• Title/Summary/Keyword: EURO6

Search Result 154, Processing Time 0.024 seconds

Comparison on Nano-particle Number Measurement Characteristics for Different Particle Generators between Spray type and Soot Type (Spray type과 Soot type 입자발생기별 나노입자 개수농도분포 측정특성 비교)

  • Kim, M.S.;Kwon, J.W.;Chung, M.C.;Lee, J.W.
    • Journal of ILASS-Korea
    • /
    • v.17 no.4
    • /
    • pp.185-191
    • /
    • 2012
  • Particulate matters (PM) that is generated by most diesel engine is regulated by the mass concentration measured by the conventional method it had been. Recently, Europe PMP (Particle Measurement Program) decided to start the regulation of vehicle's nano-sized particle number (PN) from the year of 2011 because of nano-particle's higher degree of harm to the human body. So firstly, the standard level of PN emission is introduced in the Euro 5/6 emissions regulation with a limit of $6{\times}10^{11}$ per km for light duty vehicle. Also KPMP(Korea Particle Measurement Program) was organized to copy quickly international technical trend. In this paper, it was investigated the nano-sized PN measurement characteristics for different particle generators between spray type and soot type. And the difference ratio between particle generators, the characteristic of PN concentration, counting efficiency and linearity was analyzed. Then, we make conclusions as followed. When particle diameter is increased, counting efficiency of two generators is decreased. Also Secondary calibration method is more higher 3% than Primary calibration method. Finally, SOF which is included in soot particles is not totally removed so it have great influence on test result of counting efficiency and linearity.

A Particulate Matter Sensor with Groove Electrode for Real-Time Diesel Engine On-Board Diagnostics

  • Kim, S.;Kim, Y.;Lee, J.;Lim, S.;Min, K.;Chun, K.
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.191-196
    • /
    • 2013
  • A particulate matter sensor fabricated by MEMS process is proposed. It is developed to accommodate Euro6 on-board diagnostics regulation for diesel automobile. In the regulation, emission of diesel particulate matter is restricted to 9 mg/km. Particulate matter sensor is designed to use induced charges by charged particulate matter. To increase sensitivity of the sensor, groove is formed on sensor surface because wider surface area generates more induced charges. Sensitivity of the sensor is measured 10.6 mV/(mg/km) and the sensor shows good linearity up to 15.7 mg/km. Also its minimum detectable range is about 0.25 mg/km. It is suitable to detect failure of a diesel particulate filter which should filter particulate matter more than 9 mg/km. For removing accumulated particulate matter on the sensor which can disturb normal operation, platinum heater is designed on the backside of the sensor. The developed sensor can sense very low amount of particulate matter from exhaust gas in real-time with good linearity.

A Review on the Atmospheric Concentrations of Polycyclic Aromatic Hydrocarbons (PAHs) in Asia Since 2000 - Part II: Data from Developing Countries

  • Suvarapu, Lakshmi Narayana;Seo, Young-Kyo;Cha, Yoon-Chang;Baek, Sung-Ok
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.3
    • /
    • pp.169-191
    • /
    • 2012
  • This review paper describes the ambient air PAH concentrations in different developing Asian countries, including China, Afghanistan, India, Malaysia, Turkey, Vietnam, Sri Lanka, Thailand and Cambodia. In this study, more than 75 research papers published in the English literature were reviewed with respect to the seasonal and locational concentrations of PAHs in each of 9 different Asian countries. This study compared, discussed and tabulated the PAH concentrations in developing Asian countries over a one decade (2000-2011) period. The PAH concentrations measured in developing countries highlights the necessity to improve the air quality in those countries. Compared to the developed nations in Asia, developing countries are almost one decade away from implementing environmental policies, such as Euro standards. This review discusses the reasons for the high PAH concentrations in developing nations particularly in China and India. Based on the literature available, some suggestions are made to reduce the concentrations of PAHs in the ambient air of developing nations. The total data obtained from the literature survey is tabulated and presented as supplementary information at the end of the manuscript.

