• Title/Summary/Keyword: Ear canal

Search Result 116, Processing Time 0.033 seconds

Ceruminous Gland Tumor in a Dog (귀지선 종양 증례 1)

  • 최을수;제갈준;배보경;최지희;정성목;?해경;김대용;이상우
    • Journal of Veterinary Clinics
    • /
    • v.19 no.3
    • /
    • pp.353-356
    • /
    • 2002
  • A 9-year-old male Yorkshire terrior with recurrent chronic otitis externa and otitis interna was referred to the Veterinary Medical Teaching Hospital of Seoul National University. Radiographic findings indicated mineralization around the right ear canal. A tan nodular mats, 1 cm in diameter. was noted near the tympanum after total ear canal ablation. Cytologically. the imprint smear of the cut surface of the mass produced clusters of cells with abundant and weakly basophilic cytoplasm, one small round nucleus and one or two nucleoli, mixed with both degenerate and non degenerate neutrophils. The location of the nuclei was eccentric, and some cells contained somewhat coarse black granules in their cytoplasms, on which the mass was diagnoted as ceruminous gland adenoma or hyperplasia associated with inflammation. Histopathologic examination of the tumor was compatible with a diagnosit of ceruminous gland adenoma. The patient is responding well to sugery and antimicrobial treatment.

Field Attenuation of Foam Earplugs

  • Copelli, Fran;Behar, Alberto;Le, Tina Ngoc;Russo, Frank A.
    • Safety and Health at Work
    • /
    • v.12 no.2
    • /
    • pp.184-191
    • /
    • 2021
  • Background: Hearing protection devices (HPDs) are often used in the workplace to prevent hearing damage caused by noise. However, a factor that can lead to hearing loss in the workplace is improper HPD fitting, and the previous literature has shown that instructing workers on how to properly insert their HPDs can make a significant difference in the degree of attenuation. Methods: Two studies were completed on a total of 33 Hydro One workers. A FitCheck Solo field attenuation estimation system was used to measure the personal attenuation rating (PAR) before and after providing one-on-one fitting instructions. In addition, external ear canal diameters were measured, and a questionnaire with items related to frequency of use, confidence, and discomfort was administered. Results: Training led to an improvement in HPD attenuation, particularly for participants with poorer PARs before training. The questionnaire results indicated that much HPD discomfort is caused by heat, humidity, and communication difficulties. External ear canal asymmetry did not appear to significantly influence the measured PAR. Conclusion: In accordance with the previous literature, our studies suggest that one-on-one instruction is an effective training method for HPD use. Addressing discomfort issues from heat, humidity, and communication issues could help to improve the use of HPDs in the workplace. Further research into the effects of canal asymmetry on the PAR is needed.

A Study on Design Parameters for Ready-made Ear Shell of Hearing Aids (보청기용 범용 이어쉘을 위한 설계 파라미터에 관한 연구)

  • Urtnasan, Erdenebayar;Jeon, Yu-Yong;Park, Gyu-Seok;Song, Young-Rok;Lee, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.1055-1061
    • /
    • 2011
  • In this study, main parameters: aperture, first bend and second bend which express a structure of ear canal are extracted in order to modeling and manufacture the ready-made ear shells of hearing aids. The proposed parameter extraction method consists of 2 important algorithms, aperture detection and feature detection. In the aperture detection algorithm, aperture of 3-D scanned virtual ear impression and parameters relating to ear shell of hearing aid are determined. The feature detection algorithm detects first bend, second bend, and related parameters. Through these two algorithms, parameters for aperture, first bend, and second bend are extracted to model the ready-made ear shell of hearing aid. The values of these extracted parameters from 36 people's right ear impression are analyzed and measured statistically. As a result of the analysis, it has been found that it is possible to classify ready-made ear shell parameters by age and size. The ready-made ear shell parameters are classified 3-size for 20 years old and 2-size for 60 years olde. Using 3D rhino program, virtual ready-made ear shell is reconstructed by parameters of every type, and simulated to model it. A final product was produced by transferring simulation result with rapid prototyping system. The modeled ready-made ear shell is evaluated with the objective and subjective method. Objective method is the comparison volume ratio and overlapped volume ratio of ear impression from randomly chosen 18 people and ready-made ear shell. And subjective method is that the final product of ready-made ear shell is used by users and the satisfaction number drawn from well fitting and comfortable testing was evaluated. In the result of the evaluation, it has been found that volume ration is 70%, big and middle size ready-made ear shell products are possible, and the satisfaction number is high.

