• Title/Summary/Keyword: EMG monitoring

Search Result 68, Processing Time 0.023 seconds

Analysis on Electromyogram(EMG) Signals by Body Parts for G-induced Loss of Consciousness(G-LOC) Prediction (G-induced Loss of Consciousness(G-LOC) 예측을 위한 신체 부위별 Electromyogram(EMG) 신호 분석)

  • Kim, Sungho;Kim, Dongsoo;Cho, Taehwan;Lee, Yongkyun;Choi, Booyong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.119-128
    • /
    • 2017
  • G-induced Loss of Consciousness(G-LOC) can be predicted by measuring Electromyogram(EMG) signals. Existing studies have mainly focused on specific body parts and lacked of consideration with quantitative EMG indices. The purpose of this study is to analyze the indices of EMG signals by human body parts for monitoring G-LOC condition. The data of seven EMG features such as Root Mean Square(RMS), Integrated Absolute Value(IAV), and Mean Absolute Value(MAV) for reflecting muscle contraction and Slope Sign Changes(SSC), Waveform Length (WL), Zero Crossing(ZC), and Median Frequency(MF) for representing muscle contraction and fatigue was retrieved from high G-training on a human centrifuge simulator. A total of 19 trainees out of 47 trainees of the Korean Air Force fell into G-LOC condition during the training in attaching EMG sensor to three body parts(neck, abdomen, calf). IAV, MAV, WL, and ZC under condition after G-LOC were decreased by 17 %, 17 %, 18 %, and 4 % comparing to those under condition before G-LOC respectively. Also, RMS, IAV, MAV, and WL in neck part under condition after G-LOC were higher than those under condition before G-LOC; while, those in abdomen and calf part lower. This study suggest that measurement of IAV and WL by attaching EMG sensor to calf part may be optimal for predicting G-LOC.

Intraoperative Neurophysiologic Monitoring and Functional Outcome in Cerebellopontine Angle Tumor Surgery (소뇌-교각종양 수술시 수술 중 전기생리학적 신경감시에 따른 수술 후 기능적 결과)

  • Lee, Sang Koo;Park, Kwan;Park, Ik Seong;Seo, Dae Won;Uhm, Dong Ok;Nam, Do-Hyun;Lee, Jung-Il;Kim, Jong Soo;Hong, Seung Chyul;Shin, Hyung Jin;Eoh, Whan;Kim, Jong Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.6
    • /
    • pp.778-785
    • /
    • 2000
  • Objectives : Intraoperative neurophysiologic monitoring(INM) is a well known useful method to reduce intraoperative neurological complications during neurosurgical procedures. Furthermore, INM is required in most cerebellopontine angle(CPA) surgery because cranial nerves or brain stem injuries can result in serious complications. Object of this study is to the correlation between the changes of intraoperative monitoring modalities during cerebellopontine angle tumor surgery and post-operative functional outcomes in auditory and facial functions. Material and Methods : Fifty-seven patients who underwent intraoperative neurophysiologic monitoring during CPA tumor surgery were retrospectively reviewed. Their lesions were as follows ; vestibular schwannomas in 42, other cranial nerve schwannomas in seven, meningiomas in five and cysts in three cases. Pre- and postoperative audiologic examinations and facial nerve function tests were performed in all patients. Intraoperative neurophysiologic monitoring modalities includes brainstem auditory evoked potentials(BAEP) and facial electromyographies(EMG). We compared the events of INM during CPA tumor surgeries with the outcomes of auditory and facial nerve functions. Results : The subjects who had abnormal changes during CPA tumor surgery were twenty cases with BAEP changes and facial EMG changes in twenty one cases. The changes of intraoperative neurophysiologic monitoring did not always result in poor functional outcomes. However, most predictable intraoperative monitoring changes were wave III-V complex losses in BAEP and continuous neurotonic activities in facial EMG. Conclusion : These results indicate that intraoperative neurophysiologic monitoring in CPA tumor surgery usually provide predictive value for postoperative functional outcomes.

