• 제목/요약/키워드: EEG Channel Comparison

검색결과 18건 처리시간 0.027초

최소 제곱 가속 기반의 적응 디지털 필터를 이용한 두피 뇌전도에서의 심전도 잡음 추정 및 제거 (A Method for Estimation and Elimination of EGG Artifacts from Scalp EEG Using the Least Squares Acceleration Based Adaptive Digital Filter)

  • 조성필;송미혜;박호동;이경중
    • 전기학회논문지
    • /
    • 제56권7호
    • /
    • pp.1331-1338
    • /
    • 2007
  • A new method for detecting and eliminating the Electrocardiogram(ECG) artifact from the scalp Electroencephalogram(EEG) is proposed. Based on the single channel EEG, the proposed method consists of 4 procedures: emphasizing the R-wave of ECG artifact from EEG using the least squares acceleration(LSA) filter, detecting the R-wave from the LSA filtered EEG using the phase space method and R-R interval, generating the delayed impulse synchronized to the R-wave and elimination of the ECG artifacts based on the adaptive digital filter using the impulse and raw EEG. The performance of the proposed method was evaluated in the two separating parts of R-wave detection and, ECG estimation and elimination from EEG. In the R-wave detection, the proposed method showed the mean error rate of 6.285(%). In the ECG estimation and elimination using simulated and/or real EEG recordings, we found that the ECG artifacts were successfully estimated and eliminated in comparison with the conventional multi-channel techniques, in which independent component analysis and ensemble average method are used. From this we can conclude that the proposed method is useful for the detecting and eliminating the ECG artifact from single channel EEG and simple for ambulatory/portable EEG monitoring system.

단일 채널 두피 뇌전도에서의 심전도 잡음 추정 및 제거 (Estimation and Elimination of ECG Artifacts from Single Channel Scalp EEG)

  • 조성필;송미혜;박호동;이경중;박영철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1910-1911
    • /
    • 2007
  • A new method for estimating and eliminating electrocardiogram (ECG) artifacts from single channel scalp electroencephalogram (EEG) is proposed. The proposed method consists of emphasis of QRS complex from EEG using least squares acceleration (LSA) filter, generation of synchronized pulse with R-peak and ECG artifacts estimation and elimination using adaptive filter. The performance of the proposed method was evaluated using simulated and real EEG recordings, we found that the ECG artifacts were successfully estimated and eliminated in comparison with the conventional multi-channel techniques, which are independent component analysis (ICA) and ensemble average (EA) method. In conclusion, we can conclude that the proposed method is useful for the detecting and eliminating the ECG artifacts from single channel EEG and simple to use for ambulatory/portable EEG monitoring system.

  • PDF

뇌파 채널 개수 변화에 따른 수면단계 분석 비교 (Comparative Analysis of Sleep Stage according to Number of EEG Channels)

  • 한혜경;이병문
    • 한국콘텐츠학회논문지
    • /
    • 제21권2호
    • /
    • pp.140-147
    • /
    • 2021
  • 다양한 수면검사에서 수면단계를 정확히 판단하기 위해 뇌파를 측정한다. 일반적으로 측정은 센서 채널의 개수가 늘어날수록 정확도가 높아지지만, 뇌파는 측정할 때 피부에 전극을 부착하여 수면을 방해하는 요소로 작용한다. 일상생활에서 자가 수면케어를 할 때는 사용자의 불편함과 측정데이터의 정확도를 모두 고려한 최소한의 뇌파 채널 개수를 선택할 필요가 있다. 따라서 본 논문에서는 1개의 채널부터 4개의 채널에 대한 수면단계 분석 모델을 제작하여 1채널은 82.28%, 2채널은 85.77%, 3채널은 80.33%, 4채널은 68.87%의 정확도를 확인했다. 본 연구 결과는 측정 부위가 제한적이라는 한계가 있지만, 채널 개수에 따른 정확도를 비교하여 뇌파 기반 수면분석에서 채널 개수 선정에 대한 정보를 제공한다.

Design of a Low-cost Active Dry Electrode Module for Single Channel EEG Recording

  • Byeon Jong-Gil;Jin Kyung-Soo;Park Byoung-Woo
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권1호
    • /
    • pp.49-54
    • /
    • 2005
  • This paper presents a design of 1-channel active dry electrode module for EEG from one's forehead. The IA(instrumentation amplifier) circuit inside the module is based on the configuration sown on the paper MettingVanRijn et al. We analyze the IA circuit to find out the related equation, and then compare its simulated characteristic with the result obtained from the real active dry electrode circuit. With the active dry electrode and the wet(Ag/AgCI) electrode connected to the separated analog processing module on one's forehead at the same time, their real time and FFT outputs of EEG are examined for comparison. The active dry electrode module has advantages over the wet electrode and its analog processing module: 1) The size of the analog processing circuit of the active dry electrode module is smaller than that of existing EEG analog processing module; 2) the total cost required to make the proposed analog processing circuit is much lower than that of the existing circuit, since the designed circuit needs smaller parts; 3) the electrical characteristic is comparable to the general EEG analog processing module even if the designed module has simpler circuit configuration.

