• Title/Summary/Keyword: ERV

Search Result 31, Processing Time 0.024 seconds

Identification and Expression Analyses of Equine Endogenous Retroviruses in Horses

  • Gim, Jeong-An;Kim, Heui-Soo
    • Molecules and Cells
    • /
    • v.40 no.10
    • /
    • pp.796-804
    • /
    • 2017
  • Endogenous retroviruses (ERVs) have been integrated into vertebrate genomes and have momentously affected host organisms. Horses (Equus caballus) have been domesticated and selected for elite racing ability over centuries. ERVs played an important role in the evolutionary diversification of the horse genome. In the present study, we identified six equine ERV families (EqERVs-E1, I1, M2, P1, S1, and Y4), their full-length viral open reading frames (ORFs), and elucidated their phylogenetic relationships. The divergence time of EqERV families assuming an evolutionary rate of 0.2%/Myr indicated that EqERV-S3 (75.4 million years ago; mya) on chromosome 10 is an old EqERV family and EqERV-P5 (1.2 Mya) on chromosome 12 is a young member. During the evolutionary diversification of horses, the EqERV-I family diverged 1.7 Mya to 38.7 Mya. Reverse transcription quantitative real-time PCR (RT-qPCR) amplification of EqERV pol genes showed greater expression in the cerebellum of the Jeju horse than the Thoroughbred horse. These results could contribute further dynamic studies for horse genome in relation to EqERV gene function.

Energy Saving Effect of ERV(Energy Recovery ventilator) with Economizer Control in Residential Building (Economizer cycle control을 채용한 전열교환시스템의 에너지 절감효과 분석 -국내 공동주택을 대상으로-)

  • Park, Jae-Hyung;Kim, Joo-Wook;Song, Doo-Sam;Yoon, Ho-Young;Kim, Sung-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.679-684
    • /
    • 2009
  • ERV system has installed in almost newly constructed residential building in Korea. Heat recovery features of ERV can be possible to decrease the heating and cooling load caused by ventilation. However, in case of the outdoor condition is favorable to control the indoor air, the heat recovery function of ERV does more harm than good in term of cooling load. In this study, the ERV with economizer cycle control for residential building is suggested and the performance of the suggested system will be analyzed using TRNSYS.

  • PDF

Heat Transfer and Sterilization Characteristics of an ERV Element Made of Hwang-to Paper (황토지로 제작된 전열교환소자의 전열특성 및 항균특성에 관한 연구)

  • Cho, Min-Chul;Oh, Sai-Kee;Ahn, Young-Chull
    • Journal of Power System Engineering
    • /
    • v.21 no.1
    • /
    • pp.50-56
    • /
    • 2017
  • To increase the enthalpy exchange efficiency of ERV elements, the moisture exchange character must be improved. The moisture exchange efficiency depends on material characteristics. The material used for ERV is Hwang-to paper based on Han-ji which is Korean traditional paper. The paper has excellent performance in moisture exchange and heat transfer compared with polymer and other papers. To have an anti bacteria performance and to improve moisture exchange performance of Han-ji, Hwang-to is added to the Han-ji. The enthalpy exchange efficiency of the Hwang-to paper shows 5% greater than that of the conventional paper. In case of Escherichia Coli, the reduction rate of bacteria is 96.6% and in case of Pseudomonas, the reduction rate of bacteria is 97.5%. The ERV element made of Hwang-to paper has a great possibility as an ERV element.

Expression of Endogenous Retroviruses and Disease (내인성 레트로바이러스의 발현과 질병)

  • Lee, Jae-Yeong
    • Korean Journal of Microbiology
    • /
    • v.43 no.4
    • /
    • pp.237-242
    • /
    • 2007
  • One of the chief characteristics of the retrovirus life cycle is the appearance of provirus caused by integration of viral genome into the host cell genome, and its delivery stably to the next generation as a part of host germ line. This stable form is called endogenous retrovirus (ERV) and expressed by exogenous or endogenous factors. HERVs and MuERVs are present in humans and mice correspondingly, and their expressions frequently cause diseases. Several diseases such as cancer, autoimmunity and neurological disorders are related with HERVs. Therefore, various strategies should be established for the development of effective therapies for the suffering patients.

Energy Saving Effect of ERV(Energy Recovery Ventilator) with Economizer Cycle - Focused on the School Buildings - (Economizer cycle을 채용한 전열교환형 환기시스템의 에너지 절감 효과 분석 -국내 학교를 대상으로-)

  • Kim, Joo-Wook;Park, Jae-Hyung;Song, Doo-Sam;Chu, Euy-Sung;Kwon, Young-Chul
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.695-700
    • /
    • 2009
  • Maintaining an IAQ with fresh in school building is very important because the good IAQ can be possible to improve the academic performance. Since school buildings are very dense and require a lot of fresh air, the need for ERV(Energy Recovery Ventilator) has become obvious. While opening a window does provide ventilation, the building's heat and humidity will then be lost in the winter and gained in the summer, both of which are undesirable for the indoor climate and for energy efficiency. ERV technology offers an optimal solution: fresh air, better climate control and energy efficiency. However, when the outdoor air condition is favorable to control the indoor environment such as spring and autum in Korea, heat exchange in ERV would rather increase the cooling load than diminish. Economizer cycle control which using the outdoor air in controlling the indoor thermal environment has many benefit in terms of energy saving and IAQ control. In this study, the ERV with economizer cycle control will be suggested. And then the system control characteristics and energy saving effect will be analyzed through the TRSNSYS Simulation.

