• Title/Summary/Keyword: EMG 분석

Search Result 332, Processing Time 0.031 seconds

A Convergence Study of Surface Electromyography in Swallowing Stages for Swallowing Function Evaluation in Older Adults: Systematic Review (노인의 삼킴 단계별 삼킴 기능 평가를 위한 표면 근전도 검사의 융합적 연구 : 체계적 문헌고찰)

  • Park, Sun-Ha;Bae, Suyeong;Kim, Jung-eun;Park, Hae-Yean
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.5
    • /
    • pp.9-19
    • /
    • 2022
  • In this study, a systematic review was conducted to analyze the method of applying sEMG to evaluate the swallowing function of the elderly at each stage of swallowing, and to help objectively measure the swallowing stage of the older adults in clinical practice. From 2011 to 2021, 7 studies that met the selection criteria were selected using Pubmed, Scopus, and Web of Science (WoS). As a result of this study, the older adults and adults were divided into an experimental group and a control group and the swallowing phase was analyzed using sEMG only for the older adults. sEMG was used to evaluate swallowing in the oral and pharyngeal stages, and the sEMG attachment site was attached to the swallowing muscle involved in each stage. The collected sEMG data were filtered using a bandpass-filter and a notch-filter, and were analyzed using RMS, amplitude, and maximum spontaneous contraction. In this study, it was found that sEMG can be used as a tool to objectively and quantitatively evaluate the swallowing function in stages. Therefore, it is expected that this study will activate various studies that incorporate sEMG to evaluate the swallowing function in stages.

Analysis of Lower Extremity Muscle Activities in Parkinson's Patients for Improving to Stop Task (파킨슨 환자의 멈춤 보행 시 하지 근전도 분석)

  • Yang, Chang-Soo;Lim, Bee-Oh
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.3
    • /
    • pp.333-339
    • /
    • 2012
  • Freezing of gait is a severely problem in people with Parkinson's disease. The purpose of this study was to investigate the muscle activities of adductor longus, gluteus medius, gluteus maximus, biceps femoris, rectus femoris, gastrocnemius, and tibialis anterior using Noraxon 8 channels EMG system during stop task in patients with Parkinson's disease. Seven parkinson's patients and age matched normal participants were recruited in the study. Filtered EMG signals were rectified, smoothed and integrated. To control for the altered timing and magnitude of activity, iEMG was normalized for time and peak value. The results indicated that the patients with Parkinson showed decreased gait cycle, stance phase, swing phase time, swing phase time ratio and increased stance phase time ratio than normal participants. The patients with Parkinson showed decreased gastrocnemius muscle activity time ratio, while increased tibialis anterior muscle activity time ratio than normal participants. During stance phase before stop, the patients with Parkinson showed relatively lower average and peak iEMG in anterior tibialis and gastrocnemius muscle than normal participants. During swing phase before stop, the patients with Parkinson showed relatively higher average iEMG in gastrocnemius muscle than normal participants. During stop phase, the patients with Parkinson showed relatively lower average and peak iEMG in anterior tibialis and gastrocnemius muscle than normal participants.

A Computerized Analysis of Kinetic Posture and Muscle Contraction during a Weight Lifting Motion (역도경기(力道競技)의 운동학적(運動學的) 자세(姿勢)와 근수축(筋收縮) 수준(水準)에 관(關)한 전산분석(電算分析))

  • Lee, Myeon-U;Jang, Won-Gyeong;Seong, Deok-Hyeon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.9 no.2
    • /
    • pp.9-25
    • /
    • 1983
  • The purpose of this study was to film up computerized analyses for both kinematic posture(film analysis) and muscle dynamics (EMG) during a weight-lifting motion. (Snatch, Clean and Jerk) Using a motor drive camera (3.5 frames/sec) and a Location Analyzer, motion tracks of 13 landmarks, which were attached to the major joints, during the motion were converted into digital values. At the same time, EMG amplitudes from 11 major muscle groups were recorded. Recorded data were processed via analog/hybrid computer (ADAC 480) and digital computer (PDP 11/44). Landmark locations and EMG amplitude were integrated by a computerized routine. Computer output included graphic reproductions on sepuential dislocations of body segments, center of gravity of body segments and the associated changes on EMG amplitude such as % EMG's of major muscle group during a weight lifting motion. The results strongly suggest that the computerized motion-EMG integration can provide a further working knowledge in selection and in training of workers and athletes. Suggestions for a further study include additional device for velocity measurement, expansion of the link model for biomechanical analysis and other implementations necessary for athletic application.

  • PDF

Analysis on Electromyogram(EMG) Signals by Body Parts for G-induced Loss of Consciousness(G-LOC) Prediction (G-induced Loss of Consciousness(G-LOC) 예측을 위한 신체 부위별 Electromyogram(EMG) 신호 분석)

  • Kim, Sungho;Kim, Dongsoo;Cho, Taehwan;Lee, Yongkyun;Choi, Booyong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.119-128
    • /
    • 2017
  • G-induced Loss of Consciousness(G-LOC) can be predicted by measuring Electromyogram(EMG) signals. Existing studies have mainly focused on specific body parts and lacked of consideration with quantitative EMG indices. The purpose of this study is to analyze the indices of EMG signals by human body parts for monitoring G-LOC condition. The data of seven EMG features such as Root Mean Square(RMS), Integrated Absolute Value(IAV), and Mean Absolute Value(MAV) for reflecting muscle contraction and Slope Sign Changes(SSC), Waveform Length (WL), Zero Crossing(ZC), and Median Frequency(MF) for representing muscle contraction and fatigue was retrieved from high G-training on a human centrifuge simulator. A total of 19 trainees out of 47 trainees of the Korean Air Force fell into G-LOC condition during the training in attaching EMG sensor to three body parts(neck, abdomen, calf). IAV, MAV, WL, and ZC under condition after G-LOC were decreased by 17 %, 17 %, 18 %, and 4 % comparing to those under condition before G-LOC respectively. Also, RMS, IAV, MAV, and WL in neck part under condition after G-LOC were higher than those under condition before G-LOC; while, those in abdomen and calf part lower. This study suggest that measurement of IAV and WL by attaching EMG sensor to calf part may be optimal for predicting G-LOC.

