• 제목/요약/키워드: EX2100

검색결과 3건 처리시간 0.016초

발전기 여자기시스템 주제어전원공급장치 국산화 개발 (The Development of EPSM(Exciter Power Supply Module) Localization in Generator Exciter(EX2100) System)

  • 이기선;박정철;추순남
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.101-107
    • /
    • 2016
  • The main target in this paper is the localization of VME Type EPSM in Generator Exciter(EX2100) System. Developed EPSM has the compatibility with the existing product in the structure and shape and electrical feature and so on, but it has a much improved capacity and reliability in comparison with origin company product. this paper, to improve these functions, put emphasis on protection, monitoring, power capacity increase(over 120%), an enlarged scale of input voltage supply, AC/DC dual voltage use and so on. After manufacturing product localization, it was carried out several tests for the performance and reliability verification of developed product. These tests were performed in Authorized Inspection Agency(KTL) and field application test and maker self-test were additionally performed. Finally, the results of all tests were "success".

Tow in 와류발생기에 의한 핀-관 열교환기의 성능실험 (Performance Evaluation in Fin-Tube Heat Exchanger by Tow-In Winglet Pairs)

  • 곽경민;;배철호
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.87-94
    • /
    • 2003
  • To reduce the air side pressure drop in air-cooled heat exchanger, tow-in type winglet vortex generators are applied. A specially designed multiple-channel test core was used in the experiments for the various geometry of winglet vortex generators. The proposed tow-in type vortex generator gives significant separation delay, reduces form drag, and removes the zone of poor heat transfer from near-wake of the tubes. The results show the significant pressure drop reduction for the tow-in win91e1 vortex generators with the similar enhancement of the heat transfer as other vortex generator applications in heat exchanger. In the range of Reynolds number of 350 to 2100 the pressure drop decrease 8∼15% and 34∼55% for the in-line and staggered tube banks, respectively, compared to those without vortex generators.

MLC leakage를 이용할 Verification의 효용성 고찰 (Verification of set-up accuracy using MLC leakage)

  • 윤인하;홍동기;정왕권;서동린;윤화룡;김정만
    • 대한방사선치료학회지
    • /
    • 제16권1호
    • /
    • pp.11-19
    • /
    • 2004
  • 서론 및 목적 : 세기변조 방사선치료와 전신 정위적 방사선치료에서 5mm이내의 위치 정확성확인 (L-gram)은 환자치료 목적 달성을 위한 중요한 QA과정의 하나이다. 이에 본원에서 제작한 scale point를 이용하여 L-gram 영상을 얻어 환자치료의 정확성을 향상시키고자 한다. 대상 및 방법 : 본원의 MLC 부착장비인 CL2100C/D, CL21EX에서 치료중인 IMRT, SRS환자를 대상으로 기존의 상품화된 port film graticule과 본원에서 제작한 MLC scale pointer를 비교 분석하였다. 결과 : MLC를 이용한 scale pointer는 beam의 확산까지 고려한 정확한 위치를 나타내었고 MLC의 교차로 생기는 pixel 모양의 형성을 통해 어떠한 위치에서도 정확한 확인이 가능했다. 결론 및 고찰 : L-gram 확인시 약간의 시간적 투자($1{\sim}2$분)로서 정확한 위치를 나타냄으로서 L-gram 확인시간 단축과 치료부위의 정확한 위치 확인을 할 수 있었다.

  • PDF