• Title/Summary/Keyword: ESS system

Search Result 539, Processing Time 0.026 seconds

Economical Analysis of the PV-linked Residential ESS using HOMER in Korea (HOMER를 이용한 PV 연계 가정용 ESS의 경제성 분석)

  • Eum, Ji-Young;Kim, Yong-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.36-42
    • /
    • 2019
  • Europe and North America are paying attention to residential ESS(Energy Storage System) that can manage energy efficiently. The ESS is a system that stores and manages the electric power by charging and discharging the battery. The ESS is generally used in conjunction with photovoltaic systems. The ESS supplies the load of the power generation time and stores the remaining PV power to supply the load at the non-power generation time. However, due to the high price of residential ESS, low electric rates and increasing block rates, there is no market of residential ESS in Korea. This paper reviews the price condition and the capacity for applying PV and residential ESS to household of apartments using HOMER in Korea.

A Study on Development of PV Charging Module for Home Using Master-Slave Method (Master-Slave 방식을 적용한 가정용 PV Charging Module 개발에 관한 연구)

  • Chung, Doyoung;Cha, Insu;Jung, kyunghwan;Kim, Sungmin;Kim, Rakjun;Kang, Byungbok
    • Journal of Energy Engineering
    • /
    • v.29 no.1
    • /
    • pp.44-51
    • /
    • 2020
  • The importance of ESS has been emphasized due to stabilization of power demand due to deterioration of network reliability and expansion of renewable energy sources. ESS (Energy Storage System) stores the remaining power and uses it when necessary to meet the power demand, and build the ESS system mainly in conjunction with solar and wind power. In this paper, we propose a home PV Charging Module using the Master-Slave method which is effective for low insolation. After designing the module, Fast MPPT algorithm is applied to generate the maximum output from the nonlinear output characteristics of the PV modules. The average power value for the input of PV Charging Module was 296.90 W and the output power was 289.60 W, which averaged 97.54%.

A Study on the Economic Analysis of ESS (ESS의 경제성 분석기법에 관한 연구)

  • Yoon, Young-Sang;Jeon, Weon-Young;Shin, Yong-Tae;Kim, Jong-Bae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.679-681
    • /
    • 2014
  • 에너지저장시스템(Energy Stroage System, ESS)은 잉여 전력과 에너지를 필요한 시점에 적절하게 공급할 수 있도록 에너지를 저장해두는 기술로 전기에너지의 픔질 및 효율성을 극대할 수 있는 에너지 활용 시스템이다. 미국을 비롯한 유럽 선진국들은 다양한 ESS 관련 제도정비 및 개선을 통해 ESS 산업의 활성화를 유도하고 있다. 우리나라의 경우, 신재생에너지 확대 정책을 수립하고 에너지 저장기술을 그린에너지 분야의 주요 핵심과제 선정하여 체계적인 육성전략을 추진 중에 있다. 그러나, ESS 도입 및 활성화를 위한 법제도적 기반이 마련되어 있지 않고, ESS도입에 대한 경제적 효과성에 대한 객관적인 기준이 없어, ESS의 보급 및 활성화가 제대로 이루어지지 않고 있는 실정이다. 본 연구에서는, ESS의 보급과 활성화를 위해 효과적으로 ESS의 경제성 분석하기 위한 기법을 제시하는 것을 목적으로 한다. 세부적으로는 전기요금 산정방식에 따라 ESS의 운영모형을 정의하고, 운영모형별 경제성을 분석하기 위한 기법을 제시한다. 그리고, 실제 데이터를 활용하여 ESS로 절감할 수 있는 피크 크기를 구할 수 있는 알고리즘을 구현한다. 또한, 저감 피크와 온도, 습도에 대한 회귀 분석을 통하여 최대저감피크를 예측할 수 있는 해법을 제시한다.

  • PDF

Analysis of Battery ESS Technology and its Effects for Generation Constraint (발전제약완화용 배터리 ESS 효과 분석 및 기술 적용)

  • Jung, Solyoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.45-50
    • /
    • 2021
  • 우리나라 서해안 및 동해안지역에는 대규모 발전단지가 집중되어 운영 중이며 이 발전단지들의 발전력을 송전하고 있는 765kV 송전선로 2 회선 고장이 발생하는 경우 송전선로의 용량부족으로 인해서 수 GW 규모의 발전력을 불시에 탈락시키도록 보호체계(SPS, Special Protection System)가 운영 중이다. 이 SPS 가 동작하여 대규모 공급능력이 불시에 상실되면 급격한 주파수 하락이 발생하게 되어 저주파수계전기(Under Frequency Relay, UFR)가 동작할 수 있기 때문에 SPS 탈락 발전기의 출력을 상시에 감소시키는 제약비발전(Constraint off)을 시행하고 있다. 이 제약비발전으로 인해 매년 수천억원의 제약비용이 발생하고 있기 때문에 제약을 완화시키기 위한 방안으로 배터리 에너지저장장치(BESS)를 적용하는 사업이 추진되고 있다. 이는 "발전제약완화 에너지저장장치(이하 발전제약완화용 ESS) 사업"으로 불리며 전국 19 개 변전소에 총 1.4GW(2C-Rate)의 에너지저장장치가 설치되는 국내 최대규모의 BESS 사업이다. 향후 송전망 확충에 의해서 발전제약이 해소되는 경우 주파수 조정용, 재생에너지 변동성 완화용 등의 다목적 ESS 로 활용될 계획이다. 본 보고서에서는 발전제약완화 ESS 사업의 기술적 효과를 실효치 기반의 시뮬레이션(PSS/E v33.3)을 통해서 검토하였다.

