• Title/Summary/Keyword: ELB(Earth Leakage Breaker)

Search Result 31, Processing Time 0.02 seconds

A Study on Dynamic Characteristics of Electrical Fire Prevention Control Devices with a lamp and a motor load (전등 부하 및 전동기 부하시 전기화재예방 제어장치의 동작 특성에 관한 연구)

  • Lee, Sang-Ho;Oh, Hong-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.3
    • /
    • pp.255-260
    • /
    • 2002
  • Recently, the occurrences of electrical fire have been suppressed by an earth leakage breaker(ELB), a no fuse breaker(NFB) and a fuse in case of an earth leakage, a short circuit and an over current. But it is impossible for the ELB to break the circuit in the case of the failure of pressure contacts on connecting points and the momentary short circuit. Therefore, it is require to study the constructive problem of the ELB. In this paper, we have developed the auxiliary control device, electrical fire prevention control device(EFPCD), of the ELB. And we have tested the operation characteristics of the ELB according to the load(R, L) As a result of this experiment, we could prevent the electrical fire due to the spark and the overheat occurring in the failure of pressure contacts on connecting points and the momentary short circuit.

  • PDF

Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function (화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구)

  • Ko, Wan-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • The purpose of this study is to develop an earth leakage alarm circuit breaker, equipped with a leakage alarming function (JER-E2S, ETECKOREA Co., Korea), and to analyze its characteristics. The developed mechanism is exclusively used for single-phase and 220 V circuits, with a rated current of 32 A, 20 A, 20 A (for restrooms), 16 A, etc. It satisfies all characteristics of existing earth leakage circuit breakers (ELB). If a fire current, which is a resistive leakage current (Igr), flows through an electric line, the device detects the leakage current in real time and warns against the leakage through a blinking LED lamp. Since the developed device displays a tolerance to a capacitative leakage current (Igc) that inevitably occurs in LED lamps, communication devices, etc., it ensures a stable power supply. In addition, the earth leakage alarm circuit breaker protects against power failure due to a momentary ground fault. Therefore, it can supply power without the risk of the circuit breaker malfunctioning due to a momentary ground fault caused by water droplets, leaves, etc. Moreover, with a standby power of less than 0.1 W, the developed earth leakage alarm circuit breaker exhibits a power saving performance that is 3~8 times greater than that of other ELBs. Installation of approximately 10 earth leakage alarm circuit breakers in one apartment household, with an area of 120 ㎡, can save 2~5 kWh per month. Therefore, the developed earth leakage alarm breaker not only satisfies the characteristics of existing earth leakage breakers, but also exhibits outstanding power supply quality since it has the functions of electric fire prevention and malfunction prevention. Therefore, this device can innovatively contribute to electric fire prevention.

Electric Fire Hazard in Low Voltage Distribution Circuits Protected by Electric Leakage Circuit Breaker(ELB) (누전차단기로 보호되는 저압선로에서의 발화위험성)

  • 홍성호;김두현
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.93-99
    • /
    • 2000
  • This paper presents a study on the assessment of electrical fire hazards by electric circuits with leakage. The hazards are evaluated with the energy supplied by earth-leakage currents which flow in the circuits simulating the actual circuit of domestic premises. Also, operating time and current of ELB are measured by an experimental approach. A common specification of ELB used in this paper has a sensitivity of 30[mA] for leakage current working on the current-balance principle. Total charges and energy of leakage currents are calculated quantitatively by a theoretical approach and compared with the results obtained from experiments.

  • PDF

Analysis of Characteristic for Electric Leakage Component at Stable Size (축사 규모별 누전성분 특성 분석)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.54-58
    • /
    • 2012
  • This paper is purposed to analyze electric leakage component which can prevent electrical fires on breaker capacity expansion and power failure by operation of ELB(Earth leakage breaker) for stable sizes. In order to analysis for electric leakage component for stable sizes, this paper studied field state investigation which are at stable companies( 10 companies) in cheong-won location to deduce the problems of electric leakage component is analyzed. The field state experiment method is measured with electric leakage component which load part of ELB detected by electric loads(electrical fan, lighting, auto waterer, feeder and halogen lighting) and stable sizes. Results show that electric leakage component suggested in this paper are valuable and usable to electrical fire in leakage current based on environment factor, which will prevent severe damage to human beings and properties and reduce the electrical fires in stable.

Failure of Earth Leakage Breaker and Power Quality Analysis in Office Buildings (사무용 빌딩에서의 누전차단기 오동작과 전력품질 분석)

  • Lee, Sang-Ick;Yoo, Jae-Geun;Jeong, Jong-Wook;Lim, Yong-Bae;Jeon, Jeong-Chay
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.211-216
    • /
    • 2004
  • This paper presented a actual conditions on a false-tripping of ELB(Electrical Leakage Breaker) and an assessment of the harmonics due to non-linear electronic equipment such as personal computers, printers, fax machines, and test equipments in several office buildings. Actual conditions on a failure of ELB were surveyed and analyzed by making up a question to safety managers of in office buildings. Also, power quality measurements such as harmonic currents, voltage and current waveforms and current imbalance were made at various office buildings where nuisance tripping of ELB is often occurred. The results of this study can be used in making decisions regarding cause of ELB trip and operating md tripping characteristics test of ELB when subjected to distorted current waveforms.

