• 제목/요약/키워드: EEG processor

검색결과 8건 처리시간 0.015초

A 95% accurate EEG-connectome Processor for a Mental Health Monitoring System

  • Kim, Hyunki;Song, Kiseok;Roh, Taehwan;Yoo, Hoi-Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권4호
    • /
    • pp.436-442
    • /
    • 2016
  • An electroencephalogram (EEG)-connectome processor to monitor and diagnose mental health is proposed. From 19-channel EEG signals, the proposed processor determines whether the mental state is healthy or unhealthy by extracting significant features from EEG signals and classifying them. Connectome approach is adopted for the best diagnosis accuracy, and synchronization likelihood (SL) is chosen as the connectome feature. Before computing SL, reconstruction optimizer (ReOpt) block compensates some parameters, resulting in improved accuracy. During SL calculation, a sparse matrix inscription (SMI) scheme is proposed to reduce the memory size to 1/24. From the calculated SL information, a small world feature extractor (SWFE) reduces the memory size to 1/29. Finally, using SLs or small word features, radial basis function (RBF) kernel-based support vector machine (SVM) diagnoses user's mental health condition. For RBF kernels, look-up-tables (LUTs) are used to replace the floating-point operations, decreasing the required operation by 54%. Consequently, The EEG-connectome processor improves the diagnosis accuracy from 89% to 95% in Alzheimer's disease case. The proposed processor occupies $3.8mm^2$ and consumes 1.71 mW with $0.18{\mu}m$ CMOS technology.

뇌전기파 분석용 FFT 프로세서 설계 (A design of FFT processor for EEG signal analysis)

  • 김은숙;신경욱
    • 한국정보통신학회논문지
    • /
    • 제14권11호
    • /
    • pp.2548-2554
    • /
    • 2010
  • 본 논문에서는 의료 서비스를 위한 뇌전기파(EEG: electroencephalogram) 신호 분석용 FFT(Fast Fourier Transform) 프로세서를 구현하였다. 실시간으로 발생하는 EEG 신호를 블록으로 나누어 short-time FFT 처리하기 위해 Hamming 창 함수를 사용하였으며, 이로 인해 감소되는 양끝의 값은 1/2 오버랩 시켜 보완하였다. 0~100 [Hz] 사이의 주파수 특성을 갖는 뇌전기파의 효율적인 대역 분석을 위해 256-point FFF 프로세서를 radix-4 알고리듬을 적용하여 구현하였으며, 단일 메모리 뱅크 구조를 사용하여 집적도를 높였다. 설계된 FFT 프로세서는 FPGA 구현을 통해 가능을 검증하였으며, 연산오차가 2% 이내로 높은 연산 정밀도를 갖는다.

뇌전기파 분석용 FFT 프로세서 설계 (A design of FFT processor for EEG signal analysis)

  • 김은숙;김해주;나영헌;신경욱
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.88-91
    • /
    • 2010
  • 본 논문에서는 의료 서비스를 위한 뇌전기파(EEG : electroencephalogram) 신호 분석용 FFT(Fast Fourier Transform) 프로세서를 구현하였다. 실시간으로 발생하는 긴 신호를 short-time FFT 처리하기 위해 Hamming 창 함수를 사용하였으며, 이로 인해 감소되는 양끝의 값은 1/2 오버랩 시켜주어 보완하였다. 0~100[Hz] 사이의 주파수 특성을 가지는 뇌전기파의 효율적인 대역 분석을 위해 256-point FFT 프로세서를 radix-4 알고리듬을 적용하여 구현하였고, 단일 메모리 뱅크 구조를 사용하여 집적도를 높였다. 설계된 FFT 프로세서는 연산오차가 3% 이내로 높은 연산 정밀도를 갖는다.

  • PDF

아날로그 뇌파기를 응용한 간단한 디지털 뇌파 시스템 (Simple Digital EEG System Utilizing Analog EEG Machine)

  • 정기영;김재문;정만재
    • Annals of Clinical Neurophysiology
    • /
    • 제2권1호
    • /
    • pp.8-12
    • /
    • 2000
  • Purpose : The rapid development and wide popularity of Digital EEG(DEEG) is due to its convenience, accuracy and applicability for quantitative analysis. These advantages of DEEG make one hesitate to use analog EEG(AEEG). To assess the advantage of DEEG system utilizing AEEG(DAEEG) over conventional AEEG and the clinical applicability, a DAEEG system was developed and applied to animal model Methods : Sprague-Dawley rat as status epilepticus model were used for collecting the EEG data. After four epidural electrodes were inserted and connected to 8-channel analog EEG(Nihon-Kohden, Japan), continous. EEG monitoring via computer screen was done from two rats simultaneously. EEG signals through analog amplifier and filters were digitized at digital signal processor and stored in Windows-based pentium personal computer. Digital data were sampled at a rate of 200 Hz and 12 bit of resolution. Acquisition software was able to carry out 'real-time view, sensitivity control and event marking' during continuous EEG monitoring. Digital data were stored on hard disk and hacked-up on CD-ROM for off-line review. Review system consisted of off-line review, saving and printing out interesting segment and annotation function. Results: This DAEEG system could utilize most major functions of DEEG sufficiently while making a use of an AEEG. It was easy to monitor continuously compared to Conventional AEEG and to control sensitivity during ictal period. Marking the event such as a clinical seizure or drug injection was less favorable than AEEG due to slowed processing speed of digital processor and central processing unit. Reviewing EEG data was convenient, but paging speed was slow. Storage and management of data was handy and economical. Conclusion : Relatively simple digital EEG system utilizing AEEG can be set-up at n laboratory level. It may be possible to make an application for clinical purposes.

