• 제목/요약/키워드: EMTDC simulation

검색결과 438건 처리시간 0.031초

Harmonic Analysis Model based on PSCAD/EMTDC

  • Lee, Han-Min;Lee, Chang-Mu;Jang, Gil-Soo;Kwon, Sae-Hyuk
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권3호
    • /
    • pp.115-121
    • /
    • 2004
  • This paper presents the model for an AC electric railway system using the PSCAD/EMTDC program. It is composed of a scott-transformer, an auto-transformer, catenary and electric trains, etc. After obtaining the models of the fundamental elements describing the AC electric railway system and its behavior, we have analyzed and tested an actual AC electric railway system focused on the amplification of harmonic current to verify the proposed model. The simulation results from the proposed approach and the measurement data from the test are described.

PSCAD/EMTDC를 이용한 DVR의 전압보상 효과분석 (Analysis on Voltage Compensating Effect of DVR using PSCAD/EMTDC)

  • 박상호;최영도;박영신
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.165-171
    • /
    • 2010
  • There are many researches on Power Quality Device to protect the critical load and power system as the nonlinear load and precision load are adopted into the power system recently. To analyze the voltage compensation of voltage sag and voltage swell by DVR, which is connected to the important load in series, this paper shows PSCAD/EMTDC simulation and its verification by comparing with the actual DVR output of 2MVA. DVR control scheme in this paper is applicable to compensate single-phase, 2-phases or 3-phases voltage sag as well as DVR for distribution system.

EMTDC를 이용한 765/345kV 병가선로의 불평형 계통 해석 (Unbalanced Power System Analysis in 765/345kV Parallel Transmission Line by Using EMTDC)

  • 김종율;윤재영;최흥관;이운희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.199-201
    • /
    • 2003
  • Because of Korean power system characteristics and increasing power demand, the need of 765kV transmission line is growing gradually. Now a days, KEPCO's 765kV transmission line has been tested and stands for commercial operation. During the first stage, 765kV transmission line will be operated with two voltage grades of 765kV and 345kV, which results the unbalance of power system. So unbalanced current such as zero sequence current flows in the transmission line. In this paper, we describes the simulation study of 765/345kV parallel transmission line by using EMTDC program.

  • PDF

EMTDC를 이용한 DSTATCON 설치 효과 분석 (Analysis of System Performance on DSTATCON Installation using EMTDC)

  • 유일도;최영준;홍순옥;이학성;전영수;이기선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.943-945
    • /
    • 1998
  • This paper presents a method of modeling of DSTATCON (Distribution-line Static Condenser) for installation in a specific plant and analyze the effectiveness of the DSTATCON from the viewpoints of voltage regulation and harmonic mitigation in a distribution line. For the reliable modeling, detailed information on distribution system and loads is performed by field measurements. The DSTATCON has been modeled according to the control algorithm of real controller. The effectiveness of the DSTATCON installation is verified by simulation using EMTDC.

  • PDF

PSCAD/EMTDC Modeling/Analysis of VSC-HVDC Transmission for Cross Border Power System Interconnection

  • Kim, Jong-Yul;Yoon, Jae-Young;Kim, Ho-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.35-42
    • /
    • 2009
  • When two adjacent AC systems operate at different frequency such as 50Hz and 60Hz, as in the case of ROK and Russia, the only way to practically obtain the advantages of power system interconnection is to use HVDC connection. In this paper, application of the VSC-HVDC transmission for power system interconnection between Russia and ROK is evaluated through the PSCAD/EMTDC modeling and analysis. The simulation results show the feasibility of proposed system for cross border power system interconnection.

EMTDC를 이용한 경부고속철도 고조파 전류 확대율 해석 (Analysis of the amplification of Harmonic Current Using EMTDC in Kyongbu High-Speed Railway)

  • 이한민;이장무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1379-1381
    • /
    • 2004
  • This paper presents the AC electric railway system modeling using PSCAD/EMTDC program. This system model is composed of the scott-transformer the auto-transformer. the running rails. the protection wires, the feeders. the catenary and contact wires, etc. After obtaining the models of the fundamental elements describing the AC electric railway system and its behavior, we have analyzed and tested real traction power feeding system focused on the amplification of harmonic current to verify the proposed model. The simulation results from the proposed approach and the measurement data from the test are described in the paper.