  • PDF

Study for portable bladder function monitoring system (휴대용 방광기능 검사 장치에 대한 연구)

  • Kim, K.S.;Lee, S.O.;Lee, G.S.;Lee, T.H.;Kim, G.H.;Kim, H.J.;Jang, C.H.;Yoon, S.I.;Kim, C.H.;Chae, H.C.;Song, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.379-381
    • /
    • 2005
  • Urodynamics describes a collection of tests designed to evaluate lower urinary tract function and can be performed using retrograde filling of the bladder within a room. In this study, we designed and calibrated the potable urodynamics monitoring system using DSP chip (TMS320VC33, Texas InstrumentTM, U.S.) and obtained signals of bladder(Pves) and bladder neck pressure(Pneck) and EMG using calibration kit (DPT9022K0122, MedtronicsTM, U.s,). This system monitor spontaneous urination during daily life and can make patients more comportable.

  • PDF

Application of Neurophysiological Studies in Clinical Neurology (임상신경생리 분야에서의 신경생리적 검사법의 응용)

  • Lee, Kwang-Woo;Park, Kyung-Seok
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.1
    • /
    • pp.1-9
    • /
    • 1999
  • Since Hans Berger reported the first paper on the human electroencephalogram in 1920s, huge technological advance have made it possible to use a number of electrophysiological approaches to neurological diagnosis in clinical neurology. In majority of the neurology training hospitals they have facilities of electroencephalography(EEG), electromyography(EMG), evoked potentials(EP), polysomnography(PSG), electronystagmography(ENG) and, transcranial doppler(TCD) ete. Clinicials and electrophysiologists should understand the technologic characteristics and general applications of each electrophysiological studies to get useful informations with using them in clinics. It is generally agreed that items of these tests are selected under the clinical examination, the tests are performed by the experts, and the test results are interpretated under the clinical background. Otherwise these tests are sometimes useless and lead clinicians to misunderstand the lesion site, the nature of disease, or the disease course. In this sense the clinical utility of neurophysiological tests could be summerized in the followings. First, the abnormal functioning of the nervous system and its environments can be demonstrated when the history and neurological examinations are equivocal. Second, the presence of clinically unsuspected malfunction in the nervous system can be revealed by those tests. Finally the objective changes can be monitored over time in the patient's status. Also intraoperative monitoring technique becomes one of the important procedures when the major operations in the posterior fossa or in the spinal cord are performed. In 1996, the Korean Society for Clinical Neurophysiology(KSCN) was founded with the hope that it will provide the members with the comfortable place for discussing their clinical and academic experience, exchanging new informations, and learning new techniques of the neurophysiological tests. The KSCN could collaborate with the International Federation of Clinical Neurophysiology(IFCN) to improve the level of the clinical neurophysiologic field in Korea as will as in Asian region.1 In this paper the clinical neurophysiological tests which are commonly used in clinical neurology and which will be delt with and educated by the KSCN in the future will be discussed briefly in order of EEG, EMG, EP, PSG, TCD, ENG, and Intraoperative monitoring.

  • PDF

Development of a Remote Shoulder Rehabilitation Exercise Device and Monitoring System (원격 어깨재활 운동 디바이스 및 모니터링 시스템 개발)

  • Kang, Byeong-Gwon;Choi, Soon;Kim, Jea Min;Kang, Hyun-Joo;Min, Se Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.910-916
    • /
    • 2018
  • In this paper, we developed a shoulder rehabilitation exercise device and monitoring system to remotely provide rehabilitation system for the ones who need shoulder exercises including the patients with rotator cuff rupture. In order to evaluate the severity of shoulder muscle injury, a total of 4 shoulder rehabilitation exercises ((3) shoulder abduction, (2) shoulder flexion, (3) shoulder abduction with elbow flexion, (4) shoulder extension with elbow flexion) were selected and instructed to be performed with a 3 kg dumbbell for 5 times. For EMG (electromyogram) signal analysis, each subject's maximum voluntary contraction (MVC) was measured. EMG signals reflect the activation level of contracting muscles during dynamic exercises. Six participants' muscle activation levels in posterior deltoid, middle deltoid, upper trapezius, and infraspinatus were measured and compared. The mean power spectrum values in the time and frequency domains were compared between two age-matched groups (20s and 50s). The results showed lower muscle activation in the elderly subjects (n=3) compared to that of the ones in their twenties (n=3).

