• Title/Summary/Keyword: ELISA method

Search Result 595, Processing Time 0.026 seconds

Preparation and Characterization of Anti-GP73 Monoclonal Antibodies and Development of Double-antibody Sandwich ELISA

  • Li, Qi-Wen;Chen, Hong-Bing;Li, Zhi-Yang;Shen, Peng;Qu, Li-Li;Gong, Lai-Ling;Xu, Hong-Pan;Pang, Lu;Si, Jin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.2043-2049
    • /
    • 2015
  • Background: Serum Golgi protein 73 (GP73) as a novel and potential marker for diagnosing hepatocellular carcinoma (HCC) have been found to be elevated in HCC patients and associated with clinical variables representing tumor growth and invasiveness. The aim of this study was to prepare a pair of monoclonal antibodys (mAbs) against GP73 and develop a newly designed double-antibody sandwich enzyme-linked immunosorbent assay (s-ELISA), which would be used in the detection of serum GP73 (sGP73) as well as in the diagnosis of HCC. Materials and Methods: Produced by prokaryotic expression, the purified recombinant GP73 (rGP73), produced by prokaryotic expression, was used to immunize the Balb/c mice. Two hybridoma cell lines against GP73 were obtained by fusing mouse Sp2/0 myeloma cells with spleen cells from the immunized mice. The titers of anti-GP73 mAb reached 1:243,000. Western blotting analysis and Immunohistochemistry staining revealed that anti-GP73 mAb could recognize GP73 protein. The double-antibody s-ELISA was successfully established and validated by 119 HCC and 103 normal serum samples. Results: showed that the detection limit of this method could reach 1.56 ng/ml, and sGP73 levels in HCC group (mean=190.6 ng/ml) were much higher than those of in healthy controls (mean=70.92 ng/ml). Conclusions: Results of our study not only showed that sGP73 levels of HCC patients were significantly higher than those of healthy controls, but also indicated that the laboratory homemade anti-GP73 mAbs could be the optimal tool used in evaluating sGP73 levels, which would provide a solid foundation for subsequent clinical applications.

Effects of epitope sequence tandem repeat and proline incorporation on polyclonal antibody production against cytochrome 1A2 and 3A4

  • Ahn, Tae-Ho;Yun, Chul-Ho
    • BMB Reports
    • /
    • v.42 no.7
    • /
    • pp.418-420
    • /
    • 2009
  • We describe a method for producing polyclonal antibodies against peptide antigen cytochrome P450 1A2 and 3A4 using a tandem repeat of the epitope region and incorporation of proline residue between the repeated sequences. An ELISA assay revealed more efficient generation of polyclonal antibodies to tandem repeat peptide antigens than mono-epitope peptides. The incorporation of proline residues further stimulated antibody production.

Characterization of Carnation mottle camovirus(CarMV) Isolated from Lilium spp. in Korea

  • Park, J.H.;J.H. Sung;H.Y. Shin;M.U. Chang;S.N. Yoo
    • Proceedings of the Korean Society of Plant Pathology Conference
    • /
    • 2003.10a
    • /
    • pp.150.2-150
    • /
    • 2003
  • Carnation mottle carmovirus(CarMV) was isolated from Lilium spp. in Korea. This isolate, CarMV, was done bioassay, which plants were Dianthus caryophyllus, Gomphrena globosa, Chenopodium amaranticolor, Dianths chinensis. CarMV was propagated on the leaves of Chenopodium amaranticolor with the crude-sap inoculation method and purified by Mossops method(1976). We produced antiserum against CarMV and analyzed the antiserum specificity with ELISA, Gel diffusion method, and Rapid Immunofilter Paper Assay (RIPA). From these results of the assay, RIPA method was simple and rapid for CarMV detection. We have established successfully the CarMV detection system. CarMV coat protein gene was amplified by RT-PCR with specific primers and sequencing analysis was done.

