• Title/Summary/Keyword: EM Field

Search Result 243, Processing Time 0.023 seconds

On-the-go Soil Strength Profile Sensor to Quantify Spatial and Vertical Variations in Soil Strength

  • Chung, Sun-Ok;Sudduth, Kenneth A.
    • Agricultural and Biosystems Engineering
    • /
    • v.6 no.2
    • /
    • pp.39-46
    • /
    • 2005
  • Because soil compaction is a concern in crop production and environmental pollution, quantification and management of spatial and vertical variability in soil compaction for soil strength) would be a useful aspect of site -specific field management. In this paper, a soil strength profile sensor (SSPS) that could take measurements continuously while traveling across the field was developed and the performance was evaluated through laboratory and field tests. The SSPS obtained data simultaneously at 5 evenly spaced depths up to 50 em using an array of load cells, each of which was interfaced with a soil-cutting tip. Means of soil strength measurements collected in adjacent, parallel transects were not significantly different, confirming the repeatability of soil strength sensing with the SSPS. Maps created with sensor data showed spatial and vertical variability in soil strength. Depth to the restrictive layer was different for different field locations, and only 5 to 16% of the tested field areas were highly compacted.

  • PDF

Estimation of Product Reliability with Incomplete Field Warranty Data (불완전한 사용현장 보증 데이터를 이용한 제품 신뢰도 추정)

  • Lim, Tae-Jin
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.28 no.4
    • /
    • pp.368-378
    • /
    • 2002
  • As more companies are equipped with data aquisition systems for their products, huge amount of field warranty data has been accumulated. We focus on the case when the field data for a given product comprise with the number of sales and the number of the first failures for each period. The number of censored items and their ages are assumed to be given. This type of data are incomplete in the sense that the age of a failed item is unknown. We construct a model for this type of data and propose an algorithm for nonparametric maximum likelihood estimation of the product reliability. Unlike the nonhomogeneous Poisson process(NHPP) model, our method can handle the data with censored items as well as those with small population. A few examples are investigated to characterize our model, and a real field warranty data set is analyzed by the method.

Electric Field Uniformity in Reverberation Chamber with 5 GHz Diffuser by Transmission Antenna (송신 안테나에 의한 5 GHz 이차 잔류 디퓨저를 적용한 전자파 잔향실의 내부 필드 균일도 변화)

  • Rhee, Eugene
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.83-86
    • /
    • 2021
  • In this paper, electric fields in electromagnetic reverberation chambers, which are used as a substitute facility for EM-free anechoic chambers, are analyzed. This paper focused on the 4-5 GHz band, which is expected to adversely affect equipment. To analyze the field uniformity inside the electromagnetic reverberation chamber, electric field strengths are sampled and finite-difference time-domain method was used for numerical analysis. Moreover, Quadratic residue diffuser was used to improve the characteristics of the electromagnetic reverberation chamber and the uniformity of the internal field strength. Standard deviation, tolerance characteristics, and partiality characteristics were compared while varying the aiming point of transmission antenna.

Effect of Borehole Fluid and Casing on the Borehole Electromagnetic Responses (공내수 및 케이싱이 시추공 전자탐사 반응에 미치는 영향)

  • Cho Seong-Jun;Kim Jung-Ho;Yi Myeong-Jong;Chung Seung-Hwan;Song Yoonho
    • Geophysics and Geophysical Exploration
    • /
    • v.2 no.2
    • /
    • pp.104-111
    • /
    • 1999
  • As a practical developing step of electromagnetic (EM) tomography technique, we quantitatively analyzed the effects of borehole fluid and casing on the borehole EM responses. The EM response turns out to have nothing to do with the property of the borehole fluid except in the close vicinity of the transmitter, which shows the wide perspective of the application of borehole EM. Single-hole responses in the presence of the steel casing throughly reflect those of the casing itself since its extremely high induction number or shallow skin depth. EM responses through steel casing do show the information of the host medium. In the near field region which corresponds to low frequency or the vicinity of the borehole, however, we can not separate the signal containing the information of the host from that of casing. Otherwise, the severe attenuation of energy in the casing at high frequencies renders the signal undetectable. The optimum frequency is, therefore, to be chosen to extract the information of the host considering both the property of the casing and the skin depth of the medium and the practical technique to determine the casing property through single-hole measurements is required.