  • PDF

A Study on the Characteristics of ELB Insulating Material deteriorated by Salt water (염수에 의해 열화된 누전차단기 절연재료의 특성에 관한 연구)

  • Kim, Hyung-Rae;Kim, Dong-Ook;Kim, Hyeog-Soo;Choi, Chung-Seog;Kim, Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.878-881
    • /
    • 2001
  • In this paper, we analyzed the characteristics of insulating material with ELB(earth leakage circuit breaker) through tracking experiment and the study was carried out three different types of samples. The tracking is breakdown phenomenon of material surface that is generated on the organic insulating material. The test method applied IEC publication 587. The result of the sample breakdown by tracking was carbonized and resistance of between the electrodes is approximately 300$\Omega$. In the result of DSC analysis, the caloric peak was detected before 100$^{\circ}C$ in product of tracking. It appeared weight loss of 10.87% at 537$^{\circ}C$ on TGA. IR spectrum analysis showed carbon-hydrogen(C-H)bond on molecular structure that is the sample of tracking.

  • PDF

Electric Safety Protection Device of High Speed for Incapable Operation of ELB and MCCB Using the Low Voltage Distribution Line (저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 고속형 전기안전 보호장치)

  • Kwak, Dong-Kurl;Jung, Do-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1925-1929
    • /
    • 2007
  • This paper is studied on a novel Electric Safety Protection Device (ESPD) of high speed for incapable operation of Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB) using the low voltage distribution line. The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is ELB and MCCB, of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a novel ESPD of high speed to trip of distribution line on electric arc or spark due to electrical fire. Some experimental results of the proposed ESPD are confirmed to the validity of the analytical results.

Analysis and Countermeasures for False-Tripping of Earth Leakage Breaker Due to Lightning Surge (누전차단기의 뇌써지 동작특성 분석 및 오동작 대책)

  • Lee, Jae-Bok;Myeong, Seong-Ho;Jo, Yeon-Gyu;Jang, Seok-Hun;Kim, Jeom-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.479-484
    • /
    • 2002
  • Recently it is reported that many a malfunction of ELB which is represented by non-operated type ELB for an impulse wave, is caused by lightning impulse and transient ground potential rise due to nearby lightning strokes. In order to examine the cause of malfunction, 5 samples were investigated experimentally in this study. As each ELB has a different leakage current detecting circuit and wiring method, various characteristics were measured. As a result, all of them brought about malfunctions under the lightning impulse voltage less than 7 kV and the surge current less than 3 kA. Also the different aspects were measured with a polarity of injected surge and a position of MOV to protect the inner circuit of ELB. The Position and effects of protecting devices were suggested as a remedy.

The New Residual Current Protective Devices Operating by Resistive Leakage Current (저항성 누전전류에 의하여 동작하는 새로운 누전차단기)

  • Ham, Seung-Jin;Hahn, Song-Yop;Koh, Chang-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.198-207
    • /
    • 2008
  • The conventional Residual Current Protective Devices(RCD, or earth leakage circuit breaker, ELB) operates depending on the total leakage current which is the vector-sum of resistive and capacitive components of a leakage current. However, the electric disaster such as electric shock or fire is mainly caused by the resistive component. Therefore, in this view point, the RCD is more realistic when it operates by the resistive component of the leakage current. In this paper, a new algorithm for measuring the resistive leakage current from the total leakage current is suggested, and is realized to an actual circuit. According to the suggested algorithm, the resistive component of the leakage current can be found by integrating the total leakage current over only a half cycle of the line voltage, and it is realized by using analog switches and resettable integrators. It is confirmed through experiments that the suggested algorithm detects, within maximum average error of 6.74%, the resistive leakage current from the total leakage current, and the RCD employing the suggested algorithm brakes the circuit within the regular interrupt time(30msec).

Dead Operation Characteristics of Earth Leakage Circuit Breaker Caused by Impulse Voltages (임펄스전압에 대한 누전차단기의 부동작 특성)

  • Lee, Bok-Hee;Chang, Sug-Hun;Lee, Seung-Chil
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1715-1717
    • /
    • 1997
  • This paper deals with the dead operation characteristics of the earth leakage circuit breaker(ELB) caused by impulse voltages. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of ELB due to the operation of surge protective devices, and the interruption of AC power lines brings about several disadvantages such as low reliability of electronic and informational systems, economical loss, and etc. The dead operation characteristics of the ELB from impulse voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a result, the peak current value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not cause dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELBs connected with the AC power lines having the surge protective devices bring about the dead operation.

  • PDF