This study assessed the feasibility of a dual-channel (DC) compound method for film dosimetry. The red channel (RC) is usually used to ensure dosimetric quality using a conventional fraction dose because the RC is more accurate at low doses within 3 Gy than is the green channel (GC). However, the RC is prone to rapid degradation of sensitivity at high doses, while degradation of the GC is slow. In this study, the DC compound method combining the RC and GC was explored as a means of providing accurate film dosimetry for high doses. The DC compound method was evaluated at various dose distributions using EBT3 film inserted in a solid-water phantom. Measurements with $10{\times}20cm^2$ radiation field and $60^{\circ}$ dynamic-wedge were done. Dose distributions acquired using the RC and GC were analyzed with root-mean-squares-error (RMSE) and gamma analyses. The DC compound method was used based on the RC after correcting the GC for high doses in the gamma analysis. The RC and GC produced comparatively more accurate RMSE values for low and high doses, respectively. Gamma passing rates with an acceptance criterion of 3%/3 mm revealed that the RC provided rapid reduction in the high dose region, while the GC displayed a gradual decrease. In the whole dose range, the DC compound method had the highest agreement (93%) compared with single channel method using either the RC (80%) or GC (85%). The findings indicate that the use of DC compound method is more appropriate in dosimetric quality assurance for radiotherapy using high doses.
항암요법과 방사선치료를 병행하여 두경부암을 치료하는 환자의 경우 항암요법과 방사선치료를 거듭할수록 구토, 메스꺼움, 식욕부진 등의 이유로 환자의 체중 감소가 생기게 된다. 체중 감소는 목의 두께 변화로 나타날 수 있으며 이로 인해 치료하고자 하는 t 타겟과 주위 정상조직의 선량 전달에도 영향을 미치며 방사선이 전달되는 방향에 위치한 피부선량의 변화가 나타날 것으로 사료된다. 특히 비인두암 환자의 경우 비인두 구조가 다른 장기보다 복잡한 구조를 지니고 있고 치료방법인 토모테라피는 수 mm 차이로 급격한 선량 변화가 발생하므로 이러한 체중 감소의 변화에 주의 깊은 관찰이 필요하다. 현재 토모테라피의 경우 매 회 치료 전 정확한 자세 재현을 위한 영상 검증을 통해 이러한 움직임을 확인하고 그 값을 보정하여 치료를 수행한다. 그러나 환자의 체중 감소로 인하여 피부선량에 전달되는 선량 변화의 검증은 되지 않고 있다. 환자의 피부선량이 증가함으로써 나타나는 부작용은 환자의 삶의 질에 영향을 미칠 뿐 만 아니라 2차 암 발생률을 높일 수 있다. 이에 환자의 체중 감소로 인하여 나타나는 환자의 목 두께를 휴먼 팬톰에 볼루스를 올리고 두께를 조절해가며 변화시켜 필름을 이용하여 피부선량의 변화가 어떻게 나타나는지 분석해보고자 한다.