Development of a Knee Exoskeleton for Rehabilitation Based EMG and IMU Sensor Feedback (단계별 무릎 재활을 위한 근전도 및 관성센서 피드백 기반 외골격 시스템 개발)

  • Kim, Jong Un;Kim, Ga Eul;Ji, Yeong Beom;Lee, A Ram;Lee, Hyun Ju;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.223-229
    • /
    • 2019
  • The number of knee-related disease patients and knee joint surgeries is steadily increasing every year, and for knee rehabilitation training for these knee joint patients, it is necessary to strengthen the muscle of vastus medialis and quadriceps femoris. However, because of the cost and time-consuming difficulties of receiving regular hospital treatment in the course of knee rehabilitation, we developed knee exoskeleton using rapid prototype for knee rehabilitation with feedback from the electromyogram (EMG) and inertia motion unit (IMU) sensor. The modules was built on the basis of EMG and an IMU sensor applied complementary filter, measuring muscle activity in the vastus medialis and the range of joint operation of the knee, and then performing the game based on this measurement. The IMU sensor performed up to 97.2% accuracy in experiments with ten subjects. The functional game contents consisted of an exergaming platform based on EMG and IMU for the real-time monitoring and performance assessment of personalized isometric and isotonic exercises. This study combined EMG and IMU-based functional game with knee rehabilitation training to enable voluntary rehabilitation training by providing immediate feedback to patients through biometric information, thereby enhancing muscle strength efficiency of rehabilitation.

A New Approach Method of Measuring Abdominal Pressure for Urodynamic Monitoring System (요역동학 측정시스템을 위한 새로운 복압측정 기법)

  • Seo, Jeong-Hwan;Kim, Keo-Sik;An, Yang-Su;Kim, Kyeong-Seop;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1170-1176
    • /
    • 2007
  • The conventional urodynamic monitoring is fulfilled by artificially filling a bladder with saline. Generally. it is difficult to evaluate the physiological functions of the storage and voiding of a bladder. With this aim, we constructed an ambulatory urodynamic monitoring (AUM) system and proposed a novel method estimating abdominal pressure by measuring bio-impedance variations. Our system was clinically evaluated for 10 patients. It turned out to be that as the intensity of the abdomen contraction increased, the amplitude of bio-impedance signal and the RMS value of EMG increased more as compared to those who observed during the rest mode. Also, we determined the optimum electrode pair for estimating the abdominal pressure using bio-impedance method and consequently compared with the conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified in terms of impedance change, correlation coefficient and SNR Our results showed the optimum electrode pair (1,9) which could detect impedance changes due to the increase of the intensity in the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. Thus, our system demonstrated that the abdominal pressure could be measured noninvasively and conveniently by simply estimating bio-impedance values. We propose that this optimum electrode configuration would be useful for the future studies involving the handy measurements of abdominal pressure with our suggested ambulatory urodynamics monitoring system.