2채널 뇌기능 감시 시스템을 위한 뇌파 소프트웨어의 개발 (Development of an EEG Software for Two-Channel Cerebral Function Monitoring System)

  • 김동준;유선국;김선호
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권1호
    • /
    • pp.81-90
    • /
    • 1999
  • 본 연구에서는 수술이나 환자 모니터링시 무의식 상태 환자의 뇌혈류량에 대한 정확한 모니터링으로 뇌허혈 현상을 방지하기 위하여 2채널 양극성 아날로그 EEG를 디지털로 처리하여 다양한 뇌파 관련 파라미터를 추출하여 실시간으로 한 화면에 디스플레이하고, 또한 임상의사들이 사용하기 편리한 뇌파 감시 소프트웨어를 개발하고자 하였다. 이를 위하여 EEG-데이터를 FFT 연산 후 CSA 및 DSA의 형태로 표현하며, 기타 다양한 뇌파관련 파라미터를 추출한 후 한 화면에서 실시간으로 디스플레이하고, 사용 편리성도 극대화하도록 프로그램하였다. 프로그램은 개발 도중에 여러 번의 동물실험 및 임상실험을 통하여 개선 보완되었으며, EEG, CSA, DSA 및 알파비, 퍼센트 델타 스펙트럼 모서리 주파수, 전체 파워, 전체 파워의 차 등의 주요 뇌파 파라미터들을 한 화면에서 관찰하게 되어 환자 상태의 종합적인 간찰이 가능하며, 나중에 저장된 EEG 파일을 재검토할 수 있다. 또한 CSA, DSA, 스펙트럼 모서리 주파수 및 전체 파워는 원하는 부분에서 표본을 취해 화면 위쪽에 최대 3개까지 붙여 놓고 동시에 비교할 수 있으므로 환자 상태의 객관적인 비교가 가능하고, 환자상태, 응급처치 등에 대한 기록사항을 입력할 수 있어서 저장된 EEG 파일의 검토시 이들 event로 즉시 찾아가는 기능이 있으며, 그 외에도 앞 뒤 점프 이동 기능, 이득 조절 기능, 윈도우 환경에서의 파일관리 기능 등을 갖추고 있고, 프로그램이 윈도우 환경에서 개발되어 마우스에 의해 대부분의 동작이 이루어진다. 개발된 프로그램을 이용한 대학병원의 임상실험결과, 환자상태의 변화에 매우 민감하게 반응하고, 또한 임상의사들이 이용하기에도 매우 편리하다는 평가를 받았다.

  • PDF

내관 전침 자극이 뇌파의 상관 차원에 미치는 영향 - 정보전달 모드도해 분석법을 중심으로 - (The Effect of Electroacupuncture at the PC6 (Naegwan) on the correlation dimension of EEG)

  • 홍승원;황배연;이상룡
    • Korean Journal of Acupuncture
    • /
    • 제20권3호
    • /
    • pp.49-60
    • /
    • 2003
  • The aim of this study was to examine the effects of electroacupuncture(EA) at the PC6 (Naegwan) on normal humans using KarhunenLoeve decomposition method. Electroencephalogram(EEG) is a multi-scaled signal consisting of several components of time series with different dominant frequency ranges and different origins. EEG KarhunenLoeve decomposition method exibit site-specific and state-related differences in specific frequency bands. In this study, KarhunenLoeve decomposition method was used as a measure(D2) of complexity. 30 channel EEG study was carried out in 10 subjects (10 males; $age=21.4{\pm}0.5$ years). Results : We found that the average values and standard deviations of D2 at FP1, FP2, FTC1, FTC2, TT1, TT2, T4, TCP1, P3, P4, T6, OZ channel (p<0.05) were higher than during the acupuncture treatment, and the average values and standard deviations of D2 at F3, F8 channels(p<0.05) were lowered than during the acupuncture treatment. However, the comparison with that before and after the treatment shows no significant differences in all channels.