목 적 : 두경부 치료 시 환자의 고정을 위해 고정용 열성형가면(Thermoplastic mask, mask)을 사용한다. 치료 중 변동의 오차가 적은 정위적방사선수술에 사용되는 특수 제작된 마스크를 토모치료에 적용 했을 때 표면선량의 변화의 경향을 알아보고 유용성을 평가해보고자 한다. 대상 및 방법 : 일반적인 마스크(conventional mask, C-mask)와 정위적방사선수술 마스크(SRS mask, S-mask)를 이용하여 인체팬텀(rando phantom)을 동일한 중심선으로 고정한 후 모의 치료를 실시하였다. 획득한 영상은 치료계획시스템(treatment planning system, TPS)을 이용하여 안와부와 침샘부위를 치료 부위로 설정하여 각 각의 토모치료계획을 세웠다. 마스크의 특성에 따른 표면선량 측정을 위해 정위적방사선수술 마스크를 기준으로 치료부위에 주변에 위치한 두꺼운 부분과 얇은 부분을 관심영역으로 설정하여 마스크의 종류에 따른 동일한 위치의 표면 선량을 비교해보았다. 그리고 토모치료기를 이용하여 모의치료와 동일한 조건으로 인체팬텀을 위치시키고 치료계획에서 설정된 관심영역의 위치에 Gafchromic EBT3 필름을 팬텀 표면에 부착 하여 마스크를 착용한 후 치료 조사하였다. 선량 농도 분석 시스템(RIT)을 이용하여 조사된 필름의 표면선량을 측정하여 마스크의 종류에 따른 표면선량 변화의 양상을 비교해보았다. 결 과 : TPS에서 마스크의 종류에 의한 표면선량 변화는 안와에서 0.65~2.53 Gy, 타액선에서 0.85~1.84 Gy의 측정 변화값을 보여주었다. Gafchromic EBT3 필름을 이용한 표면선량 측정에서는 안와에서 -0.2~+3.46 Gy, 타액선에서 1.04~3.02 Gy의 측정 변화값을 보여 주었다. Smask를 적용하였을 때 C-mask를 기준으로 하였을 때 TPS에서 최대 4.26% Gafchromic EBT3 필름에서 최대 5.82%의 각 각의 표면선량 증가 경향을 나타내었다. 결 론 : S-mask의 사용으로 인한 표면선량은 무작위적으로 변하였으나 대체적으로 유효한 범위 안에 들어옴을 알 수 있었다. 본 연구에서는 표면선량의 변화값을 극대화 하기 위해 표면에 위치한 표적을 실험 하였으며 치료 표적이 심부에 위치할 경우와 치료 계획의 조건에 따라 표면 선량은 더 감소할 것으로 생각되어지며 이는 마스크에 따른 표면선량의 차이는 피부 부작용에 영향을 미치지 않을 것으로 사료된다. 그리고 치료 중 또는 치료 간 위치변화 감소의 장점은 치료 표적이 작고 결정 장기가 밀접한 경우 S-mask의 두경부 치료 적용은 유용할 것으로 사료된다.
소조사면의 선량검증은 고선량을 1회에 치료하는 정위적방사선수술(Stereotactic radiosurgery, SRS)과 고선량을 소분할 하여 치료하는 소분할방사선치료(hypo-fractionated radiotherapy)에서 작은 크기의 종양을 치료하기 위해서 자주 사용되기 때문에 현대의 방사선치료에서 있어서 매우 중요하다. 그러나, $3cm^2$ 이하의 소조사면에 대한 선량검증은 방사선치료에서 있어서 대단한 도전이다. 소조사면의 선량검증은 (a) 측방전자균형(lateral electronic equilibrium)의 부족, (b) 급격한 선량 기울기(steep dose gradient), (c) 선원의 부분적 차폐 때문에 어렵다. 이 연구의 목적은 6 MV 광자선의 $3cm^2$ 이하의 소조사면에서 출력비율을 다양한 검출기로 측정하고 검증하는 것이다. 출력비율은 CC13 이온함, CC01 이온함, EDGE 검출기, 열발광선량계(thermoluminescence dosimeters, TLD), Gafchromic EBT2 필름을 이용하여 $0.5{\times}0.5cm^2$, $1{\times}1cm^2$, $2{\times}2cm^2$, $3{\times}3cm^2$, $5{\times}5cm^2$, $10{\times}10cm^2$의 다양한 조사면에서 측정하였다. 출력비율의 차이는 조사면의 크기가 작아질수록 검출기간의 차이는 증가하였다. 본 연구의 결과는 $3cm^2$ 이하의 소조사면의 선량측정은 CC01 이온함, EDGE 검출기와 같은 작은 크기의 방사부부피(active volume)를 가지는 검출기를 사용해야 한다는 것을 입증하였다. 또한, $3cm^2$ 이하의 소조사면에서 EDGE 검출기의 출력비율은 Gafchromic EBT2 필름의 결과와 잘 일치하였다.
