• Title/Summary/Keyword: EM1D

Search Result 267, Processing Time 0.026 seconds

Iterative Series Methods in 3-D EM Modeling (급수 전개법에 의한 3차원 전자탐사 모델링)

  • Cho In-Ky;Yong Hwan-Ho;Ahn Hee-Yoon
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.3
    • /
    • pp.70-79
    • /
    • 2001
  • The integral equation method is a powerful tool for numerical electromagnetic modeling. But the difficulty of this technique is the size of the linear equations, which demands excessive memory and calculation time to invert. This limitation of the integral equation method becomes critical in inverse problem. The conventional Born approximation, where the electric field in the anomalous body is approximated by the background field, is very rapid and easy to compute. However, the technique is inaccurate when the conductivity contrast between the body and the background medium is large. Quasi-linear, quasi-analytical and extended Born approximations are novel approaches to 3-D EM modeling based on the linearization of the integral equations for scattered EM field. These approximation methods are much less time consuming than full integral equation method and more accurate than conventional Born approximation. They we, however, still approximate methods for 3-D EM modeling. Iterative series methods such as modified Born, quasi-linear and quasi-analytical can be used to increase the accuracy of various approximation methods. Comparisons of numerical performance against a full integral equation and various approximation codes show that the iterative series methods are very accurate and almost always converge. Furthermore, they are very fast and easy to implement on a computer. In this study, extended Born series method is developed and it shows more accurate result than that of other series methods. Therefore, Iterative series methods, including extended Born series, open principally new possibilities for fast and accurate 3-D EM modeling and inversion.

  • PDF

Design of a microstripe line ceramic dielectric filter (마이크로스트립라인 세라믹 유전체필터 설계)

  • Ko, Hee-Youl;Kim, Chung-Hoi;Kang, Byung-Don;Koo, Bon-Keup
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.712-715
    • /
    • 2012
  • 본 논문에서는 EM 시뮬레이터를 이용하여 LTE2300 대역의 마이크로스트립 라인 대역여파기를 설계하고 시편을 제작하였다. 중심주파수 2300MHz, 대역폭 350MHz, 삽입손실 1.5dB, 감쇄는 1930MHz와 2690MHz에서 15dB 이상, 1000MHz에서 60dB 이상으로 설계하였다. 또한 반사손실은 15dB로 설계하였다. 구현은 유전율 9.8인 알루미나 유전체에서 하였으며, 전송선로와 접지는 silver paste를 사용하였다. EM 시뮬레이션을 통해 얻은 결과값과 이를 통해 실제 제작된 시편의 보정값을 얻어 data base화 하였으며, 좋은 재현성을 얻을 수 있음을 확인하였다. 특히 일반적으로 마이크로스트립 라인 필터의 제작에 적용되는 에칭 또는 포토리소그라피 대신 레이저를 이용하여 패턴을 구현하였으며, 이 또한 우수한 특성과 재현성을 보여주었다.

  • PDF

A Study on EM Wave Absorber for Electromagnetic Wave Environment of Wireless LAN at 5.2 GHz (5.2 GHz 무선 LAN의 전자파 환경 대책용 전파흡수체에 관한 연구)

  • Yoo, Gun-Suk;Choi, Dong-Soo;Kim, Dong-Il
    • Journal of Navigation and Port Research
    • /
    • v.34 no.1
    • /
    • pp.15-19
    • /
    • 2010
  • Recently, the wireless LAN system is rapidly growing because of its convenience of high speed communication. However, the wireless LAN systems at indoor places occur multi-propagation path by reflected waves from walls, ceilings, floors, and desks. Multipath problems cause transmission errors and degradation of communication speed. These problems can be solved by using EM wave absorbers. In this paper, we analyzed property of Graphite and derived the optimum ratio of Graphite: CPE to develop EM wave absorber for the wireless LAN system. First, we fabricated several samples in different composition ratios of Graphite and CPE, and then measured the reflection coefficient of each samples. Material constants of permittivity and permeability were calculated using the measured data and designed EM wave absorber. Secondly, the EM wave absorber was fabricated and tested on the base of the simulation data. As a result, it showed that the EM wave absorber in 1.7 mm thickness with the ratio of Graphite: CPE=50:50 wt.% has excellent absorption ability more than 27 dB at 5.2 GHz.