A Study on Characteristics of Performance and Emission by CRDI Engine's Injection Strategy (커먼레일 디젤기관에서 분사전략에 따른 성능 및 배출가스에 관한 연구)

  • Eom, Dong-Seop;Ko, Dong-Kyun;Ra, Wan-Yong;Lee, Seang-Wock
    • Journal of ILASS-Korea
    • /
    • v.16 no.3
    • /
    • pp.134-139
    • /
    • 2011
  • Recent research has focused on engine combustion technology as well as application of after-treatment in order to comply with emission regulation. However, it is much more efficient way to control emissions from engine itself and furthermore research on engine control will provide the direction of after-treatment technology in future. Furthermore, emission standard regulation for passenger diesel vehicles has been stringent compared to others and nano-particles will be included in EURO6 regulation in Europe and similar emission standard will be introduced in Korea. A 3.0 liter high speed diesel engine equipped with by CRDI system of 160MPa injection pressure, and an intake/exhaust system of V type 6 cylinder turbo-intercooler was applied. The injection duration and injection quantity, pilot injection types which are related to CRDI and air/fuel ratio control applied by EVGT were changed simultaneously. Standard experiment procedure constituted dilution apparatus and CPC system to collect nano-particles and these test results were compared with regulated materials of CO, HC, NOx and investigated their relations and characteristics of nano-particles.

Long-run and Short-run Causality from Exchange Rates to the Korea Composite Stock Price Index

  • LEE, Jung Wan;BRAHMASRENE, Tantatape
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.6 no.2
    • /
    • pp.257-267
    • /
    • 2019
  • The paper aims to test long-term and short-term causality from four exchange rates, the Korean won/$US, the Korean won/Euro, the Korean won/Japanese yen, and the Korean won/Chinese yuan, to the Korea Composite Stock Price Index in the presence of several macroeconomic variables using monthly data from January 1986 to June 2018. The results of Johansen cointegration tests show that there exists at least one cointegrating equation, which indicates that long-run causality from an exchange rate to the Korean stock market will exist. The results of vector error correction estimates show that: for long-term causality, the coefficient of the error correction term is significant with a negative sign, that is, long-term causality from exchange rates to the Korean stock market is observed. For short-term causality, the coefficient of the Japanese yen exchange rate is significant with a positive sign, that is, short-term causality from the Japanese yen exchange rate to the Korean stock market is observed. The coefficient of the financial crises i.e. 1997-1999 Asian financial crisis and 2007-2008 global financial crisis on the endogenous variables in the model and the Korean economy is significant. The result indicates that the financial crises have considerably affected the Korean economy, especially a negative effect on money supply.

Study on the experimental single lung transplantation in the mongrel dogs(I) (한국산 잡견에서의 단일 폐 이식술에 관한 실험적 연구 (I))

  • 김주현
    • Journal of Chest Surgery
    • /
    • v.24 no.6
    • /
    • pp.533-540
    • /
    • 1991
  • We have performed 14 single lung transplantation in mongrel dogs transplanting the left lung exclusively from December 1989 to January 1991, in the department of thoracic surgery of Seoul National University Hospital. In the donor dogs, the main pulmonary artery was divided proximal to its bifurcation, and the left atrium was incised freeing the left veins with a generous atrial cuff. We used cold saline in the first 7 transplantation[group I ] and a Euro Collins solution in the remaining 7 transplantations[group II ] as a lung preservatives. The bronchus was divided at two cartilage rings proximal to the upper lobe bronchus take off. In the recipient procedure, we used a Fogarty catheter as a bronchus block. Left atrial anastomosis was performed first using 5 - 0 prolene and the pulmonary artery was anastomosed using 6 - 0 prolene. The bronchus was anastomosed next with 4 - 0 Vicryl interruptly and covered with a greater omentum which had been prepared previously. In group I the three dogs died at eleven hours, 5 days, and 14 days, postoperatively and the remaining four doings were killed at 5 days, 5 days, 6 days, and 12 days, respectively. In group II the two dogs died during the operation, one dog died at 6 hours, two dogs died at 6 days postoperatively. Two dogs were killed at 5 days, and 7 days. No significant difference was noted between the two groups in survival time, lung infiltration of transplanted lungs, and perfusion defects in perfusion lung scans. Of the 8 dogs which died naturally, the causes of death were as follows: 2 cases of sepsis, 2 cases of ventricular fibrillations, 2 cases of malnutrition, and 2 cases of respiratory failures.

