• Title/Summary/Keyword: EPA Method 9

Search Result 62, Processing Time 0.019 seconds

Comparison of isoButoxycarbonyl derivatives, tert.-butyldimethylsilyl derivatives, with US EPA Method in the sensitivity of Alkylphenols, Chlorophenols, and Bisphenol A Potential field-screening applications of GC/MS-SIM (기체 크로마토그래피/질량분석기를 이용한 field-screening 적용을 위한 알킬페놀류, 클로로페놀류 및 비스페놀 A의 isoBOC 유도체, TBDMS 유도체와 US EPA 방법의 비교)

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.196-213
    • /
    • 2002
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode followed by three work-up methods for comparison; EPA method, isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in water samples were extracted with dichloromethane. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 85.1~109.9% (EPA method) and 90.3~126.6% (isoBOC derivatization and TBDMS derivatization), respectively. The method detection limit of bisphenol A for SIM were 0.732 ${\mu}g/{\ell}$ (EPA method), 0.002 ${\mu}g/{\ell}$ (isoBOC derivatization) and 0.021 ${\mu}g/{\ell}$ (TBDMS derivatization). The SIM responses were linear with the correlation coefficient varying 0.9755~0.9981 (isoBOC derivatization), and 0.9908~0.9996 (TBDMS derivatization). When these methods were applied to treated wastewater sample from a polyethylene plant, the concentrations of 11 phenols were below the method detection limit.

Purification of Eicosapentaenoic Acid (EPA) and Docosahexaenoic Acid (DHA) Esters from Squid Oil by Silver Ion Chromatography (은 이온 크로마토그래피에 의한 오징어유로부터 eicosapentaenoic acid(EPA) 및 docosahexaenoic acid(DHA)의 분리농축)

  • Gyoung, Young-Soo;Yu, Ying-Lian;Yoon, Jung-Ro
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.361-364
    • /
    • 2004
  • EPA and DHA extracted from methyl esterified squid oil were purified by silver exchanged resin, silver nitrate-impregnated silica gel, silver exchanged zeolite, and silica gel column chromatography, among which column chromatography using mixture of silver exchanged resin and silica gel (10% by weight) showed the best result. By this simple purification method, EPA and DHA were concentrated from 12.5 to 27.9% (yield, 86,0%) and from 21.7 to 49.5% (yield, 87.3%), respectively. Silver exchanged resin had additional advantages of outstanding reusability and simple recovery of silver.

On-line SPE-HPLC Method using Alumina Filtering to Selectively Extract Phenolic Compounds from Environmental Water

  • Lee, Sung-Kwang
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.12
    • /
    • pp.3755-3759
    • /
    • 2010
  • A on-line SPE (solid phase extraction)-HPLC preconcentration method was developed for the determination of phenolic compounds at trace levels in environmental water sample. XAD-4 and Dowex 1-X8 were used as sorbent in the on-line SPE-HPLC method for the selective enrichment of nine phenolic compounds, which are included in the priority pollutants list of the US EPA. Also alumina prefiltering considerably reduced the amount of interfering peaks due to humic substances that could accumulated due to the preconcentration step and prevent quantification of polar phenolic compounds in environmental water samples. This method was used to determine the phenolic compounds in tap and river water and superiority to the US EPA 625 method in its enrichment factor, pretreatment time, recoveries, and detection limit. The limits of detection were in the range of $0.3-0.9\;{\mu}g/L$ in tap water sample.

Design and Implementation of Turbidity Measurement Module of Plume using a Digital Camera (디지털카메라를 이용한 굴뚝연기의 혼탁도 측정모듈의 설계 및 구현)

  • Ban, ChaeHoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.372-378
    • /
    • 2015
  • Smoke generated from business establishments and factories will not only cause air pollution but also have a significant impact on the human body. Generally, the most common method for measuring the turbidity of the plume generated from the stack is a method of observing by the transmissometer mounted in the chimney or Method 9 from the US EPA(Environmental Protection Agency) which is a visual method of determining plume turbid emitted from stationary sources. However, these methods need a lot of cost to build and maintain. In this paper, we build a plume turbidity measurement module programs using a digital camera. We design and implement a module which acquires the pictures of the plume using a digital camera and measures the turbidity of it using the DOM(Digital Optical Method). In addition, we demonstrate the excellence by comparing and analyzing implemented module and other methods.

Design and Implementation of Turbidity Measurement Module of Plume using Optical Sensing (광학센싱을 이용한 굴뚝연기의 혼탁도 측정모듈의 설계 및 구현)

  • Ban, ChaeHoon;Son, HyunGeun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.312-315
    • /
    • 2014
  • Smoke generated from business establishments and factories will not only cause air pollution but also have a significant impact on the human body. Generally, the most common method for measuring the turbidity of the plume generated from the stack is a method of observing by the transmissometer mounted in the chimney or Method 9 from the US EPA(Environmental Protection Agency) which is a visual method of determining plume turbid emitted from stationary sources. However, these methods need a lot of cost to build and maintain. In this paper, we build a plume turbidity measurement module programs using light sensing. We design and implement a module which acquires the pictures of the plume using a digital camera and measures the turbidity of it using the DOM(Digital Optical Method). In addition, we demonstrate the excellence by comparing and analyzing implemented module and other methods.

