• Title/Summary/Keyword: ELISA.

Search Result 2,992, Processing Time 0.035 seconds

Development of Enzyme-Linked Immunosorbent Assay for Rapid and Sensitive Analysis of Biotin (Biotin의 분석을 위한 효소면역측정법(ELISA)의 개발)

  • 이경애;손동화;고영태
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.27 no.6
    • /
    • pp.1152-1159
    • /
    • 1998
  • In order to develop more rapid and reproducible analysis of biotin known as vitamin H, attempts were made to establish the condition for enzyme linked immunosorbent assay(ELISA) compared with traditional microbiological assay(MBA). Antibiotin and antiserum were obtained from the immunized rabbits injected with emulsion of biotin KLH conjugate and Freund's adjuvant. The antiserum showed cross reactivity on biocytin, a derivative of biotin, which is converted to biotin in intestine, at the rate of 177%(median inhibitory concentration(IC50)=12.58ppb), but not on other derivatives such as desthiobiotin, diaminobiotin and 2 imino biotin. Specific antibody for biotin was purified from the antiserum through protein A column and desalting column. The conditions of competitive direct ELISA (cdELISA) were established. Detection range of biotin concentration by cdELISA was 0.01∼300ng/ ml(ppb). In the spike test with milk, fruit flake and pine carrot juice, the correlation coefficient between two methods of MBA and ELISA was reliably consistent at the value of r=0.992. But detection of biotin by microbiological assay(MBA) was rather restricted in range and nonspecific. Detection range of biotin by MBA was 0.1∼0.5ng/ml(ppb). It showed cross reactivities on biocytin and desthiobiotin at the rate of 80.1% and 66.7%, respectively. In conclusion, ELISA revealed a significant improvement compared with MBA for the biotin detection in terms of sensitivity, detection range and cross reactivity. In addition, a variety of samples could be analyzed rapidly and conveniently at one time by using ELISA. These results strongly suggest that the ELISA is very promising for the practical application to detect biotin contents in a wide range of food stuffs.

  • PDF

Studies on avian infectious bronchitis: II. Standardization of an indirect enzyme-linked immunosorbent assay (ELISA) for antibody measurement (닭 전염성 기관지염에 관한 연구: II. 간접 enzyme-linked immunosorbent assay(ELISA)에 의한 항체가 측정)

  • Chang, Chong-ho;Kim, Sun-joong
    • Korean Journal of Veterinary Research
    • /
    • v.29 no.4
    • /
    • pp.503-515
    • /
    • 1989
  • Critical parameters affecting sensitivity and specificity of an enzyme-linked immunosorbent assay(ELISA) for detection of antibodies to avian infections bronchitis virus(IBV) were standardized. By adopting the optimized conditions an equation calculating ELISA antibody titers from the observations at single serum dilution was formulated. The purified antigen of IBV Mass-41 strain was dispensed into polystyrene microplate wells at a concentration of 300ng per well($100{\mu}l$) and the plates were coated by completey drying at $37^{\circ}C$. Diluted chicken serum and horseradish peroxidase conjugated goat anti-chicken IgG were added in order in $100{\mu}l$ volumes per well and allowed to react for 30 minutes each at room temperature. Just before use and after each reaction the plates were washed three times with distilled water. Finally o-phenylenediamine solution was added as an enzyme substrate. After incubation for another 15 minutes at room temperature absorbances were read at 492nm. Hyperimmune serum against Mass-41 strain was used as internal reference positive(IRP) serum. After repeated titration of IRP and negative serum, a constant titer of IRP was determined. Serum titrations were carried out for various sample sera together with IRP and negative sera and the observed titers of sample sera were corrected by reflecting the ratio between observed and constant titers of IRP serum. These corrected titers of the sample sera were plotted against sample/positive(S/P) OD ratios. All the OD's measured in the serum titrations were also corrected by substracting negative serum OD. The following equation was formulated from the above data; $Log_{10}$ ELISA titer=$5.568({\log}_{10}S/P)+4.161$ Thus it was possible to calculate ELISA titer by measuring absorbance at 1/400 single serum dilution. Titer measured by cross ELISA tests employing Mass-41 strain and three local IBV isolates were similar. These results suggest that the ELISA tests standardized in this study can be used for evaluating not only vaccinal immunity but also for infection status against fields IBV's.