  • PDF

A Trial for Development of Health Profile (KHP 1.0) to Measure the Self-Perceived Health Status of Korean (한국인의 자가평가 건강수준 측정도구(KHP 1.0) 개발)

  • Yang, Jin-Sun;Chun, Jin-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.1
    • /
    • pp.11-23
    • /
    • 2003
  • Objectives : The 1990s has seen advances in the conceptualization of self-perceived health status which has important roles for individual health and the quality of life. Many types of standardized questionnaires have been developed with the current wide use of SF-36, NHP, andEuroQol. However, the outcomes of these tools may be different with regard to regional, cultural and emotional backgrounds. The purpose of this study was to trial the development of a Korean Health Profile (KHP 1.0) to measure the self-perceived health stati of Koreans. Methods : The KHP 1.0 was designed on the basis of the Medical Outcome Study Form 36 (SF-36), the Nottingham Health Profile (NHP), and the EuroQOL. It was composed of 9 scales; physical functioning, role limitation-physical, pain, general health, energy, social isolation, sleep, role limitation-emotional, and e-motional health. Self-reported chronic disease conditions, and the Zung's Self-Rating Depression Scale (SDS), were also checked for the evaluation of clinical validity. This study was conducted, from December 2000 to January 2001, on 800 middle-aged parents, with four high school students, with 100 retest sets being conducted two weeks later. From the 800 subjects there were 588 complete responses (effective response 73.5%). The reliability of the test-retest results, and the factor analysis on the validity of the KHP 1.0 components, were evaluated using the SPSS (ver 10.0) software. Results : The reliability of the KHP 1.0 was good with Cronbach's alpha (>0.6), test-retest correlation coefficients (>0.5), but with no significant differences from the paired t-test. From the psychometric validity tests, the 9 scales of the KHP 1.0 were divided into two components; physical and mental, and trimmed to the established model with 55% of the total variance, with the exception of role limitation-emotional. The clinical validity on the basis of the comparison for the four characteristic groups; healthy, physical conditions only, mental conditions only, and physical and mental conditions were also good. Conclusions : The KHP 1.0 appears to be a valid measurement tool of self-perceived health stati of Koreans, although there are limitations, i.e. sample size was too small, a limited number of middle-aged subjects, and it was based on unconfirmed diagnoses, etc. Therefore, further study is required to standardize the assessment.

Evaluation of Health-related Quality of Life for Hypothesized Medical States Associated with Cervical Cancer

  • Murasawa, Hideki;Konno, Ryo;Okubo, Ichiro;Arakawa, Ichiro
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.9679-9685
    • /
    • 2014
  • Background: When evaluating health-economics for cervical cancer prevention policies in Japan, it is important to use Japanese value settings. This study aimed to obtain preference-based measures (preference measures) for hypothesized health states among healthy Japanese women, and to examine differences between the EuroQol-5D (EQ-5D) and standard gamble (SG) instruments. Materials and Methods: The investigation was performed among female students at a nursing university. We used written hypothetical scenarios describing three grades of cervical intraepithelial neoplasia (CIN) and eight stages of cervical cancer, both at diagnosis and after medical intervention. Preference measures were evaluated using both EQ-5D and SG. Results: We received responses from 136 women. The mean number of respondents per stage was 24.6 (SD: 2.7). At diagnosis, average EQ-5D scores for CIN1, CIN2, CIN3, IA1, IA2, IB1, IB2, IIA, IIB, III, and IV stages were 0.84 (0.14), 0.78 (0.12), 0.73 (0.10), 0.78 (0.12), 0.72 (0.12), 0.63 (0.13), 0.64 (0.12), 0.68 (0.08), 0.62 (0.13), 0.55 (0.21), and 0.18 (0.24), respectively. Using one-way analysis of variance with the Tukey-Kramer method for multiple comparisons (each stage vs. CIN1), we found significant differences for IB1 and more advanced stages (p<0.05). After medical intervention, corresponding EQ-5D scores were 0.84 (0.12), 0.81 (0.12), 0.84 (0.12), 0.80 (0.15), 0.78 (0.11), 0.64 (0.15), 0.63 (0.15), 0.71 (0.15), 0.50 (0.17), 0.52 (0.17), 0.21 (0.28). The multiple comparisons identified significant differences for IB1 and more advanced stages, excepting IIA (p<0.05). SG evaluations were more variable and relatively higher than EQ-5D evaluations. Conclusions: We obtained preference measures for three grades of CIN1-3 and eight stages of cervical cancer. In combination with appropriate sensitivity analyses, these preference measures will provide a basis for an economic evaluation of cervical cancer prevention in Japan. We suggest that EQ-5D is appropriate for cost-utility analysis of this topic.