A Study of Relationship Between EMG Activation of Thigh Muscle(Rectos Femoris, Vastus Iateralis Muscles) and Knee Angle During Bicycle Exercise (대퇴근활성화에 대한 자전거 운동 시 근전도와 슬관절 각도와의 상관관계 연구)

  • Jang, Won-Seuk;Kim, Sung-Min;Kang, Seung-Ho;Kim, Nam-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.77-83
    • /
    • 2009
  • In this study, we investigated relationship of muscular activity in thigh muscle and knee joint angle from bicycle exercise. The EMG signals of 16 persons were measured from rectus femoris and vastus lateralis muscles. The experiment was performed in 5 steps according to saddle distance and 60RPM/200W loads were applied for 1 minute at each step. EMG activation of rectus femoris and vastus lateralis muscles and knee joint angle were recorded using surface EMG and motion analysis system, respectively. Experimental results of inter relationship between EMG activation of thigh muscles and knee joint angle showed high correlation from Step 1. The unified EMG activation of two muscles and knee joint angle showed negative correlation(-0.97).

Development and Applications of a Wireless Bioelectric Signal Measurement System on the Electrodes (전극 상의 일체형 무선 생체전기신호 측정 시스템 개발 및 응용)

  • Joo, Se-Gyeong;Kim, Hee-Chan
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.88-94
    • /
    • 2003
  • Electromyogram (EMG) is the bioelectric signal induced by motor nerves. Analyzing EMG with the movement produced by muscle contraction, we can provide input commands to a computer as a man-machine interface as well as can evaluate the patient's motional abnormality. In this paper, we developed an integrated miniaturized device which acquires and transmits the surface EMG of an interested muscle. Developed system measures $60{\times}40{\times}25mm$, weighs 100g. Using an amplifier circuitry on the electrodes and the radio frequency transmission, the developed system dispenses with the use of cables among the electrodes, amplifier, and the post processing system (personal computer). The wiring used in conventional systems can be obstacle for natural motion and source of motion artifacts. In results, the developed system improves not only the signal-to-noise ration in dynamic EMG measurement, but also the user convenience. We propose a new human-computer interface as well as a dynamic EMG measurement system as a possible application of the developed system.

An EMG Analysis Study of Grinding Work by Posture and Working Time (연삭작업시 작업자세와 작업시간에 따른 근전도 분석에 관한 연구)

  • 배동철;장성록
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.79-83
    • /
    • 2001
  • Posture of the upper limbs in field works is known to be an important risk factor associated with CTD(Cumulative Trauma Disorders). In particular, uncomfortable posture and highly repetitive works in shipbuilding industry(for instance, sand blasting, grinding and blast painting, etc) made workers exposed to a great risk of injuries. The purpose of this paper is to analyze recruitment pattern of the muscles according to posture(joint angle displacement) during grinding. In this study, EMG signals of pectoralis major, latissimus dorsi, and posterior deltoid muscle were measured and analyzed from FlexComp EMG solution. And subjective ratings of perceived exertion were made using Borg's CR-10 rating scale.

  • PDF

A Study or Analysis of EMG Signals using Wavelet transform (웨이브렛 변환을 이용한 근전도 신호 분석에 관한 연구)

  • Kang, S.C.;Shin, C.K.;Lee, S.M.;Kwon, J.W.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.59-62
    • /
    • 1997
  • In this paper, we used Wavelet Transform to analyze EMG signals. Wavelet transform has an advantage of dividing the nonstationary signals into the high frequency and low frequency band effectively. For determining the characterized value of EMG signals, it was wavelet-transformed, absoluted, and integral-calculated. As the result, we acquired characterized value of each signals, and acknowledged the differences among them. It was concluded that the results of this study using wavelet transform could be used to powerful tool or analysis of EMG signals.

  • PDF

Kinetic Differences between Normal-design Running Shoes and Spring-loaded Running Shoes (기능성 스프링신발과 일반운동화의 운동역학적 비교분석)

  • Lee, Chong-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.3
    • /
    • pp.581-592
    • /
    • 2009
  • The purpose of this study is to examine the effect of the functional shoes through the kinetic comparison of normal-design running shoes and spring-loaded running shoes. For this, 12 healthy females from the age from 30 to 40 years participated in the EMG and ground reaction force experiment with testing kinetic variables. 12 subjects walked at the velocity of 1.7m/s. After analyzing variables in the spring-loaded running shoes and normal-design running shoes, the following conclusions were obtained; For the ground reaction force, spring-loaded running shoes have larger antero-posterior GRF than normal-design running shoes in the first and second apexes of antero-posterior ground reaction force. For the analysis of EMG, spring-loaded running shoes showed the higher muscle activation of rectus femoris muscle than norma-design running shoes. So the spring-loaded running shoes help improvement muscle strength of knee extensor.