MG Operation Technique based on DC-Grid Stability using ESS (ESS를 활용한 DC-Grid 안정성 기반 MG 운영 기법)

  • Jong-Cheol Kim;Chun-Sung Kim;Yong-Un Park;Seong-Mi Park;Sung-Jun Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_3
    • /
    • pp.1269-1278
    • /
    • 2023
  • This paper presents an operational technique that can secure the stability of DC-Grid centering on MG operated based on ESS in multiple MG where three DC-based microgrid(MG) are interconnected. MG1(PV 600kWp, ESS 1.5MWh) has an 830Vdc grid voltage, MG2(PV 300kWp, ESS 1.1MWh) and MG3(PV 100kWp, ESS 500kWh) are DC-based MG with a 750Vdc grid voltage, and MG1 and MG2, 3 are linked by separate DC/DC converters (BTB). In order to keep different grid voltages stable, the power transmission capacity between MG1 and two MG(MG2, MG3) connected with an independent BTB converter was adjusted to secure the overall stability of the system, and this was verified by confirming that the surplus capacity of ESS was maintained in actual operation.

Study for the Relations between Electric Multiple Unit and Energy Storage System (에너지저장시스템과 도시철도 차량의 상관관계에 관한 연구)

  • Lee, Heui-Seon;Baek, Seoung-Gil;Kwon, Kyoung-Min;Kim, Gil-Dong
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2998-3006
    • /
    • 2011
  • This paper is about the relations between the electric multiple unit and ESS(Energy Storage system, here after) applying bi-direction Buck-Boost Converter. ESS may be possible to suppress the line voltage drops and the power loading fluctuations and to save the regeneration power lapses. This paper confirm for simulation that ESS reusing regenerative power generated during braking in train. Also, presents the influence of regenerative power variation of train and catenary acceptability for energy saving obtained by applying the ESS to Daejeon Metro line 1.

  • PDF

A Study of Economic ESS Utilization Based on Supplement Control Plan for Stable Wind Energy Extraction (풍력발전의 전력공급 안정화를 위한 ESS 보조제어 기법과 경제적 용량 산정 연구)

  • Jung, Seungmin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.22-28
    • /
    • 2018
  • In case of developing a combined system by a number of distributed resources with storage device, a number of application suggests a huge capacity can derive operational flexibility both power supply issues or when unexpected situation imposed. However, it is important to determine a resonable energy capacity because the device have many controversial cost issues in current power system industry. An ESS application which focusing essentially required points can induce appropriate storage capacity that required in economic operation. In this paper, a curtailment supporting algorithm based on storage device is introduced, and applied in the capacity calculation method. The main algorithm pursues handling minor exceeding quantities which can cause mechanical load at blade; This paper tries to include it for configuring hybrid algorithm with pitch control. Several fluctuating conditions are utilized in simulation to reflect critical situation. The analyzing process focuses on the control feasibility with applied capacity and control method.

Temperature-Dependent Electrochemical Characteristic Analysis for 10kW Li-Polymer Energy Storage System (ESS) (10kW급 에너지 저장장치(ESS)의 전기화학적 온도특성 분석)

  • Kim, J.H.;Choi, H.J.;Song, J.W.;Kim, S.J.;Park, J.P.
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.61-62
    • /
    • 2012
  • 본 논문에서는 10kW급 리튬계열 에너지 저장장치 (ESS;Energy storage system)의 전기화학적 온도특성을 분석하였다. 70개 $LiFePO_4$ 단위 셀의 직렬결합(70S1P)으로 이루어진 ESS의 온도특성 분석을 위해 여름(7월)과 겨울(1월)일때의 ESS Tray/Rack/Cell 전압(표준편차) 및 온도데이터(최대값/최소값)의 통계처리를 실시하였다. 실험결과를 통해, 주변 외기온도에 영향을 최소화한 안정적인 ESS의 최적구축을 위한 가이드 라인을 제시할 수 있다.

  • PDF

Attempt and Retry Estimation for the Quality-Control of Electronic Switching System (전자교환기 품질관리를 위한 발생 호수와 재시도 호수 추정)

  • Cha, Kyoung-Cheon;Jun, Duk-Bin
    • IE interfaces
    • /
    • v.18 no.3
    • /
    • pp.327-332
    • /
    • 2005
  • The call-attempt behavior in a telecommunications service is influenced by the launch of new services and the choice of subscribers. On Feb 28, 2005, there was a disastrous shut-down of major local electronic switching systems (ESS) due to an abrupt increase of call-attempts. This incident turned out to be a strong proof that appropriate forecasting attempts are necessary not only for the capacity planning of network but also for the quality control of ESS. In this paper, forecasting models are first developed to estimate the daily ESS call-attempts and user retrial rates and then meaningful interpretations of results will follow. Finally future research topics will be presented.

Study on payback period analysis of an ESS application (ESS 적용에 따른 원금회수 기간 분석에 관한 연구)

  • Chai, Hui-Seok;Kang, Byoung-Wook;Hong, Jong-Seok;Moon, Jong-Fil;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.611-612
    • /
    • 2015
  • Prediction algorithm of the energy storage system in accordance with the load pattern can cause economic loss in case of a failure prediction. In this paper, we compare the electricity charge between industrial power system with ESS - this case's operation is based on Non-prediction operation method. - and without ESS. In addition, we derive the payback period.

  • PDF