• Title/Summary/Keyword: EPA SWMM5

Search Result 17, Processing Time 0.032 seconds

Flood Inundation Analysis using XP-SWMM Model in Urban Area (XP-SWMM 모형을 적용한 도시지역의 침수해석)

  • Lee, Jong-Hyeong;Yeon, Kee-Seuk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.5
    • /
    • pp.155-161
    • /
    • 2008
  • The flood damage shows different types in natural river watershed and in urban drainage watershed. In recent, increasing of the impervious area gives rise to short concentration time and high peak discharge comparing with natural watershed and it is a cause of urban flood damage. In this paper, we use a XP-SWMM model developed based on EPA-SWMM version for analyzing the inundation area, inundation depth and inundation area considering building effect. The two events(2005.06, 2005.07) has been used for the validation of model. HEC-RAS model has been applied for simulation of changing water level, and the results has been used for calculating area of the inundation. The observed inundation area(21.41 ha) in August, 1998 was in good agreement with the simulated value(23.45 ha) of XPSWMM model. An influence of inundation area considering building effects has been analized by the DTM of XP-SWMM model.

Introduction of Decision Support System for Design of Low Impact Development Based on SWMM5.1: WMAM (SWMM5.1을 기반으로 한 저영향개발 시설의 설계를 위한 의사결정지원시스템: WMAM)

  • Song, Jae Yeol;Chung, Eun-Sung;Kim, Soo-Hyun;Lee, Sang-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.321-321
    • /
    • 2016
  • 도시화와 토지이용 변화로 인하여 도시지역의 불투수면적이 증가하고 있으며, 이로 인해 발생하는 홍수, 가뭄, 수질악화 등의 해결은 수자원 계획 및 관리에 있어서 중요한 과제이다. 저영향개발(LID, Low Impact Development) 기법은 물 순환 체계를 복원할 수 있는 대안으로 도시지역에서 물 관리를 통해 하천 복원 및 수자원 관리를 가능하게 해주는 기술로써, EPA SWMM의 업그레이드 버전에서는 저영향개발 기술과 관련된 시설의 설계를 통한 유출 모의가 가능해졌다. 그러나 SWMM 모형 내에서 저영향개발 시설을 설계 및 계획하기 위해서는 저영향시설과 관련된 다양한 매개변수들을 입력해야하며, 효과적인 시설의 설계를 위해서는 반복적인 모의 수행이 동반된다. 이에 본 연구에서는 SWMM 모형을 기반으로 저영향개발 시설의 설계를 위한 의사결정지원시스템인 WMAM(Water Management Analysis Module)을 개발하였다. WMAM은 저영향개발 시설과 관련된 다양한 매개변수 중에서 최종 유출량에 영향을 미치는 매개변수의 추출이 가능하다. 또한, 저영향개발 시설의 설계 및 계획 매개변수에 대한 다양한 시나리오를 생성하고, 짧은 시간에 동시에 모의 분석을 수행하여 수문학적 측면에서 효과적인 시나리오를 도출해준다. 본 연구에서는 WMAM의 효과성을 보여주고자 A대학교를 모델링한 SWMM 모형에 저영향개발 시설 중 하나인 침투트렌치의 (1)계획 전과 (2)계획 후, 그리고 (3)WMAM을 적용하였을 경우의 첨두유량과 침투손실 결과를 비교하였다. 침투트렌치 설치 전의 첨두유량은 약 0.48 CMS로 세가지 경우 중 가장 높은 값을 보였으며, 침투트렌치 설지 후와 WMAM을 활용한 경우의 첨두유량은 점차 낮아졌다. 또한, 침투손실량을 보면 설치전에는 약 0.28 m로 가장 낮았으며, 설치 후 그리고 WMAM을 활용하였을 경우는 점차 그 값이 높아졌다. 본 연구를 통해, WMAM이 저영향개발 시설의 설계 및 계획에 있어서 수문학적으로 효과적인 결과를 보이는 것을 확인할 수 있었으며, 향후 보완과 추가 개발을 통해 수자원 계획 및 관리에 있어서 유용한 프로그램이 될 수 있을 것으로 기대된다.

