• Title/Summary/Keyword: E1 pulse

Search Result 335, Processing Time 0.027 seconds

Laser scribing for buried contact solar cell processing (전극함몰형 태양전지의 제조를 위한 레이저 scribing)

  • 조은철;조영현;이수홍
    • Electrical & Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.593-599
    • /
    • 1996
  • Laser scribing of silicon plays an important role in metallization including the grid pattern and the front surface geometry which means aspect ratio of metal contacts. To make a front metal electrode of buried contact solar cell, we used ND:YAG lasers that deliver average 3-4W at TEM$\_$00/ mode power to sample stage. The Q-switched Nd:YAG laser of 1.064 gm wavelength was used for silicon scribing with 20-40.mu.m width and 20-200.mu.m depth capabilities. After silicon slag etching, the groove width and depth for buried contact solar cell are -20.mu.m and 30-50.mu.m respectively. Using MEL 40 Nd:YAG laser system, we can scribe the silicon surface with 18-23.mu.m width and 20-200.mu.m depth controlled by krypton arc lamp power, scan speed, pulse frequency and beam focusing. We fabricated a buried contact Silicon Solar Cell which had an energy conversion efficiency of 18.8 %. In this case, the groove width and depth are 20.mu.m and 50.mu.m respectively.

  • PDF

Microstructure and Electric Properties of Ferroelectric SrBi$_2$Ta$_2$O$_9$ Thin Films Deposited by Modified Rf Magnetron Sputtering Technique (Modified Rf Magnetron Sputtering에 의해 Pt/Ti/SiO$_2$/Si 기판위에 제조된 강유전체 SrBi$_2$Ta$_2$O$_9$ 박막의 미세구조 및 전기적 특성 연구)

  • 양철훈;윤순길
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.5
    • /
    • pp.472-478
    • /
    • 1998
  • Ferroelectric SrBi2Ta2O9(SBT) films were deposited on Pt/Ti/SiO2/Si substrates at 50$0^{\circ}C$ using a sintered SBT target Bi and Ta targets by modified rf magnetron sputtering and then were annealed at 80$0^{\circ}C$ for 10min in oxygen ambinet(760 torr) The composition of the SBT films could be easily controlled using the mul-ti-targets. The film composition of {{{{ {Sr }_{0.8 } {Bi }_{2.9 } {Ta}_{2.0 } {O }_{9 } }} was obtained with SBTd sputtering power of 100 W Bi of 25W and Ta of 10 W. A 250nm thick SBT films exhibited a dense and uniform microstructure and showed the remanent polarization(Pr) of 14.4 $\mu$C/cm2 and the coercive field({{{{ {E }_{c } }})of 60 kV/cm at applied voltage of 5 V. The SBT films show practically no polarization fatigue up to {{{{ {10 }_{10 } }} cycles under 5V bipolar pulse. The retention characteristics of the SBT films looked very promising and the leakage current density of the SBT films was about 1.23$\times${{{{ {10 }^{-7 } }}A/c{{{{ {m }^{2 } }} at 120kV/cm.

  • PDF

Ultrasonic Detection of Cracks in Studs and Bolts Using Dynamic Predictive Deconvolution and Wave Shaping

  • Suh, Dong-Man;Kim, Whan-Woo;Kim, Dae-Yen;Chung, Jin-Gyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.1E
    • /
    • pp.44-53
    • /
    • 1998
  • Bolt degradation has become a major issue in the nuclear industry since the 1980's due to failure during operation. If small cracks in stud bolt are not detected early enough, they grow rapidly and cause catastrophic disasters. Their detection, despite its importance, is known to be a very difficult problem due to the complicated structures of the stud bolts. This paper presents a method of detecting and sizing a small crack in the root between two adjacent crests in threads. The key idea is from the fact that the Rayleigh wave propagates slowly along a crack from the tip to the opening and is reflected from the opening mouth. When there exists a crack, a small delayed pulse due to the Rayleigh wave is detected between large regularly spaced pulses from the thread. The delay time is the same as the propagation delay time of the slow Rayleigh wave and is proportional to the size of the crack. To efficiently detect the slow Rayleigh wave, three methods based on digital signal processing are proposed : modified wave shaping, dynamic predictive deconvolution, and dynamic predictive deconvolution combined with wave shaping.