  • PDF

Comparative serological analysis of outer membrane proteins extracted from Brucella abortus Korean isolates and 1119-3 strains (Brucella abortus 국내 분리주의 세포외막 단백질 분석 및 혈청학적 비교)

  • Cha, Seung-Bin;Kang, Mi-Lan;Lee, Won-Jung;Shin, Min-Kyoung;Cho, Dong-Hee;Jung, Suk-Chan;Yoo, Han-Sang
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.4
    • /
    • pp.431-440
    • /
    • 2008
  • Brucellosis is one of the most important zoonosis in worldwide. As one of the control measures, attempts have been made to develop new diagnostic methods using filed isolates as a national policy in many countries. Currently, bovine brucellosis in Korea have been received attention in both public health and economical aspects due to sudden increase of outbreak. Based on the situation, we compared standard strain (B. abortus 1119-3) with field isolates to reveal the differences among them. Biological and biochemical charateristics, antibiotic resistance profiles, outer membrane proteins (OMPs) and lipopolysaccharide analysis of the strains were included in this study. For the diagnostic purpose, an attempt was made to find out a novel antigen from the Korean isolates by serological analysis. There were differences about 55 kDa, 36-38 kDa and 20 kDa in analysis of OMPs by SDS-PAGE and Western blot with positive sera ($\geq$ 1:400 in SAT titer). Also, a serological diagnostic method, ELISA was conducted using OMPs of the strains as novel antigen. Relationships between O.D. and SAT titer were analyzed using field sera showing different SAT titer. High correlation coefficient was observed between SAT titer and ELISA. Results from this study suggested that a new diagnsotic method should be developed using their own field isolates in each country.

Serological Studies on the Specific Antibodies Against P-pili of Uropathogenic Escherichia coli (요로 감염환자에서 혈청학적 방법을 이용한 P-pili특이혈중 항체의 조사)

  • 이원용;김종배
    • Biomedical Science Letters
    • /
    • v.2 no.1
    • /
    • pp.31-40
    • /
    • 1996
  • Escherichia coli is one of the most common etiological agents in urinary tract infection. An important virulence factor is the adhesive capacity of E. coli to uroepithelial cell, mediated by bacterial fimbriae. The Adhesion property has been regarded as an important virulence determinant in urinary tract infections. A total of 60 patients, who were diagnosed microbiologically as urinary tract infections, were examined by immunoblotting and enzyme-linked immunosorbent assay(ELISA). Uropathogenic E. coli with recombinant plasmid were positive for mannose resistant hemagglutination (MRHA). For identification of p-fimbriae subtype in uropathogenic E. coli, In the immunoblot analysis, specific bands in the range of p-fimbriae molecular weight of 17KD-22KD were identified. For the distribution of p-fimbriae subtype in the patient sera, 34/60(56.7%) were positive for $F7_1$, 28/60(46.7%) were positive for $F7_2$, and 30/60(50%) were positive for F13 with immunoblotting method. similar trends were observed in the enzyme-linked immunosorbent assay. Relatively good specificity(92.6%) and sensitivity(90%) were found in the ELISA test system using mixed antigens of purified $F7_1$, $F7_2$, and F13 p-fimbriae, and 60 sera from patients with urinary tract infections. In conclusion The serological tests were convenient method in diagnosis of urinary tract infections. among those ELISA could be recommended in diagnosis of urinary tract infections.

  • PDF

Performance comparison and evaluation of interferon-gamma assay kit for bovine tuberculosis diagnosis (소 결핵 진단을 위한 인터페론감마 검사 키트의 성능 비교 평가)

