Design Guideline of Waveguide-Below-Cutoff Array for Electromagnetic Pulse Shielding (EMP 차폐 도파관의 형상 결정 가이드라인 작성)

  • Pang, Seung-Ki;Kim, Jae-Hun;Yook, Jong-Gwan;Kim, Yuna;Kim, Sangin
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.86-91
    • /
    • 2016
  • Convenient design guideline for Waveguide-below-cutoff (WBC) array is proposed to obtain the minimum waveguide length for electromagnetic pulse (EMP) shielding. The analysis includes circular, rectangular, and hexagonal WBC, determine the total length of the waveguide. When the unit side of rectangular WBC and the diagonal line of hexagonal WBC are given as 30 mm, the length of hexagonal WBC is 5 mm shorter than rectangular case with shielding effectiveness (SE) 80 dB. The length difference is deepened with SE of 100 dB, which shows approximately 30 mm shorter length for hexagonal case than others. In addition, hexagonal WBC requires much shorter length than circular WBC. In conclusion, hexagonal case is the most effective with respect to flow velocity and pressure loss for equivalent SE.

Design of a Planar Log-Spiral Antenna for Testing Plane-Wave Shielding Effectiveness (평면파 차폐효과 시험용 평판형 로그 스파이럴 안테나 설계)

  • Chung, Yeon-Choon
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.762-767
    • /
    • 2019
  • The plane-wave shielding effectiveness is typically measured for horizontal and vertical polarizations using a linearly polarized antenna. However, this typical measurement method results in big evaluation fees due to very long measurement time as well as huge idle space for maintenance, these problems is more severe especially in large shielded enclosures such as EMP protection facilities to be built in indoor buildings and underground. This paper describes the design and fabrication process and results of a planar log-spiral antenna applicable to the evaluation of the electromagnetic shielding effectiveness of a large EMP protection facility. Since the proposed antenna has a circular polarization, there is no need to separately measure the horizontal and vertical polarizations. Therefore, the measurement time can be shortened by more than 1/2, and further, its small volume with a planar structure can reduce greatly idle space required for the maintenance.

Electric Field Strength and Shielding Effectiveness Comparison According to the Size of Shielding Facility (방호 시설 크기에 따른 전계강도 및 차폐 효과 비교)

  • Kang, Ho-Jae;Huh, Chang-Su;Bang, Jeong-Ju;Choi, Jin-Su;Park, Woo-Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.4
    • /
    • pp.221-225
    • /
    • 2014
  • In modern times, threat of high power electromagnetic wave is increasing. When the electrical grid and communication network are attacked by these high power electromagnetic wave, the whole infrastructure is paralyzed. To protect the infrastructure from these high power electromagnetic wave threat, the shielding facility that can block high power electromagnetic wave is constructed. Also shielding effectiveness evaluation about the constructed facility is important. But, because of space efficiency and saving of construction cost to construct the actual shielding facility, the shielding room wall is generally adjacent to exterior concrete structures. As space between shielding facility wall and concrete structures is very small, arranging the transmitting antenna exterior shielding facility is realistically difficult. Therefore, in this research, The shielding effectiveness measurement plan in the state of exterior narrow space of HEMP shielding facility is presented. And to apply this plan, The influence of shielding effectiveness according to the size of the shielding facility is analyzed.

A Study on Validation of the Shielding Effectiveness Measurement Method of the Concrete Containing Electric Arc Furnace Oxidizing Slag (전기로산화슬래그를 활용한 콘크리트의 차폐효과 측정 방법의 유효성 검증 연구)

  • Jang, Hong-Je;Lee, Han-Hee;Choi, Hyo-Sik;Song, Tae-Seung;Cho, Won-Seo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.478-482
    • /
    • 2021
  • In this paper, methods for manufacturing shielding concrete by recycling steelmaking slag discarded as industrial waste and measuring the shielding effectiveness of the shielding concrete were studied. By comparing the result of shielding effectiveness measurement of this concrete block with shielding effectiveness measurement of the structure constructed with this concrete, the measurement system for measuring shielding effectiveness of the concrete block was verified. The size of the concrete stru ctu re is 2.9 × 2.9 × 3.4m and the concrete block is 0.3 × 0.3 × 0.2m. The frequ ency band u sed for mesu rement is 600MHz - 2GHz, the types of concrete u sed to measu re the shielding effectiveness are general concrete and concrete containing electric arc furnace oxidizing slag. In the case of the concrete structure, reinforcing rebars are installed at intervals of 15cm for stru ctu ral safety, as the frequ ency increase, the electromagnetic wave properties of rebars gradu ally decreased, there was a slight difference in the measurement results. In conclusion, the measurement result of shielding effectiveness of the concrete block is similar to the result of the concrete structure. It is thought that it can be sufficiently utilized for electromagnetic wave engineering design, and the concrete shielding effectiveness measurement system using standard specimens was verified.

A Study on the Performance Measurement System for the Reinforced Concrete Structure Electromagnetic Shielding Wall (철근 콘크리트 구조 전자파 차폐 벽체에 대한 성능측정 시스템 연구)

  • Kim, Bo-Hyun;Cho, Kyeong-Yong;Park, In-Wook;Oh, Jae-Hyun;Lee, Sang-Hoon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.492-498
    • /
    • 2021
  • In this paper, the electromagnetic wave transmittance of the reinforced concrete structure wall was analyzed using the performance measurement system of electromagnetic wave shielding. Recently, electromagnetic wave shielding technologies on the reinforced concrete wall conditions have been studied, and the shielding effectiveness have been tested on unit cell size. However, the unit cell size tests have problems on that the measurement range for shielding performance is insufficient and it is difficult to reflect the real conditions of the concrete wall. Therefore, we constructed a shielding performance measurement system using a large sample of 2.2m × 2.2m like a real wall. To verify the measurement system, general reinforced concrete test samples were selected, and real shielding performance measurements and numerical analysis were proceeded. Test and numerical analysis results showed similar tendencies in the evaluation frequency range of 75MHz to 2GHz. Thus we validated the effectiveness of this shielding performance measurement system.