The External Auricular Reconstruction with Inferior Based Retroauricular Flap Including the Posterior Auricular Artery

  • Choi, Jong Hwan;Ki, Sae Hwi
    • Archives of Reconstructive Microsurgery
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Purpose: The external ear is a common area of trauma on the body prone to exposure of ultraviolet light, which can lead to skin cancer. Thus, variable techniques have been developed and used for reconstruction of the external ear. The aim of this study is to review the surgical method, its area of application, as well as advantages and pitfalls of reconstruction of the external ear with inferior based retroauricular flaps. Materials and Methods: Eight patients underwent external ear reconstruction with inferior based retroauricular flap for external ear defects in our institute from September 2012 to June 2015. According to the area of the defect, patients were classified as middle 1/3 (n=4), inferior 1/3 (n=2), superior auroculo-cephalic sulcus (n=1), and external auditory canal (n=1). Results: All of the flaps survived the operation and there was no marginal necrosis. Mean size of the defect was $2.8{\times}1.8cm$ and mean size of the retroauricular flap was $5{\times}2cm$. For insetting of the flap, a subcutaneous tunneling technique was used in 6 cases and rotation without subcutaneous tunneling was used in 2 cases. Transient paresthesia occurred in 3 cases. Two cases recovered within 3 months but one case did not recover until 6 months. Conclusion: The inferior based retroauricular flap is an available technique in external ear reconstruction with one stage operation.

PCB Layout for Digital Hearing Aids (디지털 보청기용 PCB 제작)

  • Jarng, Soon-Suck;Kim, Kyoung-Suck;Kwon, You-Jung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1012-1015
    • /
    • 2004
  • Digital hearing aids enclose $6{\sim}8$ tiny components. Those electromechanical components are individually wired by soldering which is a manual labor and sometimes causes components' damage by heating. This paper suggests a PCB design for overcome these problems. Several PCBs are designed and manufactured and circuited to produce ITE(In-the-Ear) type hearing aids which are inserted in the ear canal. The most optimal size of the PCB design for the ITE hearing aid is presented in this paper.

  • PDF

Parameter Extraction and Simulation in order to Manufacture Ready-made Ear Shell for CIC Type Hearing Aids (CIC형 보청기용 범용 이어쉘 제작을 위한 파라미터 추출 및 시뮬레이션)

  • U, Erdenebayar.;Jeon, Y.Y.;Park, G.S.;Song, Y.R.;Lee, S.M.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.321-327
    • /
    • 2010
  • Most of the ear shells of hearing aids are manufactured manually, and it is one of the reasons that the cost of the custom-made hearing aids can be increased. Thus it is required to manufacture the ready-made ear shell for the purpose of easy manufacturing and decrease in cost. In this study, we extract parameters in order to manufacture the ready-made ear shell for CIC type hearing aids and simulate to reconstruct the ear shell using the extracted parameters. To parameter extraction, we set up the eleven parameters for the ready-made ear shell based on anatomical characteristics of the ear canal, and we found values of the parameters from twenty-one impressions in their 20s and twelve impressions in their 60s using aperture detection and feature detection algorithms. Classifying the parameters by size, we also determine the parameters of ready-made ear shell into three types for people in their 20s and two types for people in their 60s. Each ready-made ear shell was simulated to reconstruct using figured parameters, and evaluated the rate of agreement with unused impressions for setting parameters. To evaluate the ready-made ear shell, we calculate the volume ratio and intersection between of the each impression and ready-made ear shell, and the intersection ratio using the intersection volume and ready-made ear shell volume. As a result, the volume ratio was about 70%, and volume match ratio was also up to 70%. It means that the ready-made ear shell we simulated is the significantly matched to impression.