  • PDF

뉴로피드백 효과에 따른 EEG 기반 BCI 동작 상상 성능 평가 요소별 정확도 비교 (Accuracy Comparison of Motor Imagery Performance Evaluation Factors Using EEG Based Brain Computer Interface by Neurofeedback Effectiveness)

  • 최동학;류연수;이영범;민세동;이명호
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권4호
    • /
    • pp.295-304
    • /
    • 2011
  • In this study, we evaluated the EEG based BCI algorithm using common spatial pattern to find realistic applicability using neurofeedback EEG based BCI algorithm - EEG mode, feature vector calculation, the number of selected channels, 3 types of classifier, window size is evaluated for 10 subjects. The experimental results have been evaluated depending on conditioned experiment whether neurofeedback is used or not In case of using neurofeedback, a few subjects presented exceptional but general tendency presented the performance improvement Through this study, we found a motivation of development for the specific classifier based BCI system and the assessment evaluation system. We proposed a need for an optimized algorithm applicable to the robust motor imagery evaluation system with more useful functionalities.

Spatial Focalization of Zen-Meditation Brain Based on EEG

  • Liu, Chuan-Yi;Lo, Pei-Chen
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권1호
    • /
    • pp.17-24
    • /
    • 2008
  • The aim of this paper is to report our preliminary results of investigating the spatial focalization of Zen-meditation EEG (electroencephalograph) in alpha band (8-13 Hz). For comparison, the study involved two groups of subjects, practitioners (experimental group) and non-practitioners (control group). To extract EEG alpha rhythm, wavelet analysis was applied to multi-channel EEG signals. Normalized alpha-power vectors were then constructed from spatial distribution of alpha powers, that were classified by Fuzzy C-means based algorithm to explore various brain spatial characteristics during meditation (or, at rest). Optimal number of clusters was determined by correlation coefficients of the membership-value vectors of each cluster center. Our results show that, in the experimental group, the incidence of frontal alpha activity varied in accordance with the meditation stage. The results demonstrated three different spatiotemporal modules consisting with three distinctive meditation stages normally recognized by meditation practitioners. The frontal alpha activity in two groups decreased in different ways. Particularly, monotonic decline was observed in the control group, and the experimental group showed increasing results. The phenomenon might imply various mechanisms employed by meditation and relaxation in modulating parietal alpha.

내관 전침 자극이 뇌파에 미치는 영향 (The Effect of Electroacupuncture at the PC6 (Naegwan) on the EEG)

  • 이태영;김영안;이광규;육상원;이창현;이상룡
    • Journal of Acupuncture Research
    • /
    • 제19권3호
    • /
    • pp.26-40
    • /
    • 2002
  • Objective : The aim of this study was to examine the effects of electroacupuncture(EA) at the PC6 (Naegwan) on nomal humans using power spectrum analysis. Methods : Electroencephalogram(EEG) is a multi-scaled signal consisting of several components of time series with different dominant frequency ranges and different origins. EEG power spectrum exibit site-specific and state-related differences in specific frequency bands. In this study, power spectrum was used as a measure of complexity. 30 channel EEG study was carried out in 8 subjects (8 males; age=$21.4{\pm}0.5$ years). Results : We found that the power values of the alpha wave at F7 channel (P<0.05) were highered than during the acupuncture treatment, and the power values of the delta wave at TCP1, CP1, TCP2, T5 channels(P<0.05) were lowered than during the acupuncture treatment. However, the comparison with that before and after the treatment shows no significant differences in all channels.

  • PDF

신맥 조해의 전침자극이 치매환자의 뇌파에 미치는 영향 (The Immediate Effect of Electroacupuncture at the B62(Shinmaek) K6(Chohae) on the EEG of Vascular Dementia)

  • 박우순;이태영;김수용;이광규;육상원;이창현;이상룡
    • Journal of Acupuncture Research
    • /
    • 제18권2호
    • /
    • pp.67-78
    • /
    • 2001
  • The aim of this study was to examine the effects of low frequency electroacupuncture(EA) at the $B_{62}$ (Shinmaek) $K_6$(Chohae) on vascular dementia in humans using nonlinear dynamics. Electroencephalogram(EEG) is a multi-scaled signal consisting of several components of time series with different dominant frequency ranges and different origins. Nonlinear measures of the EEG like the correlation dimension ($D_2$) and the first positive Lyapunov exponent ($L_1$) reflect the complexity of the EEG. In this study, $D_2$ was used as a measure of complexity. Sixteen channel EEG study was carried out in six subjects (5 females and 1 males; $age=83.83{\pm}7.19years$). We found that the baseline $D_2$ values of the EEG at F4 and F8 channels (P<0.01) were lowered than during the acupuncture treatment, indicating decreased complexity of the EEG. However, the comparison with that before and after the treatment shows no significant differences in all channels.

  • PDF