  • PDF

그래핀 전극을 가진 $V_3Si$ 나노입자 저항변화 메모리 소자의 전기적 특성연구

  • Kim, Dong-Uk;Lee, Dong-Uk;Jo, Seong-Guk;Kim, Eun-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.353-353
    • /
    • 2013
  • 최근 고밀도 메모리 반도체의 재료와 빠른 응답을 요구하는 나노입자를 이용한 비휘발성 메모리 소자의 제작에 대한 연구가 활발히 진행되고 있다. 특히, 비휘발성 메모리 소자 중 하나인 저항 변화 메모리 소자는 인가되는 전압에 따라 저항이 급격히 변화하여 적어도 서로 다른 두 저항 상태를 스위칭할 수 있는 물질을 이용하는 소자이다. 따라서 본 연구에서는 화합물 중에서 비휘발성 메모리 장치의 전기적 특성을 향상시킬 수 있는 실리사이드 계열의 바나듐 실리사이드($V_3Si$) 박막을 열처리 과정을 통하여 수 nm 크기의 나노입자로 제작하여, 그래핀을 하부 전극으로 하는 저항 변화 메모리 소자를 제작하였다. p-type (100) 실리콘 기판에 단일층으로 형성되어 있는 그래핀 상에 약 10 nm 두께의 저항 변화층($SiO_2$)을 각각 초고진공 스퍼터링 방법으로 성장시킨 후 $V_3Si$ 나노입자를 제작하기 위해서 $V_3Si$ 금속 박막을 스퍼터링 방법으로 4~6 nm의 두께로 저항 변화층 사이에 증착시켰으며, 급속 열처리 방법으로 질소 분위기에서 $800^{\circ}C$로 5초 동안 열처리하여 $V_3Si$ 나노 입자를 형성하였다. 마지막으로 200 nm 두께의 Pt을 증착하였다. 하부 전극으로 형성되어 있는 그래핀은 라만 분광법을 이용하여 확인하였으며, 제작된 소자의 전기적인 측정은 Agilent E4980A LCR meter, 1-MHz HP4280A와 HP 8166A pulse generator, HP4156A precision semiconductor parameter analyzer을 이용하여 전기적인 특성을 확인하였다.

  • PDF

Electrochemical Behavior of Mordant Red 19 and its Complexes with Light Lanthanides

  • Sang Kwon Lee;Taek Dong Chung;Song-Ju Lee;Ki-Hyung Chjo;Young Gu Ha;Ki-Won Cha;Hasuck Kim
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.5
    • /
    • pp.567-574
    • /
    • 1993
  • Mordant Red 19(MR19) is reduced at mercury electrode at -0.67 V vs. Ag/AgCl with two electrons per molecule in pH 9.2 buffer by differential pulse polarography and linear sweep voltammetry. The peak potential is dependent on the pH of solution. The exhaustive electrolysis, however, gives 4 electrons per molecule because of the disproportionation of the unstable hydrazo intermediate. The electrochemical reduction of lanthanide-MR19 complexes is observed at more cathodic potential than that of free ligand. The difference in peak potentials between complex and free ligand varies from 75 mV for $La^{3+}$ to 165 mV for $Tb^{3+}$ and increases with increasing the atomic number of lanthanide. The electrochemical reduction of lanthanide complexes with MR19 is due to the reduction of ligand itself, and it can be potentially useful as an indirect method for the determination of lanthanides. The shape of i-E curves and the scan rate dependence indicates the presence of adsorption and the adsorption was confirmed by potential double-step chronocoulometry and the effect of standing time. Also the surface excess of the adsorbed species and diffusion coefficients are determined. The composition of the complex is determined to be 1 : 2 by spectrophotometric and electrochemical methods.

