the study period. Patient mean age was $3.3{\pm}1.5months$, and weight was $5.7{\pm}1.3kg$. The duct diameter at the narrowest point was $3.0{\pm}0.8mm$ as measured by angiography. The most common duct type was C in the Krichenko classification. Procedural success was achieved in 19 patients (86.3%). Major complications occurred in 5 patients (22.7%), including device embolization (n=1), acquired aortic coarctation (n=2), access-related vascular injury requiring surgery (n=1), and acute deterioration requiring intubation during the procedure (n=1). Two patients had minor complications (9.1%). Twenty-four infants aged 6-12 months received transcatheter device closure. The procedural success rate was 100%, and there were no major complications. The major complication rate was significantly higher in the group less than 6 months of age (P=0.045). There was a trend toward increased major complication and procedural failure rates in the younger age group (P<0.01). Conclusion: A relatively higher incidence of major complications was observed in infants less than 6 months of age. The decision regarding treatment modality should be individualized.

Novel Clean End-to-End Anastomosis Method, Without Opening the Stomach Lumen, in Totally Laparoscopic or Robotic Pylorus-Preserving Gastrectomy

  • Takashi Mitsui;Kazuyuki Saito;Yuhei Hakozaki;Yoshiyuki Miwa;Takuji Noro;Emiko Takeshita;Taizen Urahashi;Yasuyuki Seto;Takashi Okuyama;Hideyuki Yoshitomi
    • Journal of Gastric Cancer
    • /
    • v.23 no.4
    • /
    • pp.523-534
    • /
    • 2023
  • Purpose: Intra-abdominal infection is a common postoperative complication of laparoscopic pylorus-preserving gastrectomies (PPGs). Many studies have reported that intra-abdominal infectious complications after gastrectomy adversely affect patient survival outcomes. To prevent gastric fluid leakage into the abdominal cavity, we developed a novel anastomosis method in which the stomach lumen is not opened (termed the non-opened clean end-to-end anastomosis method [NoCEAM]) and evaluated its feasibility. Materials and Methods: Subsequent to lymphadenectomy, the oral and anal resection lines were sutured using an intraoperative endoscope. After closing the stomach circumferentially with clips, the specimen was rolled outward like a "donut." We resected the specimen circumferentially using a linear stapler, and anastomosis was completed simultaneously. We examined the feasibility of this procedure ex vivo, using three porcine stomachs, and in vivo, using one pig. Subsequently, we applied the procedure to 13 consecutive patients with middle-third early gastric cancer utilizing laparotomic, laparoscopic, and robotic PPG. Results: NoCEAM was completed in all porcine models and human cases. In the human cases, the mean operation time (±standard deviation) was 279±51 minutes, and mean blood loss volume was 22±45 mL. The mean number of linear staples used was 5.06±0.76. None of the patients had complications, and all were discharged on the eighth postoperative. The serum total protein, serum albumin, and hemoglobin levels did not change significantly after surgery. Conclusions: NoCEAM is feasible and safe for performing totally laparoscopic or robotic PPG. It may reduce postoperative complications, such as intra-abdominal infections.

Correlation between contrast leakage period of procedural rupture and clinical outcomes in endovascular coiling for cerebral aneurysms

  • Sung-Tae Kim;Sung-Chul Jin;Hae Woong Jeong;Jin Wook Baek;Young Gyun Jeong
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.4
    • /
    • pp.420-428
    • /
    • 2023
  • Objective: Intraprocedural rupture (IPR) is a fatal complication of endovascular coiling for cerebral aneurysms. We hypothesized that contrast leakage period may be related to poor clinical outcomes. This study aimed to retrospectively evaluate the relationship between clinical outcomes and contrast leakage period. Methods: Data from patients with cerebral aneurysms treated via endovascular coiling between January 2010 and October 2018 were retrospectively assessed. The enrolled patient's demographic data, the aneurysm related findings, endovascular treatment and IPR related findings, rescue treatment, and clinical outcome were analyzed. Results: In total, 2,859 cerebral aneurysms were treated using endovascular coiling during the study period, with IPR occurring in 18 (0.63 %). IPR occurred during initial frame coiling (n=4), coil packing (n=5), stent deployment (n=7), ballooning (n=1), and microcatheter removal after coiling (n=1). Tear sites included the dome (n=14) and neck (n=4). All IPRs were controlled and treated with coil packing, with or without stenting. Flow arrest of the proximal balloon was not observed. Temporary focal neurological deficits developed in two patients (11.1%). At clinical follow-up, 14 patients were classified as modified Rankin Scale (mRS) 0, three as mRS 2, and one as mRS 4. The mean contrast leakage period of IPR was 11.2 min (range: 1-31 min). Cerebral aneurysms with IPR were divided into late (n=9, mean time: 17.11 min) and early (n=9, mean time: 5.22 min) control groups based on the criteria of 10 min of contrast leakage period. No significant between-group differences regarding clinical outcomes were observed after IPR (p=1). Conclusions: In our series, all patients with IPR were controlled with further coil packing or stenting without proximal balloon occlusion within 31 min of contrast leakage. There was no difference in clinical outcomes when the long contrast leakage period group and short contrast leakage period group were compared.