  • PDF

A Study on Person Re-Identification System using Enhanced RNN (확장된 RNN을 활용한 사람재인식 시스템에 관한 연구)

  • Choi, Seok-Gyu;Xu, Wenjie
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.15-23
    • /
    • 2017
  • The person Re-identification is the most challenging part of computer vision due to the significant changes in human pose and background clutter with occlusions. The picture from non-overlapping cameras enhance the difficulty to distinguish some person from the other. To reach a better performance match, most methods use feature selection and distance metrics separately to get discriminative representations and proper distance to describe the similarity between person and kind of ignoring some significant features. This situation has encouraged us to consider a novel method to deal with this problem. In this paper, we proposed an enhanced recurrent neural network with three-tier hierarchical network for person re-identification. Specifically, the proposed recurrent neural network (RNN) model contain an iterative expectation maximum (EM) algorithm and three-tier Hierarchical network to jointly learn both the discriminative features and metrics distance. The iterative EM algorithm can fully use of the feature extraction ability of convolutional neural network (CNN) which is in series before the RNN. By unsupervised learning, the EM framework can change the labels of the patches and train larger datasets. Through the three-tier hierarchical network, the convolutional neural network, recurrent network and pooling layer can jointly be a feature extractor to better train the network. The experimental result shows that comparing with other researchers' approaches in this field, this method also can get a competitive accuracy. The influence of different component of this method will be analyzed and evaluated in the future research.

Frequency Sounding in Small-Loop EM Surveys (소형루프 전자탐사법에서의 주파수 수직탐사)

  • Cho In-Ky;Lim Jin-Taik
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.3
    • /
    • pp.119-125
    • /
    • 2003
  • The small-loop electromagnetic (EM) technique has been used successfully for many geophysical investigations, particularly for shallow engineering and environmental surveys. In conventional small loop EM operating at small induction numbers, geometric sounding has been widely used because the depth of penetration of EM energy depends only on the source-receiver separation. Recently developed small loop EM system, however, measures the secondary magnetic field, $H^S$, at multiple frequencies with a fixed source-receiver separation and frequency sounding is tried actively. In this study, we analyzed the behavior of in-phase and quadrature components of ${H^S}_z$, for horizonal coplanar (HCP) configuration over two-layer models. Through this theoretical analysis, it was found that the in-phase component of ${H^S}_z$ is more suitable for frequency sounding than the quadrature component. But, the in-phase component of ${H^S}_z$ is too small to measure, especially in resistive and noisy environment like Korea. Using the fact that the quadrature component is much greater than the in-phase component and the difference of quadrature component of ${H^S}_z$ measured at two frequencies shows the same behavoir as the in-phase component, we suggested an alternative frequency sounding technique. Also, we defined an apparent conductivity, which reflects well the conductivity of subsurface layers.

EM Responses of Buried Conductive Pipes Calculated by 3-D Finite Element Method (3차원 FEM 모델링에 의한 수평 도전성 관로의 전자기 반응 특성)

