• Title/Summary/Keyword: EDGE 검출기

Search Result 177, Processing Time 0.026 seconds

High-Sensitivity Microstrip Patch Sensor Antenna for Detecting Concentration of Ethanol-Water Solution in Microliter Volume (마이크로리터 부피의 에탄올 수용액 농도 검출을 위한 고감도 마이크로스트립 패치 센서 안테나)

  • Junho Yeo;Jong-Ig Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.6
    • /
    • pp.510-515
    • /
    • 2022
  • In this paper, a microstrip patch sensor antenna (MPSA) for detecting the concentration of an ethanol-water solution in a microliter volume is proposed. A rectangular slot was added at the radiating edge of the patch to increase the sensitivity to the relative permittivity change. To improve a low input resistance caused by placing an ethanol-water solution, which is a polar liquid with high dielectric constant and high loss tangent, on the patch, a quarter-wave impedance transformer was added between the 50-ohm feedline and the patch, and the MPSA was fabricated on a 0.76 mm-thick RF-35 substrate. A cylindrical container was made of acryl, and 15 microliters of the ethanol-water solution was tested from 0% to 100% of ethanol concentration at 20% intervals. Experiment results show that the resonant frequency increased from 1.947 GHz to 2.509 GHz when the ethanol concentration of the ethanol-water solution was increased from 0% to 100%, demonstrating the performance as a concentration detecting sensor.

Evaluation of Dosimetric Characteristics of a Double-focused Dynamic Micro-Multileaf Collimator (DMLC) (이중으로 집중된 동적 미세 다엽콜리메이터의 선량학적 특성 평가)

  • Kim, Ae Ran;Seo, Jae-Hyuk;Shin, Hun-Joo;Park, Hyeong Wook;Lee, Ki Woong;Lee, Jae Choon;Kim, Shin-Wook;Kim, Ji Na;Park, Hyeli;Lee, Heui-Kwan;Kang, Young-Nam
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.223-228
    • /
    • 2015
  • Double-focused micro-Multileaf Collimator (${\mu}MLC$) is able to create radiation fields having sharper dose gradients at the field edges than common MLC. Therefore, ${\mu}MLC$ has been used for the stereotactic radiosurgery (SRS) and Stereotactic Radiotherapy (SRT). We evaluated the dosimetric characteristics of a doublefocused Dynamic-${\mu}MLC$ (DMLC) attached to the Elekta Synergy linear accelerator. For this study, the dosimetric parameters including, Percent Depth Dose (PDD), Leaf leakage and penumbra, have been measured by using of the radiochromic films (GafChromic EBT2), EDGE diode detector and three-dimensional water phantom. All datas were measured on 6 MV x-ray. As a result, The DMLC shows transmission below to 1% and because of double-focused construction of the DMLC, the penumbras of fields with DMLC are independent from the field sizes. In this paper, the resulting dosimetric evaluations proved the applicability of the DMLC attached to the Elekta Synergy linear accelerator.

A Study on the Resolution Analysis of Digital X-ray Images with increasing Thickness of PMMA (조직 등가물질 두께 증가에 따른 디지털 엑스선 영상의 해상도 분석에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.173-179
    • /
    • 2021
  • Scattered x-ray generated by digital radiography systems also have the advantage of increasing signals, but ultimately detectability is reduced by decreasing resolution and increasing noise of x-ray images transmitted objects. An indirect method of measuring scattered x-ray in a modulation-transfer function (MTF) for evaluating resolution in a spatial-frequency domain can be considered as a drop in the MTF value corresponding to zero-frequency. In this study, polymethyl methacrylate (PMMA) was used as a patient tissue equivalent, and MTFs were obtained for various thicknesses to quantify the effect of scattered x-ray on resolution. X-ray image signals were observed to decrease by 35 ~ 83% with PMMA thickness increasing, which is determined by the absorption or scattering of x-rays in PMMA, resulting in reduced MTF and increased scatter fraction. The method to compensate for MTF degradation by PMMA resulted in the MTF inflation without considering the optical spreading generated by the indirect-conversion type detector. Data fitting or zero-padding are needed to compensate for MTF more reasonably on edge-spread function or line-spread function.

