Development of Management Guidelines and Procedure for Anthropometric Suitability Assessment: Control Room Design Factors in Nuclear Power Plants

  • Lee, Kyung-Sun;Lee, Yong-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.1
    • /
    • pp.29-43
    • /
    • 2015
  • Objective: The aim of this study is to develop management guidelines and a procedure for an anthropometric suitability assessment of the main control room (MCR) in nuclear power plants (NPPs). Background: The condition of the MCR should be suitable for the work crews in NPPs. The suitability of the MCR depends closely on the anthropometric dimensions and ergonomic factors of the users. In particular, the MCR workspace design in NPPs is important due to the close relationship with operating crews and their work failures. Many documents and criteria have recommended that anthropometry dimensions and their studies are one of the foremost processes of the MCR design in NPPs. If these factors are not properly considered, users can feel burdened about their work and the human errors that might occur. Method: The procedure for the anthropometric suitability assessment consists of 5 phases: 1) selection of the anthropometric suitability evaluation dimensions, 2) establishment of a measurement method according to the evaluation dimensions, 3) establishment of criteria for suitability evaluation dimensions, 4) establishment of rating scale and improvement methods according to the evaluation dimensions, and 5) assessment of the final grade for evaluation dimensions. The management guidelines for an anthropometric suitability assessment were completed using 10 factors: 1) director, 2) subject, 3) evaluation period, 4) measurement method and criteria, 5) selection of equipment, 6) measurement and evaluation, 7) suitability evaluation, 8) data sharing, 9) data storage, and 10) management according to the suitability grade. Results: We propose a set of 17 anthropometric dimensions for the size, cognition/perception action/behavior, and their relationships with human errors regarding the MCR design variables through a case study. The 17 selected dimensions are height, sitting height, eye height from floor, eye height above seat, arm length, functional reach, extended functional reach, radius reach, visual field, peripheral perception, hyperopia/myopia/astigmatism, color blindness, auditory acuity, finger dexterity, hand function, body angle, and manual muscle test. We proposed criteria on these 17 anthropometric dimensions for a suitability evaluation and suggested an improvement method according to the evaluation dimensions. Conclusion: The results of this study can improve the human performance of the crew in an MCR. These management guidelines and a procedure for an anthropometric suitability assessment will be able to prevent human errors due to inadequate anthropometric dimensions. Application: The proposed set of anthropometric dimensions can be integrated into a managerial index for the anthropometric suitability of the operating crews for more careful countermeasures to human errors in NPPs.

Clinical Nutrition Service in Korean Tertiary Hospitals and General Hospitals: Result of Nationwide Cross-Sectional Survey (국내 상급종합병원과 전국 분포 종합병원의 임상영양서비스 실태 조사 연구: 전국 규모 설문조사를 통하여)

  • Um, Mi Hyang;Park, Yoo Kyung;Lee, Song Mi;Lee, Seung Min;Lee, Eun;Cha, Jin A;Park, Mi Sun;Lee, Ho Sun;Rha, Mi Yong;Lyu, Eun Soon
    • Journal of the Korean Dietetic Association
    • /
    • v.20 no.3
    • /
    • pp.183-198
    • /
    • 2014
  • The purpose of this study was to investigate the status of clinical nutrition services provided at tertiary hospitals and general hospitals in Korea. In total, 157 questionnaires were distributed to the departments of nutrition at hospitals on September 2013. The results of this study are as follows. The median number of beds was 607 and average length of stay was 8 days. 63.1% of dietitians had over 5 years of career experience. Nutritional screening rate was 97% in tertiary hospitals but only 67.2% in general hospitals (P<0.001). The rate of equipment with computerized nutritional screening system was 100% in tertiary hospitals but 71.9% in general hospitals (P<0.001). Hospitals with the best regarding nutritional care were hospitals accredited by JCI (Joint Commission International). On the other hand, hospitals not accredited by the JCI but KOIHA (Korea Institute for Healthcare Accreditation) showed the lowest performance rate of nutritional care. Nutrition support teams (NSTs) were established in all tertiary hospitals but in only 73% of general hospitals (P<0.001). The rate of actively operating NSTs was 89% in tertiary hospitals but only 62% in general hospitals (P<0.001). There is a need to provide proper standardized clinical nutrition services as a primary treatment and we observed large variations in the quality of nutritional service between hospitals. Therefore, local solutions are needed to implement nutritional programs and policies for improved service and care.