목 적: 호흡동조방사선 치료 시 종양의 실제 움직임과 호흡추적장치로 측정한 피부 움직임의 차이를 자체 제작한 구동팬텀에서 가상의 종양을 이용하여 호흡과 유사하게 움직임에 따른 정적 상태, 동적 상태 및 호흡동조상태에서 표적 위치의 정확성의 측정치와 실측치를 평가하고 선량분포를 분석, 비교하고자 한다. 대상 및 방법: 호흡에 의해 움직이는 종양 측정을 위해 2차원적으로 움직이는 구동팬텀을 자체 제작하였다. 구동 팬톰의 움직임은 위. 아래 방향(SI) 각각 1.5 cm 왕복운동, 상 하 방향 2 cm으로 속도조절(1-5단계)이 되도록 하였다. 가로 4 cm, 세로 4 cm, 높이 0.5 cm의 아크릴 슬라이스에 직경 0.5 cm 종양을 납으로 표시하고, 위아래로 동일한 아크릴 슬라이스를 2장씩 쌓은 후 아크릴 슬라이스 세 번째와 네 번째 사이 Dmax 1.5 cm film을 삽입하였다. 가상의 타겟을 구동 팬텀 위에 위치시키고 6 MV X-선이 조사되는 정적인 상태, 호흡동조 및 동적인 상태에서 각각 5 Gy를 조사하였다. 구동팬텀 위에 표식자를 올린 후, 호흡추적장치를 이용하여 사전에 설정한 호흡시간의 변화에 따른 진폭과 위상변화를 분석하였다. 결 과: RPM respiratory gating system을 이용하여 호흡주기를 8단계로 나누어 각각을 12회씩 위상변화를 분석하여 평균과 표준편차를 구한결과 평균은 3.0 (1.5~1.5) sec에서 1.7 cm로 가장 크고, 3.0 (1.3~1.7) sec 5.0 (2.0~3.0) sec에서 0.2602 cm로 가장 크고 4.0 (2.0~2.0) sec에서 0.0866 cm로 가장 작았다. 또한 실측치에서 평균 및 표준편차를 구한 결과 t0에서 9.9 (6.6) mm $t_{10}$에서 10.6 mm (7.3), $t_{20}$ 16.5 mm (10.3), $t_{30}$ 10.2 mm (7.6)으로 나타났으며, 호기나 흡기 시간의 차이에 따른 규칙은 없고 대체로 균일한 평균과 표준편차의 분포를 나타내었다. 또한 정적 상태, 동적 상태 및 호흡동조상태에서 Gafchromic EBT film 의 방사선량을 분석한 결과, ICRU 62에서 권고한 90% 선량분포가 3 mm 이내에 포함되므로 정확성과 정도관리 측면에서 적합한 것으로 사료된다. 결 론: 구동팬톰을 이용하여 호흡움직임에 따른 정확성 및 선량분포차이를 Gafchromic film을 통하여 확인하였으며 결과를 바탕으로 호흡에 의해 변화가 생기는 장기에 대한 차이를 고려하여 치료계획을 한다면 종양과 정상조직에 적절한 선량계획을 세울 수 있어 치료효과 향상에 도움을 주게 될 것으로 생각한다.
