• 제목/요약/키워드: EMG monitoring

검색결과 68건 처리시간 0.025초

Surface EMG Network Analysis and Robotic Arm Control Implementation

  • Ryu, Kwang-Ryol
    • Journal of information and communication convergence engineering
    • /
    • 제9권6호
    • /
    • pp.743-746
    • /
    • 2011
  • An implementation for surface EMG network analysis and vertical control system of robotic arm is presented in this paper. The transmembranes are simulated by equivalent circuit and cable equation for propagation to be converted to circuit networks. The implementation is realized to be derived from the detecting EMG signal from 3 electrodes, and EMG transmembrane signals of human arm muscles are detected by several surface electrodes, high performance amplifier and filtering, converting analog to digital data and driving a servomotor for spontaneous robotic arm. The system is experimented by monitoring multiple steps vertical control angles corresponding to biceps muscle movement. The experimental results are that the vertical moving control level is measured to around 2 degrees and mean error ranges are lower 5%.

Effects of Activation of Gluteus Maximus and Abdominal Muscle using EMG Biofeedback on Lumbosacral and Tibiocalcaneal Angles in Standing Position

  • Koh, Eun-Kyung;Weon, Jong-Hyuck;Jung, Do-Young
    • The Journal of Korean Physical Therapy
    • /
    • 제25권6호
    • /
    • pp.411-416
    • /
    • 2013
  • Purpose: The purpose of the present study was to determine the effects of activation of gluteus maximus (Gmax) and abdominal muscle using EMG biofeedback on lumbosacral and tibiocalcaneal angles in standing position. Methods: Fourteen healthy subjects with normal feet participated in the present study. Electromyographic (EMG) biofeedback using visual cue was used to activate the external oblique (EO) and Gmax. The lumbosacral and tibiocalcalcaneal angles were measured by electronic goniometers. All the subjects were instructed to activate the Gmax and EO monitoring increasing amounts of the muscle activities in each muscle. The lumbosacral and tibiocalcaneal angles were collected in three trials during resting and activation of each muscle using EMG biofeedback in standing position. The mean value of three trials was used in the data analysis. A paired-t test was used to compare the lumbosacral and tibiocalcaneal angles between resting and activation of the Gmax and EO using EMG biofeedback. Results: The lumbosacral and tibiocalcaneal angles were significantly less in the resting compared to activation using EMG biofeedback (p<0.05). Conclusion: The activaition of Gmax and abdominal muscles using EMG biofeedback play role to control the pronation of subtalar joint during the weight-bearing.

휴대용 하부요로기능 검사 장치의 설계 (Design of ambulatory urodynamics monitoring system)

  • 이상옥;김거식;윤대영;서정환;송철규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.48-50
    • /
    • 2005
  • Urodynamics describes a collection of tests designed to evaluate lower urinary tract function and can be performed using retrograde filling of the bladder within a room. In this study, we designed and calibrated the potable urodynamics monitoring system using DSP chip (TMS320VC33, Texas Instrument$^{TM}$, U.S.) and collected pressure and EMG using calibration kit (DPT9022K0122, Medtronics$^{TM}$, U.S.). This system can make patients more comportable and monitor spontaneous urination during daily life.

  • PDF

유비쿼터스 기반 휴대용 방광기능 검사 장치 (Portable urodynamics monitoring system based on ubiquitous technology)

  • 김거식;안양수;송철규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.43-45
    • /
    • 2007
  • We developed a portable urodynamics monitoring system using personal digital assistance (PDA) and proposed a new method for measuring the abdominal pressure in non invasive mode using surface EMG signals. This system is consisted of a signal conditioning and control module and could measure the vesical, abdominal and detrusor pressure. The result showed a high correlation coefficient between the practical abdominal pressure, using a conventional rectal catheter and the estimated values, by our proposed algorithm (r=0.81). This system should prove a useful tool in the future evaluations of ambulatory urodynamics monitoring study.