A study on the monitoring of high-density fine particulate matters using W-station: Case of Jeju island (W-Station을 활용한 고밀도 초미세먼지 모니터링 연구: 제주도 사례)

  • Lee, Jong-Won;Park, Moon-Soo;Won, Wan-Sik;Son, Seok-Woo
    • Particle and aerosol research
    • /
    • v.16 no.2
    • /
    • pp.31-47
    • /
    • 2020
  • Although interest in air quality has increased due to the frequent occurrence of high-concentration fine particulate matter recently, the official fine particulate matter measuring network has failed to provide spatial detailed air quality information. This is because current measurement equipment has a high cost of installation and maintenance, which limits the composition of the measuring network at high resolution. To compensate for the limitations of the current official measuring network, this study constructed a spatial high density measuring network using the fine particulate matter simple measuring device developed by Observer, W-Station. W-Station installed 48 units on Jeju Island and measured PM2.5 for six months. The data collected in W-Station were corrected by applying the first regression equation for each section, and these measurements were compared and analyzed based on the official measurements installed in Jeju Island. As a result, the time series of PM2.5 concentrations measured in W-Station showed concentration characteristics similar to those of the environmental pollution measuring network. In particular, the results of comparing the measurements of W-Station within a 2 km radius of the reference station and the reference station showed that the coefficient of determination (R2) was 0.79, 0.81, 0.67, respectively. In addition, for W-Station within a 1 km radius, the coefficient of determination was 0.85, 0.82, 0.68, respectively, showing slightly higher correlation. In addition, the local concentration deviation of some regions could be confirmed through 48 high density measuring networks. These results show that if a network of measurements is constructed with adequate spatial distribution using a number of simple meters with a certain degree of proven performance, the measurements are effective in monitoring local air quality and can be fully utilized to supplement or replace formal measurements.

Comparative Analysis on Competitiveness between Ports in Northeast Asia Employing Shift-share Analysis and DEA (변이할당기법과 DEA를 활용한 동북아시아 항만간 경쟁력 비교 분석)

  • Lee, Choongbae;Kwon, A Rim
    • Journal of Korea Port Economic Association
    • /
    • v.30 no.4
    • /
    • pp.219-254
    • /
    • 2014
  • Due to the recent development of globalization and supply chain management, growth of international trade has led to increasing cargo volume around the world. Since maritime logistics environments have changed, increased container ship size, improvement of harbor equipment, global port operation and rapid technological development have had an significant effects on shipping and port industry, which is contributing to competitiveness of port. Since a larger volume of port throughputs are generally regarded as an indicator of the more competitive port, inefficient port operation could reduce its competitiveness. On the other hand, high efficient ports could increase their competitive power while increasing cargo volume. This study aims at comparing competitiveness of the ports in the Northeast Asia by investigating changes of container throughputs and evaluating efficiency performance of ports. Shift-Share analysis and Data Envelopment Analysis(DEA) have been conducted with 21 Northeast Asian ports and then separated them into 4 groups for comparative analysis to identify competitive position of each port. The results of this study show that Incheon and Gwangyang port have been decreased container cargo volume, while volume of Busan port would increase by means of active marketing, various route development and incentive policy for the port.