  • PDF

Development of an Indirect Non-Competitive Enzyme-Linked Immunosorbent Assay for the Detection of Cronobacter muytjensii in Infant Formula Powder (유아용 조제분유 내 Cronobacter muytjensii 검지를 위한 간접 비경합 면역분석법의 개발)

  • Song, Xinjie;Kim, Myunghee
    • The Korean Journal of Food And Nutrition
    • /
    • v.26 no.4
    • /
    • pp.936-944
    • /
    • 2013
  • Cronobacter muytjensii is an important foodborne pathogen as a potential risk in infant formula powder (IFP). To develop a new and sensitive method for the detection of Cronobacter spp. in IFP, an immunoglobulin G (IgG) specific for C. muytjensii (formerly known as Enterobacter sakazakii ATCC 51329) was developed. Further, an indirect noncompetitive enzyme-linked immunosorbent assay (INC-ELISA) was developed by using the anti-C. muytjensii IgG. As a result, this newly developed INC-ELISA method was found very sensitive for C. muytjensii with detection limit of $6.5{\times}10^3CFU/ml$ in pure culture and 1 cell/25 g of IFP. This INC-ELISA method also displayed excellent specificity for C. muytjensii showing no cross-reactivity with other strains of Cronobacter genus and 11 other foodborne pathogenic strains. These results show that the developed INC-ELISA method was very sensitive, efficient, and rapid for the detection of C. muytjensii. Hence, this method could be applied to the development of diagnostic kits for the rapid and easy detection of C. muytjensii.

Western blot analysis of stray cat sera against Toxoplasma gondii and the diagnostic availability of monoclonal antibodies in sandwich-ELISA

  • Sohn, Woon-Mok;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.37 no.4
    • /
    • pp.249-256
    • /
    • 1999
  • A total of 198 sera from stray cats was assayed against Toxoplasma gondii antigen by western blot. Out of 198 sera assayed, 26 sera (13.1%) showed typical blot patterns against T gondii. When spotted by ELISA absorbance and indirect latex agglutination lest (ILAT) titer, all 26 cases were distributed over the cut-off value of ELISA whereas 24 cases (92.3%) were in the positive range of 1:32 or higher and 2 cases in negative range by ILAT. Among western blot negative 172 sera, 162 cases were negative in both ILAT and ELISA while 10 cases were reactive falsely such that three cases were ILAT positive with 1:32 titer and 9 cases were ELISA positive (2 cases overlapped). These 10 cases reacted peculiarly without typical binding pattern in Western blot. Sandwich-ELISA was performed with monoclonal antibodies (mAbs) of Tg563 (30 kDa, SAG 1), Tg505 (22 kDa, SAG2), Tg605 (43 kDa, SAG3), Tg556 (28 kDa, GRA2), Tg737 (32 kDa, GRA6). Tg695 (66 kDa, ROP2), Tg786 (42 kDa, ROP6), and Tg621 (32 kDa, anonymous but cytosolic) clone, respectively. All western blot-positive cases were in the positive range and negative cases in the negative range clearly. Among the 10 false reactive cases, 3 cases were in the positive range with one or more mAbs. All mAbs used in this study were confirmed to be specific to T. gondii infection as a standardized sandwich-ELISA to differentiate it from other pathogens.