  • PDF

The Water Circulation Improvement of Apartment Complex by applying LID Technologies - Focused on the Application of Infiltration Facilities - (LID 기술 적용을 통한 공동주택단지 물순환 개선 연구 - 침투시설 적용을 중심으로 -)

  • Suh, Joo-Hwan;Lee, In-Kyu
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.5
    • /
    • pp.68-77
    • /
    • 2013
  • Change in the Global Climate causes flood, drought, heavy snow, and rainfall patterns in the Korean Peninsula. A variety of alternatives related to climate change are considered. The foreign researchers are interested in Low Impact Development(LID); the utilization of water resources and eco friendly development, over 10 years ago. The research and development of related technology has been advanced to apply LID techniques in order to develop several projects in the country. However, sharing of technology or system that can be used easily in the private sector is insufficient. The performance of the elements of LID Technology has not been fully agreed. LID elements of this technology are easy to apply to Apartment complex. The elements are classified technology. The infiltration of elements performs the functions of apartment complex landscaping space technology applied to the target. The water cycle simulation(SWMM 5.0) and technology the implementation of the effectiveness is also verified. For this purpose, three different places in apartment complex to target by SWMM5.0 U.S. EPA conducted utilizing simulated rainfall and applying LID techniques before and after the simulated water cycle (infiltration, surface evaporation, and surface runoff) were conducted. The importance of green space in the LID techniques of quantitative and qualitative storm water control as well as the role of Apartment Housing is to promote Amenity. Remember that the physical limitations of apartment complex and smooth water circulation system for the application of LID integrated management techniques should be applied. To this end, landscapes, architecture, civil engineering, environmental experts for technical consilience between the Low Impact Development efforts are required.

Analysis of Runoff Reduction with LID Adoption using the SWMM (SWMM을 이용한 춘천 거두 1지구의 LID 개념 적용으로 인한 유출 감소 특성 분석)

  • Park, Junho;Yoo, Yonggu;Park, Youngkon;Yoon, Heetaek;KIm, Jonggun;Park, Younshik;Jeon, Ji-Hong;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.806-816
    • /
    • 2008
  • In recent years, increases in impervious areas with rapid urbanization and land use changes are causing numerous hydrologic and environmental problems. In this study Low Impact Development (LID) was applied to investigate changes in runoff and peak runoff with LID plans. SWMM 5.0 was used to simulate LID Integrated Management Practices (IMPs) at study area. The SWMM estimated total runoff volume with conventional land use planning is (82.3%, 46.44 mm), (99%, 73.16 mm) greater than total runoff before urbanization, while total runoff with LID is (11.1%, 46.44 mm), (49%, 73.16 mm) greater than those before urbanization. With the LID adoption in land use planning, pervious area increases by 49.8% compared with that from the conventional urban land use planning, resulting in (32.7%, 46.44 mm), (23.6%, 73.16 mm) decrease in total runoff, and (32.6%, 46.44 mm), (18.5%, 73.16 mm) decreases in peak rate runoff. The results obtained from this study indicate that peak rate runoff, time to peak, and total runoff can be reduced with the LID in urban land use planning because the LID secures pervious areas with various LID IMPs. The SWMM simulated result using design storm data and the US EPA suggested CN values for various LID IMPs implies that how environment-friendly urban land use planning with the LID adoption is important for sustainable development at urbanizing watershed.

Development of Grid based Inundation Analysis Model (GIAM) (격자기반 침수해석모델(GIAM) 개발)

  • Lee, Byong Ju;Yoon, Seong Sim
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.3
    • /
    • pp.181-190
    • /
    • 2017
  • Population congestion and increasing porosity caused by urbanization and increasing rainfall intensity are the main reasons for urban inundation damage. In order to reduce the damage to urban flooding, it is necessary to take a inundation analysis model that can be considered the topographic impact (i.e., building and road) and simulate the detailed inundation areas. In this study, Grid based Inundation Analysis Model (GIAM) is developed using a two-dimensional shallow water equations. The study area is Gangnam basin, with a surface area of $7.4km^2$, which includes 5 drainage areas such as Nonhyun, Yeoksam, Seocho 1, 2, and 3. EPA SWMM5 is used for simulating the overflows at each manhole. GIAM model is constructed to allow for simulating a inundation area with 6 m grid size. The inundation analysis is conducted in two heavy rainfall events (Sep. 21, 2010 and July 27, 2011) for the model evaluation. The accuracy of the simulated inundation area is calculated 0.61 and 0.57 at POD index using the historical flooded area report. The developed model will be used as a tool for analyzing the flood prone areas based on rainfall scenario, and a tool for predicting the detailed inundation area in the real-time.

