• Title/Summary/Keyword: EFFECT OF FIRE

Search Result 1,360, Processing Time 0.032 seconds

환기량 조건이 열차 화재 성장에 미치는 영향성에 대한 FDS 화재 시뮬레이션 (Numerical study of the Effect of Ventilation Condition on Rolling Stock Fire Growth through the FDS Simulation)

  • 양성진;이창덕;오지은;강찬용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.124-132
    • /
    • 2010
  • To predict and analyze the rolling stock's fire growth is considered not only important factor in estimating hazard analysis of rolling stock, but also a primary factor in aspect of a rail load facility. Because it's could be regarded as a ignition source in risk assesment for the facility i.e. tunnel and station. However, currently, standardized method to predict and analyze the fire growth has not been completed yet. it is due to the fact that fire growth is not only depended on thermal property of interior materials, but also is affected dominantly by various factors such as ignition source (characterized by location, duration, and intensity), train running condition and in/exterior ventilation condition. Especially, ventilation condition is one of the most effective factor to affect fire growth in compartment space as noticed by under-ventilation fire condition. In this study, the effect of each ventilation condition on fire growth and load were examined through the numerical method through FDS (Fire Dynamics Simulator).

  • PDF

공동주택 화재 시 화재크기 및 실내 개구부 크기가 화재풍속에 미치는 영향에 관한 수치해석적 연구 (Numerical Study on the Effect of Heat Release Rate and Interior Opening on Fire Flow Velocity in the Case of Interior Fire in an Apartment Building)

  • 서찬원;신원규
    • 한국화재소방학회논문지
    • /
    • 제28권5호
    • /
    • pp.37-43
    • /
    • 2014
  • 재실자가 부속실로의 피난 시 부속실 송풍기가 작동하기 전단계에서는 실내화재로 인한 풍속이 발생하여 부속실 개방과 더불어 연소생성물이 부속실을 오염시켜 피난장애의 결과를 가져올 수 있다. 이로인한 화재크기 및 실내 개구부 크기가 화재풍속에 미치는 영향을 확인하기 수치해석 연구를 수행하였다. 수치해석에서는 화재크기 및 실내 개구부 크기를 달리하였고, 실제의 공동주택 형상과 치수를 반영하였다. 수치해석 결과, 화재크기별 실내의 개구부 크기에 따라서 중성대 높이가 변화하여 부속실로 흐르는 화재풍속 특성이 다르게 나타남을 확인할 후 있었다. 또한, 실내 중성대가 높은 곳에 형성된 경우에는 방화문 상 하부에서 화재풍속의 차이가 나타남을 확인할 수 있었다.

Development and Application of CFT without Fire Protection using High Performance Steel and Concrete

  • Hong, Seok-Beom;Kim, Woo-Jae;Park, Hee-Gon
    • 한국건축시공학회지
    • /
    • 제13권3호
    • /
    • pp.272-281
    • /
    • 2013
  • Concrete filled tube (CFT) columns, which consist of a steel tube filled with concrete, combine the benefits of the two materials. The steel tube provides a confining pressure to the concrete, while the local buckling of steel plate can be prevented by the concrete core. CFT columns also have a high fire resistance due to the heat storage effect of concrete under fire. For this reason, it is possible to develop CFT columns without fire protection measures. CFT columns without fire protection have many advantages, including quality control, cost reduction, better space efficiency and a shorter construction period. Due to these advantages, studies on the development of CFT columns without fire protection measures have been performed. However, CFT columns lose their bearing capacity under fire because the steel tube is exposed to the outside. As a result, the structure is collapsed, causing significant damage. In this research, we made a CFT column using high strength concrete (100 MPa) and high strength steel (800 MPa). We use steel fiber and nylon fiber with concrete to provide fire resistance. We perform the fresh concrete experiment and investigate the fire resistance of the CFT column (${\Box}400{\times}400{\times}15{\times}3000mm$) under loading. To investigate the effect of steel fiber on increasing fire resistance, we compare the fire resistance time according to the steel fiber. Through the test, it was found that the CFT specimen with steel fiber had better fire resistance performance than other cases.