Clinical Analysis to the Early Results of the CABG (관상동맥우회술의 조기 성적에 대한 임상적 고찰)

  • Kim, Dae-Sig;Yang, Jin-Young;Koo, Won-Mo;Moon, Seung-Chul;Lee, Gun;Lee, Hyeon-Jae;Lim, Chang-Young
    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1043-1048
    • /
    • 1998
  • Background: As coronary arterial disease is increasing, we evaluated the patients who underwent CABG(Coronary Artery Bypass Grafting) and thus report the early results and risk factors related to mortality and morbidity. Materials and methods: Between July 1996 and February 1998, 42 patients underwent CABG. We analyzed age, sex, preoperative ejection fraction, Canadian heart classification, prevalence factors of CAD(Coronary Artery Disease), angiographic findings, graft vessel numbers, IMA(Internal Mallary Artery) use, ECC* (extracorporeal circulation) time and morbidity. We also evaluated the mortality rate and the causes of death. Results: Complication was developed at 17cases. The average age of the complication group was 61±11.9 years and that of the noncomplication group was 51±10.5 years(p=0.004). ECC time was 198±42.5(min) in the complication group and 158±47.4(min) in the noncomplication group(p=0.008). The other factors had no correlation to the morbidity, statistically. The average follow up duration was 12.5 months and all the patients were alive except for the 2 expired cases. The mortality rate was 4.7%, among which one patient who underwent CABG with aortic valve replacement died due to multiorgan failure and the other died due to sepsis with pneumonia and wound infection. Conclusions: We conclude that the risk factors related to morbidity were age and ECC time, and that there were no correlations between other factors and morbidity.

  • PDF

Analysis of Complications Associated with the Nuss Procedure: Risk Factors and Preventive Measures (너스수술의 합병증에 대한 고찰: 위험인자 분석과 예방책의 제시)

  • Park, Hyung-Joo;Chang, Won-Ho;Jeon, Cheol-Woo;Park, Han-Gyu;Lee, Seock-Yeol;Lee, Cheol-Sae;Youm, Wook;Lee, Kihl-Roh
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.524-529
    • /
    • 2004
  • Background: Since the Nuss procedure for the correction of pectus excavatum is in its early stage, there have been problems that need to be solved. We examined complications in a single-institute experience of the Nuss technique in order to develop possible solutions to prevent them. Material and Method: 335 consecutive patients, who underwent the modified Nuss procedure between August 1999 and October 2002, were studied retrospectively. Median age was 8 years (range 1 to 46). 264 patients (78.8%) were in pediatric group (age$\leq$15) and 71 patients (21.2%) were in adult group (age> 15). 193 patients (57.6%) had symmetric and 142 patients (42.4%) had asymmetric pectus configurations. Risk factors predicting postoperative complications were analyzed using multi-variate logistic regression. Result: Postoperative complication rates were 18.9% (61/335) in total patients. Frequent complications were pneumothorax 24 (7.5%), bar displacement 11 (3.4%), and wound seroma 10 (3.1%) in order. Early complications (within a month, 49 cases, 15.2%) were pneumothorax (n=23, 6.9%), wound seroma (n=12, 3.6%), and bar displacement (n=8, 2.4%). Late complications (after a month, 12 cases, 3.7%) were pericarditis and pericardial effusion (n=5, 1.5%), bar displacement (n=4, 1.2%), and hemothorax (n=3, 0.9%). Techniques were modified to prevent complications especially in bar shaping and fixation, which led to decrease complication rate in later experience (Operation Date 1: 15/51 (29.4%) vs Operation Date 2: 34/284 (12.0%), p=0.004). Grand Canyon type (eccentric long canal type) showed higher complication rate than other types (GC type: 12/30(40%) vs Others: 37/305 (12.1%), p<0.001). Major risk factors are severity of pectus (OR=2.88, p=0.038), Grand Canyon type (OR=2.82, p=0.044), and Op. Date 1 (OR=4.05, p=0.001). Conclusion: Major complications were related to severe eccentric type of pectus configuration (Grand Canyon type) and lack of surgeon's experience (Op. Date 1). Com-plication rate was reduced with accumulation of experience and advancement of surgical techniques. The Nuss procedure can be performed at a low risk of complications with our current technique.