• Title/Summary/Keyword: ELF (extremely low frequency)

Search Result 73, Processing Time 0.028 seconds

반도체 산업의 웨이퍼 가공 공정 유해인자 고찰과 활용 - 화학물질과 방사선 노출을 중심으로 - (Review of Hazardous Agent Level in Wafer Fabrication Operation Focusing on Exposure to Chemicals and Radiation)

  • 박동욱
    • 한국산업보건학회지
    • /
    • 제26권1호
    • /
    • pp.1-10
    • /
    • 2016
  • Objectives: The aim of this study is to review the results of exposure to chemicals and to extremely low frequency(ELF) magnetic fields generated in wafer fabrication operations in the semiconductor industry. Methods: Exposure assessment studies of silicon wafer fab operations in the semiconductor industry were collected through an extensive literature review of articles reported until the end of 2015. The key words used in the literature search were "semiconductor industry", "wafer fab", "silicon wafer", and "clean room," both singly and in combination. Literature reporting on airborne chemicals and extremely low frequency(ELF) magnetic fields were collected and reviewed. Results and Conclusions: Major airborne hazardous agents assessed were several organic solvents and ethylene glycol ethers from Photolithography, arsenic from ion implantation and extremely low frequency magnetic fields from the overall fabrication processes. Most exposures to chemicals reported were found to be far below permissible exposure limits(PEL) (10% < PEL). Most of these results were from operators who handled processes in a well-controlled environment. In conclusion, we found a lack of results on exposure to hazardous agents, including chemicals and radiation, which are insufficient for use in the estimation of past exposure. The results we reviewed should be applied with great caution to associate chronic health effects.

휴대용 손 선풍기의 극저주파 자기장 발생 수준 평가와 쟁점 고찰 (Discussion of Exposure Evaluation Associated with Extremely Low Frequency-magnetic Field in the Case of Portable Hand-held Fans)

  • 박동욱;이성진;김소연;배서연;최상준;김원;민승현;박지훈;안종주
    • 한국환경보건학회지
    • /
    • 제44권5호
    • /
    • pp.480-490
    • /
    • 2018
  • Objective: This study aimed to report the level of extremely low frequency-magnetic field (ELF-MF) emitted by portable hand-held fans (HHF) and to discuss the methodologies for determining the health risk of ELF-MF for HHF products. Method: ELF-MF was monitored at eight locations by distances in the vicinity of HHFs. A total of 13 HHF brands on the market were randomly selected. A portable ELF-MF monitor MDEX II was used to measure the ELF-MF level in the range of 40-800 Hz with a resolution of $0.01{\mu}T$. This study also examined the frequency results of a total of 45 HHF products investigated by the Korean Ministry of Science and ICT (KMSICT). Results: ELF-MF higher than $0.3{\mu}T$ was found to be emitted at a distance of less than 20 cm from 12 HHF. ELF-MF emitted from four products was found to exceed the reference level ($83.3{\mu}T$ based on 60 Hz) recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). KMSIT reported that the principle frequency emitted from the HHFs ranged from 54 Hz to 284 kHz, without the level of LEF-MF. Unscientifically, the KMSICT used the reference level by ICNIRP as the chronic level and concluded that all HHFs are safe with a basis of 1.2-36.0% less than the reference level. Conclusion: The HHF emitted much higher levels of ELF-MF than $0.3-0.4{\mu}T$, which is regarded as the reference level for childhood leukemia. The risk of HHF should be examined in terms of whether they can be used by the general public, including children and pregnant woman.

Influence of Exposure to Extremely Low Frequency Magnetic Field on Neuroendocrine Cells and Hormones in Stomach of Rats

  • Hong, Min-Eui;Yoon, Kyu-Hyun;Jung, Yoon-Yang;Lee, Tae-Jin;Park, Eon-Sub;Sohn, Uy-Dong;Jeong, Ji-Hoon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제15권3호
    • /
    • pp.137-142
    • /
    • 2011
  • Extremely low frequency magnetic fields (ELF-MF) have the ability to produce a variety of behavioral and physiological changes in animals. The stomach, as the most sensitive part of the neuroendocrine organ of the gastrointestinal tract, is crucial for the initiation of a full stress response against all harmful stress. Thus, the purpose of this study was to examine whether ELF-MF stimuli induce changes in the activity of neuroendocrine cells, considering their involvement in endocrine or paracrine effect on surrounding cells. The exposure to ELF-MF (durations of 24 h and 1 or 2 weeks, 60 Hz frequency, 0.1 mT intensity) altered the distribution and occurrence of gastrin, ghrelin and somatostatinpositive endocrine cells in the stomach of rats. The change, however, in the secretion of those hormones into blood from endocrine cells did not appear significantly with ELF-MF exposure. Comparing with sham control, ELF-MF exposure for 1 and 2 week induced an increase in $BaSO_4$ suspension propelling ratio of gastrointestinal tract, indicating that ELF-MF affects gastrointestinal motility. Our study revealed that ELF-MF exposure might influence the activity of endocrine cells, an important element of the intrinsic regulatory system in the digestive tract. The pathophysiological character of these changes and the mechanism responsible for neuroendocrine cell are still unclear and require further studies.

