• 제목/요약/키워드: EMTDC/PSCAD

검색결과 690건 처리시간 0.037초

전원 전압 불평형시 계통연계형 인버터의 유효전력 리플 억제를 위한 듀얼 전류제어기 구현과 출력 전력의 실시간 제한 알고리즘 (Implementation of Dual Current Controller and Realtime Power Limiting Algorithm in Grid-connected Inverter during Unbalanced Voltage Conditions)

  • 송승호;김정재
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권1호
    • /
    • pp.54-60
    • /
    • 2006
  • A power limiting algorithm is proposed for stable operation of grid-connected inverter in case of grid voltage unbalance considering the operation limit of inverter. During the voltage unbalance the control performance of Inverter. is degraded and the output power contains 120Hz ripple due to the negative sequence of voltage. In this paper, conventional dual sequence current controller is implemented to solve these problems using separated control of positive and negative sequence. Especially the maximum power limit which guarantees the maximum rated current of the inverter is automatically calculated as the instant grid voltage changes. As soon as the voltage recovers the proposed algorithm can return to the normal power control mode accomplishing low voltage ride through. Proposed algorithm is verifed using PSCAD/EMTDC simulations and tested experimentally at 4.4kW wind turbine simulator set-up.

Dynamic Voltage Restorer Prototype 설계에 관한 연구 (A Study on the Design of the Dynamic Voltage Restorer Prototype)

  • 김지원;전영환;전진홍;오태규;박동욱
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권3호
    • /
    • pp.140-145
    • /
    • 2001
  • The instantaneous voltage drop is occurred when the fault is happened on the nearby feeders. The instantaneous voltage drop is continued during relatively short period. But, the effect of it can be very severe to some sensitive devices. That is, it can be the reason of restart or malfunction of some devices. And these phenomenons can cause the enormous economical damage and shorten the lifetime of the devices. In this paper, the device which can compensate the instantaneous voltage drop, is studied. Through the computer simulation using PSCAD/EMTDC, the validity of the control algorithm using peak detection method is verified. And the Dynamic Voltage Restorer(DVR) prototype is designed and constructed. Through the experiment, the function and performance of the DVR prototype is verified.

  • PDF

펄스다중화 보조회로를 이용한 36-펄스 Back-to-Back 전압원 컨버터의 직류송전 적용연구 (Study on 36-pulse Back-to-Back Voltage Source Converter with Pulse-Interleaving Auxiliary Circuit for HVDC Application)

  • 백승택;최준영;한병문
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권3호
    • /
    • pp.102-108
    • /
    • 2006
  • This paper proposes a 36-pulse back-to-back voltage source converter using four sets of 12-pulse bridges with pulse-Interleaving auxiliary circuit. The proposed back-to-back voltage source converter has an independent control capability of active power and reactive power at the at connection point. The principle of increasing the number of pulses was analyzed using theoretical approach. The operational feasibility of proposed system was verified through computer simulations with PSCAD/EMTDC software. The proposed back-to-back converter can be widely used for the HVDC and FACTS devices.

직류 마이크로그리드의 평균 전압 변동을 최소화하기 위한 드룹 제어 전원의 위치 선정 기법 (A Positioning Method of Droop Controlled Sources for Minimum Average Voltage Variation in a DC Microgrid)

  • 고병선;이기영;김래영;김태훈;김주용
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.116-117
    • /
    • 2017
  • 본 논문에서는 전압 민감도를 통해 직류 마이크로그리드의 전압 변동을 최소화하기 위한 드룹 제어 전원의 위치 선정 기법을 제시한다. 전압 민감도를 도출하기 위해 전력 흐름 분석을 수행하였으며, 드룹 제어의 특성을 반영하기 위해 드룹 버스를 도입하였다. 그러나 드룹 버스를 적용함으로써 전력망의 전압 민감도는 드룹 제어 전원의 위치에 의존하게 된다. 따라서 드룹 제어 전원의 위치에 따른 전압 민감도를 분석하고 이를 비교하여 DC MG의 평균 전압 변동이 최소화되는 위치를 결정하였다. 제안한 드룹 제어 전원의 위치 선정 기법의 결과를 PSCAD/EMTDC 시뮬레이션을 통해 검증하였다.

