• 제목/요약/키워드: EMI characteristic

검색결과 51건 처리시간 0.027초

New Energy Recovery Concept for AC PDP Sustaining Driver Using Current Injection Method (CIM)

  • Lee, Jun-Young;Kim, Jin-Sung;So, Myeong-Seop;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.189-198
    • /
    • 2002
  • New concept of energy recovery for plasma display panel (PDP) Is proposed. Different from conventional LC resonant sustaining drivers, the current built up before inverting the polarity of the panel electrodes is utilized to change the panel Polarity together with energy Previously charged in Panel capacitance. This operation Provides zero -voltage-switching of switches and reduction of EMI by rejecting the surge current when the sustain switches are turned on. The build-up current helps to reduce transition time of panel polarity and may produce more stable light waveforms. This method shows a desirable characteristic that the circuit loss is similar to that of series resonant type energy recovery circuit which is very effective method.

Considerations on the use of a Boost PFC Regulator Used in Household Air-conditioning Systems (over 3kW)

  • Jang Ki-Young;Suh Bum-Seok;Kim Tae-Hoon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.589-592
    • /
    • 2002
  • The CCM (Continuous Conduction Mode) boost topology is generally used in the PFC (Power Factor Correction) regulator of household air-conditioning systems. There are three kinds of power devices-bridge rectifier diodes, FRDs (Fast Recovery Diodes), and IGBTs (or MOSFETs) - used In a boost PFC regulator. Selecting the appropriate device is very cumbersome work, specially, in the case of FRDs and IGBTs, because there are several considerations as described below: 1) High frequency leakage current regulation (conducted and radiated EMI regulation) 2) Power losses and thermal design 3) Device cost. It should be noted that there are trade-offs between the power loss characteristic of 2) and the other characteristics of 1) and 3). This paper presents a detailed evaluation by using several types of power devices, which can be unintentionally used, to show that optimal selection can be achieved. Based on the given thermal resistances, thermal analysis and design procedures are also described from a practical viewpoint.

  • PDF

광전계 센서를 이용한 구형 Loop Antenna의 근접전계 특성 (Characteristic for the Near Field of Rectangle Loop Antenna using Optical Electric-Field Sensor)

  • 이주현;도쿠다마사미추;하덕호
    • 한국전자파학회논문지
    • /
    • 제14권3호
    • /
    • pp.217-225
    • /
    • 2003
  • 본 논문에서는 전파암실(8.5 m x 7 m x 7 m)에서 광전계센서를 이용한 Loop Antenna의 근접전계 분포특성을 파악하기 위해 시간 및 주파수 영역에 대하여 측정한 후 시뮬레이션 결과와 비교 분석하였다. 시뮬레이션은 MoM와 FDTD을 이용하여 각각 주파수 및 시간영역에 대하여 시뮬레이션 하였다. 그 결과 측정 과 시뮬레이션이 상당히 일치하였으며, 측정에 이용한 광전계 센서의 유효성을 확인하였다. 또한, 주파수 영역에 있어서 Loop Antenna의 수직 엘리멘트 근접에 광전계 센서를 각각 수직 과 수평편파로 한 경우 약 15 ㏈ 정도의 차이를 보였고 Loop Antenna의 수평 엘리멘트 보다 높은 곳에서는 신호레 벨의 별다른 차이가 없었다. 그리고, 시간영역에 있어서는 Loop Antenna의 수평 엘리멘트 보다 높은 곳에서 광전계센서를 수직편파로 한 경우의 수신펄스 모양은 부(-)의 방향으로 됨을 알 수 있었다.

IGBT 인버터를 사용한 저속 표준형 엘리베이터의 개발 (The development of a low speed standard type elevator with an IGBT inverter)

  • 김병하;박상영;황수철;서명석;백종현;한권상;정유철;김지헌;이정구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.606-608
    • /
    • 1994
  • This paper presents a low speed (1m/sec) elevator controller with a IGBT inverter (9.5KW). The major engineering problems of this development are noise suppression, thermal-dissipation and reliability improvement. The characteristic marks of this elevator are a single board controller, 40% reduced component, 40% reduced cubic content, EMI filter, vector controlled IGBT inverter.