  • PDF

Development of Enzyme Linked Immunosorbent Assay for Determination of Zearalenone in Animal Feeds (가축사료 중 Zearalenone 분석을 위한 Enzyme Linked Immunosorbent Assay법의 개발)

  • 하정기;정덕화;김성영
    • Journal of Food Hygiene and Safety
    • /
    • v.6 no.3
    • /
    • pp.111-117
    • /
    • 1991
  • We examined to develop the enzyme linked immunosorbent assay (ELISA) for determination of zearalenone in animal feeds. Zearalenone was first converted to 6'-(carboxymethyl) zearalenone oxime(zearalenone oxime) to get a coupling site and then conjugated to bovine serum albumin(BSA) for use as immunogen and to horseradish peroxidase(HRP) for use as enzyme marker. Antibody against zearalenone was obtained after 11 weeks of immunization of rabbit with zearalenone oxime-BSA. Cross reactivity of the antibody with ${\alpha}-zearalanol,\;{\beta}-zearalenol,\;{\alpha}-zearalanol\;and\;{\beta}-zearalanol$ were 168, 46, 26 and 20% respectiviely. A simple procedure was devised for the screening of zearalenone in feeds using ELISA. Feeds samples(5g) were extracted by blending with 25 ml of methanol-phospate butTered saline-dimethylformate(70 : 29 : 1) and the extract was filtered and aqueous filterate analyzed. It took only 1 hours to do whole procedure for the analysis of zearalenone in feeds by the direct competitive ELISA, and detectable limit was 1-100 ppb. Using this procedure, only 4 of 24 feed samples showed positive results with 3.93-7.43 ppb levels.

  • PDF

An Enzyme-Linked Immunosorbent Assay for Detection of Pantothenic Acid (판토텐산의 분석을 위한 효소면역측정법)

  • Shon, Dong-Hwa;Park, Youn-Sick;Bae, Gun-Won
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.1009-1014
    • /
    • 2000
  • In order to detect pantothenic acid (PA), conditions for enzyme-linked immunosorbent assay (ELISA) were established. Anti-PA-BSA antibody was produced from rabbits immunized with PA-bovine serum albumin (BSA) conjugates which were prepared by the bromoacetyl chloride [Bc] method (PA-BSA[Bc]) and by the periodate oxidation [Po] method (PA-BSA[Po]). PA-BSA[Bc] and PA-BSA[Po] was used as a coating antigen for competitive indirect(ci)ELISA. The Anti-PA-BSA[Po] antibody on ciELISA showed no competitive reaction. The detection limit of PA by ciELISA using Anti-PA-BSA[Bc] antibody was 1 ppm. The Anti-PA-BSA[Bc] antibody showed little cross-reactivity to PA derivatives such as pantoyllactone, pantetheine, pantothenyl alcohol, and acetyl CoA. The detection limit of PA by microbiological assay (MBA) was 10 ppb. Assay recoveries of PA in egg, cow's liver, and lettuce by ciELISA were 109, 64, and 344%, respectively, comparing with the MBA results.

  • PDF

Development of indirect ELISA for the detection of canine adenovirus type 2 antibodies in dog sera

  • Yang, Dong-Kun;Kim, Ha-Hyun;Lee, Siu;Oh, Dongryul;Yoo, Jae Young;Hyun, Bang-Hun
    • Journal of Veterinary Science
    • /
    • v.21 no.4
    • /
    • pp.63.1-63.9
    • /
    • 2020
  • Background: Canine adenovirus type 2 (CAV-2) induces infectious laryngotracheitis in members of the family Canidae, including dogs. To date, no ELISA kits specific for CAV-2 antibody have been commercialized for dogs in Korea. Objectives: We aimed to develop new indirect enzyme-linked immunosorbent assay (I-ELISA) to perform rapid, accurate serological surveys of CAV-2 in dog serum samples. Methods: In total, 165 serum samples were collected from dogs residing in Chungbuk and Gyeongbuk provinces between 2016 and 2018. The Korean CAV-2, named the APQA1701-40P strain, was propagated in Madin-Darby canine kidney cells and purified in an anion-exchange chromatography column for use as an antigen for I-ELISA. The virus-neutralizing antibody titers of CAV-2 in the dog sera were measured by virus neutralization (VN) test. Results: We compared the results obtained between the VN and new I-ELISA tests. The sensitivity, specificity, and accuracy of new I-ELISA were 98.6%, 86.4% and 97.0% compared with VN test, respectively. New I-ELISA was significantly correlated with VN (r = 0.91). Conclusions: These results indicate that new I-ELISA is useful for sero-surveillance of CAV-2 in dog serum.