  • PDF

실시간 뇌파분석에 관한 연구 (A Study on the Real-time Electroencephalography analysis)

  • 송재성;유선국;김선호;김남현;김기만;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.278-281
    • /
    • 1995
  • In this paper, we have developed EEG (electroencephalography) analyzer for monitoring the condition of brain in neurological surgery. This system is composed of EEG amplifier. personal-computer and BSP (Digital Signal Processor). By parallel processing of DSP, this system can analysis the power spectral density change of EEG in real-time and display the CSA(Compressed Spectral Array) and CDSA(Color Density Spectral array) of EEG. This system was tested by real EEG and showed the change of EEG.

  • PDF

디지털 뇌파 전송 프로토콜 개발 및 검증 (Development and Verification of Digital EEG Signal Transmission Protocol)

  • 김도훈;황규성
    • 한국통신학회논문지
    • /
    • 제38C권7호
    • /
    • pp.623-629
    • /
    • 2013
  • 본 논문에서는 뇌파 전송 프로토콜 설계하고 이를 검증할 테스트 플랫폼 제작 결과를 소개한다. 건식 전극에서 검출된 뇌파는 인접한 ADC(analog-to-digital converter)를 거쳐 디지털 신호로 변환되고, 각 센서 노드에서 디지털 신호로 변환된 뇌파는 $I^2C$(inter-integrated circuit) 프로토콜을 통해서 DSP(digital signal processor) 플랫폼으로 전송된다. DSP 플랫폼에서는 뇌파 전처리 알고리즘 수행 및 뇌 특성 벡터 추출 등의 기능을 수행한다. 본 연구에서는 각 채널당 10비트 또는 12비트 ADC를 사용하여 최대 16채널의 데이터를 전송하기 위하여 $I^2C$ 프로토콜을 적용하였다. 실험결과 4바이트 데이터 버스트전송을 수행하면 통신오버헤드가 2.16배로 측정이 되어 10 비트 또는 12 비트 1 ksps ADC를 16채널로 사용시 총 데이터전송율이 각각 345.6 kbps, 414.72 kbps 로 확인되었다. 따라서 400 kbps 고속전송모드 $I^2C$를 사용할 경우 ADC 비트에 따라서 슬레이브와 마스터의 채널비가 각각 16:1, $(8:1){\times}2$ 로 되어야 한다.

BCI 시스템 구현을 위한 모델링 (Modeling for Implementation of a BCI System)

  • 김미혜;송영준
    • 한국콘텐츠학회논문지
    • /
    • 제7권8호
    • /
    • pp.41-49
    • /
    • 2007
  • BCI시스템은 뇌 자체에서 발생하는 전기적인 신호를 측정하여 콘트롤 또는 통신 시스템에 접목시키는 것이다. 이 시스템은 뇌파의 움직임을 실시간으로 검출하고 이를 통해 발생된 신호를 사용하여 전자장비 또는 소프트웨어에 바탕을 둔 프로세서 등을 조정할 수 있다. 본 논문에서는 다양한 정신 상태에서 발생한 뇌전위 신호를 분석하고 인식하는 뇌-컴퓨터간 인터페이스 시스템을 개발할 때 뇌파 측정시 혼합되는 잡음제거 및 분리에 관한 것을 다루고자 한다. BCI시스템 구현을 위한 뇌파 분류과정에서 이분법의 수리적 모델을 사용하여 뇌파를 분류하고 잡음구간을 추출하는 방법을 제안하였다.

A Biosignal-Based Human Interface Controlling a Power-Wheelchair for People with Motor Disabilities

  • Kim, Ki-Hong;Kim, Hong-Kee;Kim, Jong-Sung;Son, Wook-Ho;Lee, Soo-Young
    • ETRI Journal
    • /
    • 제28권1호
    • /
    • pp.111-114
    • /
    • 2006
  • An alternative human interface enabling people with severe motor disabilities to control an assistive system is presented. Since this interface relies on the biosignals originating from the contraction of muscles on the face during particular movements, even individuals with a paralyzed limb can use it with ease. For real-world application, a dedicated hardware module employing a general-purpose digital signal processor was implemented and its validity tested on an electrically powered wheelchair. Furthermore, an additional attempt to reduce error rates to a minimum for stable operation was also made based on the entropy information inherent in the signals during the classification phase. In the experiments, most of the five participating subjects could control the target system at their own will, and thus it is found that the proposed interface can be considered a potential alternative for the interaction of the severely disabled with electronic systems.

  • PDF