  • PDF

저압 인입선에서의 고속 전력선통신 특성 분석 (Performance Characteristics of Broadband PLC at Out-door Field Test-bed)

  • 박병석;유동희;현덕화;최영림
    • 전력전자학회논문지
    • /
    • 제10권3호
    • /
    • pp.264-273
    • /
    • 2005
  • 별도의 통신선 없이도 고속 통신채널을 구현할 수 있는 고속 전력선 통신 분야는 활용측면에서 유용성이 매우 높아 기술개발과 발전이 급격히 이루어지고 있다. 그러나 전력선 통신의 특성상 채널의 범용적인 모델의 구성과 해석이 불가능하여 이론적인 성능특성을 파악하기가 힘들다. 따라서 개발된 기술의 평가 및 성능 분석에 있어 정확한 기준이 모호하다. 본 논문에서는 전력선 통신 기술의 특성과 성능을 분석하기 위하여, 실 단독주택 수용가에 인터넷 접속 환경을 구축하고 다양한 시험을 수행하였다. 개발된 전력선 통신 모뎀과 통신망의 구성을 소개하고 성능측정을 수행한 결과를 토대로 현 단계에서의 기술을 분석하고, 전력선 통신망에 대한 운영상의 적정 노드 및 가입자망 전송 섹터범위 등의 사항에 대하여 기술하였다.

굽은 비선형 도파로를 이용한 솔리톤 결합기 (Soliton coupler using a bent nonlinear waveguide)

  • 정준영;강병한;정제명
    • 한국광학회지
    • /
    • 제10권6호
    • /
    • pp.487-493
    • /
    • 1999
  • 본 논문에서는 굽은 비선형 도파로를 이용한 솔리톤 결합기의 동작 특성에 대해 알아 보았다. 이 굽은형 솔리톤 결합기는 기존의 솔리톤 결합기와 마찬가지로, 비선형 도파로에서의 솔리톤 방출의 문턱값 효과로 인해 매우 날카로운 스위칭 특성을 갖는다. 또한 이 결랍기의 굽은 구조는 솔리톤 방출을 위해 요구되는 최소 입력 파워의 문턱값을 낮추어 준다. 굽은형 솔리톤 결합기를 통한 파의 전송을 보다 정확하고 실제적으로 수치 해석하기 위해 비선형성의 포화 효과와 매질에서의 손실을 고려하였다. 시뮬레이션 결과는 포화 효과와 손실을 고려하는 것이 비선형 도파로 소자의 해석과 설계에 있어서 매우 중요하다는 것을 보여주고 있다. 이러한 굽은 구조의 적용은 포화 효과와 손실을 고려했을 때, 낮은 문턱값 파워를 가지고 공간 솔리톤을 방출시키는데 유용하다.

  • PDF

새로운 액티브 보조 공진 DC 링크 스너버를 이용한 3상 전압형 소프트 스위칭 인버터의 특성 (Characteristic of Three-Phase Voltage Type Soft-Switching Inverter using the Novel Active Auxiliary Resonant DC Link Snubber)

  • 성치호;허영환;문상필;박한석
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.114-121
    • /
    • 2016
  • This paper is Instant space vector PWM(Pulse Width Modulation)power conversion devices in switching power semiconductors from my generation to losses and switching when the voltage surge and current surge of electronic noise(EMI: Electro Magnetic Interference / RFI: Radio Frequency Interference)to effectively minimize the power soft-switching power conversion circuit topologies of auxiliary resonant DC tank for the purpose of high performance realization of the electric power conversion system by the high-speed switching of a semiconductor device(AQRDCT simultaneously : an active auxiliary resonance using auxiliary Quasi-resonant DC tank)DC link snubber switch has adopted a three-phase voltage inverter. AQRDCL proposed in this paper can reduce the effective and current peak stress of the power semiconductors of the auxiliary resonant snubber circuit compared to the conventional active-resonant DC link snubber, it is not necessary to install the clamp switch of the auxiliary resonant DC link, DC the peak current and power loss of the bus line can be reduced.