Peripheral Dose Distributions of Clinical Photon Beams (광자선에 의한 민조사면 경계영역의 선량분포)

  • 김진기;김정수;권형철
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.71-77
    • /
    • 2001
  • The region, near the edge of a radiation beam, where the dose changes rapidly according to the distance from the beam axis is known as the penumbra. There is a sharp dose gradient zone even in megavoltage photon beams due to source size, collimator, lead alloy block, other accessories, and internal scatter ray. We investigate dosimetric characteristics on penumbra regions of a standard collimator and compare to those of theoritical model for the optimal use of the system in radiotherapy. Peripheral dose distribution of 6 W Photon beams represents penumbral forming function as the depth. Also we have discussed that the peripheral dose distribution of clinical photon beams, differences between calculation dose use of emperical penumbral forming function and measurements in penumbral region. Predictions by emperical penumbral forming functions are compared with measurements in 3-dimensional water phantom and it is shown that the method is capable of reproduceing the measured peripheral dose values usually to within the statistical uncertainties of the data. The semiconductor detector and ion chamber were positioned at a dmax depth, 5cm depth, 10cm depth, and its specific ratio was determined using a scanning data. The effective penumbra, the distance from 80% to 20% isodose lines were analyzed as a function of the distance. The extent of penumbra will also expand with depth increase. Difference of measurement value and model functions value according to character of the detector show small error in dose distribution of the peripheral dose.

  • PDF

Imaging Study of Fine Pixel Scintillator Block using Reflector on the Side of Light Guide (광가이드 측면 반사체 사용을 통한 미세 픽셀 섬광체 블록의 영상화 연구)

  • Seung-Jae Lee;Byungdu Jo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.671-677
    • /
    • 2023
  • When a scintillator block is constructed using fine scintillator pixels, the scintillator block located at the edge of the scintillator block results in overlapping images. To solve this problem, a light guide was inserted between the scintillator block and the photosensor, and images of all scintillation pixels were separated and acquired. However, loss of light may occur through the light guide, which eventually affects the quality of the image due to a decrease in energy resolution. Therefore, in this study, a detector was designed that can separate scintilltion pixels better by using a reflector on the side of the light guide and can secre excellent energy resolution by minimizing light loss. For comparative evaluation with previous studies, flood images were obtained through DETECT2000 capable of light simulation, and the degree of separation and light collection rate were evaluated. When a reflector was used on the side of the light guide, all materials showed excellent separation regardless of the material of the light guide, which showed better separation results than previous studies. In addition, the light collection rate was more that five times better when the reflector was applied than when it wa not. If this detector is applied to a small animal positron emission tomography, it will be possilbe to secre excellent image quality through excellent spatial resolution and energy resolution.

An Implementation of the $5\times5$ CNN Hardware and the Pre.Post Processor ($5\times5$ CNN 하드웨어 및 전.후 처리기 구현)

  • Kim Seung-Soo;Jeon Heung-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.5
    • /
    • pp.865-870
    • /
    • 2006
  • The cellular neural networks have shown a vast computing power for the image processing in spite of the simplicity of its structure. However, it is impossible to implement the CNN hardware which would require the same enormous amount of cells as that of the pixels involved in the practical large image. In this parer, the $5\times5$ CNN hardware and the pre post processor which can be used for processing the real large image with a time-multiplexing scheme are implemented. The implemented $5\times5$ CNN hardware and pre post processor is applied to the edge detection of $256\times256$ lena image to evaluate the performance. The total number of block. By the time-multiplexing process is about 4,000 blocks and to control pulses are needed to perform the pipelined operation or the each block. By the experimental resorts, the implemented $5\times5$ CNN hardware and pre post processor can be used to the real large image processing.

Investigation on The Cause of Interception of Regulated Pest from Imported Glue-laminated Boards Through In-situ Inspection of Their Manufacturing Processes (생산공정 현장실사를 통한 수입 집성재로부터 규제해충 검출 원인 조사)

  • Kim, Min-Ji;Shin, Hyun-Kyeong;Choi, Yong-Seok;Salim, Sabiha;Kim, Gyu-Hyeok
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.617-621
    • /
    • 2016
  • On-site survey on glue-laminated board (GLB) manufacturers of Malaysia, Indonesia, and China was conducted to identify the cause of interception of regulated pest from imported GLBs from those countries, and to suggest optimal manufacturing processes of GLB for preventing quarantine risk associated with imported GLBs. The cause of pest interception was improper manufacturing processes, such as air drying or inadequate kiln drying of green laminae, improper storage of dried laminae before finger jointing and edge gluing, and/or incomplete packing of GLBs. In particular, Paulownia GLB manufacturing processes used in China, including air drying of laminae, were mostly poor in terms of preventing quarantine risk associated with imported GLBs. From now on, for preventing quarantine risk associated with imported GLBs, importers have to ask foreign manufacturers spontaneously to use proper manufacturing processes (adequate kiln drying of green laminae, proper storage of dried laminae, and complete packaging of final GLBs).

