• Title/Summary/Keyword: E1 pulse

Search Result 334, Processing Time 0.027 seconds

Laser Welding for Wing of a Guided Weapon (유도무기 날개의 레이저 용접기술)

  • Suh, Jeong;Lee, Jae-Hoon;Kim, Jeng-O;Chung, Koon-Seok;Jeong, Hae-Yong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.109-113
    • /
    • 2007
  • Laser welding process for wing of a guided weapon is studied. Nd;YAG pulse laser beam is used to weld the skin(STS304, thickness: 1mm) to frame(AMS 5398) of wing. Optimal laser welding condition is obtained from the mechanical testing and observation of the welded joint.

Heat Treatments Used in the Dairy Industry (유제품에 이용되는 주요 열처리 조건)

  • Oh, Sejong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.38 no.4
    • /
    • pp.230-236
    • /
    • 2020
  • Heat treatment is a fundamental processing technology in the dairy industry. The main purpose of heat treatment is to destroy pathogenic and spoilage promoting microorganisms to ensure milk safety and shelf life. Despite the development of alternative technologies, such as high-pressure processing and pulse field technology for microbial destruction, heat treatment is widely used in the dairy industry and in other food processes to destroy microorganisms. Heat treatment has contributed greatly to the success of food preservation since Pasteur's early discovery that heat treatment of wine and beer could prevent their deterioration, and since the introduction of milk pasteurization in the 1890s. In Korea, food labeling standards do not stratify heat treatments into low temperature, high temperature, and ultra-high temperature methods. Most milk is produced in Korea by pasteurization, with extended shelf life (ESL : 125--140℃ / 1-10 s). Classification based on temperature (i.e. low, high, and ultra-high), is meaningless.

A Novel IPT System Based on Dual Coupled Primary Tracks for High Power Applications

  • Li, Yong;Mai, Ruikun;Lu, Liwen;He, Zhengyou
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.111-120
    • /
    • 2016
  • Generally, a single phase H-bridge converter feeding a single primary track is employed in conventional inductive power transfer systems. However, these systems may not be suitable for some high power applications due to the constraints of the semiconductor switches and the cost. To resolve this problem, a novel dual coupled primary tracks IPT system consisting of two high frequency resonant inverters feeding the tracks is presented in this paper. The primary tracks are wound around an E-shape ferrite core in parallel which enhances the magnetic flux around the tracks. The mutual inductance of the coupled tracks is utilized to achieve adjustable power sharing between the inverters by configuring the additional resonant capacitors. The total transfer power can be continuously regulated by altering the pulse width of the inverters' output voltage with the phase shift control approach. In addition, the system's efficiency and the control strategy are provided to analyze the characteristic of the proposed IPT system. An experimental setup with total power of 1.4kW is employed to verify the proposed system under power ratios of 1:1 and 1:2 with a transfer efficiency up to 88.7%. The results verify the performance of the proposed system.

Properties of MFS capacitors with various gate electrodes using $LiNbO_3$ferroelectric thin film ($LiNbO_3$ 강유전체 박막을 이용한 MFS 커패시터의 게이트 전극 변화에 따른 특성)

  • 정순원;김광호
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.4
    • /
    • pp.230-234
    • /
    • 2002
  • Metal-ferroelectric-semiconductor(MFS) capacitors by using rapid thermal annealed $LiNbO_3$/Si structures were successfully fabricated and demonstrated nonvolatile memory operations of the MFS capacitors. The C-V characteristics of MFS capacitors showed a hysteresis loop due to the ferroelectric nature of the $LiNbO_3$thin film. The dielectric constant of the $LiNbO_3$film calculated from the capacitance in the accumulation region in the capacitance-voltage(C-V) curve was about 25. The gate leakage current density of MFS capacitor using a platinum electrode showed the least value of $1{\times}10^{-8}\textrm{A/cm}^2$ order at the electric field of 500 kV/cm. The minimum interface trap density around midgap was estimated to be about $10^{11}/cm^2$.eV. The typical measured remnant polarization(2Pr) value was about 1.2 $\mu\textrm{C/cm}^2$, in an applied electric field of $\pm$ 300 kv/cm. The ferroelectric capacitors showed no polarization degradation up to about $10^{10}$ switching cycles when subjected to symmetric bipolar voltage pulse in the 500 kHz.