Electromagnetic Pulse Coupling into Naval Warship and Protective Measures (해군 함정에서의 EMP 영향 및 대책)

  • Yang, Jin-Ho;Nam, Sang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.4
    • /
    • pp.426-433
    • /
    • 2014
  • The high-altitude electromagnetic pulse(HEMP) generated by a high-altitude nuclear explosion. This paper presents the comparison of electric field penetration in Bell laboratories and IEC 61000-2-9 standard when HEMP source penetrates through Naval Warship conducted coupling path and radiated coupling path. Also we analyze the effects of two kinds of coupling and propose Protective measures. Simulation results confirm IEC 61000-2-9 standard is more strict than the Bell Laboratories standard except for a lower frequency band, so we proposed IEC 61000-2-9 standard as a Naval HEMP standard. Finally, we offer the protective measures such as the shielding coating, Honeycomb ventilation, TVS in order to meet the military criteria.

Analysis of EMP Shielding Effectiveness and Flow of Fluid with Multi-Layered Waveguide-Below-Cutoff Array (다층 구조를 이용한 도파관 배열의 EMP 차폐성능과 유동 분석)

  • Kim, Sangin;Kim, Yuna;Pang, Seung-Ki;Kim, Suk-Bong;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.8
    • /
    • pp.735-741
    • /
    • 2016
  • Increasing the total length of waveguide-below-cutoff array(WBCA) as it is used to the duct in order to enhance shielding effectiveness, the design could cause higher cost, higher levels of difficulties in construction and the interruption a flow velocity. The multi-layered WBCA can compensate for this problem, which can be designed by crossing each waveguide layer. By conducting simulations from 2-layer to 8-layer structure, it can be observed that the shielding effectiveness increases from 52 dB to 75 dB. Comparing with the original WBCA in a shape of mono layer rectangular, our proposed waveguide becomes similar with the original value as the number of crossing layer increases. In addition, the analysis with the flow of fluid in the duct installed multi-layered WBCA are required. We demonstrate this analysis by doing the flow of fluid simulation, and concluded that the multi-layered WBCA has loss of flow of fluid less than unit rectangular WBCA.

A Development of the Optimized Shielding Room Design Simulator for HEMP Protection (HEMP 방호용 차폐실 최적설계를 위한 시뮬레이터 개발)

  • Min, Gyung-Chan;Kim, Dong-Il
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.121-126
    • /
    • 2010
  • Regarding HEMP has been studied as few thousand of paper by major nuclear bomb holding countries with USA for the self protection against nuclear bomb attract. Major HEMP protection facilities are consist of the shielding, filtering, grounding and high voltage protection circuits. Shielding room construction required a highest cost among the key protective facilities. Most of a theoretical formulas listed on the paper and related books has a little correlations in the certain frequency band between the theoretical formulas and field measuring results. For the reasons we proposed the advanced new theoretical formulas and developed the computer simulation S/W as enough as apply to the cost effective shielding room design for HEMP considering the various structural constants.

Electromagnetic Pulse Shielding Effectiveness and Construction Availability of Cast-In-Place Structures Using Corrugated Metal-Plates

  • Kim, Suk Bong;Yoon, Sangho;Min, Gyung Chan;Ahn, Sungjin;Park, Young Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.1
    • /
    • pp.84-89
    • /
    • 2013
  • This study aims to examine the effectiveness of electromagnetic pulse shielding in cast-in-place protective shelters using corrugated metal-plates, and then reviews their usability for the Republic of Korea Army. The Korea Corps of Engineering has evaluated corrugated metal-plates as a construction material for cast-in-place structures, which have to defend against mechanical impacts as well as electromagnetic pulses. Corrugated metal-plate is known as a superb mechanical protective material, so much so that it has been employed in ammunition magazines and artillery platforms in the armed forces. Moreover, as a metal, such as steel and copper, it is universally recognized as one of the most effective electromagnetic pulse shielding materials. In addition to effectively shielding from electromagnetic pulses and protecting against mechanical impacts, corrugated metal-plates should prove to be an appropriate construction material for the cast-in-place protective shelter in terms of construction availability and economic feasibility. The shielding effectiveness of the suggested structures is examined based on MIL-STD 188-125-1. A few frequency bands need an increase of 15~30dB in shielding effectiveness because of unbidden apertures caused by flaws associated with welding, assembling, and material deformation. However, allowing for the approximately 40dB of shielding provided by soil; the examined structure, which is buried underground, can offset its shortcomings sufficiently.

Analysis of Low-Frequency Magnetic SE of a Metal Plate: Diffusion and Slot Effects (도체 판의 자기장 차폐효과 분석: 확산과 슬롯 효과)

  • Park, Hyun Ho;Kwon, Jong Hwa
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.4
    • /
    • pp.324-327
    • /
    • 2019
  • This study analyzes the low-frequency magnetic shielding effectiveness (SE) of a metal plate, in terms of diffusion and slot effects, by conducting a numerical simulation and implementing an analytical solution. When the metal has a low conductivity, the SE is dominated by the diffusion effect. However, when the conductivity and frequency both increase, the slot has a major influence on the SE. These results can be used as guidelines in the shielding design and SE requirements of electromagnetic pulse protection facilities.