물분무에 의한 화재제어 특성에 관한 연구 (A Study on the Fire Suppression Characteristics Using a Water Mist)

  • 김성찬;유홍선
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.261-267
    • /
    • 2003
  • The present study investigates the fire suppression characteristics using a water mist fire suppression system. Numerical simulations of fire suppression with water mist are performed with considering the interaction of fire plume and water droplet, droplet evaporation, and combustion of pool fire. The predicted temperature fields of smoke layer are compared with that of measured data. Numerical results agree with the experimental results within 5$^{\circ}C$ in the case without water mist In the case of fire suppression with water mist, numerical results dose not predict well lot temperature field in the gradual cooling region after water mist injection. But the predicted results of initial fire suppression are in good agreement with that of measured data. The reason of the discrepancy between predicted and measured data is due to the variation of turning rate during the injection of water mist. The effect of burning rate on the fire suppression is left as future study.

산불 전파의 수치 시뮬레이션 (Numerical Simulation of a Forest Fire Spread)

  • 이명성;원찬식;허남건
    • 설비공학논문집
    • /
    • 제20권2호
    • /
    • pp.137-143
    • /
    • 2008
  • In the present study, a forest fire spread was simulated with a three-dimensional, fully-transient, physics-based, computer simulation program. Physics-based fire simulation is based on the governing equations of fluid dynamics, combustion and heat transfer. The focus of the present study is to perform parametric study to simulate fire spread through flat and inclined wildland with vegetative fuels like trees or grass. The fire simulation was performed in the range of the wind speeds and degrees of inclination. From the results, the effect of the various parameters of the forest fire on the fire spread behavior was analyzed for the future use of the simulation in the prediction of fire behavior in the complex terrain.

주 변압기실 화재시나리오에 적용한 미세물분무 노즐의 소화성능 (Performance of Fire Extinguishing of Water Mist Nozzle for Power Transformer Fire Scenario)

  • 이경덕
    • 한국안전학회지
    • /
    • 제21권6호
    • /
    • pp.46-54
    • /
    • 2006
  • Fire extinguishing experiment was conducted with water mist nozzle in case of the pool fire, cascade fire and spray fire on flammable liquid of class B whether water mist system can be effective system for power transformer fire scenario. In the event of a pool fire, flow rate and time to extinguish was inclined to be increased according to the obstruction rate of ignition space. Furthermore, the performance of fire extinguishing depended upon the spraying angle of the nozzles. In case of cascade fire, the effect of extinguishment was began to show from a combustion pan filled with fuel and fuel flowing plate later on.

Numerical study on the post-earthquake fire behavior of intermediate steel moment frames

  • Parvizizadeh, Shayan;Kazemi, Mohammad Taghi
    • Earthquakes and Structures
    • /
    • 제22권2호
    • /
    • pp.137-145
    • /
    • 2022
  • As steel is highly sensitive to temperature variations, fire exposure is more destructive in the case of steel structures in comparison to the concrete ones. The performance of an intermediate three-story steel moment frame with 4 spans was studied under the service load, thermal load and post-earthquake fire in this paper. Also, the effects of passive fire-protection materials such as ordinary cement-based and fire-retardant coatings were investigated. To model and analyze the structure; Abaqus software is utilized. In order to apply the earthquake effect, the push-over analysis method is employed. Changes in the stories deflection, endurance time and growth of nonlinear regions due to losses in the steel stiffness and strength, are among the issues considered in this study. As an interesting finding, the beams protected by ordinary cement-based coating could sustain the fire exposure at least for 30 minutes in all cases. The mentioned time is increased by employing a new fire-retardant protection, which could prevent significant loss in the structure resistance against fire, even after 60 minutes of exposure to fire.

