• Title/Summary/Keyword: EWT

Search Result 36, Processing Time 0.025 seconds

A Study on Selection of Pipe Materials Considering EWT (EWT를 고려한 지중열교환기 파이프 선정에 관한 연구)

  • Ryu, Hyung-Kyou;Chung, Min-Ho;Lee, Byung-Seok;Choi, Hyun-Jun;Choi, Hang-Seok
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.2
    • /
    • pp.13-18
    • /
    • 2014
  • This paper proposes an optimum pipe material (PVC vs. PE) design & selection for open loop ground heat exchangers. Heat exchange efficiency and/or workability, and the need for trench insulation were investigated by comparing EWT (cooling mode) of each system. CFD simulations for the PVC and PE pipe with the same inner diameter show similar EWT. This is because the PVC pipe has a small thickness but a low thermal conductivity as compared to the PE pipe, and thus these two properties tend to offset each other. However, a hypothetically insulated pipe led to a meaningful drop of EWT. This means pipe insulation is of importance in performance of ground heat exchangers. From analyzing climate data and system operation, it is not advantageous to insulate trench pipes due to construction difficulties and ground temperature characteristics that are seasonally varied.

Time-varying characteristics analysis of vehicle-bridge interaction system using an accurate time-frequency method

  • Tian-Li Huang;Lei Tang;Chen-Lu Zhan;Xu-Qiang Shang;Ning-Bo Wang;Wei-Xin Ren
    • Smart Structures and Systems
    • /
    • v.33 no.2
    • /
    • pp.145-163
    • /
    • 2024
  • The evaluation of dynamic characteristics of bridges under operational traffic loads is a crucial aspect of bridge structural health monitoring. In the vehicle-bridge interaction (VBI) system, the vibration responses of bridge exhibit time-varying characteristics. To address this issue, an accurate time-frequency analysis method that combines the autoregressive power spectrum based empirical wavelet transform (AR-EWT) and local maximum synchrosqueezing transform (LMSST) is proposed to identify the time-varying instantaneous frequencies (IFs) of the bridge in the VBI system. The AR-EWT method decomposes the vibration response of the bridge into mono-component signals. Then, LMSST is employed to identify the IFs of each mono-component signal. The AR-EWT combined with the LMSST method (AR-EWT+LMSST) can resolve the problem that LMSST cannot effectively identify the multi-component signals with weak amplitude components. The proposed AR-EWT+LMSST method is compared with some advanced time-frequency analysis techniques such as synchrosqueezing transform (SST), synchroextracting transform (SET), and LMSST. The results demonstrate that the proposed AR-EWT+LMSST method can improve the accuracy of identified IFs. The effectiveness and applicability of the proposed method are validated through a multi-component signal, a VBI numerical model with a four-degree-of-freedom half-car, and a VBI model experiment. The effect of vehicle characteristics, vehicle speed, and road surface roughness on the identified IFs of bridge are investigated.

A Study on Entering Water Temperature in Vertical Closed Ground Loop System Considering the Economical Feasibility in Load of the Office Building (사무시설에 수직형 지열원 냉 난방시스템의 경제성을 고려한 인입온도(EWT)에 관한 연구)

  • Lee, Byung-Doo;Lee, Dae-Woo;Lee, Se-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.579-585
    • /
    • 2009
  • Recently, Vertical-Closed Loop system using geothermal which is the most efficient among the building cooling and heating systems is coming into wide spread due to assistance of domestic policies. However, there is a limitation that a design of ground heat exchanger taking 60% of construction cost is done by GLD and GLHEPRO programs without specific guidelines and consideration on Entering Water Temperature(EWT). For getting an optimal EWT, we analyzed the costs for construction of ground heat exchanger and cooling and heating for 15 years. In the results, reduction of construction costs as the length of ground heat exchanger shortens was much greater than increase of the electrical power consumption as COP gets low. EWT that COP of heat pump can be 3.76 or above was below $31^{\circ}C$ in cooling and was over $5^{\circ}C$ in heating.

  • PDF

Laser via drilling technology for the EWT solar cell (EWT 태양전지 제작을 위한 레이저 미세 관통홀 가공 기술)

  • Lee, Hong-Gu;Seo, Se-Young;Hyun, Deoc-Hwan;Lee, Yong-Wha;Kim, Gang-Il;Jung, Woo-Won;Lee, Ah-Reum;Cho, Jaee-Ock
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.103-111
    • /
    • 2011
  • Laser drilling of vias is the one of key technologies in developing Emitter-Wrap Through(EWT) solar cell which is particularly attractive due to the use of industrial processing and common solar grade p-type silicon materials. While alternative economically feasible drilling process is not available to date, the processing time and laser induced damage should be as small as possible in this process. This paper provides an overview on various factors that should be considered in using the laser via drilling technology for developing highly efficient and industrially applicable EWT solar cells.