Comparison between indirect immunofluorescent antibody (IFA) test and enzyme-linked immunosorbent assay (ELISA) for the detection of antibody to porcine reproductive and respiratory syndrome virus(PRRSV) (돼지 생식기호흡기증후군 바이러스항체 검색에 있어 간접형광항체법(IFA) 과 효소면역법(ELISA)의 진단효율 비교)

  • Park, Choi-kyu;Lyoo, Young-soo;Lee, Chang-hee;Jung, Jong-wook
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.2
    • /
    • pp.314-318
    • /
    • 1998
  • An establishment of effective control measures to PRRSV infection in swine industry depends on a sensitive and specific diagnosis to detect either viral antigen and/or antibodies to PRRSV. Several diagnostic methods are available to detect antibodies against PRRSV, including IPMA, IFA and ELISA tests have been successfully developed. Sensitivity of the indirect immunofluorescent assay in MA-104 cells using Korean field isolate PL96-1 was superior to that of VR-2332 and field isolate PL96-2. Sensitivity and specificity of the IFA test with PL96-1 were comparable to those of commercial ELISA test kit but ELISA test was more sensitive for the detection of declining antibodies to PRRSV in finishing pigs. In this study we concluded that IFA and ELISA test could be utilized to detect antibodies to PRRSV and the results generated from these two tests were comparable and there were no significant difference between these two tests.

  • PDF

The survey of Trichinella spiralis infection in finishing pigs using the pepsin-digestion method and ELISA in Korea (조직인공소화법과 ELISA를 이용한 국내 출하돈의 선모충(Trichinella spiralis) 감염실태 조사)

  • Seo, Hunsu;Woo, Gye-Hyeong;Youn, Hee-Jeong
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.2
    • /
    • pp.269-277
    • /
    • 2004
  • Trichinella spiralis is one of the important zoonotic parasites with a wide variety of vertebrates hosts in nature. The purpose of this study were to analyze ESP(Excretory-Secretory Protein) antigen, to evaluate ELISA for the serological diagnosis of Trichinosis, and to survey T. spiralis infection in finishing pigs using the pepsin digestion method and ELISA in Korea. In the analysis of ESP antigen by SDS-PAGE and Western blot, 4 major bands (70, 55, 52.6, and 49 kDa) were revealed from the ESP antigen. Predilection sites of T. spiralis were the diaphragm, the tongue, masseter muscles, intercostal muscle, and hindlimb in orders in the experimentally infected rats. Sera from 581 swine were tested by ELISA with ESP antigen. The 54 (9.3%) sera were suspected as positive reactors, however, these 54 sera were determined as false positives by the use of Western blotting. This study demonstrated that the ELISA was not suitable for the examination of T. spiralis in pork. The diaphragm muscle samples of 251 finishing pigs were tested by the method of pepsin-digestion for the presence of Trichinella larvae, however, T. spiralis was not detected from the samples. We could not find out T. spiralis infection in pig in Korea pork.

Enzyme-linked immunosorbent assay (ELISA) for the detection of RVS (Retrovirus of Salmonid) (ELISA법을 이용한 연어과 어류의 RVS 검출(Retrovirus of Salmonid) 검출)

  • Oh, Myung-Joo;Yoshimizu, Mamoru
    • Journal of fish pathology
    • /
    • v.9 no.2
    • /
    • pp.169-176
    • /
    • 1996
  • An indirect double antibody enzyme-linked immunosorbent assay (ELISA) was developed for rapid detection of a new virus isolated from abnormally swimming salmonid fish, RVS (Retrovirus of salmonid). Results using brain tissue homogenates, and infected cell cultures are described. The sensitivity of the methods is $10^{2.6}$ $TCID_{50}/100{\mu}l$ of the examined cell culture fluid. The specificity was confirmed by the ELISA inhibition test and virological examinations. Viral antigen could be detected in artificially infected fish tissue homogenates. The assay will allow the diagnosis of RVS-infected fish within a day.

  • PDF