  • Chung Ho-Joon;Jung Hyun-Key;Park Yeong-Sue;Jo Chul-Hyun
    • Geophysics and Geophysical Exploration
    • /
    • v.3 no.2
    • /
    • pp.48-52
    • /
    • 2000
  • We have calculated and analyzed the electromagnetic responses of buried conductive pipes due to a horizontal magnetic dipole source on the pound using a three-dimensional (3-D) finite element method to provide useful guidelines for designing electromagnetic pipe locator and for field operation of the system. For single buried pipe, the horizontal component and the horizontal difference of the vertical component of magnetic field show peaks above the pipe. When comparing the width of response curves of both cases around the peak, horizontal difference of vertical component of magnetic field shows much narrower peak, 2 times narrower at a half of maximum amplitude, than that of horizontal component of magnetic field. Accordingly, we can pinpoint the horizontal location of pipe on the ground more accurately by measuring the horizontal difference of vertical component of magnetic fold. Moreover, it will have a merit in determining the depth of pipe, because the equation for depth estimation is defined just above the pipe. When there are two buried pipes separated by two meters with each other, the response of horizontal difference of vertical component of magnetic field has two separate peaks each of which is located above the pipe whereas horizontal magnetic field response has only one peak above the pipe just below the transmitter. Thus, when there exist more than a buried pipe, measuring the horizontal difference of vertical magnetic field can effectively detect not only the pipe under transmitter but also adjacent ones. The width of response curves also indicates higher resolving ability of horizontal difference of vertical component of magnetic field.

  • PDF

2.5 Dimensional EM Modeling considering Horizontal Magnetic Dipole Source (수평 자기쌍극자 송신원을 이용한 2.5차원 전자탐사 모델링)

  • Kwon Hyoung-Seok;Song Yoonho;Son Jeong-Sul;Suh Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.2
    • /
    • pp.84-92
    • /
    • 2002
  • In this study, the new modeling scheme has been developed for recently designed and tested electromagnetic survey, which adapts horizontal magnetic dipole with $1\;kHz\~1\;MHz$ frequency range as a source. The 2.5-D secondary field formulation in wavenumber domain was constructed using finite element method and verified through comparing results with layered-earth solutions calculated by integral equations. 2-D conductive- and resistive-block models were constructed for calculating electric field, magnetic field and impedance - the ratio of electric and magnetic fields which are orthogonal each other. This study showed that electric field and impedance are superior in identifying 2-D isolated-body model to magnetic field. In particular, impedance gives more stable results than electric field with similar spatial resolving power, because electric field is divided by magnetic field in impedance. Thus the impedance analysis which uses electric and magnetic fields together would give better result in imaging the shallow anomalies than conventional EM method.

A Study of Mobile Patient Identification System Using EM4095 (EM4095를 이용한 모바일 의료환자인식 시스템 연구)

  • Jo, Heung-Kuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2337-2342
    • /
    • 2010
  • There is a vast field of application for RFID(Radio Frequency IDentification) technology. In the case of hospitals, RFID can be used for organizing patient data. Generally, patient data has been handled with medical cards. In order to look up data about a patient, the medical card would have to be found first, within a lot of other medical cards, by hand or with a computer. This is a very inconvenient system. Also, if the card is searched by the name of the patient, fatal medical accidents may occur in cases of mix-ups. If remote RFID Tag monitoring systems are applied in this case, the patient data would be accessible in the hospital. This article will discuss the grafting of RFID systems and wireless data communicating technology. The EM4095 chip, which uses 125KHz carrier waves was used in this study. And a Bluetooth module was added for wireless data communication. The ATMEGA128 microcomputer was used to control the RFID system and wireless module. A LCD monitor was connected to the extension port for nurses to view patient data, and also, the same information was displayed on PC monitors for doctors to see. The circuit was designed to consume minimal amounts of electricity for portability, and to transmit Tag ID's in environments with a lot of noise. The article is concluded with a diagram of the whole system, and performance of each data transmitting section has been analyzed.

Analysis of the TEM Cells Having arbitrary Rectangular Septum by Using Moment Method (모멘트법을 이용한 임의의 구형 내부도체를 갖는 TEM Cell의 특성 분석)

  • 윤재훈;최익권
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.15 no.11
    • /
    • pp.898-908
    • /
    • 1990
  • This paper applies the moment method to analyze the transverse electromagnetic(TEM) cell with an inner conductor (septum) of arbitrary rectangular shape and location by employing quast static approximation. The EM field and the characteristic impedance so obtained are shown to be in good agreement with the available data from the previously published papers about the typical TEM cell structure with center septum of zero thickness.

  • PDF