• 제목/요약/키워드: ECO2 energy Simulation

검색결과 48건 처리시간 0.03초

원전 무선 센서 네트워크에 적합한 클러스터 헤드 체인 라우팅 프로토콜 (Cluster Head Chain Routing Protocol suitable for Wireless Sensor Networks in Nuclear Power Plants)

  • 정성민
    • 디지털산업정보학회논문지
    • /
    • 제16권2호
    • /
    • pp.61-68
    • /
    • 2020
  • Nuclear power plants have a lower cost of power generation, and they are more eco-friendly than other power generation plants. Also, we need to prepare nuclear plant accidents because of their severe damage. In the event of a safety accident, such as a radiation leak, by applying a wireless sensor network to a nuclear power plant, many sensor nodes can be used to monitor radiation and transmit information to an external base station to appropriately respond to the accident. However, applying a wireless sensor network to nuclear power plants requires routing protocols that consider the sensor network size and bypass obstacles such as plant buildings. In general, the hierarchical-based routing protocols are efficient in energy consumption. In this study, we look into the problems that may occur if hierarchical-based routing protocols are applied to nuclear power plants and propose improved routing protocols to solve these problems. Simulation results show that the proposed routing protocol is more effective in energy consumption than the existing LEACH protocol.

연료 다변화에 따른 용융 탄산염 연료전지 시스템 운전 특성 (Operating Characteristics of MCFC System on the Diversification of Fuel)

  • 임석연;성용욱;한재영;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제26권2호
    • /
    • pp.156-163
    • /
    • 2015
  • The fuel cells have been investigated in the applications of marine as the high efficient and eco-friendly power generating systems. In this study, modeling of IR Type molten carbonate fuel cell (Internal Reforming Type molten carbonate fuel cell) has been developed to analyze the feasibility of thermal energy utilization. The model is developed under Aspen plus and used for the study of system performances over regarding fuel types. The simulation results show that the efficiency of MCFC system based on NG fuel is the highest. Also, it is also verified that the steam reforming is suitable as pre-reforming for diesel fuel.

저온온수 모세유관 바닥복사 난방시스템의 성능에 관한 실험적 연구 (Experimental Study on a Low-Temperature Hot Water Capillary Radiant Floor Heating System)

  • 조진균;박병용;이용준;정원호
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.68-82
    • /
    • 2018
  • Radiant floor heating systems with capillary tubes are energy saving systems in which hot water is circulated into capillary tube with a small diameter. In this study, the heating performance of capillary tube system is investigated in an experimental study and a simulation model. The results of the study showed that, the capillary tube radiant floor heating system maintains a more stable floor surface temperature in comparison a PB pipe system. In terms of energy consumption, the capillary tube radiant floor heating system proved to be more efficient than the PB pipe heating system at $40^{\circ}C$ of low temperature hot water supply. The difference between water temperature and room temperature can be held low for heating which saves energy. Low temperature radiant floor heating system with capillary tubes have significant advantages such as health improvement, low energy cost, optimum use of heat source(boiler) and higher operational efficiency.

다양한 환경에 적용 가능한 충격흡수시설의 시뮬레이션 분석 및 실물충돌시험 결과 분석 (Analysis between Computer Simulation and Real-car Crash Test of Energy Absorption Facilities for Various Road Environments)

  • 노민형;박재홍;서창원;성정곤;윤덕근
    • 대한토목학회논문집
    • /
    • 제42권3호
    • /
    • pp.399-407
    • /
    • 2022
  • 도로안전시설 설치 및 관리 지침 차량방호 안전시설 편에서 충격흡수시설은 실물충돌시험을 통해 성능 기준을 만족하는 제품만을 현장에 설치하도록 하고 있다. 그러나 기존의 설치된 충격흡수시설의 경우 설치 환경에 따라 방호해야할 구조물과의 폭 차이로 인하여 방호성능을 발휘하지 못하는 문제점이 있다. 이에 본 연구에서는 다양한 환경에 적용하기 위하여 높이 150 mm의 W형 가드레일을 200 mm 간격으로 4단 배치하는 충격흡수시설을 LS-DYNA 컴퓨터 시뮬레이션을 이용하여 개발하고 실물충돌시험을 통하여 성능 기준을 검증하였다. 시뮬레이션을 통해 개발한 충격흡수시설이 CC2등급의 성능 기준을 만족한다는 것을 실물충돌시험으로 확인하였고 시뮬레이션 결과와 실물충돌시험 결과를 비교 분석하여 충돌 시뮬레이션의 결과가 유의미하다는 것을 확인하였다.

VAV 및 VWV시스템 적용에 따른 업무용 건축물의 에너지저감에 관한 연구 (A Study of applying VAV and VWV System to reduce Energy Consumption of Office building)

  • 송지용;홍원화;김지연;박효순
    • KIEAE Journal
    • /
    • 제13권1호
    • /
    • pp.57-63
    • /
    • 2013
  • Building Energy Efficiency Rating system was enforced in 2001 to enhance spreading high-energy performance and saving buildings. It was only for the new apartments, but expanded to new office buildings in 2010, and moreover, government offices require 1st grade of Building Energy Efficiency Rating system. Green Building Act, which is established to reduce the emissivity of carbon dioxide by reducing building energy consumption, will be enforced in 2013, and new apartments and office buildings will be subjected to it. Henceforward, it will extend to other types of buildings and will be phased in. In general, pumps and fans consume approximately half of the air-conditioning energy consumption, and about a quarter of the total building energy consumption when office buildings have total floor area of more than 10000 square meters. This study analyzed the energy demand when applying VAV(Variable Air Volume) and VWV(Variable Water Volume) System to reduce energy returns of the pumps and the fans by ECO2, which is a computer simulation program used for Building Energy Efficiency Rating system.