Effect of imipramine or ECS on central $\beta_1$and $\beta_2$receptor Sensitivity in the Cardiovascular Response of Rat

  • Sohn, Uy-Dong;Kim, Choong-Young;Huh, In-Hoi
    • Archives of Pharmacal Research
    • /
    • v.12 no.4
    • /
    • pp.282-288
    • /
    • 1989
  • This study was investigated the effects of imipramine (IMI) and electroconvulsive shock (ECS), which are used as antidepressant therapy, on the central $\beta_1$or $\beta_2$ adrenergic receptor in anesthetized rats. The resting blood pressure and heart rate decreased in reserpinized group (5 mg/kg i. p., 24 hr before), but not in order 4 groups i. e. acute IMI (20 mg/kg i. p.. 3-5 hr before), chronic IMI (Same dose, twice a day for 14 days), siggle ECS (sinusoidal 20 Hz, 120 V for 2 sec) and repeated ECS (same condition, daily for 12 days). The increase of heart rate and hypotension evoked by 1 or 3 $\mu$g intracerebroventricular (i. c. v.) administration of (+) dobutamine, $\beta_2$-agonist, 1 or 3 $\mu$g i. c. v. was significantly attenuated in repeated ECS or reserpine treatment. And, the diminuation of pulse pressure of salbutamol also reduced by repeated ECS. These results suggest that IMI or ECS result in attenuation on tachycardia by (+) dobutamine or on hypotension by salbutamol, presumably by which the central $\beta_1$ or $\beta_2$receptor sensitivity may be suppressed, repectively.

  • PDF

Ultrasonic Velocity and Absorption Measurements for Polyacrylamide and Water Solutions

  • Bae, Jong-Rim;Kim, Jeong-Koo;Yi, Meyung-Ha
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.4E
    • /
    • pp.155-160
    • /
    • 2003
  • Both ultrasonic velocity at 3 MHz and absorption coefficient for the frequency range of 0.2-2 MHz were measured in an aqueous solution of polyacrylamide for the concentration range of 0.5% to 2.5% by weight. Pulse echo overlap method was taken for measuring the ultrasonic velocity over the temperature range of 10-90℃ and the high-Q ultrasonic resonator method was used for the absorption coefficient at 30℃. The velocity exhibited a maximum value at approximately 70℃, 71℃, 72℃, 73℃ and 74℃ in 2.5%, 2.0%, 1.5%, 1.0%, and 0.5% solutions, respectively. The velocity increased with the concentration at a given temperature. The ultrasonic absorption (a/f²) at a given temperature increased linearly with the concentration for the concentration below 1.5%, but suddenly increased for the concentration above 1.5% concentration. The value of a/f² at 1MHz was entirely due to the classical Stoke's viscous effect. The ultrasonic relaxation in polyacrylamide aqueous solutions, which may be the result of structural fluctuations of polymer molecules such as the segmental motion of the polymer chains, was observed, and at 2.5%, the value of a/f² was found to suddenly increase as frequency decreased.

Analysis of Gamma-ray Spectrum and Assessment of Corresponding Exposure Rate by Means of Response Matrix Method (Response Matrix에 의한 감마선(線) Spectrum 및 그 조사선량(照射線量) 해석(解析))

  • Kim, Seong-Kwan;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.3-14
    • /
    • 1986
  • A stud has been carried out for figuring out real photon spectrum from an observed gamma-ray spectrum by means of response matrix method, which is known one of the relatively convenient method for the estimation of exposure rate of a complex gamma ray field in comparison with graphical analysis and least square fitting of the measured spectrum. A 3'${\times}$3' cylindrical Nal(T1) scintillation detector in association with multichannel pulse height analyzer and six reference gamma ray sources covering the photon energy range of 0.05 to 2.0 MeV were used. In dividing the energy region for the construction of response matrix, two different approaches were attempted. One is dividing the entire energy region of interest into 20 bins, one of which corresponds to a width of 0.1 MeV to form $20{\times}20$ matrix, and another is dividing the 2 MeV region into 14 bins to form $14{\times}14$ matrix consists of $0.1(MeV)^{1/2}$ intervals assuming the resolution of the detector is dependent on square root of the incident photon energy. Inversion of thus constructed matrices was performed by a computor(P-E8/32) using the program attached to the end of this paper. The resultant exposure rates obtained by this method were in good agreement, within 10% with those calculated by ordinary formula widely used for a gamma-ray field of known energy and flux. It is concluded that the photen flux obtained by the response matrix constructed under the assumption of $E^{1/2}$ dependence is more realistic than that obtained by the matrix consist of identical energy bins in dosimetrical point of view.

  • PDF

Comparison of Treadmill and Cycle Ergometer in Male Korean College Students (한국 남자 대학생을 대상으로 시행한 Cardiopulmonary Exercise Test에서 Treadmill과 Cycle Ergometer의 비교 분석)