Anatomical and Pathological Findings of Magnetic Resonance Imaging in Idiopathic Sudden Sensorineural Hearing Loss

  • Kim, Min Bum;Lim, Jihyun;Moon, Il Joon
    • Journal of Audiology & Otology
    • /
    • v.24 no.4
    • /
    • pp.198-203
    • /
    • 2020
  • Background and Objectives: We sought to evaluate the diagnostic and prognostic value of measurable parameters of internal auditory canal (IAC) magnetic resonance imaging (MRI) in patients with idiopathic sudden sensorineural hearing loss (ISSNHL). Subjects and Methods: We retrospectively reviewed the patients with ISSNHL who underwent IAC MRI from January 2008 to March 2019. Measurable parameters of IAC MRI, such as the diameter of the IAC, bony cochlear nerve canal, and cross-sectional area of the cochlear nerve, were measured by a single examiner. These parameters were then compared between the affected and healthy sides. Inner-ear abnormalities such as intralabyrinthine hemorrhage or labyrinthitis were also evaluated. The relationship between the surveyed parameters and the diagnosis of ISSNHL was assessed. Results: A total of 208 patients with ISSNHL were included. The measured parameters of IAC MRI were not different between the affected and healthy sides and were also not associated with the diagnosis of ISSNHL. However, inner-ear abnormalities of IAC MRI in ISSNHL displayed a significant association with worse hearing before and after treatment. An age that was older than 40 years also correlated with poorer outcomes. Further, inner-ear abnormalities were more frequently detected when IAC MRI was performed early after ISSNHL onset. Conclusions: Patients with ISSNHL and inner ear abnormalities such as intralabyrinthine hemorrhage or labyrinthitis identified via IAC MRI may experience poorer hearing outcomes. To detect such abnormal findings, it is recommended to perform IAC MRI early after the onset of ISSNHL.

Anatomical and Pathological Findings of Magnetic Resonance Imaging in Idiopathic Sudden Sensorineural Hearing Loss

  • Kim, Min Bum;Lim, Jihyun;Moon, Il Joon
    • Korean Journal of Audiology
    • /
    • v.24 no.4
    • /
    • pp.198-203
    • /
    • 2020
  • Background and Objectives: We sought to evaluate the diagnostic and prognostic value of measurable parameters of internal auditory canal (IAC) magnetic resonance imaging (MRI) in patients with idiopathic sudden sensorineural hearing loss (ISSNHL). Subjects and Methods: We retrospectively reviewed the patients with ISSNHL who underwent IAC MRI from January 2008 to March 2019. Measurable parameters of IAC MRI, such as the diameter of the IAC, bony cochlear nerve canal, and cross-sectional area of the cochlear nerve, were measured by a single examiner. These parameters were then compared between the affected and healthy sides. Inner-ear abnormalities such as intralabyrinthine hemorrhage or labyrinthitis were also evaluated. The relationship between the surveyed parameters and the diagnosis of ISSNHL was assessed. Results: A total of 208 patients with ISSNHL were included. The measured parameters of IAC MRI were not different between the affected and healthy sides and were also not associated with the diagnosis of ISSNHL. However, inner-ear abnormalities of IAC MRI in ISSNHL displayed a significant association with worse hearing before and after treatment. An age that was older than 40 years also correlated with poorer outcomes. Further, inner-ear abnormalities were more frequently detected when IAC MRI was performed early after ISSNHL onset. Conclusions: Patients with ISSNHL and inner ear abnormalities such as intralabyrinthine hemorrhage or labyrinthitis identified via IAC MRI may experience poorer hearing outcomes. To detect such abnormal findings, it is recommended to perform IAC MRI early after the onset of ISSNHL.