  • PDF

직병렬 Active Filter의 시뮬레이션 해석에 관한 연구 (A Study On the Simulation Analysis of Series and Shunt Active Filter)

  • 김아롱;방종현;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2435-2437
    • /
    • 2005
  • 전력시스템의 규모는 날로 증가하고 부하조건 역시 매우 다양해져 많은 수의 전력변환 장치가 사용되고 있으며, 변환장치에 사용되는 비선형성 전력반도체 소자의 사용은 고조파의 발생을 가져온다. 또한 대규모 부하의 초기기동에 의한 전압강하(Voltage Sag)가 일어나게 되어 전력시스템에 좋지 않은 영향을 주게 되며 고조파와 함께 전력의 품질저하 또는 기계적 오작동 등을 가져다 준다. 본 논문에서는 이런 전압, 전류의 전력품질 저하를 보상하기 위해 Active Filter를 적용한 예를 PSCAD/EMTDC 시뮬레이션 프로그램을 이용하여 시스템 해석을 실시하였다. 본 연구를 통해 직 병렬 동시적용 Active Filter의 유용성을 확인할 수 있었다.

  • PDF

전지전력저장시스템의 배전시스템 연계시 고조파 분석 (Harmonic analysis of Battery Energy Storage System on distribution system)

  • 김영성;류영돈;임성정;김재철;김응상;고요
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.856-858
    • /
    • 1996
  • This paper describes a simulation model to analyze the interconnection operation of battery energy storage system(BESS) and utility system. The computer model used to these analysis composed by using PSCAD/EMTDC. The impacts experienced at load side are studied when occur faults in utility system, and also harmonics analysis are implemented. Results of these study are available to design the harmonic filter.

  • PDF

외부 배전선 사고에 대한 분산전원 보호 알고리즘의 동작 수준 평가 (Assessment of the Protection Algorithm Applied in Distributed Generations for Faults Occurred in the Interconnected Distribution Networks)

  • 장성일;김세근;박용업;김광호;최정환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.337-340
    • /
    • 2003
  • This paper describes the operational characteristics of protection algorithm applied in distributed generations(DG) for faults occurred in the interconnected distribution networks. The DG can be Influenced by abnormal grid conditions such as disturbances occurring in the neighboring distribution feeders as well as the interconnected power line. Particularly, in case of the fault happening in the neighboring distribution feeders emanated from the substation to which DG is connected, the protective devices in the DG might mis-operate. The mis-operation of protective devices can be varied by the fault conditions. The simulation results for Hoenggye substation model composed of five feeders using PSCAD/EMTDC showed that the number of mis-operation of protective devices applied in DG is about 0.66 times per one year.

  • PDF

고효율 DC-DC 컨버터와 인버터에 의한 연료전지발전용 전력변환기 연구 (Study on Power Converter for Fuel Cell Power Generation with Highly Efficient DC-DC Converter)

  • 주영아;한병문;오은태;이준영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.209-211
    • /
    • 2009
  • 본 논문에서는 고효율 DC-DC 컨버터와 인버터에 의한 연료전지발전용 전력변환기를 제안한다. 제안하는 전력변환기는 Boost Converter와 LLC공진 컨버터의 2 stage 조합으로 구성되어 있다. 제안하는 전력변환기의 동작을 분석하기 위해 PSCAD/EMTDC를 이용하여 연료전지의 출력 동특성을 나타내는 모델과 제안하는 전력변환기의 모델을 개발하였다. 시뮬레이션모델의 검증을 위해 하드웨어장치를 구성하여 실험을 실시하였다. 제안하는 전력변환기는 정격출력에서 저전압특성을 갖는 연료전지를 전력계통에 고효율로 연계하는데 유용할 것으로 보인다.

  • PDF

HVDC 케이블 고장점 표정 알고리즘 (Fault Location Algorithm for HVDC Cables)

  • 권영진;이동규;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.73-74
    • /
    • 2007
  • For a safe operation of HVDC systems, the fault location and clearance of faults in the HVDC lines are important. Past methods for fault location on HVDC cable depend on existence of assistance cables and fault resistance, broken cable and environment of fault location. For complement these problems, in this paper, fault location method using traveling wave and cross correlation function is proposed for HVDC cables. Voltage controlled source and current controlled source HVDC were modeled by EMTDC/PSCAD. The proposed algorithm were verified varying with fault distance, fault resistance.

  • PDF

H-브리지 인버터와 수퍼커패시터로 구성된 단상 DVR(Dynamic Voltage Restorer)의 개발 (Development of Single-Phase DVR(Dynamic Voltage Restorer) Composed of H-Bridge Inverter and SuperCapacitor)

  • 이동근;이두영;양승철;배병열;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.160-161
    • /
    • 2007
  • This paper describes the development of a single-phase DVR(Dynamic voltage Restorer), which is composed of H-bridge inverter and super-capacitors. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with 3kVA prototype. The developed system can compensates the input voltage sag and interruption within 2ms, in which the maximum allowable duration of voltage interruption is 1.5 seconds. It can be effectively used to compensate the voltage interruption in the sensitive load, such as computer, communication equipment, automation equipment, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components and to be highly reliable in operation.

  • PDF