광계측 시스템을 이용한 유.기중 코로나 방전의 전계변화 측정 및 비교분석 (Analysis and the measurement of the variation of electric field in air and oil using optical measuring system)

  • 마지훈;류철휘;강원종;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1668-1670
    • /
    • 2002
  • Since more than two decades, the conventional PD detecting systems have been employed in order to detect the partial discharges occurring inside the HV power apparatus for their diagnosis by use of different type of detection such as acoustic and UHF detection method. Regardless of their wide on-site application, a certain number of technical inconveniences have been disclosed as follows : multistage amplification. large volume, susceptible to external noise and high price. In this respect, the optical measurement techniques are widely proposed in these days in this concerned field ascribed to the following advantages : immune to external EMI noise and broad band response of the Pockels cell covering from DC to GHz. However, the reliability of several proposed techniques enabling to measure the electric field inside the large high power apparatus has not yet been well approved In this work, an optical measuring system, based on the Pockels effect, has been developed for measuring the field variation due to the corona discharges occurring in air and in oil. This system consists of He-Ne laser, single mode optical fiber, multi mode optical fiber, polarizing film, Y-cut LiNbO3 cell, photo detector, digital oscilloscope and personal computer with GPIB. For this purpose, optical probe has been specially designed and realized and put into the needle-plane electrode. Afterward, same measurement is carried out in oil. We demonstrate the characteristic of the optical measuring system and the measurement results.

  • PDF

하이브리드 자동차 보조전원 공급용 DC-DC 컨버터 개발 (Development of DC-DC Converter for Ancillary Power Supply in Hybrid Electric Vehicle)

  • 김종철;최덕관;박해우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.261-265
    • /
    • 2005
  • 본 논문에서는 하이브리드 자동차용 보조전원 공급이 목적인 DC-DC Converter에 대하여 기술하였다. DC-DC Converter는 차량 내의 헤드램프, 오디오, 각종 ECU등 전기/전자 부하에 전력을 공급하며 또한 12V 보조 배터리를 충전하는데 사용된다. 고주파 동작 조건하에서 유기되는 전자파 노이즈와 스위칭 손실을 저감하기 위하여 컨버터 토폴로지로 위상천이 영전압 풀브리지 방식을 적용하였으며 제어기의 용이한 보상 및 안정된 시스템 응답 특성을 위하여 슬로프 보상이 포함된 전류 모드 제어방식을 사용하였다 정전압/정전류 충전 제어 방식은 전기부하에 안정적인 전원공급과 보조 배터리의 안정적인충전을 보장한다. 초기의 회로 파라메타 설정 및 하드웨어 디버깅을 위하여 시뮬레이션 툴로 PSIM 6.0을 사용하였으며. DC-DC Converter에서 스위칭 소자의 발열문제는 Thermo Tracer 장비를 사용하여 개선하였다.

  • PDF

스마트폰 기본 동작 모드에 따른 저주파 대역 누설 전자파 신호 특성 분석 (Low-Frequency Electromagnetic Leakage Signal Analysis According to Fundamental Operations of Smartphones)

  • 이영준;박희선;권영현;이재기;최지은;조상우
    • 한국통신학회논문지
    • /
    • 제41권9호
    • /
    • pp.1108-1119
    • /
    • 2016
  • 본 논문에서는 스마트폰의 저주파 대역 누설 전자파가 미치는 악영향을 분석하기 위해 스마트폰 모델별로 기본 동작에 따라 누설되는 30 MHz 이하의 누설 전자파 신호의 스펙트럼 특성 및 방사 패턴을 분석하였다. 사용자와의 직접적인 인터페이스를 담당하는 스마트폰의 입출력 센서 모듈(터치스크린, 카메라, 마이크 및 스피커 모듈)을 활성화시키는 4가지 기본 동작 모드에 의해 누설되는 전자파 신호를 상용 Near-Field 마그네틱 프로브를 통해 1cm의 격자 간격으로 정밀하게 측정하였다. 측정된 누설 전자파 신호를 분석한 결과, 스마트폰의 모델 및 동작 모드별로 누설되는 저주파 대역 전자파는 특이한 피크(Peak) 또는 하모닉(Harmonic) 피크 성분을 보이며, 동작 모드에 따라 각각의 입출력 센서 모듈이 활성화될 경우 해당 센서 모듈 및 메인보드 상의 AP(Application Processor), 메모리 주위로 상대적으로 강한 저주파 대역의 전자파가 누설되는 것을 확인할 수 있었다.