Methods for improving meat protein digestibility in older adults

  • Seung Yun Lee;Ji Hyeop Kang;Da Young Lee;Jae Won Jeong;Jae Hyeon Kim;Sung Sil Moon;Sun Jin Hur
    • Journal of Animal Science and Technology
    • /
    • v.65 no.1
    • /
    • pp.32-56
    • /
    • 2023
  • This review explores the factors that improve meat protein digestibility and applies the findings to the development of home meal replacements with improved protein digestion rates in older adults. Various methods improve the digestion rate of proteins, such as heat, ultrasound, high pressure, or pulse electric field. In addition, probiotics aid in protein digestion by improving the function of digestive organs and secreting enzymes. Plant-derived proteases, such as papain, bromelain, ficin, actinidin, or zingibain, can also improve the protein digestion rate; however, the digestion rate is dependent on the plant enzyme used and protein characteristics. Sous vide processing improves the rate and extent of protein digestibility, but the protein digestion rate decreases with increasing temperature and heating time. Ultrasound, high pressure, or pulsed electric field treatments degrade the protein structure and increase the proteolytic enzyme contact area to improve the protein digestion rate.

Assessing pollutants' migration through saturated soil column

  • Smita Bhushan Patil;Hemant Sharad Chore;Vishwas Abhimanyu Sawant
    • Membrane and Water Treatment
    • /
    • v.14 no.2
    • /
    • pp.95-106
    • /
    • 2023
  • In the developing country like India, groundwater is the main sources for household, irrigation and industrial use. Its contamination poses hydro-geological and environmental concern. The hazardous waste sites such as landfills can lead to contamination of ground water. The contaminants existing at such sites can eventually find ingress down through the soil and into the groundwater in case of leakage. It is necessary to understand the process of migration of pollutants through sub-surface porous medium for avoiding health risks. On this backdrop, the present paper investigates the behavior of pollutants' migration through porous media. The laboratory experiments were carried out on a soil-column model that represents porous media. Two different types of soils (standard sand and red soil) were considered as the media. Further, two different solutes, i.e., non-reactive and reactive, were used. The experimental results are simulated through numerical modeling. The percentage variation in the experimental and numerical results is found to be in the range of 0.75- 11.23 % and 0.84 - 1.26% in case of standard sand and red soil, respectively. While a close agreement is observed in most of the breakthrough curves obtained experimentally and numerically, good agreement is seen in either result in one case.

A survey research to develope a personal health record application for atopic dermatitis in Korean medicine (아토피피부염 개인건강기록 어플리케이션 개발을 위한 전문가 집단 설문조사 연구)

  • Kim, Young-Eun;Kim, An-Na;Lee, Dong-Hyo;Park, Min-Cheol;Son, Mi Ju;Jang, Hyun-Chul
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.29 no.3
    • /
    • pp.1-13
    • /
    • 2016
  • Objectives : We conducted a survey aimed at developing a personal health record application for the treatment of atopic dermatitis in Korean medicine .Methods : We conducted a survey on Korean medicine doctors who attended the Korean Medicine Ophthalmology and Otolaryngology and Dermatology conference 2016. The questionnaire was based on priority of usage of the diagnostic indices and tools, and intention to use the personal health record application for treatment of atopic dermatitis in the clinic.Results : Data were collected from 50 Korean medicine doctors. Ninety-six per cent of respondents replied that they were willing to use the personal health record application for treating atopic dermatitis. Among the diagnostic indices related to atopic dermatitis, Korean medicine doctors regarded the following as important in the order of priority, i.e., condition of skin, lifestyle, risk factors, symptoms other than those of skin, past history, family history and medical history, results of tongue, pulse, and abdomen investigation, and constitution. These results did not vary with the purpose of diagnosis, and the results were consistent with those obtained with the intention to use diagnostic. Over 50% of respondents replied that they use immunoglobulin E, scoring atopic dermatitis, and visual analogue scale among the diagnostic tools.Conclusions : Our survey was conducted on clinicians who are the intended users of the personal health record application for the treatment of atopic dermatitis; hence, the results of this study can be helpful for developing a useful personal health record application for atopic dermatitis in the clinic.