ESS 화재전용 소화약제 및 소화시스템 개발에 관한 연구 (A Study on the Development of Fire Extinguishing Agent and Extinguishing System for ESS Fire)

  • 이연호;이주형;김수진;전성호;최병철;오승주;김시국
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.147-155
    • /
    • 2020
  • 본 논문은 ESS 화재전용 소화약제 및 소화시스템 개발에 관한 연구이다. ESS 화재를 진압하기 위해 제작된 소화약제는 침윤제 타입으로 주된 소화효과인 냉각작용과 더불어 질식작용과 함께 표면장력 및 점도를 낮춘 침투성이 높은 소화약제로 ESS 모듈 내부의 배터리 셀까지 소화약제가 침투 가능한 특징이 있다. 소화시스템의 경우 랙 단위로 화재를 진압하는 국소방출방식으로 설계하였고, 소화효과를 극대화하기 위해 랙에 장착되는 일반형 노즐과 ESS 모듈 후면 홀에 삽입하는 360° 회전형 노즐을 제작하고, 가스방출압력에 의해 소화약제가 강하게 방사되도록 하였다. ESS 모듈 1단위 및 모듈 3단위 화재진압성능 실험결과 소화약제 방사 후 각각 8 s 및 9 s 만에 눈에 보이는 화염이 모두 소멸되었다. 또한, 소화약제 방사종료 후 600 s 동안 재발화 여부를 확인한 결과 모든 화재진압성능 실험에서 재발화가 일어나지 않고 ESS 화재가 완벽히 진압되는 것을 확인할 수 있었다.

중복도형 인텔리전트빌딩 화재시 연기제어를 통한 피난안전성 확보에 관한 연구 (A Study on Securing Safety of Evacuation through Smoke Control in Case of Fire at the Central Corridor Type Intelligent Buildings)

  • 민세홍;이재문;배연준
    • 대한안전경영과학회지
    • /
    • 제17권2호
    • /
    • pp.117-127
    • /
    • 2015
  • This study investigated the smoke blocking and control systems for the safety of residents evacuation and for the prevention of smoke spread through the central corridor in the event of central corridor type of intelligent building fire. We offered additional ways of utilizing smoke ventilators and intake ventilation equipment and utilized CFD-based fire simulation program(FDS Ver.5.5.3) in order to analyze the effect. As a result, many differences in the smoke block effect, depending on the application of smoke ventilator and location of installation, was found. In addition, the result was found that larger effect was showed not in the case of application of smoke ventilator in central corridor only but application in fire room. The reason is that the smoke leakage is blocked primarily as air is flowed in the fire room through open door by operation of intake smoke ventilator in the public corridor and secondarily, the smoke leakage to the public corridor could be blocked as fire and smoke were released to the opened smoke ventilator continuously. Especially, the effect was maximized through complex interactions by applying smoke ventilator and intake ventilation equipment in corridor together rather than applying smoke ventilator and intake ventilation equipment independently. The proposed measure through this study shall be considered from architectural plan as one of ways for blocking from smoke spread to the central corridor in the central corridor type of intelligent building. In addition, flaws on regulation shall be established and supplemented.

초고층 건축물에서 급기가압제연이 연돌효과에 미치는 영향 (The Influence on the Stack effect that Pressure differential system to smoke control in High-rise buildings)

  • 임채현;박용환
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.235-238
    • /
    • 2008
  • High-rise buildings with stack effect caused by the foreclosure, which significantly delayed the spread of a fire in effects of these stack effect driving force said. In this research on the stack effect of the lobby if the pressurization of the stairwell analysis of the pressure distribution of the CONTAMW. Overall, the pressurization of the lobby makes it stairwell amount of pressure(+) to the zone in pressure designed to prevent the spread of smoke control performance and found that, the way a normal state and sub-pressurization in the stairwell with stack effect of the turbulence Such as the formation of the upper flow, but, in the upper atmosphere with pressurization was formed by the underlying trend.

  • PDF