A Study on Characteristics of Exhaust Gas Emissions of Water-Bunker Oil Mixed by Homogenizer (균질기에 의해 혼합된 물-벙커유의 배기가스 배출 특성에 관한 연구)

  • Choi, Jung-Sik;Han, Sang-Goo;Choi, Jae-Hyuk;Park, Sang-Kyun;Park, Ro-Seong;Kim, Dae-Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.5
    • /
    • pp.518-524
    • /
    • 2013
  • In this study, we conducted a study on characteristics of exhaust gas emissions from boiler when water-bunker oil mixed by homogenizer was burned in boiler. The results showed that NOx concentration and CO concentration of the homogenized bunker oil was decreased by 19% and 54% compared to pure bunker oil pretreatment was not being performed. And, in the case of water-bunker A oil, the NOx concentration was decreased with increasing water mixing ratio in bunker A oil. In particular, the NOx concentration in exhaust gas of 20 %water-80 %bunker A oil decrease by 45 % compared with pure bunker-A. However, the CO concentration in exhaust gas of 20 %water-80 %bunker A oil shows irregular changes. This means that the mixing of water more than a certain amount can cause a decrease in combustion performance. From this result, it can be found that critical mixing ratio of water in bunker A oil for normal combustion is 15% in this study. Deposition amount of soot that is collected in the vicinity of the chimney was decreased with increasing water mixing ratio.

Reactive Power Variation Method for Anti-islanding Using Digital Phase-Locked-Loop (DPLL을 이용한 능동적 단독운전방지를 위한 무효전력변동법)

  • Lee, Ki-Ok;Yu, Byung-Gu;Yu, Gwon-Jong;Choi, Ju-Yeop;Choy, Ick
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.64-69
    • /
    • 2008
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. There has been an argument that it may be a non-issue in practice because the probability of islanding is extremely low. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an islanding can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficiently to cause a trip, plus the time required to execute a trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. Third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an islanding. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. Therefore the verification of anti-islanding performance is strongly needed. In this paper, improved RPV method is proposed through considering power quality and anti-islanding capacity of grid-connected single-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation results are verified.

Establishment of Dissolution Specifications for Generic Drugs in Korea Pharmaceutical Codex Monograph - Nicametate Citrate Tablet, Norfloxacin Capsule (고시 수재 의약품의 용출규격 설정 - 구연산니카메테이트 정, 노르플록사신 캡슐)

  • Kim, Hee-Yun;Choi, Seon-Hee;Bang, Su-Jin;Han, Kyung-Jin;Choi, Sung-Hee;Baek, Ji-Yun;Kim, Dong-Sup;Kim, Young-Ok;Sohn, Kyung-Hee;Song, Young-Me;Sah, Hong-Kee;Choi, Hoo-Kyun
    • YAKHAK HOEJI
    • /
    • v.54 no.5
    • /
    • pp.362-369
    • /
    • 2010
  • Despite the fact that the dissolution test can serve as an effective tool for drug quality control and prediction of in vivo drug performance, there are a number of drugs with no established dissolution specifications because they were developed quite a long time ago. Under this circumstances, KFDA started the new project that establishes dissolution method and specifications for drugs with no dissolution specifications listed in the Korea Pharmaceutical Codex (KPC). This project aims for promoting the appropriate management of oral solid dosage forms. Seoul regional KFDA selected 2 items, Nicametate citrate tablet and Norfloxacin capsule, for establishing dissolution specifications. We went through the following procedures to develop the dissolution method and specifications: (1) Validation of dissolution test equipment, (2) Purchase of test drugs, (3) Preliminary test with one of the test products (1 lot), (4) Validation of analysis methods (3 lots), (5) Final tests and cross tests among other laboratory to establish dissolution specifications, (6) Additional test with the other test drugs. The outcome of this study will be reflected in revision of the KPC. It is believed that the quality control and evaluation of oral solid dosage forms listed in KPC will be advanced with the revision which adds additional dissolution test and specifications for the drugs with no established dissolution specifications.