  • Hong, Leegon;Choi, Woojae;Ro, Younghye;Ahn, Sunmin;Kim, Eunkyung;Choe, Eunhee;Kim, Danil
    • Korean Journal of Veterinary Service
    • /
    • v.43 no.4
    • /
    • pp.201-209
    • /
    • 2020
  • In Korea, bovine tuberculosis (bTB) is a representative zoonotic disease that causes considerable economic loss. In determining the positive bTB, the ELISA method for examining the amount of interferon-gamma (IFN-γ) is included in Korea's diagnostic standard method. Recently, commercially available BIONOTE TB-Feron ELISA Plus (TB-Feron Plus) that detects IFN-γ has been introduced. However, since the scientific basis for the performance is limited, we evaluated performance by comparing it with the results of another IFN-γ ELISA assay kit (BOVIGAM®) certified by Office International des Epizooties. In our research, 42 positive blood samples preliminarily tested with a tuberculin skin test and/or BOVIGAM® and 54 negative blood samples collected from three bTB free farms were subjected to IFN-γ assay using the TB-Feron Plus and the BOVIGAM®, respectively. The result shows that the sensitivity, specificity and accuracy were 81.0% (34/42), 100% (54/54), 91.7% (88/96) in TB-Feron Plus kit and 78.6% (33/42), 100% (54/54), 90.6% (87/96) in BOVIGAM® kit, respectively. Moreover, the overall accordance percentage of the two kits was 99.0% (95/96) and there was almost perfect agreement between two assays (Kappa=0.977, P<0.0001). Furthermore, additional studies confirmed that elevated lymphocyte numbers in blood did not interfere with the results of the TB-Feron Plus kit. And, delayed time from sampling to culture decreased the optical density (OD) value. Therefore, we concluded that the TB-Feron Plus kit was not inferior to BOVIGAM® in performance. High lymphocyte numbers in blood did not impact on TB-Feron Plus results, while delayed time before culture interfered with OD value.

Comparison of Methods for Measuring Histamine by ELISA and HPLC-MS Assay In Vitro (In Vitro에서 히스타민 측정 시 ELISA법과 HPLC-MS 분석법의 비교)

  • Lee, In Hee;Kim, Yoo Hyun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.4
    • /
    • pp.306-312
    • /
    • 2015
  • The measurement of histamine is to determine the degree of allergy because the allergic reaction can lead to the release of histamine. In general, the antigen-antibody reaction was quantified by measuring absorbance using a microplate reader. In this study, we compare the method using a general antigen-antibody reaction and the method using a high performance liquid chromatography mass spectrometer (HPLC-MS) of chemical analysis in the measurement of histamine secretion. The cell line used was RBL-2H3, an allergic reaction was induced by stimulation with C48/80 (compound 48/80). Allergy-induced cells degranulation rate was confirmed by measurement of ${\beta}$-hexosaminidase and cytotoxicity was performed for the validity of the experiment. The quantitative determination of histamine showed a significant difference, since the quantitative limit of the measurement by the antigen-antibody reaction was 10.257 ppm while the quantitative limit of the measurement by HPLC-MS was 0.020 ppm. Measurement of histamine in allergic activity and anti-allergy tests showed that the HPLC-MS analysis rather than the analysis of the antigen-antibody reaction is a more precise and accurate test.

Enhancement of Sensitivity in Interferometric Biosensing by Using a New Biolinker and Prebinding Antibody