Determination of Optimal Reservoir Locations Using Multi-Objective Genetic Algorithm (다목적 최적화 알고리즘의 적용을 통한 우수저류조 최적 설치지점 선정기법의 제안)

  • Park, Cheong-Hoon;Hoa, Ho Van;Lee, Seung-Yub;Kim, Joong-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.637-637
    • /
    • 2012
  • 본 연구에서는 내수침수 저감을 위하여 효율적(effective)인 우수저류조 설치에 따른 침수저감효과 극대화 방안을 제시하고자 한다. 여기서 효율성(effectiveness)은 침수저감량의 극대화 측면과 비용의 최소화 측면 두 가지로 구분된다. 최적 방재 시설물의 설치는 단순 설치비용 대비 저감량이 가장 큰 안을 제시하는 것은 의미가 없으며 일정 기준 이상의 방재성능을 발휘하면서 주어진 예산안에서 최적안을 찾아야 하므로 비용의 최소화 측면과 침수 저감량, 즉 맨홀에서의 월류 저감량을 최대화 하는 두 가지의 목적을 동시에 달성해야 한다. 따라서 본 연구에서는 다목적 최적화 알고리즘의 적용을 통하여 우수저류조 최적 설치지점을 선정하는 기법을 제안하였다. 본 연구에 적용한 다목적 최적화 방법으로는 목적함수의 최적해 탐색 효용성 측면에서 우수하다고 평가되고 있는 유전자 알고리즘을 적용하였다. 다목적 최적화의 경우 해의 우열을 판단하기 위한 적합도 함수는 실제 각 목적함수의 적합도 값(real fitness value)이 아닌 해의 상대적인 우열(dominance or non-dominance)에 따라 부여되는 등급(rank)에 의해서 해의 우열이 결정되며 여기서는 Fonseca and Fleming(1993)이 제안한 Ranking method를 적용하여 적합도를 결정하였다. 한편 도시 우수관망의 해석 및 우수저류조 설치에 따른 월류량 분석을 위하여 미 환경청(US Environmental Protection Agency; EPA)에서 제공하고 있는 EPA-SWMM 5.0 engine을 사용하였으며 최적화 알고리즘의 구성을 위하여 Visual C++와 SWMM DLL을 연동하여 사용하였다. 연구 대상유역은 인천 청라지구(3공구)를 대상으로 기법의 적용성을 검토하였으며 저류지 설치에 따른 비용함수는 EPA(2002)에서 제안한 저류지 체적대비 공사비용을 원화로 환산한 후 청라지구의 공시지가를 고려하여 결정하였다. 최적화 기법의 적용 결과 저류지 설치비용에 따라 최대로 월류량을 저감시킬 수 있는 우수저류조 최적 설치위치의 조합(Pareto-front)을 결정할 수 있었다.

  • PDF

Estimation of Agricultural Water Return Flow Using a Network Model Based on Paddy Irrigation Areas (논배수로 네트워크 모형을 통한 농업용수 회귀수량 산정 방안)

  • Inkyo Choo;Junhwa Lee;Adigun Ismail Adebayo;Younghun Jung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.407-407
    • /
    • 2023
  • 최근 환경부에서 발표한 국가물관리기본계획에서 수자원 총량 중 생활·공업·농업·유지용수의 이용량은 365억m3/년으로 약 29.4%로 발표되었다. 유지용수를 제외한 농업용수 이용량의 비중은 약 60.5%이며, 이 중 약 80%가 논에서 활용되고 있다. 이러한 농업용수 이용량 중 사용되지 않고 하천으로의 방류량이 존재하는데 이를 관개회귀수량이라하며, 농업용수의 약 35%가 하천으로 회귀된다 발표하나 지역에 따른 편차가 존재하기에 정확한 회귀수량을 산정하기엔 미흡한 실정이다. 따라서 본 연구에서는 네트워크 모형을 통한 용배수로 구축 이후 회귀수 정량화를 하고자 하며, 정량화를 위한 네트워크 모형은 EPA-SWMM(Storm Water Management Model) 모형을 활용하였다. 해당 모형은 미국 환경 보호국(U.S. Environmental Protection Agency, EPA)에서 개발한 네트워크 물리모형으로 다양한 환경적 요소에 따른 수문 영향을 확인 가능한 모형이다. 해당 모형의 다양한 네트워크 기능을 통해 논배수로 네트워크를 구축하여 회귀수 정량화를 진행하고자 한다. 논배수로 네트워크를 구축하기 이전 현장조사를 진행하였다. 현장조사를 통한 용수계통도를 작성하였으며, 모형의 입력자료로 필요한 네트워크 용배수로관 표고값을 측량하였다. 이후 현장조사 및 측량 자료를 활용하여 네트워크 물리모형의 입력자료 구축을 진행하였으며, 해당 자료 구축은 지리 정보 시스템 중 ArcGIS와의 연계를 통해 구축하였다. 모형의 수리학적 입력자료는 해당지역의 계측자료를 활용하였으며, 필지 사이의 내리흐름 및 펌프를 통한 용수 또한 네트워크 물리모형의 기능을 활용하여 구축하였다. 이후 계측자료와의 비교를 통한 매개변수 보정을 진행하였으며, 전체 논배수로에 대한 농업용수의 흐름 및 회귀수량을 분석하였다. 해당 연구를 통해 농업용수의 회귀수 산정 및 지역 편차에 따른 회귀수 정량화 등의 연구에 활용될 것으로 기대한다.