  • PDF

Application and Optimization of the IsoButoxycarbonyl Derivatization method to the Analysis of Trace Level Phenols in Environmental Samples (환경시료로부터 미량 페놀류의 분석을 위한 isoButoxycarbonyl 유도체화 분석방법 적용 및 최적화)

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.1
    • /
    • pp.37-51
    • /
    • 2002
  • Eleven phenols including two chlorophenols, eight alkylphenols and bisphenol A were derivatized with isobutylchloroformate to form their isobutoxycarbonyl derivatives. Standard phenol mixture was concentrated for the isobutoxycarbonyl (isoBOC) derivatization and analysed by gas chromatography/mass spectrometry (GC/MS). The recoveries of the derivatization method of alkylphenols, chlorophenols, and bisphenol A were calculated by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison; shaking and heating method. The linear detector responses were obtained in the concentration range of 5∼400 ng, with correlation coefficients varying from 0.9755∼0.9981. Recoveries of the alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison ; the US-EPA method and the isoBOC derivatization method, Eleven phenols in water samples were extracted with dichloromethane and then concentrated. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 85.1∼109.9% and 90.3∼126.6% for the US-EPA method and the isoBOC.

Chemical Composition and Leaching Characteristic of Coal Fly Ash (비산석탄회의 화학조성과 용출특성)

  • Rhee, Dong Seok;Kim, Jong Boo;Joo, Kwang Suk
    • Analytical Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.394-399
    • /
    • 1998
  • This study was carried out to characterize the chemical composition and leaching properties of heavy metals in coal fly ash, which was generated from Korean electrical power utilities in several million tons per year. Comparion with respect to the leachability of heavy metals between the Korea standard leaching test (KSLT) and the American Environment Protection Agency (EPA) method 1311 (TCLP: Toxicity Chracteristic Leaching Procedure) was performed. The concentration of Ag, As, Ba, Cd, Cr, Cu, Pb, Se, Hg in the leacheate was determined by ICP-MS. The analytical result showed a significant difference of the leachability according to the characteristics of the leaching solution except Se, suggesting the necessity of improvement in the leaching test method that is currently implemented in Korea.

  • PDF

A study of asbestos containing material characteristics and grade of risk assessment in schools, Korea (일부 학교 건축물의 석면함유 건축자재(ACM) 특성과 위해등급에 관한 연구)

  • Jung, Joon-sig;Park, Hyung-kyu;Song, Hyea-suk;Lee, Won-jeong;Kim, Yoon-shin;Jeon, Hyung-jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.5029-5037
    • /
    • 2015
  • The objective of this study is to investigate the distribution of asbestos containing materials and to evaluate risk assessment method in some schools, Korea. For the survey on ACM risk assessment, we used both EPA AHERA rule and ASTM rule. We investigated 100 schools between January and December in 2010. Detection rate of the ACM according to construction year showed that before 1980's, 1990's, 2000's, after 2000's buildings were 100%, 94.1%, 100% and 62.5%, respectively. Compared with school types, detection rate of the ACM in Kindergarten, Elementary, Middle, High, Special Education schools were 100%, 97.1%, 92.9%, 100%, 80%, respectively. Ceiling textiles contained chrysolite/mixed amosite(2~8 %) and wall cement flat boards contained chrysolite(6~11 %). Also, gasket contained chrysolite(16~17 %), slate roof contained chrysolite(10~13 %). In this study, risk assessment EPA AHERA rule of ACM showed that all materials were "Pool" grade. And, ASTM rule risk assessment showed that all materials were "Q&M program" grade.

Nutritional Components and Safety of Purified Pufferfish (Lagocephalus gloveri) Liver Oil

  • Kim Dong-Soo
    • Fisheries and Aquatic Sciences
    • /
    • v.6 no.4
    • /
    • pp.172-179
    • /
    • 2003
  • The safety of pufferfish (Lagocephalus gloveri) liver oil and the contents of some nutritional components were examined to obtain important information on their use as high valued functional foods. Pufferfish liver oil was extracted by the hot-water method using $1\%$ NaOH solution to remove toxic compounds, and then purified using a general purifying method of fish oil. Any extraordinary clinical symptoms were not observed from all groups administrated with pufferfish liver oil throughout the test period. None of the rats died when administrated the highest concentration of 10 mL/kg of the pufferfish liver oil. Vitamin A content was 114.2 ppm, as a retinal equivalent in the oil extracted using hot-water, but the content was higher (169.3 ppm) in oil extracted using n-hexane. Vitamin D and E were not detected in ppm in oil extracted using hot-water. Vitamin D in the pufferfish liver oil extracted using n-hexane was also undetected, but vitamin E was at 32.5 ppm. Among the 18 minerals detected, the sodium content was the highest at 253.5 ppm, followed by 13.9 ppm ofpotassium, 1.5 ppm of calcium, 0.2 ppm of magnesium, and other trace minerals. The contents of EPA and DHA were $0.8\%\;and\;14.8\%$, respectively, in the pufferfish liver oil extracted using hot-water. Considering these results, there is potential that pufferfish liver oil could be used as a functional food.

Calibration of Parameters in QUAL2E using the Least-squares Method (최소지승법에 의한 QUAL2E 모델 반응계수 보정)

  • Kim, Kyung-Sub;Yoon, Dong-Gu;Lee, Gi-Young
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.9
    • /
    • pp.719-727
    • /
    • 2004
  • Water quality models can be applied to manage the regional water quality problems and to estimate the target and allowable pollution load in watershed effectively. The optimization of state variables in the given water quality model Is necessary to build up more effective model. The least-squares method is applied to fit field observations in QUAL2E developed by U.S. EPA, which is most widely used one in the world to simulate the stream water quality, and the optimization model with constraints is constructed to estimate the parameters. The objective function of the optimization model is solved by Solver in Microsoft Excel and Monte Carlo simulation is conducted to know the influence of parameter in conventional pollutants. It is found that this technique is easily implemented and rapidly convergent computational procedure to calibrate the parameters after appling this approach in Anyang stream located in Kyonggi province mainly.