Comparative Study of Prolonged Preservation Methods in Rabbit Heart for Transplantation (이식을 위한 가토심장의 장기 보존방법에 관한 비교 연구)

  • Jo, Hyeong-Gon;Kim, Su-Hyeon;Kim, Song-Myeong
    • Journal of Chest Surgery
    • /
    • v.30 no.1
    • /
    • pp.1-10
    • /
    • 1997
  • The successful cardiac transplantation depends partly on the donor heart preservation by a solution that will ensure recovery of myocardial function. The purpose of this study was to perform the evaluation of various preservation solutions and to accumulate the data on the requisites for ideal preservation solution. The experimental setup was the constant pressure Langendorffs perfusion system. Isolated rabbit hearts were perfused for 20minutes with unarm Krebs-Henseleit solution, stored for 4 hours in cold preservation solution after cardioplegia, and then were reperfused for 20minutes. The 4 experimental groups were prepared Hartmann's solution group (group 1, control), modified Euro-collins solution group(group II. MEC), modified University of Wisconsin group (group n, MUW), and CK solution(made by the author) group (group W, CK). The parameters for assessing the preservation ability were levels of enzymes in freezed myocardial tissues (lactate, creatine kinase-MB and adenosine deaminase), coronary flow. left ventricular developing pressure and dpldt. In conclusion, the ability of preservation for isolated rabbit heart was excellent in CK solution and modified University of Wisconsin solution, and poor in modified Euro-collins solution, compared with Hartmann solution. CK solution has low potassium concentrations(34.2mEq/L) and includes various substrates to be salutary on myocardial preservation. This fact may indicates the necessity of further refinements in selection or composition of electrolytes and substrates.

  • PDF

A Study on $NO_x$ Reduction in a Light Duty Diesel Vehicle Equipped with a SCR Catalyst (선택적환원촉매를 적용한 중소형 경유차량의 질소산화물 저감 특성 연구)

  • Park, Young-Joon;Hong, Woo-Kyoung;Ka, Jae-Geum;Cho, Yong-Seok;Joo, Jae-Geon;Kim, Hyun-Ok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.5
    • /
    • pp.118-124
    • /
    • 2011
  • To reach the Euro-6 regulations of PM and $NO_x$ for light-duty diesel vehicles, it will be necessary to apply the CDPF and the de-$NO_x$ catalyst. The described system consists of a catalytic configuration, where the CDPF is placed downstream of the diesel engine and followed by a urea injection unit and a urea-SCR catalyst. One of the advantages of this system configuration is that, in this way, the SCR catalyst is protected from PM, and both white PM and deposits become reduced. In the urea-SCR system, the injection control of reductant is the most important thing in order to have good performance of $NO_x$ reduction. The ideal ratio of $NH_3$ molecules to $NO_x$ molecules is 1:1 based on $NH_3$ consumption and having $NH_3$ available for reaction of all of the exhaust $NO_x$. However, under the too low and too high temperature condition, the $NO_x$ reduction efficiency become slower, due to temperature window of SCR catalyst. And space velocity also affects to $NO_x$ conversion efficiency. In this paper, rig-tests were performed to evaluate the effects of $NO_x$ and $NH_3$ concentrations, gas temperature and space velocity on the $NO_x$ conversion efficiency of the urea-SCR system. And vehicle test was performed to verify control strategy of reductatnt injection. The developed control strategy of reductant injection was improved over all $NO_x$ reduction efficiency and $NH_3$ consumption in urea-SCR system. Results of this paper contribute to develop urea-SCR system for light-duty vehicles to meet Euro-5 emission regulations.