6kW V2H Power Converter Using Isolated CLLC DAB Converter

  • Ko, Hyun-Seok;Hwangbo, Chan;Park, Seong-Mi;Park, Sung-Jun
    • 한국산업융합학회 논문집
    • /
    • 제25권4_1호
    • /
    • pp.493-504
    • /
    • 2022
  • Recently, as interest in eco-friendliness grows, the supply of hybrid electric vehicles and pure electric vehicles (EVs) for improving fuel efficiency of automobiles is rapidly expanding. The average daily energy consumption of electric vehicles is less than 20 [%] of the total ESS capacity of the vehicle, and research on additional functions using the ESS of the vehicle is urgently needed to expand the supply of electric vehicles. V2H(Vehicle to Home), like V2G(Vehicle to Grid), includes the concept of cooperating with system stabilization using ESS of electric vehicles. In addition, it includes various operations that can realize home welfare, such as uninterrupted power supply in case of power outage at home, and power supply for home DC devices. Therefore, in order to expand the supply of eco-friendly electric vehicles, it is urgently required to develop a V2H system with various functions that can realize home welfare. In this paper, we propose a V2H system with a CLLC resonant converter and a non-isolated step-up converter that can solve different impedance and resonant frequencies depending on the power transfer direction. The proposed V2H system is 6 [kVA] applicable to 150-450 [V], the voltage range that can use the ESS voltage for electric vehicles, and is designed with a capacity that can handle instantaneous electricity use at home. In addition, in order to verify the feasibility, an experiment by Psim simulation and prototype production was performed.

간접 반사형 LED 조명기구의 반사판 형태에 따른 배광형태 및 조명환경 변화 분석 (Analysis of the Change of Intensity Distribution and Luminous Environment by Reflector Shape in Indirect Reflected LED Luminaires)

  • 김유신;최안섭
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.9-17
    • /
    • 2011
  • Development of high efficiency and eco-friendly LED source has been progressed continuously. Also, by nation's regulations, public institutions have changed existing luminaires to LED luminaires. However, there are several differences between existing luminaires and the intensity distribution of general planar LED luminaires. In case of changing existing luminaires to LED luminaires, by such differences, there are inefficiencies both quality aspect and energy aspect in luminous environment. Therefore, this study aims to conduct a study on the changes of intensity distribution and luminous environment by reflector shapes in indirect reflected LED luminaires with software for optical design of a luminaire (Photopia 2.0) and lighting design of a space (ReluxPro). This study shows the changes of intensity distribution and luminous environment of indirect reflected LED luminaires and indirect fluorescent lamp luminaires by reflector shapes.

Airship Research and Development in the Areas of Design, Structures, Dynamics and Energy Systems

  • Stockbridge, Casey;Ceruti, Alessandro;Marzocca, Pier
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제13권2호
    • /
    • pp.170-187
    • /
    • 2012
  • Recent years have seen an outpour of revived interest in the use of airships for a number of applications.Present day developments in materials, propulsion, solar panels, and energy storage systems and the need for a more eco-oriented approach to flight are increasing the curiosity in airships, as the series of new projects deployed in recent years show; moreover, the exploitation of the always mounting simulation capabilities in CAD/CAE, CFD and FEA provided by modern computers allow an accurate design useful to optimize and reduce the development time of these vehicles.The purpose of this contribution is to examine the different aspects of airship development with a review of current modeling techniques for airship dynamics and aerodynamics along withconceptual design and optimization techniques, structural design and manufacturingtechnologies and, energy system technologies. A brief history of airships is presented followed by an analysis of conventional and unconventional airships including current projects and conceptual designs.

Experimental investigation and validation of TASS/SMR-S code for single-phase and two-phase natural circulation tests with SMART-ITL facility

  • Bae, Hwang;Chun, Ji-Han;Yun, Eunkoo;Chung, Young-Jong;Lim, Sung-Won;Park, Hyun-Sik
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.554-564
    • /
    • 2022
  • The natural circulation phenomena occurring in fully integrated nuclear reactors are associated with a unique formation mechanism. The phenomenon results from a structural feature of these reactors involving upward flow from the core, located in the central-bottom region of a single vessel, and downward flow to the steam generator in the annulus region. In this study, to understand the natural circulation in a single vessel involving a multi-layered flow path, single-phase and two-phase natural circulation tests were performed using the SMART-ITL facility, and validation analysis of the TASS/SMR-S code was performed by comparing the corresponding test results. Three single-phase natural circulation tests were sequentially conducted at 15%, 10%, and 5% of full-scaled core-power without RCP operation, following which a two-phase natural circulation test was successively conducted with an artificial discharge of coolant inventory. The simulation capability of the TASS/SMR-S code with respect to the natural circulation phenomena was validated against the test results, and somewhat conservative but reasonably comparative results in terms of overall thermalhydraulic behavior were shown.

대한민국의 지역별 표준기상데이터 비교분석 (Comparison and analysis of typical metrological data by in korea)

  • 유호천;노경환;강현구;신인환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.361-366
    • /
    • 2009
  • Amid the crisis of global climate change, interest in low carbon and energy-saving building has been increasingly growing. Korea is likely to be designated as one of the countries subject to CO2 reduction under the 'Post-2012 Climate System' The efforts to minimize the building energy has been made and in line with the increasing need of low carbon and eco-friendly building, a demand for building evaluation programs has been on the rise. However, the metro logical data which is necessary for such program has not been effectively provided and moreover, the source, calculation method and period remain uncertain. This study was intended to evaluate the regional typical metro logical data (ISO TRY) provided by Korean Solar Energy Society and compile the month of test reference years (TRY), and analyze the regional weather using dry-bulb temperature, wet-bulb temperature and solar irradiance which are regarded the representative metro logical data.

  • PDF