Cytotoxicity and Genotoxicity of Newly Developed Calcium Phosphate-based Root Canal Sealers (신개발 인산칼슘계 근관 봉함재의 세포독성 및 유전독성에 관한 연구)

  • Kim, Hee-Jung;Baek, Seung-Ho;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.36-49
    • /
    • 2006
  • The purpose of this study was to compare the cytotoxicity by MTT test and genotoxicity by Ames test of new calcium phosphate-based root canal sealers (CAPSEAL I, CAPSEAL II) with commercially available resin-based sealers (AH 26, AH Plus) , zinc oxide eugenol-based sealers (Tubliseal EWT, Pulp Canal Sealer EWT), calcium hydroxide-based sealer (Sealapex), and tricalcium phosphate based sealers (Sankin Apatite Root Canal Sealer I, II, III). According to this study, the results were as follows : 1. The extracts of freshly mixed group showed higher toxicity than those of 24 h set group in MTT assay (p<0.001). 2. CAPSEAL I and CAPSEAL II were less cytotoxic than AH 26, AH Plus, Tubliseal EWT, Pulp Canal Sealer EWT Sealapex and SARCS II in freshly mixed group (p<0.01). 3. AH 26 in freshly mixed group showed mutagenicity to TA98 and TA100 with and without S9 mix and AH Plus extracts also were mutagenic to TA100 with and without S9 mix. 4. Tubliseal EWT, Pulp Canal Sealer EWT and Sealapex in freshly mixed group were mutagenic to TA100 with S9 mix. 5. Among those of 24 h set groups the extracts of SARCS II were mutagenic to TA98 with and without S9 mix and AH 26 showed mutagenic effects to TA98 with S9 mix. 6. No mutagenic effect of CAPSEAL I and CAPSEAL II was detected. 7. There is no statistically significant difference between CAPSEAL I and CAPSEAL II at MTT assay and Ames test in both freshly mixed group and 24 h set group.

Cytotoxicity and Antibacterial property of New Resin-based Sealer (새로운 레진 계통의 근관봉함재의 독성과 항균 작용에 대한 연구)

  • Park, So-Young;Lee, Woo-Cheol;Lim, Sung-Sam
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.2
    • /
    • pp.162-168
    • /
    • 2003
  • 이 연구는 기존의 레진 근관봉함재를 보완하여 개발한 근관봉함재(Adseal; 새로운 레진 계통의 근관봉함재)를 이미 상품화된 레진 계통의 근관봉함재(AH 26, AH Plus), 산화 아연 유지놀 계통의 근관봉함재(TubliSeal EWT, Pulpcanal sealer EWT), 수산화 칼슘 계통의 근관봉함재(Sealapex)와 비교하여 세포독성과 항균작용을 평가하고자 한다. 세포독성 실험은 L929 쥐의 섬유아세포를 사용하여 세포의 viable ratio를 계산한 후, Giemsa stain으로 염색하여 세포의 양상을 관찰하였고, 항균작용 실험은 Enterococcus faecalis Porphyromonas endodontalis, Porphyomonas gingivalis, Prevotella intermedia, Fusobacterium nucleatum 와 Fusobacterium necrophorum를 사용하여 agar diffusion test로 평가한다. Adseal은 다른 근관봉함재에 비해 훨씬 낮은 세포독성을 보였고, AH Plus, AH 26, TubliSeal EWT, Sealapex, Pulpcanal sealer EWT의 순으로 세포독성의 정도가 높아짐을 알 수 있었다. 또한 Adseal은 Enterococcus faecalis 에서는 낮은 항균작용을 보이지만, Black-pigmented bacteria 에서는 높은 항균작용을 보이는데, 모든 근관봉함재는 서로 다른 종에 따라 어느 정도의 항균효과를 가지고 있음을 알 수 있었다.