Real-Time Construction Resource Monitoring using RFID/USN Inter-working System (RFID/USN 연동 시스템을 활용한 건설자원 실시간 모니터링 시스템)

  • Ryu, Jeoung-Pil;Kim, Hyoung-Kwan;Kim, Chang-Yoon;Kim, Chang-Wan;Han, Seung-Heon;Kim, Moon-Kyum
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.90-94
    • /
    • 2007
  • Location tracking automation of resources in construction industry is one of the most important procedures to improve construction project performance and reduce the period of construction. Recently, location tracking technologies have proven to be effective in tracking construction materials and equipment in real time through the instrumentality of RFID (Radio Frequency Identification). By using wireless communication and inter-working system between RFID and USN, it is possible that construction engineers receive the location information of construction resources without additional efforts that move the RFID reader to read tags periodically. In the inter-working system, RFID reader delivers the acquired materials information to sensor node which is connected by serial interface. Then sensor node transmits the received data to the data aggregation terminal that is a sink node. The data aggregation terminal can transmit collected data to construction manager who is out of construction site using infrastructure such as CDMA(Code Division Multiple Access) network. The combination model of the two system and field test scenarios are presented in this paper.

  • PDF

A Frame Stress and Integration Monitoring System based on Continuous Track Type for Multipurpose Application of Electric Wheelchair (전동휠체어의 다목적 활용을 위한 무한궤도형 기반의 프레임 응력 및 통합 모니터링 시스템)

  • Jo, Kyeong-Ho;Jung, Se-Hoon;Park, Jae-Sung;Yoo, Seung-Hyun;Sim, Chun-Bo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.1135-1144
    • /
    • 2018
  • An electric wheelchair used to be utilized as a piece of equipment for the disabled and the elderly in the past, but the recent changes to its functions and forms have made it available across various fields and purposes. In this paper, we propose a continuous track type of electric wheelchair prototype to be used in various fields and environments and a monitoring system to control it. A frame stress design was applied to improve its stability during driving compared with the previous wheelchairs. In addition, we provide a convenience for free and easy operation of them using the App. based on android. A monitoring system based on C# was also added to control a large number of electric wheelchairs. As a result of the implementation and performance evaluation, the von Mises stress value was measured 4.401% within the normal range through five times of stress interpretations, and its accuracy of communication for system manipulation was recorded about 98.75%, which means that it has been proven to be safer than the previous wheelchairs.

A Study on Protection Depending on Mesh Size of Expanded Metal for Slope Reinforcement (사면보강용 Expanded Metal 격자크기에 따른 인발 특성 연구)

  • Ji, Younghwan;Kim, Kihwan;Kim, Sungho;Hwang, Yeongcheol;Lee, Seungho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.12
    • /
    • pp.47-56
    • /
    • 2010
  • The construction of new roads and the consistent extension of already-existing roads or the line-shape revision of those roads are increased with the governmental investment to SOC facilities currently. Accordingly, the road cut slopes are in the trend of rapidly increasing. As the road slope has increased, a lot of human and property damages has entailed consequently and in the local case, numerous studies have carried out aiming at minimizing this damages caused by the rockfall and landslide. In general, standard falling rock prevention facility has employed for most of the local road slope based on "Guide for Installation and Management of Road Safety Facilities" published by MLTM(the Ministry of Land, Transport, and Maritime Affairs) but profound doubt has raised as to whether this rockfall prevention facility would function properly enough to prevent rockfall efficiently without any damages in case of actual occurrence of rockfall. In addition, it is a reality that in most cases, such work is relied on overseas technology as a whole as the local technical level is low and in case of rockfall prevention net, it is judged that a study on rockfall prevention net that is able to endure more powerful rockfall energy is required as the problem including net bursting is taken place as a result of enough bearing force being failed to be demonstrated due to its partial weak point(not uniformly made). Under this background, in this study, three kinds of model depending on mesh size of expanded metal that is considered to have an adoptability as rockfall prevention net, as target are selected and characteristics depending on mesh size of expanded metal is intended to be researched through a pull-out test performance by using pull-out test equipment rockfall prevention net.