  • PDF

Energy Saving Effect of the Night Purge Control using ERV in a School Building (전열교환형 환기시스템을 이용한 학교건물의 나이트 퍼지 적용 효과 분석)

  • Kim, Su-Yeon;Won, Jung-kwan;Kim, Jae-Hyung;Song, Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.11
    • /
    • pp.421-427
    • /
    • 2016
  • The indoor temperature of a building increases during the day due to solar radiation. This behavior is significant in school buildings that are finished with high thermal capacity materials. Moreover, in school buildings, windows cannot be opened until the class has finished owing to the security policy of schools. Consequently, classrooms maintain a high temperature throughout the morning. It is thus important to remove the indoor heat before the commencement of classes in order to reduce the cooling energy needed. The Energy Recovery Ventilator (ERV) system is currently being installed in school buildings for ventilating the classrooms. Night-purge control using ERV can be a good strategy to cool the classroom in advance of the operation of the cooling system. However, the optimal operation method of the ERV for night-purge control has not yet been reported. In this study, the effect of night-purge control with ERV in school buildings is analyzed by simulation method. The results of this study showed that the energy saving effect of night-purge control with ERV is most effective in the case of 2 hours operation prior to the commencement of the first lass and when enthalpy based outdoor air cooling is used.

Effects of Feedback Respiratory Exercise and Diaphragm Respiratory Exercise on the Pulmonary Functions of Chronic Stroke Patients

  • Seo, Kyo Chul;Kim, Hyeon Ae;Lim, Sang Wan
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.3 no.2
    • /
    • pp.458-463
    • /
    • 2012
  • This study is to examine the effects of a feedback breathing device exercise and diaphragm breathing exercise on pulmonary functions of chronic strokes patients. The selection of 20 subjects was divided equally and placed into a experiment group and a control group and the intervention was applied four times per a week for five weeks. In each session, both groups received rehabilitative exercise treatment for 30 minutes, and a feedback breathing device exercise for 15 minutes. In addition, experimental group conducted a combination of diaphragm breathing exercise for 15 minutes. Prior to and after the experiment, patients' pulmonary functions were measured using a spirometer. The pulmonary function tests included FVC, FEV1, FEV1/FVC, PEF, VC, TV, IC, ERV, IRV. With respect to changes in the pulmonary functions of both groups, the experimental group significantly differed in FVC, FEV1, TV, ERV but did not in PEF, FEV1/FVC, VC, IRV. The control group did not significantly differ in any of the tests. There were significant differences in FEV1, FEV1/FVC, TV, ERV between the two groups, but no significant differences in FVC, PEF, FEV1/FVC, VC, IRV between them after the experiment. The experimental group, which conducted a combination of a feedback breathing device exercise and diaphragm breathing exercise, saw their respiratory ability increase more significantly than the control group. The breathing exercise was found to improve pulmonary function in chronic stroke patients.

Comparison of Posture on Respiratory Function in the Stroke Patients according to Changes of Position (뇌졸중 환자의 자세변화에 따른 폐기능비교)

  • Seo, Kyo-Chul;Lee, Sung-Eun;Lee, Jeon-Hyeong;Kim, Kyoung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.381-389
    • /
    • 2011
  • Purpose : The purpose of this study was to compare the respiratory function in the different body position of the stroke patients. Methods : Twenty patients with stroke patients group(M:12, F:8) and twenty control group(M:12, F:8) were participated in experiment. Strokes patients group and control group were assessed according to position changes(supine position, $45^{\circ}$ sitting position, $90^{\circ}$ sitting position) using pulmonary function(vital capacity, inspiratory capacity, tidal volume, expiratory reserve volume, inspiratory reserve volume). Results : These findings suggest that supine position in stroke group and control group were significant difference in IC, VC, IRV, ERV(p<.05). $45^{\circ}$ lean sitting position in stroke group and control group were significant difference in IC, VC, ERV(p<.05). 90 sitting position in stroke group and control group were significant difference in VC, IRV, ERV(p<.05). In comparison of two groups, strokes group was more low pulmonary function than normal group. Conclusion : This study showed pulmonary function was more high normal groups than stroke groups. And $90^{\circ}$ sitting position was high pulmonary function than supine position, $45^{\circ}$ lean sitting position. Thus it indicates that the functions will be suggest the objective data of patients with strokes for respiratory function.

Effects of Breathing Exercise in the Water on Pulmonary Function and Maximum Phonation Time of Children with Cerebral Palsy (수중에서 호흡운동이 뇌성마비 아동의 폐기능 및 최대발성시간에 미치는 영향)

  • Lee, Je-Wook;Hwangbo, Gak
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.3
    • /
    • pp.91-107
    • /
    • 2019
  • PURPOSE: This study examined the effects of breathing exercise in the water on the pulmonary function and maximum phonation time in children with cerebral palsy. METHODS: The subjects were 24 children with cerebral palsy at GMFCS levels I-III, who were allocated randomly to either the aquatic breathing exercise group or general breathing exercise group 12 subjects per group. Each subject was required to complete 40 minutes of exercise twice a week for eight weeks. Those in the aquatic breathing exercise group performed aquatic breathing exercise, whereas those in the general breathing exercise group performed general aquatic exercise. RESULTS: Significant differences in $FEV_1$, PEF, VC, TV, ERV, and maximum phonation time were observed in the aquatic breathing exercise group after intervention, but there were no significant differences in either FVC, $FEV_1/FVC$, IC, or IRV. In the general breathing exercise group, there were no significant differences in the FVC, $FEV_1$, $FEV_1/FVC$, PEF, VC, IC, TV, IRV, ERV, and maximum phonation time after intervention. In terms of the pulmonary function, the two groups showed a significant difference in the change in $FEV_1$, PEF, and TV after intervention, but not in the FVC, $FEV_1/FVC$, VC, IC, ERV, IRV, and maximum phonation time. CONCLUSION: These results above show that aquatic breathing exercise training in water is more effective in improving the pulmonary function than general breathing exercise training.