  • Chang, Yoon-Soo;Park, Jae-Min;Choi, Seung-Won;Ahn, Gang-Hyun;Lee, Jun-Gu;Yang, Dong-Kyu;Kim, Se-Kyu;Chang, Jun;Ahn, Chul-Min;Kim, Seong-Kyu;Lee, Won-Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.26-34
    • /
    • 1999
  • Background : Generally $VO_2$ max is higher in treadmill exercise than cycle ergometer exercise. According to Hassen and Wasserman, $VO_2$ max with treadmill exercise is higher at ratio of 1.11 than that with cycle ergometer. $VO_2$ max also is influenced by race, sociocultural background, exercise habit In this study, $VO_2$ max and AT were evaluated between Treadmill and cycle exercise in male Korean college students. Method: Study subjects were 44 male college students. We randomized them into 2 groups; 24 students did treadmill exercise at first and 1 week later did cycle ergometer. Another 20 students did in opposite method. They made symptom limited maximal exercise. Author defined maximal exercise as followings: 1) respiratory exchange ratio(RER)> 1.1, 2) plateau>30 sec, 3) heart rate reserve(HRR) <15%, or 4) breathing reserve (BR)<30%. Otherwise their results are excluded as submaximal exercise. Anaerobic threshold(AT) was estimated by V-slope method. Results: $VO_2$ max and AT was $45.1{\pm}6.66m\ell$/kg/min and $26.0{\pm}6.78m\ell$/kg/min in treadmill and $34.9{\pm}5.89m\ell$/kg/min, $19.5{\pm}4.77m\ell$/kg/min in Cycle Ergometer. The measured-$VO_2max$/pred-$VO_2max$ was $98.8{\pm}13.24%$ in treadmill; $84.4{\pm}13.42%$ in cycle ergometer. Comparing $VO_2$ max in treadmill with that obtained by Hassen's method, there were significant differences.(p<0.01). At maximal exercise there were differences in HRR, $O_2$/pulse, BR, $V_E$/MVV, $V_E/VCO_2$ between treadmill and cycle but not in $V_E/VO_2$, Vd/Vt, Ti/Ttot. At AT there were differences in $O_2$/pulse, BR, $V_E$/MVV, Ti/Ttot between treadmill and cycle, otherwise not. Conclusion: According to the result of this study, there are larger gap between treadmill and cycle ergometer in normal Korean adults than foreign data, and it needs further study to obtain reference value of Korea.

  • PDF

Apoptosis and Development of Porcine Parthenogenetic Embryos Activated and Cultured in Different Condition (활성화 및 배양조건이 돼지 단위발생란의 발달 및 Apoptosis에 미치는 영향)

  • Hwang In-Sun;Seo Jin-Sung;Cheong Hee-Tae;Im Gi-Sun
    • Reproductive and Developmental Biology
    • /
    • v.30 no.1
    • /
    • pp.65-70
    • /
    • 2006
  • This study investigated apoptosis and in vitro development of parthenogenetic preimplantation porcine embryos. In vitro matured oocytes for $42{\sim}44h$ were used. Apoptotic cell death was analyzed by using a terminal deoxynucleatidyl transferase mediated deoxyuridine 5-triphosphate nick-end tabling (TUNEL) assay. In experiment 1, oocytes were activated with two electric pulses (CH) of 1.2 kV/cm for $30{\mu}sec$ (E), E + 6-dimethylaminopurine (6-DMAP) or E + cycloheximide (CH) and cultured in PZM-3 under 5% $CO_2$ in air at $38.5^{\circ}C$. In experiment 2, oocytes were activated by E and cultured in PZM-3 or NCSU-23 under a gas atmosphere of 20% $O_2$ ($5%\;CO_2$, in air) or 5% $O_2$ $(5%\;CO_2,\;5%\;O_2\;90%\;N_2)\;at\;38.5^{\circ}C$. Oocytes activated with E+6-DMAP or E+CH showed higher blastocyst rates (36.3% and 32.5%) compared to E alone (27.7%). The frequency of apoptosis according to treatments were 5.3%, 7.7% and 7.1% respectively. Oocytes activated with E alone showed lower (P<0.05) frequency of apoptosis compared to other groups. In experiment 2, parthenotes cultured in PZM-3 showed slightly higher blastocyte rates (28.2% and 29.7%) compared to NCSU-23 (22.6% and 24.4%) regardless of atmosphere. Blastocysts generated in PZM-3 showed lower (P<0.05) apoptosis rate under 20% $O_2$ (9.2% vs 16.9%), whereas those in NCSU-23 had slightly lower apoptosis rate under 5% $O_2$ (14.0% vs 18.4%). This result represents that activation method and culture condition could affect the frequency of apoptosis as well as in vitro developmental rate.

Pulsed field magnetization of multi-turn short-circuited stabilized double pancake HTS coil

  • Korotkov, V.S.;Krasnoperov, E.P.;Brazhnik, P.A.;Kartamyshev, A.A.;Bishaev, A.M.;Kozinsteva, M.V.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.1
    • /
    • pp.1-5
    • /
    • 2019
  • The pulsed field magnetization of the short-circuited soldered double pancake coil made of stabilized commercial high-Tc superconductor (HTS) tape is experimentally studied. The evolution of the shielding current induced by the pulsed field and the trapped field after the pulsed magnetization was measured at 77 K. It is shown that the trapped field in the coil is close to the value reached in the field cooling process and reduces weakly at 5-fold increasing of pulsed field amplitude. The current relaxation at t~2 ms after the pulse is defined by the current sharing between the tape's copper coating and the $YBa_2Cu_3O_{7-d}$ layer. In the intermediate time scale (1 s < t < 100 s) the flux creep in HTS layer dominates. At t > 100 s the current's relaxation is defined by the resistance of soldered joint between tapes.