• Title/Summary/Keyword: E.coil

Search Result 308, Processing Time 0.032 seconds

Helical coils augment embolization of the middle meningeal artery for treatment of chronic subdural hematoma: A technical note

  • Arvin R. Wali;Alexander Himstead;Javier Bravo;Michael G. Brandel;Brian R. Hirshman;J. Scott Pannell;Andrew D. Nguyen;David R. Santiago-Dieppa
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.2
    • /
    • pp.214-223
    • /
    • 2023
  • Embolization of the middle meningeal artery (MMA) is a safe and effective adjunct in the treatment of chronic subdural hematoma. While prior authors describe the use of coils to assist embolization by preventing reflux through eloquent collaterals, we de- scribe the use of coils to further open the MMA, allowing the administration of greater amounts of embolisate for a more robust embolization. The objective of this study was to demonstrate that helical coils can safely open the MMA following the administration of polyvinyl alcohol (PVA) particles. This allows for more embolisate to be administered into the MMA for more effective treatment. A retrospective review was conducted at our institution including intraoperative images and postoperative clinical and radiographic follow up. Failure rates using MMA embolization with PVA and helical coil augmentation were compared to failure rates in the literature of MMA embolization with PVA or ethylene vinyl-alcohol copolymer alone. A total of 8 cases were reviewed in which this technique was implemented. There were no immediate complications after treatment. All patients that underwent helical coil embolization following the administration of PVA had increased amount of embolisate delivered into the MMA. All patients at follow up had resolution of the subdural hematoma on outpatient imaging. Helical coil embolization allows for more embolisate administration into the MMA and provides a technical advantage for patients that fail traditional techniques of embolization. Case series are taking place to further test this hypothesis and identify the ideal patient population that may gain maximal yield from this novel technique.

Effects of Inhibitor Concentrations on the Growth of Recombinant E. chli (재조합된 대장균의 세포성장에 미치는 저해제의 영향)

  • 차월석;나재운이동병
    • KSBB Journal
    • /
    • v.11 no.2
    • /
    • pp.132-139
    • /
    • 1996
  • The growth of recombinant E. coil and by-product production were investigated. D-cycloserine was added to increase the secretion of ${\alpha}$-amylase from recombinant E.coil. Even though cell growth was increased for optimal d-cycloserine concentration $0.1g/\ell$, extracellular ${\alpha}$-amylase activity remained almost the same as the case without d-cycloserine. It is important to achieve the high cell density for commercial production of methaboliles including ${\alpha}$-amylase. To achieve this goal, culture conditions should be selected carefully and optimized considering cell growth and by-products production. In cultivating retombinant E. coli, lactic acid and acetic acid turned out to be important by-product which affected cell yield and growth rate.

  • PDF

The Characteristics Analysis and Design for 5kW Contactless Transformer (5kW급 비접촉 변압기 설계 및 특성 분석)

  • Jang, Dong-Uk;Victor, Joao;Kim, Heol-Cheol;Lee, Dong-Su;Jung, Sang-Yong
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.703-706
    • /
    • 2011
  • Contactless systems use electromagnetic fields to transport power from railway substation to the traction system. In Korea Railroad Research Institute, KRRI, the RIPS (Railway Inductive Power Supply), has been developed. The RIPS is based on a contactless transformer with a fixed coreless primary and a moving core, compared with E shape and U shape, in the secondary. The primary coil is supply with 20 kHz current which produces a magnetic flux in the secondary core. Further this flux induces a current in the secondary coil.

  • PDF

Characteristic Analysis on Teeth Parameter of Permanent Magnet DC Motor (영구자석 직류전동기의 회전자 치(齒) Parameter에 따른 특성해석)

  • Kim, Chul-Ho;Bae, Sang-Han;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.133-135
    • /
    • 1996
  • This paper deals with the effect of teeth number variation in permanent Magnet DC motor. As teeth number varies, both flux density distribution and winding pitch are influenced, which is closely related to torque-speed characteristics, output power, and efficiency. In this study, motor design carried out using finite element method, and prototype motors were manufactured to test their performance analysis. In spite of torque ripple due to cogging effect better characteristic of machine using small teeth number was recorded than the motors with large number of rotor teeth. One of that reasons is caused by adopting large coil-length due to large number of teeth, i. e. large coil-pitch.