  • PDF

Uncertainty parameter correlation analysis (불확실성 매개변수 상관관계 분석)

  • Sim, Kyu Bum;Yeon, Jong Sang;Kim, Eung Seok;Chung, Gunhui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.19-19
    • /
    • 2015
  • 최근 기후변화로 인해 집중호우 및 게릴라성 폭우의 발생빈도가 증가하고 있다. 또한, 도시화 및 산업화로 인해 불투수지역이 증가하여 첨두강우의 도달시간은 짧아지고, 강우강도는 증가하는 현상을 보이고 있다. 이로 인해 도시유역에서는 우수관의 통수능 부족으로 인한 홍수가 빈번히 발생하고 있다. 본 연구에서는 EPA-SWMM User's manual에서 제공하는 예제 관망도를 이용하여 SWMM 모형 매개변수들 간의 상관관계 분석을 수행하였다. 사전 조사 및 분석을 통해 유역폭, 관조도계수, 불투수유역 조도계수, 투수유역 조도계수, 불투수면적 비율 등 총 5개의 매개변수를 분석 대상으로 선정하였다. 매개변수들 간의 상관관계를 분석한 결과 유역폭-관조도계수, 유역폭불투수유역조도계수, 불투수면저 비율-투수유역 조도계수가 양의 기울기를 가지는 1차 선형함수 형태를 보였다. 즉, 예로 유역폭이 증가하면 관조도계수 또한 증가하는 경향을 보였다. 반대로 유역폭-불투수면적비율, 불투수유역 조도계수-관조도계수의 경우 음의 기울기를 가지는 상관관계를 보였으며 특히, 유역폭-불투수면적비율의 경우 2차 회귀곡선을 가지는 감소경향을 보였다. 본 연구의 결과를 활용하여 향후 우수관 설계를 수행한다면 내수침수 저감에 실무적인 도움을 줄 수 있을 것으로 판단된다.

  • PDF

Determination of Optimum Design Capacity of Bio-retention for Improvement of Urban Water Cycle (도시 물 순환 개선을 위한 생태저류지의 최적설계용량 결정)

  • Lee, Okjeong;Choi, Jeonghyeon;Lee, Jeonghoon;Kim, Sangdan
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.745-753
    • /
    • 2017
  • In this study, a design strategy is proposed to restore the distorted urban water cycle to the natural water cycle through the LID facility. This is accomplished by determining the optimal LID facility design capacity through which flow duration curves remain the same before and after urban development. A part of the Noksan National Industrial Complex in Busan was selected as the study area and EPA SWMM was constructed to simulate long-term stormwater for various land use scenarios and LID facility design capacity. In the case that the study area was assumed to be a forest area or an agricultural area before urban development, it was found that it was necessary to allocate 7.3% or 5.5% of the impervious area to the area of the bio-retention in order for the flow duration curve to remain the same as before urban development. As a result of the sensitivity analysis of the bio-retention design capacity according to regional rainfall characteristics, the design capacity of 3.8~5.5% of impervious area is needed for the development of agriculture area. Therefore, it can be seen that the optimum capacity can be significantly different according to regional rainfall characteristics. On the other hand, as a result of analyzing the sensitivity of the design capacity according to the variation of the depth of each layer constituting the bio-retention and the size of contributing catchment area, the sensitivity of the optimal design capacity with respect to the design specifications of the bio-retention and the size of contributing catchment area was not significant.

Estimation of Stormwater Interception Rate for Bio-retention LID Facility (생태저류지 LID 시설의 강우유출수 처리비 산정)

  • Choi, Jeonghyeon;Lee, Okjeong;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.5
    • /
    • pp.563-571
    • /
    • 2017
  • Because of the rapid progress of urbanization in recent decades, the proportion of impervious areas in cities has increased. As a result, hydrological properties of urban streams have changed and non-point pollution sources have increased, that have had considerable influence on human life and ecosystems. To manage these situations, application of non-point pollution reduction facilities and LID facilities are expanding recently. In this study, it is investigated if rainfall interception rate used in design of non-point pollution reduction facilities can be applied to design of LID facilities. For this purpose, EPA SWMM is constructed for part of Noksan National Industrial Complex area wherein long-term observed storm water data can be obtained and storm water interception rates for various design capacities of a bio-retention LID facility reservoirs are estimated. While sensitivity of storm water interception rate according to design specifications of bio-retention facility is not large, sensitivity of storm water interception rate according to regional rainfall characteristics is relatively large. As a result of comparing present rainfall interception rate estimation method with the one proposed in this study, the present method is highly likely to overestimate performance of the bio-retention facility. Finally, a new storm water interception rate formula for bio-retention LID facility is proposed.