Effect of Visual and Palpation Feedback on Muscle Activity of Gluteus Maximus and Motion of Pelvic Rotation during Clam Exercise (크램 운동 시 시각-촉진 되먹임이 큰볼기근 활성도와 골반 회전에 미치는 영향)

  • Koh, Eun-Kyung;Jung, Do-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.5
    • /
    • pp.337-342
    • /
    • 2013
  • Purpose: This study was conducted in order to determine the effect of visual and tactile feedback on muscle activity of the gluteus maximus (Gmax) and abdominal muscles and the motion of pelvic rotation during performance of clam exercise (CE). Methods: Thirteen subjects without low back pain were recruited for this study. Each subject was instructed to perform the CE without and with feedback. The subjects were instructed to keep pelvic from rotating backwards by palpating the ASIS and monitoring the pelvic movement by themselves during performance of CE with feedback. The electromyographic (EMG) activities of Gmax and abdominal muscles were collected using surface EMG. Angles of pelvic rotation were measured using a 3-dimensional motion-analysis system. Paired t-tests were used for comparison of EMG activities in each muscle and the angle of pelvic rotation. Results: The EMG activities of all abdominal muscles were not significant between CM without and CM with feedback (p>0.05). The EMG activity of Gmax was significantly greater in CM with feedback compared with CM without feedback (without vs. with feedback; 14.2% vs. 20.7%MVIC) (p<0.05). The angle of pelvic rotation was significantly less in CM with feedback compared with CM without feedback (without vs. with feedback; $15.3^{\circ}$ vs. $10.8^{\circ}$ ) (p<0.05). Conclusion: Therefore, these findings suggest that CM with the visual and tactile feedback is effective in activation of the Gmax and correcting of the uncontrolled lumbopelvic rotation during CE.

Quantitative Rehabilitation Extent Monitoring for Unilateral Lower Extremity Disabled Patients using Simulated Gait Pattern Analysis (재활환자 모의보행 패턴분석을 이용한 하지 편측 장애자의 정량적 재활상태 모니터링)

  • Moon, Dong-Jun;Kim, Ju-Young;Noh, Si-Cheol;Choi, Heung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.227-233
    • /
    • 2014
  • In this paper, to quantitatively evaluate the degree of rehabilitation for the disabled of unilateral lower extremity, we compared the EMG pattern of normal and simulated abnormal gait. The EMG signal was measured at a rate of 1 kHz on the quadriceps and biceps femoris, the pressure sensor was attached to the sole in order to distinguish the gait cycle. Integrated EMG (IEMG) was obtained by the gait cycle, and classified four patterns that were the normal gait pattern, amplitude decrease pattern, reversed pattern, and irregular pattern. For comparison of the patterns, a curve fitting was performed using the trigonometric functions. The result of curve fitting, the method using a variable A that corresponds to the amplitude of the regression curve was able to distinguish the reverse pattern and remaining pattern. The coefficient of determination ($R^2$) representing coincidence of the pattern of the regression curve and EMG was confirmed the biggest value at the normal gait. Therefore, the degree of normal gait can be confirmed using the coefficient of determination. This results show that it is possible to quantitatively confirm the degree of unilateral lower extremity disabled rehabilitation, and it will be contributed to the study of efficient rehabilitation methods by objective analysis.

Development of Human-machine Interface based on EMG and EOG (근전도와 안전도 기반의 인간-기계 인터페이스기술)

  • Gang, Gyeong Woo;Kim, Tae Seon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.129-137
    • /
    • 2013
  • As the usage of computer based systems continues to increase in our normal life, there are constant efforts to enhance the accessibility of information for handicapped people. For this, it is essential to develop new interface ways for physical disabled peoples by means of human-computer interface (HCI) or human-machine interface (HMI). In this paper, we developed HMI using electromyogram (EMG) and electrooculogram (EOG) for people with physical disabilities. Developed system is composed of two modules, hardware module for signal sensing and software module for feature extraction and pattern classification. To maximize ease of use, only two skin contact electrodes are attached on both ends of brow, and EOG and EMG are measured simultaneously through these two electrodes. From measured signal, nine kinds of command patterns are extracted and defined using signal processing and pattern classification method. Through Java based real-time monitoring program, developed system showed 92.52% of command recognition rate. In addition, to show the capability of the developed system on real applications, five different types of commands are used to control ER1 robot. The results show that developed system can be applied to disabled person with quadriplegia as a novel interface way.