  • PDF

저출력 레이저의 치료 효과 규명을 위한 근전도 신호의 피로도 해석 연구 (Muscle Fatigue Analysis Based on Electromyography Signals for The Evaluation of Low-Level Laser Therapy)

  • 김지현;최효훈;윤종인
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권4호
    • /
    • pp.319-327
    • /
    • 2011
  • Skeletal muscle fatigue is defined as a 'any reduction in the maximal capacity to generate force or power output', and is the reduction of oxygen consumption and by-product of metabolism. For the muscle fatigue therapy, low level laser has been introduced that leads the mitochondrial respiratory and attributes the muscle fatigue recovery. This study analyzed the muscle fatigue signals from electromyography(EMG) during low-level laser therapy (LLLT). Healthy subjects performed voluntary elbow flexion-extension excercise and received placebo LLLT and active LLLT using a 830 nm laser diode. Then, EMG were measured for the evaluation of muscle fatigue. The acquired EMG data were analyzed with median frequency and short time fourier transform methods. The results showed that the LLLT had a significant symptomatic relief of muscle fatigue based on the EMG frequency analysis. Therefore, the muscle fatigue analysis with EMG signals can be applied to quantitative evaluation for the monitoring of LLLT effects.

Electromyography-signal-based muscle fatigue assessment for knee rehabilitation monitoring systems

  • Kim, Hyeonseok;Lee, Jongho;Kim, Jaehyo
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.345-353
    • /
    • 2018
  • This study suggested a new EMG-signal-based evaluation method for knee rehabilitation that provides not only fragmentary information like muscle power but also in-depth information like muscle fatigue in the field of rehabilitation which it has not been applied to. In our experiment, nine healthy subjects performed straight leg raise exercises which are widely performed for knee rehabilitation. During the exercises, we recorded the joint angle of the leg and EMG signals from four prime movers of the leg: rectus femoris (RFM), vastus lateralis, vastus medialis, and biceps femoris (BFLH). We extracted two parameters to estimate muscle fatigue from the EMG signals, the zero-crossing rate (ZCR) and amplitude of muscle tension (AMT) that can quantitatively assess muscle fatigue from EMG signals. We found a decrease in the ZCR for the RFM and the BFLH in the muscle fatigue condition for most of the subjects. Also, we found increases in the AMT for the RFM and the BFLH. Based on the results, we quantitatively confirmed that in the state of muscle fatigue, the ZCR shows a decreasing trend whereas the AMT shows an increasing trend. Our results show that both the ZCR and AMT are useful parameters for characterizing the EMG signals in the muscle fatigue condition. In addition, our proposed methods are expected to be useful for developing a navigation system for knee rehabilitation exercises by evaluating the two parameters in two-dimensional parameter space.

Bilateral Pallidotomy for Dystonia with Glutaric Aciduria Type 1

  • Hwang, Hyung-Sik;Salles, Antonio De
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권5호
    • /
    • pp.380-383
    • /
    • 2005
  • Glutaric aciduria type 1 is an inborn error of lysine, hydroxylysine, and tryptophan metabolism caused by deficiency of glutaryl-coenzyme A dehydrogenase. The disease often appears in infancy with encephalopathy episode that results in acute basal ganglia and white matter degeneration. The majority of patients develop a dystonic-dyskinetic syndrome. This reports 6year-old boy who had been done previous gastrostomy due to swallowing difficulty underwent bilateral pallidotomy with intraoperative electromyography[EMG] monitoring for disabling dystonia. Intraoperative EMG was used to assess stimulation thresholds required for capsular responses and muscle tone. Surface EMG electrodes were placed on the face and cricopharyngeal muscles. Exact target were directly modified according to MRI-visualized anatomy. EMG response was consistently seen prior to visual observation of muscle activity. The surgery improved dystonic symptoms without swallowing difficulty.

성장기 부정교합환자의 근신경계 부조화를 해소한 증례: 교정치료 과정과 결과를 모니터링하기 위한 근전도검사(EMG)의 임상적 응용 (Clinical Application of Electromyography for Monitoring Procedure and Result of Orthodontic Treatment ; A of Three Cases)

  • 차봉근;이남기;최동순;김상호
    • 구강회복응용과학지
    • /
    • 제22권1호
    • /
    • pp.89-100
    • /
    • 2006
  • Traditionally, goals of orthodontic treatment fall into four categories: good tooth alignment, improvement of skeletal profile and good soft tissue, and rehabilitation of the normal function. Electromyography (EMG) has proven as useful tool in evaluating masticatory function among the maxillomandibular relationship and could be useful in accompanying orthodontic treatment objectives. But in pursuit of clinical application, it is necceassry to systemize clinical guideline for diagnosis by EMG records in evaluating the effects of orthodontic, orthopedic, or surgical treatment. This study present 3 orthodontic cases, which treatment results, ie neuromuscular balances of masticatory muscle, could be moitered by EMG procedure.