목 적: 호흡에 의하여 영향을 받는 장기의 토모 치료 시 선속 폭(Field Width) 변화에 따른 종양 용적선량의 선량 전달 정확성을 분석하고 자체 제작한 Moving car를 사용하여 선량 변화의 차이를 확인하고 실질적인 종양 선량의 전달 선량을 평가해 보고자 한다. 대상 및 방법: 자체 제작한 Moving car를 사용하여 종축 움직임 차이(0.0 cm, 1.0 cm, 1.5 cm, 2.0 cm)를 적용하고 선속 폭(Field Width) 변화(1.05 cm, 2.50 cm, 5.02 cm)에 따른 측정된 선량의 값을 계산된 선량 값과 비교하여 오차범위를 파악하였다. Gafchromic EBT 필름을 이용하여 측정한 DQA (Delivery Quality Assurance) 필름의 감광정도를 선량윤곽(Dose Profile)과 Gamma Histogram을 이용하여 비교 분석하였다. 결 과: 선속 폭(Field Width) 1.05 cm, 2.50 cm, 5.02 cm일 때 오차범위가 각각 -2.00%, -0.39%, -2.55%의 선량 전달율을 나타내었다. Gafchromic EBT 필름 분석의 선량 윤곽(Dose profile)에서는 Moving car의 움직임이 있는 상태에서 종축방향으로의 움직임이 클수록, 선속 폭(Field Width)이 좁아질수록 고선량 부분에서 계산된 선량과의 오차가 크게 나타났다. Gamma histogram에서는 gamma index가 선속 폭(Field Width)이 좁을수록 움직임의 영향이 상당히 증가하는 것을 알 수 있었다. 결 론: 자체 제작한 Moving car를 이용하여 움직이는 장기의 종축선량 차이를 확인할 수 있었으며 토모 치료 시 선속 폭(Field Width)을 작게 하고 호흡에 의한 장기의 움직임을 최소화하기 위하여 호흡조절 장치와 고정기구의 개발이 필요하리라 사료된다.
눈꺼풀에 발생한 종양의 치료를 위해서는 종종 고에너지 전자선이 이용되며, 이 경우 환자의 시력 보호를 위해 금속차폐체를 눈꺼풀과 안구 사이에 삽입하고 방사선 치료를 시행한다. 차폐체에 접한 눈꺼풀 안쪽의 방사선량 확인을 위해서는 매우 작은 측정도구가 필요하며, 굽은 경계면의 특성상 유연한 측정도구가 바람직한데, radiochromic 필름 도시메트리는 이 목적에 매우 적합하다. 작으면서도 휘어진 경계면을 따라서 선량을 측정하기 위해, 눈꺼풀 팬텀과 차폐체 사이에 3-mm 폭의 EBT2 필름 띠를 삽입하고, 6MeV의 전자선을 조사 후, 선량분포를 얻었다. 금속차폐체와 동일한 크기로 아크릴 재질의 차폐체를 제작하여, 금속인공영상물이 없는 CT 영상을 얻은 후, 이를 이용하여 몬테칼로 전산모사를 수행하였다. 전산모사에서는 실제 안구차폐체의 재질을 따라 텅스텐, 알루미늄 및 스테인레스 스틸 등의 물질 정보를 이용하였다. 이렇게 얻은 전산모사 결과는 필름 측정과 2.1% 내에서 일치하였다. 밀리미터 크기 정도로 작고 또한 휘어진 영역에서 radiochromic 필름 도시메트리는 취급도 용이할 뿐만 아니라 만족스런 정확도를 보여주고 있다.
Kim, Juhye;Park, Kwangwoo;Yoon, Jeongmin;Lee, Eungman;Cho, Samju;Ahn, Sohyun;Park, Jeongeun;Choi, Wonhoon;Lee, Ho
한국의학물리학회지:의학물리
/
제27권4호
/
pp.189-195
/
2016
This paper aims to verify the clinical feasibility of a custom-made film created by a laser cutting tool for End-to-End (E2E) quality assurance in robotic intensity modulated radiation therapy system. The custom-made film was fabricated from the Gafchromic EBT3 film with the size of $8^{{\prime}{\prime}}{\times}10^{{\prime}{\prime}}$ using a drawing that is identical to the shape and scale of the original E2E film. The drawing was created by using a computer aided design program with the image file, which is obtained by scanning original E2E film. Beam delivery and evaluations were respectively performed with the original film and the custom-made film using fixed-cone collimator on three tracking modes: 6D skull (6DS), Xsight spine (XS), and Xsight lung (XL). The differences between total targeting errors of the original and custom-made films were recorded as 0.17 mm, 0.3 mm, and 0.17 mm at 6DS, XS, and XL tracking modes, respectively. This indicates that the custom-made film could yield nearly equivalent results to those of the original E2E film, given the uncertainties caused by distortions during film scanning and vibrations associated with film cutting. By confirming the clinical feasibility of a custom-made film for E2E testing, it can be expected that economic efficiency of the testing will increase accordingly.