A Study on the Attenuation of Surface Acoustic Waves by Optical Measurement Method (광학적 측정방법에 의한 표면 탄성파의 감쇠에 관한 연구)

  • You, I.H.;Kim, D.I.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.4
    • /
    • pp.237-243
    • /
    • 1995
  • We have studied methods of detecting attenuation of solid materials such as silicon wafer and piezoelectric $LiTaO_3$ by means of optical probing techniques. We have performed measurements of surface acoustic waves(SAW) generated from 90 degree wedge type transducer and also from inter-digital transducers(IDT). SAW of 20.0 MHz was generated on a silicon wafer from the 90 degree wedge type transducer and those of 20.8 and 14.5 MHz are generated on a $LiTaO_3$ from the IDT. Then any surface-corrugation resulted from the above SAW was investigated by He-Ne laser beams. We projected laser beams, which were modulated by an optical chopper, on the SAW of the same frequency and then measured the scattered beam by the lock-in amplifier. We modulated and synchronized both SAW and the incident laser beam as well as the phase sensitive detector(PSD) to the same frequency in order to simplify our measurement system. We obtained the attenuation coefficients of SAW to be $0.62{\sim}0.75dB/mm$(from IDT1, 20.8 MHz), and $0.60{\sim}0.72dB/mm$(from IDT2, 14.5 MHz), $0.83{\sim}1.28dB/mm$(from the wedge type), respectively.

  • PDF

Medical Image Automatic Annotation Using Multi-class SVM and Annotation Code Array (다중 클래스 SVM과 주석 코드 배열을 이용한 의료 영상 자동 주석 생성)

  • Park, Ki-Hee;Ko, Byoung-Chul;Nam, Jae-Yeal
    • The KIPS Transactions:PartB
    • /
    • v.16B no.4
    • /
    • pp.281-288
    • /
    • 2009
  • This paper proposes a novel algorithm for the efficient classification and annotation of medical images, especially X-ray images. Since X-ray images have a bright foreground against a dark background, we need to extract the different visual descriptors compare with general nature images. In this paper, a Color Structure Descriptor (CSD) based on Harris Corner Detector is only extracted from salient points, and an Edge Histogram Descriptor (EHD) used for a textual feature of image. These two feature vectors are then applied to a multi-class Support Vector Machine (SVM), respectively, to classify images into one of 20 categories. Finally, an image has the Annotation Code Array based on the pre-defined hierarchical relations of categories and priority code order, which is given the several optimal keywords by the Annotation Code Array. Our experiments show that our annotation results have better annotation performance when compared to other method.

A Framework of Recognition and Tracking for Underwater Objects based on Sonar Images : Part 1. Design and Recognition of Artificial Landmark considering Characteristics of Sonar Images (소나 영상 기반의 수중 물체 인식과 추종을 위한 구조 : Part 1. 소나 영상의 특성을 고려한 인공 표식물 설계 및 인식)

  • Lee, Yeongjun;Lee, Jihong;Choi, Hyun-Taek
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.2
    • /
    • pp.182-189
    • /
    • 2014
  • This paper proposed a framework of recognition and tracking for underwater objects using sonar images as an alternative of underwater optical camera which has the limitation of usage due to turbidity. In Part 1, a design and recognition method for 2D artificial landmark was proposed considering the practical performance of current imaging sonars. In particular, its materials are selected in order to maximize detectability based on characteristics of imaging sonar and ultrasonic waves. It has a simple and omni-directional shape which allows an easy modeling of object, and it includes region based features as identifications. Also, we proposed a real-time recognition algorithm including edge detector, Hough circle transforms, and shape matrix based recognition algorithm. The proposed methods are verified by basin tests using DIDSON.