극저주파 자계의 노출 평가에 대한 연구 (A Study on the Exposure Assessment of Extremely Low Frequency Magnetic Fields)

  • 김응식;김명훈;민석원
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.33-40
    • /
    • 2017
  • This paper addresses the assessment methods used to evaluate the magnetic exposure of a human to ELF EMF (Extremely Low Frequency Electromagnetic Field) which is caused by the process of power delivery from 60 Hz commercial power. These days the main concern is primarily focused on the magnetic field. For the exposure assessment, both numerical studies and laboratory experiments were studied and the results of the two compared for methodological suitability. The numerical analyses employ the Impedance Method (IM), Boundary Element Method (BEM), and Finite Element Method (FEM) and the laboratory experiments used various human phantom models made with conductivities congruent to human organs and then exposed to uniform/non-uniform magnetic fields to produce eddy currents. Under these conditions a number of examples have been evaluated and the reliability assessed to present the pros and cons of each methodology.

60Hz ELF 자계에 의한 인체내부 유도 전류밀도 해석 (Analysis on Induced Current Density Inside Human Body by 60 Hz ELF Magnetic Fields)

  • 민석원;송기현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권2호
    • /
    • pp.76-81
    • /
    • 2006
  • This paper analysed the characteristics of current density induced inside human body by 60 Hz extremely low frequency magnetic fields according to varying conductivities of human model. Human model was composed of several organs and other parts, whose shapes were expressed by spheroids or cylinders. Organs such as the brain, heart, lungs, liver and intestines were taken into account. Applying the boundary element method to the human model, we estimated effects on the induced current distribution due to differences of the organ conductivity and shape. We find organ conductivity influences most and a cross section area and a position of organ also gives effects.

송전선과 분전반 모선으로부터 발생하는 극저주파 자기장 저감을 위한 연구 (Study on minimizing Extremely-Low-Frequency magnetic fields around power cables and busbars)

  • 로우밍;정기우;김동훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.88-90
    • /
    • 2009
  • Extremely-Low-Frequency(ELF) magnetic fields are generated around power cables and bus bars in power systems. Such the stray fields may cause disturbances to nearby electronic apparatus and affect even human health. In order to seeking out a proper way to reducing the fields, the first thing to do is to accurately predict field distribution around analysis models of interest. Then, optimization techniques should be applied for finding a more improved design than the initial one. To achieve this goal, commercial electromagnetic software, MagNet, is combined with evolution strategy algorithm. For verification of the proposed method, three-phase power line cables and busbar systems have been tested.

  • PDF

The influence of extremely low frequency magnetic field on cardiovascular response

  • Kim, Jeong-Soo;Jeong, Ji-Hoon;Sung, Ji-Hyun;Bae, Ki-Lyong;Kum, Chan;Kang, Hee-Yun;Sohn, Uy-Dong
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.274.1-274.1
    • /
    • 2002
  • There have been some reports showing that cardiovascular response is affected by exposure to extremely low frequency magnetic field (ELF-MF). In this experiment. we intended to observe if ELF-MF affects the basal level of cardiovascular response and effect of drugs acting on sympathetic nervous system. Rats exposed to MF (60 Hz. 20 G) for 1 or 5 days and sham were anesthetized with pentobarbital-Na. Carotid artery and jugular vein were intubated to measure blood pressure (BP) and inject drug respectively. (omitted)

  • PDF

The effects of extremely low frequency magnetic field on bicuculline, picrotoxin, NMDA-induced seizures in mice

  • Sung, Ji-Hyun;Jeong, Ji-Hoon;Kim, Jeong-Soo;Kum, Chan;Park, Sun-Young;Sohn, Uy-Dong
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.274.2-274.2
    • /
    • 2002
  • Some experiments have been reported that magnetic fields can cause the change of numerous neurotransmitters including excitatory and inhibitory transmitters, which are involved in seizures. In this study we aimed to examine the effect of extremely low frequency magnetic field (ELF-MF) on the sensitivity of seizure response to bicuculline, picrotoxin and NMDA in mice. Mouse were exposed to sham or 20 G ELF-MF for 24 hours and then convulsants were administered i.p. at various doses. (omitted)

  • PDF