Journal of the Korean Society of Food Science and Nutrition
/
v.27
no.6
/
pp.1152-1159
/
1998
In order to develop more rapid and reproducible analysis of biotin known as vitamin H, attempts were made to establish the condition for enzyme linked immunosorbent assay(ELISA) compared with traditional microbiological assay(MBA). Antibiotin and antiserum were obtained from the immunized rabbits injected with emulsion of biotin KLH conjugate and Freund's adjuvant. The antiserum showed cross reactivity on biocytin, a derivative of biotin, which is converted to biotin in intestine, at the rate of 177%(median inhibitory concentration(IC50)=12.58ppb), but not on other derivatives such as desthiobiotin, diaminobiotin and 2 imino biotin. Specific antibody for biotin was purified from the antiserum through protein A column and desalting column. The conditions of competitive direct ELISA (cdELISA) were established. Detection range of biotin concentration by cdELISA was 0.01∼300ng/ ml(ppb). In the spike test with milk, fruit flake and pine carrot juice, the correlation coefficient between two methods of MBA and ELISA was reliably consistent at the value of r=0.992. But detection of biotin by microbiological assay(MBA) was rather restricted in range and nonspecific. Detection range of biotin by MBA was 0.1∼0.5ng/ml(ppb). It showed cross reactivities on biocytin and desthiobiotin at the rate of 80.1% and 66.7%, respectively. In conclusion, ELISA revealed a significant improvement compared with MBA for the biotin detection in terms of sensitivity, detection range and cross reactivity. In addition, a variety of samples could be analyzed rapidly and conveniently at one time by using ELISA. These results strongly suggest that the ELISA is very promising for the practical application to detect biotin contents in a wide range of food stuffs.
Critical parameters affecting sensitivity and specificity of an enzyme-linked immunosorbent assay(ELISA) for detection of antibodies to avian infections bronchitis virus(IBV) were standardized. By adopting the optimized conditions an equation calculating ELISA antibody titers from the observations at single serum dilution was formulated. The purified antigen of IBV Mass-41 strain was dispensed into polystyrene microplate wells at a concentration of 300ng per well($100{\mu}l$) and the plates were coated by completey drying at $37^{\circ}C$. Diluted chicken serum and horseradish peroxidase conjugated goat anti-chicken IgG were added in order in $100{\mu}l$ volumes per well and allowed to react for 30 minutes each at room temperature. Just before use and after each reaction the plates were washed three times with distilled water. Finally o-phenylenediamine solution was added as an enzyme substrate. After incubation for another 15 minutes at room temperature absorbances were read at 492nm. Hyperimmune serum against Mass-41 strain was used as internal reference positive(IRP) serum. After repeated titration of IRP and negative serum, a constant titer of IRP was determined. Serum titrations were carried out for various sample sera together with IRP and negative sera and the observed titers of sample sera were corrected by reflecting the ratio between observed and constant titers of IRP serum. These corrected titers of the sample sera were plotted against sample/positive(S/P) OD ratios. All the OD's measured in the serum titrations were also corrected by substracting negative serum OD. The following equation was formulated from the above data; $Log_{10}$ ELISA titer=$5.568({\log}_{10}S/P)+4.161$ Thus it was possible to calculate ELISA titer by measuring absorbance at 1/400 single serum dilution. Titer measured by cross ELISA tests employing Mass-41 strain and three local IBV isolates were similar. These results suggest that the ELISA tests standardized in this study can be used for evaluating not only vaccinal immunity but also for infection status against fields IBV's.
Cronobacter muytjensii is an important foodborne pathogen as a potential risk in infant formula powder (IFP). To develop a new and sensitive method for the detection of Cronobacter spp. in IFP, an immunoglobulin G (IgG) specific for C. muytjensii (formerly known as Enterobacter sakazakii ATCC 51329) was developed. Further, an indirect noncompetitive enzyme-linked immunosorbent assay (INC-ELISA) was developed by using the anti-C. muytjensii IgG. As a result, this newly developed INC-ELISA method was found very sensitive for C. muytjensii with detection limit of $6.5{\times}10^3CFU/ml$ in pure culture and 1 cell/25 g of IFP. This INC-ELISA method also displayed excellent specificity for C. muytjensii showing no cross-reactivity with other strains of Cronobacter genus and 11 other foodborne pathogenic strains. These results show that the developed INC-ELISA method was very sensitive, efficient, and rapid for the detection of C. muytjensii. Hence, this method could be applied to the development of diagnostic kits for the rapid and easy detection of C. muytjensii.