목 적 : 본 연구는 colloid gel(slime)을 자체 제작하여, 방사선치료에서 불규칙한 환자 체표면에 대한 보상체로 적용하기 위하여 유용성을 평가하고자 한다. 대상 및 방법 : 본 연구를 위하여 치료에 적합한 colloid gel을 자체적으로 제작하였고, 방사선 치료 적용 가능성 평가를 위해 네 가지 실험을 하였다. 치료 장비 및 CT 장비로는 Trilogy(Varian)와 CT(SOMATOM, Siemens)를 이용하였다. 첫 번째로 colloid gel의 조성에 따른 균질도를 EBT3 Film(RIT)을 이용하여 측정하였다. 두 번째는 colloid gel의 Hounsfield Unit(HU)값을 CRIS phantom과 Eclipse RTP(Eclipse 13.1, Varian) 및 CT 촬영을 이용하여 선량 측정 및 확인을 하였다. 세 번째로 colloid gel의 치료 기간 내 변형 및 변질을 검사하기 위하여 ion chamber(PTW-30013, PTW)를 이용하여 매일 3회씩, 2주간 측정하였다. 네 번째 실험은 자체 제작한 아크릴 팬텀을 이용하여 실제 치료와 유사한 환경에서 bolus, rice, colloid gel을 이용한 치료계획 및 측정된 선량 분포 비교하였고, 추가적으로 dose profile도 확인하였다. 결 과 : 첫 번째 실험에서 조성된 colloid gel case 1, 2, 3의 밀도는 각각 평균 $1.02g/cm^3$, $0.99g/cm^3$, $0.96g/cm^3$이었으며, 6 MV 및 9 MeV에서 측정된 균질도를 판단하였을 때 case 1이 표준편차 1.55, 1.98로 다른 case들에 비해 더 균질한 것으로 확인되었다. 두 번째 실험에서는 HU값은 case 1, 2, 3 평균 15 HU로 확인되었으며, 치료계획과 측정된 선량을 비교하였을 때 9, 12 MeV 모든 측정 위치에서 1 % 이내 차이를 보였으며, 6 MV는 두 측정 위치에서 -1.53 %, -1.56 % 차이로 전체 2 % 내의 오차를 보였다. 세 번째 실험에서는 2주 동안 측정하였을 때 colloid gel의 선량변화가 1 % 내외로 측정되었다. 네 번째 실험에서는 치료계획과 EBT3 film으로 측정된 결과를 비교하였을 때 6 MV에서는 bolus, rice 모두 비슷한 선량 차이를 보였으며, 9 MeV에서는 photon과 달리 colloid gel이 bolus, rice와 비교하여 선량 차이가 적게 나는 것을 확인하였다. Dose profile 면에서도 colloid gel이 bolus, rice보다 균일한 dose 분포를 보였다. 결 론 : 본 연구에서 방사선치료를 위해 제작된 colloid gel의 밀도는 $1.02g/cm^3$로 물의 밀도와 비슷하며, 방사선치료 과정 동안 변질 및 변형이 확인되지 않았다. Colloid gel 제작 시 밀도에 유의를 해야 하지만, bolus, rice보다 환자의 체표면에 대한 충분한 보상을 통해 선량을 균일하게 전달할 수 있고, 저가에 제작을 할 수 있다는 점에서도 충분한 장점이 있다. 앞으로 임상적용을 위한 추가적인 실험 및 연구를 통해 방사선치료에 적용할 수 있을 것으로 사료된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.