The Power of Simultaneous Multi-frequency Observations for mm-VLBI: Beyond Frequency Phase Transfer

  • Zhao, Guang-Yao;Algaba, Juan Carlos;Lee, Sang Sung;Jung, Taehyun;Dodson, Richard;Rioja, Maria;Byun, Do-Young;Hodgson, Jeffrey;Kang, Sincheol;Kim, Dae-Won;Kim, Jae-Young;Kim, Jeong-Sook;Kim, Soon-Wook;Kino, Motoki;Miyazaki, Atsushi;Park, Jong-Ho;Trippe, Sascha;Wajima, Kiyoaki
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.46.2-46.2
    • /
    • 2017
  • Atmospheric propagation effects at millimeter wavelengths can significantly alter the phases of radio signals and reduce the coherence time, putting tight constraints on high frequency Very Long Baseline Interferometry (VLBI) observations. In previous works it has been shown that non-dispersive (e.g. tropospheric) effects can be calibrated with the frequency phase transfer (FPT) technique. The coherence time can thus be significantly extended. Ionospheric effects, which can still be significant, remain however uncalibrated after FPT, as well as the instrumental effects. In this work, we implement a further phase transfer between two FPT residuals (i.e. so-called FPT2) to calibrate the ionospheric effects based on their frequency dependence. We show that after FPT2, the coherence time at 3 mm can be further extended beyond 8 hours, and the residual phase errors can be sufficiently canceled by applying the calibration of another source, which can have a large angular separation from the target (> $20{\circ}$). Calibrations for all-sky distributed sources with a few calibrators are also possible after FPT2. One of the strengths and uniqueness of this calibration strategy is the suitability for high frequency all-sky survey observations including very weak sources. We discuss the introduction of a pulse calibration system in the future to calibrate the remaining instrumental effects and allowing the possibility of imaging the source structure at high frequencies with FPT2, where all phases are fully calibrated without involving any sources other than the target itself.

  • PDF

V3Si 나노입자 메모리소자의 열적안정성 및 전하누설 근원분석

  • Kim, Dong-Uk;Lee, Dong-Uk;Jo, Seong-Guk;Kim, Eun-Gyu;Lee, Se-Won;Jeong, Seung-Min;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.302-302
    • /
    • 2012
  • 최근 비 휘발성 메모리 시장의 확대와 수요가 많아지면서, 비휘발성 메모리 소자의 제작에 대한 연구가 활발히 진행되고 있다. 특히, 실리사이드 나노입자를 적용한 소자는 현 실리콘 기반의 반도체 공정의 적용이 용이하다. 따라서 본 연구에서는 실리사이드 계열의 화합물 중에서 일함수가 4.63 eV인 Vanadium silicide (V3Si) 나노입자 메모리소자를 제작하여 전기적 특성과 열 안정성에 대하여 알아보았다. p-Si기판에 약 6nm 두께의 SiO2 터널층을 건식 산화 방법으로 성장시킨 후 V3Si 나노입자를 제작하기 위해서 V3Si 금속박막을 스퍼터링 방법으로 4 nm~6 nm의 두께로 터널 절연막 위에 증착시켰다. 그리고 컨트롤 절연막으로 SiO2를 초고진공 스퍼터를 이용하여 50 nm 증착하였고, 급속 열처리 방법으로 질소 분위기에서 $800^{\circ}C$의 5초 동안 열처리하여 V3Si 나노 입자를 형성하였다. 마지막으로 200 nm두께의 Al을 증착하고, 리소그래피 공정을 통하여 채널 길이와 너비가 각각 $2{\mu}m$, $5{\mu}m$, $10{\mu}m$를 가지는 트랜지스터를 제작하였다. 제작된 시편의 V3Si 나노입자의 크기와 균일성은 투과 전자 현미경으로 확인하였고, 후 열처리 공정 이후 V3Si의 존재여부의 확인을 위해서 X-ray 광전자 분광법의 표면분석기술을 이용하여 확인하였다. 소자의 전기적인 측정은 Agilent E4980A LCR meter, 1-MHz HP4280A와 HP 8166A pulse generator, HP4156A precision semiconductor parameter analyzer을 이용하여 측정온도를 $125^{\circ}C$까지 변화시키면서 전기적인 특성을 확인하였다. 본 연구에서는 온도에 선형적 의존성을 가지는 전하누설 모델인 T-model 을 이용하여 나노입자 비휘발성 메모리소자의 전하누설 근원을 확인한 후, 메모리 소자의 동작 특성과의 물리적인 연관성을 논의하였다. 이를 바탕으로 나노입자 비휘발성 메모리소자의 열적안정성을 확보하고 소자 특성향상을 위한 최적화 구조를 제안하고자 한다.

  • PDF