A total of 198 sera from stray cats was assayed against Toxoplasma gondii antigen by western blot. Out of 198 sera assayed, 26 sera (13.1%) showed typical blot patterns against T gondii. When spotted by ELISA absorbance and indirect latex agglutination lest (ILAT) titer, all 26 cases were distributed over the cut-off value of ELISA whereas 24 cases (92.3%) were in the positive range of 1:32 or higher and 2 cases in negative range by ILAT. Among western blot negative 172 sera, 162 cases were negative in both ILAT and ELISA while 10 cases were reactive falsely such that three cases were ILAT positive with 1:32 titer and 9 cases were ELISA positive (2 cases overlapped). These 10 cases reacted peculiarly without typical binding pattern in Western blot. Sandwich-ELISA was performed with monoclonal antibodies (mAbs) of Tg563 (30 kDa, SAG 1), Tg505 (22 kDa, SAG2), Tg605 (43 kDa, SAG3), Tg556 (28 kDa, GRA2), Tg737 (32 kDa, GRA6). Tg695 (66 kDa, ROP2), Tg786 (42 kDa, ROP6), and Tg621 (32 kDa, anonymous but cytosolic) clone, respectively. All western blot-positive cases were in the positive range and negative cases in the negative range clearly. Among the 10 false reactive cases, 3 cases were in the positive range with one or more mAbs. All mAbs used in this study were confirmed to be specific to T. gondii infection as a standardized sandwich-ELISA to differentiate it from other pathogens.
We examined to develop the enzyme linked immunosorbent assay (ELISA) for determination of zearalenone in animal feeds. Zearalenone was first converted to 6'-(carboxymethyl) zearalenone oxime(zearalenone oxime) to get a coupling site and then conjugated to bovine serum albumin(BSA) for use as immunogen and to horseradish peroxidase(HRP) for use as enzyme marker. Antibody against zearalenone was obtained after 11 weeks of immunization of rabbit with zearalenone oxime-BSA. Cross reactivity of the antibody with ${\alpha}-zearalanol,\;{\beta}-zearalenol,\;{\alpha}-zearalanol\;and\;{\beta}-zearalanol$ were 168, 46, 26 and 20% respectiviely. A simple procedure was devised for the screening of zearalenone in feeds using ELISA. Feeds samples(5g) were extracted by blending with 25 ml of methanol-phospate butTered saline-dimethylformate(70 : 29 : 1) and the extract was filtered and aqueous filterate analyzed. It took only 1 hours to do whole procedure for the analysis of zearalenone in feeds by the direct competitive ELISA, and detectable limit was 1-100 ppb. Using this procedure, only 4 of 24 feed samples showed positive results with 3.93-7.43 ppb levels.
In order to detect pantothenic acid (PA), conditions for enzyme-linked immunosorbent assay (ELISA) were established. Anti-PA-BSA antibody was produced from rabbits immunized with PA-bovine serum albumin (BSA) conjugates which were prepared by the bromoacetyl chloride [Bc] method (PA-BSA[Bc]) and by the periodate oxidation [Po] method (PA-BSA[Po]). PA-BSA[Bc] and PA-BSA[Po] was used as a coating antigen for competitive indirect(ci)ELISA. The Anti-PA-BSA[Po] antibody on ciELISA showed no competitive reaction. The detection limit of PA by ciELISA using Anti-PA-BSA[Bc] antibody was 1 ppm. The Anti-PA-BSA[Bc] antibody showed little cross-reactivity to PA derivatives such as pantoyllactone, pantetheine, pantothenyl alcohol, and acetyl CoA. The detection limit of PA by microbiological assay (MBA) was 10 ppb. Assay recoveries of PA in egg, cow's liver, and lettuce by ciELISA were 109, 64, and 344%, respectively, comparing with the MBA results.