An Efficient Design for an Ultra-Wideband Microstrip-to-CPS Transition Applicable to Millimeter-Wave Systems (밀리미터파 시스템에 적용 가능한 초광대역 마이크로스트립-CPS 전이구조 설계)

  • Kim, Young-Gon;Kim, Youn-Jin;Kim, Kang Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.3
    • /
    • pp.268-275
    • /
    • 2015
  • A clear and efficient design method for ultra-wideband microstrip-to-coplanar stripline(CPS) transition, which is based on the analytical expressions of the whole transitional structure, is presented. The conformal mapping is applied to obtain the characteristic impedance of the transitional structure within 3.2 % accuracy as compared with the EM-simulation results. The transition is designed to provide broadband impedance matching using Klopfenstein taper. The implemented transition performs less than 1 dB insertion loss per transition for frequencies from 5.39~40 GHz.

Consideration of EM Analysis for Unclonnable PUF (복제 방지용 PUF의 전자계 해석 방안)

  • Kim, Tae-Yong;Lee, Hoon-Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.80-82
    • /
    • 2012
  • In this paper, we present electromagnetic modeling to design unclonable PUFs with frequency-dependant materials corresponding to Debye dispersion. To demonstrate FDTD calculations consider that 1-D problem of pulsed plane wave traveling in free space normally incident on air-silicon material interface. The pulse traveling wave at a vacuum-medium interface were reflected, and transmitted wave were dissipated. As a result, 1-D PUF with Debye dispersion material structure can be applied and FDTD calculation for PUF modeling is a good approximation.

  • PDF

Electromagnetic Analysis to Design Unclonable PUF Modeling (복제 방지용 PUF 모델링을 위한 전자계 해석)

  • Kim, Tae-Yong;Lee, Hoon-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.6
    • /
    • pp.1141-1147
    • /
    • 2012
  • Electromagnetic analysis to design unclonable PUFs with frequency-dependant materials with Debye dispersion was considered. To simulate FDTD calculations consider that 1-D problem of pulsed plane wave traveling in free space normally incident on air-silicon material interface on dielectric substrate. The pulse traveling wave at a vacuum-medium interface was reflected, and transmitted wave was dissipated. As a result, 1-D PUF modeling with Debye dispersion on dielectric substrate structure can be applied and FDTD calculation for PUF modeling is a good approximation.

Analysis of EM Penetration Problems in Complex Structures Using Finite-Difference Time-Domain Method (FDTD 방법을 이용한 복잡한 구조물에서의 전자파 침투 특성 해석)

  • 김병남;채찬병;박성욱;이형수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.68-75
    • /
    • 2000
  • In this paper, we analyzed the radiation patterns of a monopole antenna mounted on cylinder and EM penetration problems in the complex structures by using FDTD method associated with 3-D PML absorbing boundary condition. In order to validate the proposed FDTD code, the radiation patterns of monopole antenna mounted on cylinders were compared with the exact Carter's solutions. As a results, the predicted radiation pattern exhibited excellent agreement with exact solution. And the FDTD code is applied to analyze the EM penetration problems in complex structures, Blackhawk helicopter. As the plane wave is excited, a significant amount of energy penetrates the helicopter structure, and it is dependent on aperture/airframe interface.

  • PDF

Cellular responses to 3D printed dental resins produced using a manufacturer recommended printer versus a third party printer