  • PDF

EMTDC를 이용한 시송전계통의 고조파공진 분석 (Analysis of the Harmonic Resonance in Primary Restorative Transmission Systems Using EMTDC)

  • 이경섭;박성민;송인준;이남호;배주천;황봉환;이흥재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권4호
    • /
    • pp.172-176
    • /
    • 2005
  • Power system restoration following a massive or complete blackout starts with energizing of primary restorative transmission lines. During this primary restoration, inexpected overvoltage may happen due to nonlinear interaction between the unloaded transformer and the transmission system. This is known as the harmonic resonance phenomenon that may cause burning out of transformer or other devices. By now the harmonic resonance is reported in the extra high voltage system. This paper reports the detection of the resonance in Korean power system. Basic analysis and simulation of the harmonic overvoltage is presented using EMTDC.

Analysis of Voltage Regulation by DSTATCOM - Using the EMTDC Program

  • Jeon Young-Soo;Kwak No-Hong;Choo Jin-Boo
    • Journal of Power Electronics
    • /
    • 제5권4호
    • /
    • pp.329-334
    • /
    • 2005
  • The DSTATCOM(Distribution Static Synchronous Compensator) is one of the Custom Power Devices that can regulate voltage. The DSTATCOM operates as a shunt connected static var compensator whose capacitive or inductive output current can be controlled independent of the system voltage. The magnitude of the compensated voltage is limited by characteristics of the system and the load. Compensation capability of the DSTATCOM which can inject 1 MVAR reactive power was simulated by EMTDC under several conditions. This paper analyzes the effect of the DSTATCOM's compensation considering the length and kind of distribution line, the power factor and magnitude of the load, and the duration and magnitude of the voltage variation.

컴퓨터 시뮬레이션과 실규모 하드웨어시뮬레이터를 이용한 계통연계 풍력발전의 응동특성 분석 (Dynamic Interaction Analysis of Interconnected Wind Power Generator using Computer Simulation and Real-Size Hardware Simulator)

  • 윤동진;한병문;최영도;전영수;정병창;정용호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1047_1048
    • /
    • 2009
  • This paper describes comparative analysis results about the dynamic interaction of interconnected wind power system using the actual-size hardware simulator and the simulation model with PSCAD/EMTDC. The hardware simulator, which is composed of 2.0MVA induction motor with drive system and 1.5MW doubly-fed induction generator, was built and tested in Go-Chang Test Site of KEPCO for analyzing the dynamic interaction with the interconnected distribution system. The operation of hardware simulator was verified through comparative analysis between experimental results and simulation results obtained by simulation model with PSCAD/EMTDC. The developed hardware simulator and simulation model could be effectively used for analyzing the dynamic interaction, which has various phenomena depending on the wind variation and the network state of interconnected power system.

  • PDF

컴퓨터시뮬레이션과 실용량 하드웨어시뮬레이터를 이용한 계통연계 풍력발전의 성능비교분석 (Performance Comparison Analysis for Interconnected Wind Power Generator using Computer Simulation and Real-Size Hardware Simulator)

  • 윤동진;오승진;한병문;정병창;정용호;최영도;전영수
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.263-269
    • /
    • 2009
  • This paper describes comparative analysis results about the dynamic interaction of interconnected wind power system using the actual-size hardware simulator and the simulation model with PSCAD/EMTDC. The hardware simulator, which is composed of 2.0MVA induction motor with drive system and 1.5MW doubly-fed induction generator, was built and tested in Go-Chang Test Site of KEPCO for analyzing the dynamic interaction with the interconnected distribution system. The operation of hardware simulator was verified through comparative analysis between experimental results and simulation results obtained by simulation model with PSCAD/EMTDC. The developed hardware simulator and simulation model could be effectively used for analyzing the dynamic interaction, which has various phenomena depending on the wind variation and the network state of interconnected power system.