  • Park, Jae-Sook;Lim, Sung-Hyun;Sim, Sang-Jun;Chae, Hee-Yeop;Yoon, Hyun-C.;Yang, Sang-Sik;Kim, Byung-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.12
    • /
    • pp.1968-1976
    • /
    • 2006
  • Recombinant E. coli ACV 1003 (recA:: lacZ) was used to measure low concentrations of DNA-damaging chemicals, which produce $\beta$-galactosidase via an SOS regulon system. Very low $\beta$-galactosidase activities of less than 0.01 unit/ml, $\beta$-galactosidase produced through an SOS response corresponding to the 10 ng/ml (ppb) of DNA damaging chemicals in the environment, can be rapidly determined by using an alternative interferometric biosensor with optically flat thin films of porous silicon rather than by the conventional time-consuming Miller's enzyme assay as well as the ELISA method. fu order to enhance the sensitivity in the interferometry, it needs to obtain more uniform distribution and higher biolinking efficiency, whereas interferometric sensing is rapid, cheap, and advantageous in high throughput by using a multiple-well-type chip. In this study, pore size adjusted to 60 nm for the target enzyme $\beta$-galactosidase to be bound on both walls of a Si pore and a calyx crown derivative was apllied as a more efficient biolinker. Furthermore, anti-$\beta$-galactosidase was previously functionalized with the biolinker for the target $\beta$-galactosidase to be specifically bound. When anti-$\beta$-galactosidase was bound to the calyx-crown derivative-linked surface, the effective optical thickness was found to be three times as high as that obtained without using anti-$\beta$-galactosidase. The resolution obtained was very similar to that afforded by the time-consuming ELISA method; however, the reproducibility was still unsatisfactory, below 1 unit $\beta$-galactosidase/ml, owing to the microscopic non-uniform distribution of the pores in the etched silicon surface.

Establishment of Neospora agglutination test for serologic diagnosis of neosporosis (Neospora응집반응을 이용한 네오스포라증의 혈청학적 진단)

  • Kang, Min-Soo;Kim, Jae-Hoon;Hwang, Woo-Suk;Nam, Ho-Woo;Youn, Hee-Jeong;Bae, Jong-Hee;Kim, Dae-Yong
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.4
    • /
    • pp.677-681
    • /
    • 2003
  • Currently, both the indirect fluorescent antibody test (IFAT) and enzyme linked immunosorbent assay (ELISA) have been used to detect Neospora caninum antibodies. Several factors such as the buffers, the conjugate, the pattern of fluorescence, and the cross reactivity with other apicornplexan protozoan, may result in poorly correlated data. The present study was undertaken to develop and evaluate the Neospora agglutination test (NAT) for the detection and quantification of IgG antibodies to N. caninum from various animal species. Compared to the ELISA method, the NAT with a cutoff value of 1:512 gave a high index of coincidence (kappa=0.807) and no cross reactivity to Toxoplasma gondii antiserum. Hence, this NAT method, which did not require a species-specific secondary antibody and expensive tools, would be easily available for the detection of antibodies to N. caninllm of various animal species.

Cholera Toxin B Subunit-Porphyromonas gingivalis Fimbrial Antigen Fusion Protein Production in Transgenic Potato

  • Lee, Jin-Yong;Kim, Mi-Young;Jeong, Dong-Keun;Yang, Moon-Sik;Kim, Tae-Geum
    • Journal of Plant Biotechnology
    • /
    • v.36 no.3
    • /
    • pp.268-274
    • /
    • 2009
  • Porphyromonas gingivalis, the gram-negative anaerobic oral bacterium, initiates periodontal disease by binding to saliva-coated oral surface. The cholera toxin B subunit (CTB) genetically linked to FimA1 (1-200 aa) or FimA2 (201-337 aa) of the P. gingivalis fimbrial antigen were introduced into Solanum tuberosum cells by Agrobacterium tumefaciens-mediated transformation method. The integration of CTB-FimA1 or CTB-FimA2 fusion genes were confirmed in the chromosome of transformed leaves by genomic DNA PCR amplification method. Synthesis and assembly of the CTB-FimA fusion proteins into oligomeric structures with pentamer size was detected in transformed tuber extracts by immunoblot analysis. The binding activities of CTB-FimA fusion proteins to intestinal epithelial cell membrane receptors were confirmed by GM1-ganglioside enzyme-linked immunosorbent assay (GM1-ELISA). The ELISA showed that the expression levels of the CTB-FimA1 or CTB-FimA2 fusion proteins were 0.0019, 0.002% of the total soluble protein in transgenic tuber tissues, respectively The synthesis of CTB-FimA monomers and their assembly into biologically active oligomers in transformed potato tuber tissues demonstrates the feasibility of using edible plants for the production of enterocyte targeted fimbrial antigens that could elicit mucosal immune responses.