A Study on the optimal design of MOSCOS arrangement to solve the EMI between EWT and MOSCOS (전자전훈련지원체계와 해상작전위성통신체계 간 전자기 간섭 개선을 위한 최적배치에 대한 연구)

  • Lee, Ji-Hyeog;Jo, Kyu-Lyong;Seo, Hyeong-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.15-24
    • /
    • 2019
  • The optimum solutions of MOSCOS antenna arrangement were studied to solve the EMI between it and EWT mounted on an MTB. Two candidates of optimal place for MOSCOS antenna were determined by using a fishbone diagram to determine seven reasons based on 4M1E, to identify the design factors on Friis equations, and to analyze the case study of EMI related to MOSCOS. MOSCOS antenna was rearranged by the final optimal position, which was selected by measuring the Power Spectral Density (PSD) at two locations, and the proposed improvement was tested on board to determine its efficiency.

An Experimental Study on the Cooling Operation Characteristics for Different Entering Water Temperatures In Geothermal Heat Pump System (지열히트펌프 시스템의 EWT의 변화에 따른 냉방운전 특성에 관한 실험적 연구)

  • Ahn, Byung-Chun;Kim, Jae-Wan
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • In this paper, an experimental study on the cooling operation characteristics for different entering water temperatures in geothermal heat pump system are carried out by using Lab VIEW system program Set-point temperature controls for cooling water and supply air temperatures is applied to analyze the energy consumption and control performances. As a result, the system responses show that different entering water temperatures(EWT) effect greatly on the energy consumption and system COP.

Electrical and Optical Properties for TCO/Si Junction of EWT Solar Cells (TCO/Si 접합 EWT 태양전지에 관한 전기적 및 광학적 특성)

  • Song, Jinseob;Yang, Jungyup;Lee, Junseok;Hong, Jinpyo;Cho, Younghyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.39.2-39.2
    • /
    • 2010
  • In this work we have investigated electrical and optical properties of interface for ITO/Si with shallow doped emitter. The ITO is prepared by DC magnetron sputter on p-type monocrystalline silicon substrate. As an experimental result, The transmittance at 640nm spectra is obtained an average transmittance over 85% in the visible range of the optical spectrum. The energy bandgap of ITO at oxygen flow from 0% to 4% obtained between 3.57eV and 3.68eV (ITO : 3.75eV). The energy bandgap of ITO is depending on the thickness, sturcture and doping concentration. Because the bandgap and position of absorption edge for degenerated semiconductor oxide are determined by two competing mechanism; i) bandgap narrowing due to electron-electron and electron-impurity effects on the valance and conduction bands (> 3.38eV), ii) bandgap widening by the Burstein-Moss effect, a blocking of the lowest states of the conduction band by excess electrons( < 4.15eV). The resistivity of ITO layer obtained about $6{\times}10^{-4}{\Omega}cm$ at 4% of oxygen flow. In case of decrease resistivity of ITO, the carrier concentration and carrier mobility of ITO film will be increased. The contact resistance of ITO/Si with shallow doped emitter was measured by the transmission line method(TLM). As an experimental result, the contact resistance was obtained $0.0705{\Omega}cm^2$ at 2% oxygen flow. It is formed ohmic-contact of interface ITO/Si substrate. The emitter series resistance of ITO/Si with shallow doped emitter was obtained $0.1821{\Omega}cm^2$. Therefore, As an PC1D simulation result, the fill factor of EWT solar cell obtained above 80%. The details will be presented in conference.

  • PDF

Sizing of Vertical Borehole Heat Exchangers using TRNOPT (TRNOPT를 이용한 수직 지중열교환기 길이 산정 방법에 관한 연구)

  • Park, Seung-Hoon;Lee, Hyun-Soo;Jang, Young-Sung;Kim, Eui-Jong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.10
    • /
    • pp.402-407
    • /
    • 2016
  • Ground-coupled heat pump systems have been widely used, as they are regarded as a renewable energy source and ensure a high annual efficiency. Among the system components, borehole heat exchangers (BHE) play an important role in decreasing the entering water temperature (EWT) to heat pumps in the cooling season, and consequently improve the COP. The optimal sizing of the BHEs is crucial for a successful project. Other than the existing sizing methods, a simulation-based design tool is more applicable for modern complex geothermal systems, and it may also be useful since design and engineering works operate on the same platform. A simulation-based sizing method is proposed in this study using the well-known Duct STorage (DST) model in Trnsys. TRNOPT, the Trnsys optimization tool, is used to search for an optimal value of the length of BHEs under given ground loads and ground properties. The result shows that a maximum EWT of BHEs during a design period (10 years) successfully approaches the design EWT while providing an optimal BHE length. Compared to the existing design tool, very similar lengths are calculated by both methods with a small error of 1.07%.