  • Beatriz Sona Cardoso;Mariana Brito da Cruz;Joana Faria Marques;Joao Carlos Roque;Joao Paulo Martins;Rodrigo Cordeiro Malheiro;Antonio Duarte da Mata
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.126-138
    • /
    • 2024
  • PURPOSE. The aim of this study was to evaluate the influence of different 3D dental resins, using a manufacturer recommended printer and a third-party printer, on cellular responses of human gingival cells. MATERIALS AND METHODS. Three NextDent resins (Denture 3D+, C&B MFH and Crowntec) were used to produce specimens on printers NextDent 5100 (groups ND, NC and NT, respectively) and Phrozen Sonic Mini 4K (groups PD, PC and PT, respectively). Human gingival fibroblasts were cultured and biocompatibility was evaluated on days 1, 3 and 7. IL-6 and IL-8 concentrations were evaluated at 3 days using ELISA. Surface roughness was evaluated by a contact profilometer. SEM and fluorescence micrographs were analyzed at days 1 and 7. Statistical analyses were performed using SPSS and mean differences were tested using ANOVA and post-hoc Tukey tests (P < .05). RESULTS. There was an increase in cellular viability after 7 days in groups PC and PT, when compared to group PD. ND group resulted in higher concentration of IL-6 when compared to PT group. SEM and fluorescence micrographs showed less adhesion and thinner morphology of fibroblasts from group PD. No significant differences were found regarding surface roughness. CONCLUSION. The use of different printers or resins did not seem to influence surface roughness. NextDent 5100 and Phrozen Sonic Mini 4K produced resins with similar cellular responses in human gingival fibroblasts. However, Denture 3D+ resin resulted in significantly lower biocompatibility, when compared to C&B MFH and Crowntec resins. Further testing is required to support its long-term use, required for complete dentures.

Response of a rocksalt crystal to electromagnetic wave modeled by a multiscale field theory

  • Lei, Yajie;Lee, James D.;Zeng, Xiaowei
    • Interaction and multiscale mechanics
    • /
    • v.1 no.4
    • /
    • pp.467-476
    • /
    • 2008
  • In this work, a nano-size rocksalt crystal (magnesium oxide) is considered as a continuous collection of unit cells, while each unit cell consists of discrete atoms; and modeled by a multiscale concurrent atomic/continuum field theory. The response of the crystal to an electromagnetic (EM) wave is studied. Finite element analysis is performed by solving the governing equations of the multiscale theory. Due to the applied EM field, the inhomogeneous motions of discrete atoms in the polarizable crystal give rise to the change of microstructure and the polarization wave. The relation between the natural frequency of this system and the driving frequency of the applied EM field is found and discussed.

Evaluation of short-term cardiac function by tissue Doppler imaging in pre and postoperative period of congenital heart disease (조직 도플러 영상을 이용한 선천성 심장병 수술 전후의 단기 심기능 평가)

  • Lee, Jun-Hwa;Kim, Yeo-Hyang;Hyun, Myung-Chul;Lee, Sang-Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.5
    • /
    • pp.476-483
    • /
    • 2007
  • Purpose : The objective of this study was to assess ventricular function by tissue Doppler imaging (TDI) in children with congenital heart disease (CHD) who have been undergoing open heart surgery (OHS) using cardiopulmonary bypass. We tried to compare the parameters of tissue Doppler imaging before and after OHS in patients with congenital heart disease. Methods : This study was conducted on 32 patients with CHD after OHS from January 2005 to December 2005 at Kyungpook National University hospital. Patients who underwent 2-D echocardiography before and after their OHS. All patients were divided into three groups, left ventricular volume overloading group (group 1), and right ventricular volume overloading group (group 2), and right ventricular pressure overloading group (group 3). The TDIs were examined before and 1 to 3 months after OHS. Peak early diastolic (E), and peak late diastolic (A) velocity of transmitral flow were measured by pulsed wave Doppler examination. Peak systolic (Sm), peak early diastolic (Em), and peak late diastolic (Am) velocity in apical 4-chamber and 2-chamber views were measured by TDI. The author calculated E/Em ratio. Results : The patients were 14 boys and 18 girls and the average age of patients was 2 years and 3 months. The congenital heart diseases which have to get OHS were ventricular septal defect (13 cases), atrial septal defect (7), atrioventricular septal defect (3), isolated pulmonary stenosis (2) and tetralogy of Fallot (7). There were significant decrease of Sm, Em, Am measured on tricuspid annulus and E/Em measured on mitral annulus in apical 4 chamber view (P<0.05). Conclusion : This study showed significant decrease of Sm, Em, Am measured on tricuspid annulus and E/Em measured on mitral annulus in apical 4 chamber view after OHS. These changes might be due to the effects of cardiopulmonary bypass in OHS and/or hemodynamic changes after correction of congenital heart disease. To clarify these changes, further study on more patients is needed.