Background: Canine adenovirus type 2 (CAV-2) induces infectious laryngotracheitis in members of the family Canidae, including dogs. To date, no ELISA kits specific for CAV-2 antibody have been commercialized for dogs in Korea. Objectives: We aimed to develop new indirect enzyme-linked immunosorbent assay (I-ELISA) to perform rapid, accurate serological surveys of CAV-2 in dog serum samples. Methods: In total, 165 serum samples were collected from dogs residing in Chungbuk and Gyeongbuk provinces between 2016 and 2018. The Korean CAV-2, named the APQA1701-40P strain, was propagated in Madin-Darby canine kidney cells and purified in an anion-exchange chromatography column for use as an antigen for I-ELISA. The virus-neutralizing antibody titers of CAV-2 in the dog sera were measured by virus neutralization (VN) test. Results: We compared the results obtained between the VN and new I-ELISA tests. The sensitivity, specificity, and accuracy of new I-ELISA were 98.6%, 86.4% and 97.0% compared with VN test, respectively. New I-ELISA was significantly correlated with VN (r = 0.91). Conclusions: These results indicate that new I-ELISA is useful for sero-surveillance of CAV-2 in dog serum.
Park, Choi-kyu;Lyoo, Young-soo;Lee, Chang-hee;Jung, Jong-wook
Korean Journal of Veterinary Research
/
v.38
no.2
/
pp.314-318
/
1998
An establishment of effective control measures to PRRSV infection in swine industry depends on a sensitive and specific diagnosis to detect either viral antigen and/or antibodies to PRRSV. Several diagnostic methods are available to detect antibodies against PRRSV, including IPMA, IFA and ELISA tests have been successfully developed. Sensitivity of the indirect immunofluorescent assay in MA-104 cells using Korean field isolate PL96-1 was superior to that of VR-2332 and field isolate PL96-2. Sensitivity and specificity of the IFA test with PL96-1 were comparable to those of commercial ELISA test kit but ELISA test was more sensitive for the detection of declining antibodies to PRRSV in finishing pigs. In this study we concluded that IFA and ELISA test could be utilized to detect antibodies to PRRSV and the results generated from these two tests were comparable and there were no significant difference between these two tests.
Trichinella spiralis is one of the important zoonotic parasites with a wide variety of vertebrates hosts in nature. The purpose of this study were to analyze ESP(Excretory-Secretory Protein) antigen, to evaluate ELISA for the serological diagnosis of Trichinosis, and to survey T. spiralis infection in finishing pigs using the pepsin digestion method and ELISA in Korea. In the analysis of ESP antigen by SDS-PAGE and Western blot, 4 major bands (70, 55, 52.6, and 49 kDa) were revealed from the ESP antigen. Predilection sites of T. spiralis were the diaphragm, the tongue, masseter muscles, intercostal muscle, and hindlimb in orders in the experimentally infected rats. Sera from 581 swine were tested by ELISA with ESP antigen. The 54 (9.3%) sera were suspected as positive reactors, however, these 54 sera were determined as false positives by the use of Western blotting. This study demonstrated that the ELISA was not suitable for the examination of T. spiralis in pork. The diaphragm muscle samples of 251 finishing pigs were tested by the method of pepsin-digestion for the presence of Trichinella larvae, however, T. spiralis was not detected from the samples. We could not find out T. spiralis infection in pig in Korea pork.
An indirect double antibody enzyme-linked immunosorbent assay (ELISA) was developed for rapid detection of a new virus isolated from abnormally swimming salmonid fish, RVS (Retrovirus of salmonid). Results using brain tissue homogenates, and infected cell cultures are described. The sensitivity of the methods is $10^{2.6}$$TCID_{50}/100{\mu}l$ of the examined cell culture fluid. The specificity was confirmed by the ELISA inhibition test and virological examinations. Viral antigen could be detected in artificially infected fish tissue homogenates. The assay will allow the diagnosis of RVS-infected fish within a day.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.