사용자 환경 모니터링을 위한 소형 자가발전 무선 데이터 송수신 시스템 개발 (Fabrication of Portable Self-Powered Wireless Data Transmitting and Receiving System for User Environment Monitoring)

  • 장순민;조수민;정윤수;김재형;김현수;장다연;라윤상;이동한;라문우;최동휘
    • Korean Chemical Engineering Research
    • /
    • 제60권2호
    • /
    • pp.249-254
    • /
    • 2022
  • 최근 반도체와 같은 정보통신 기술의 발전과 함께 사물인터넷(IoT) 기술 발전이 급격히 이루어지면서 센서와 무선 통신 기능을 내장하여 주변 사물 및 환경 조건을 감지 및 분석하여 대응하는 원격 환경 모니터링 기술이 주목받고 있다. 하지만, 기 개발된 원격 환경 모니터링 시스템은 모두 별도의 전원 공급 장치를 필요로 하기 때문에 시·공간적 기기 사용의 제한을 야기하여, 사용자의 불편함을 유발할 수 있다. 따라서, 본 연구에서는 생체 역학적 에너지의 역학적 특성이 고려된 기구학적 설계 기반 전자기 발전 소자(Electromagnetic generator, EMG)를 개발함으로써 이의 에너지 자립형 원격 환경 모니터링 구동을 위한 전원 공급 장치로써 활용한다. 낮은 진동 주기 및 큰 진폭 변화의 역학적 특성을 지닌 생체 역학적 에너지를 효과적으로 이용하기 위해 자석의 기구학적 배치를 통한 깨지기 쉬운 힘의 평형을 유도하는 Levitation-EMG (L-EMG)를 설계했다. 이를 통해, L-EMG는 외부 진동에 민감하게 반응하여 자석과 코일 간의 효과적인 상대 움직임을 야기하여 고품질 전기 에너지 공급을 가능하게 했다. 뿐만 아니라, 실제 환경 감지 센서와 무선 통신 모듈의 필요 전력을 최소화하기 위한 마이크로 컨트롤러(Micro control unit, MCU)를 구성하였으며, 내장기능 중 저전력모드(Sleep mode)를 접목하여 소비전력의 최소화 및 이의 구동시간 증가를 달성했다. 최종적으로 사용자의 편의성을 극대화하기 위해 휴대폰 어플리케이션을 구축하여 손쉽게 주변 환경 모니터링을 가능하게 했다. 따라서, 이번 연구는 생체역학적 에너지를 이용한 에너지 자립형 원격 환경 모니터링 구축 가능성을 검증할 뿐만 아니라, 더 나아가 별도의 외부 전원 없이 주변 환경 모니터링이 가능한 설계 방안을 제시할 수 있다.

Efficacy of Intraoperative Facial Electromyographic Monitoring in Patients with Hemifacial Spasm

  • Park, Hae-Kwan;Jang, Kyung-Sool;Lee, Kyung-Jin;Rha, Hyung-Kyun;Joo, Won-Il;Kim, Moon-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권3호
    • /
    • pp.183-187
    • /
    • 2006
  • Objective : Hemifacial spasm has characteristic and specific electrophysiological finding, lateral spread response[LSR]. We study the correlation between change of lateral spread response during microvascular decompression[MVD] and clinical outcome after MVD. Methods : Sixty two patients with hemifacial spasm who were treated with microvascular decompression from March 2000 to February 2003 were included in this study. The monitoring of intraoperative facial electromyography[EMG] and brain stem auditory evoked potential were performed. Results : In 28 [44.7%] patients, there was persistence of lateral spread response after vascular decompression in root exit zone of facial nerve. Among these 28 patients, 9 had mild hemifacial spasm at discharge. Three out of 34 patients who had intraoperative disappearance of lateral spread response after MVD had mild hemifacial spasm. But Both groups, disappearance of LSR [Group I], and persistence [Group II] had only 2 patients with mild hemifacial spasm, and 5 patients at 3 months, respectively. Conclusion : Although intraoperative EMG monitoring is very useful in assessing the efficacy of MVD, the clinical outcome of MVD in patient with hemifacial spasm does not always correlate with EMG finding. The prognostic value of intraoperative LSR monitoring in the long-term results is questionable.