  • PDF

A Study of Voltage Distribution on Coils and Turns in Inverter Fed Induction Motor (인버터 구동 유도전동기의 코일과 턴에서의 전압 분포 연구)

  • Kwon, B.H.;Ahn, J.R.;Chun, T.W.;Kim, H.G.;Nho, E.C.
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.112-114
    • /
    • 2007
  • The voltage stress on line-end coil of the stator winding in the induction motor fed by a PWM inverter is analyzed, using the computer model based on multi-conductors transmission line. A method to calculate circuit parameters, especially, capacitance between the turns and ground is proposed. The voltage distributions inside coil at motor terminal depending on dv/dt are investigated through simulation studies.

  • PDF

Ultrasonic Absorption Measurements of Bovine Serum Albumin Solutions in the Frequency Range 200 kHz to 3 MHz (주파수 200 kHz-3 MHz영역에 대한 알부민용액의 초음파 흡수측정)

  • Bae, Jong-Rim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.1E
    • /
    • pp.14-19
    • /
    • 2006
  • Ultrasonic absorption and velocity spectra in bovine serum albumin (BSA) aqueous solutions have been measured at $20^{\circ}C$ over the frequency range 0.2-3 MHz in the pH range 1.5-13.2. The high-Q ultrasonic resonator and pulse-echo overlap methods were used. At acid pH's, excess absorption over that of pH 7 was explained by double relaxation. The pH dependences of the relaxation frequency and maximum absorption per wavelength, showed that the relaxation at about 200 kHz was related to the expansion of molecules and that about 3 MHz resulted from the proton transfer reaction of carboxyl group. At alkaline pH's, the excess absorption was explained by double relaxation. The relaxation at about 300 kHz was associated with a helix-coil transition, and that about 3 MHz was attributed to the proton transfer reaction of phenolic group. The rate constants and volume changes associated with these processes were estimated.

30[kVA] Superconducting generator Field coil Design (30[kVA] 초전도발전기용 계자코일 설계)

  • Baik, S.K.;Sohn, M.H.;Ko, R.K.;Lee, E.Y.;Bae, J.H.;Kwon, Y.K.;Ryu, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.232-234
    • /
    • 1998
  • Race-track type superconducting coils are used for wiggler magnets of accelerators and field coils of superconducting generators(S.C.G) and so on. The shape is different from ordinary solenoidal type magnet, so the manufacturing situation and conditions become different and moreover according to these results the output characteristics of magnet also becomes different. In this paper we are dealing with race-track type coil design that is inserted into 30(kVA) S.C.G which will be manufactured before we make l(MVA) S.C.G plant. The design procedure is based on two dimensional electromagnetic analysis including laplace equations in cylindrical coordinate.

  • PDF

Test Result Analysis of a 1MW HTS Motor for Industry Application

  • Baik, S.K.;Kwon, Y.K.;Kim, H.M.;Lee, E.Y.;Kim, Y.C.;Park, H.J.;Kwon, W.S.;Park, G.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.2
    • /
    • pp.33-36
    • /
    • 2009
  • A 1 MW class HTS (High-Temperature Superconducting) synchronous motor has been developed. This motor is aimed to be utilized for industrial application such as large motors operating in large plants. The HTS field coil of the developed motor is cooled by way of neon thermo siphonmechanism and the stator (armature) coil is cooled by water through hollow copper conductor. This paper also describes evaluation of some electrical parameters from performance test results of our motor, which was conducted at steady state in generator mode and motor mode. Open and short circuit tests were conducted in generator mode while a 1.1 MW rated induction machine was rotating the HTS machine. Electrical parameters such as mutual inductance and synchronous inductance are deduced from these tests. Load test was done upto rating torque during motor mode and efficiency was measured at each load torque.

Coil embolization and recurrence of ruptured aneurysm originating from hyperplastic anterior choroidal artery

  • Susy Youn;Sang Kyu Park;Min Jeoung Kim
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.26 no.2
    • /
    • pp.181-186
    • /
    • 2024
  • Hyperplastic anterior choroidal artery (AchA) is an extremely rare congenital vascular variant that can be mistaken for other cerebral arteries. This case report presents a 38-year-old man who presented with a severe sudden-onset headache and was diagnosed with a ruptured aneurysm originating from a hyperplastic AchA. The aneurysm was successfully treated with coil embolization, but recurrence was detected after eight months, leading to additional surgical intervention. The discussion highlights the classification of hyperplastic AchA and emphasizes the importance of recognizing this anatomical variant to avoid complications during treatment. This case report underscores the need for awareness and understanding of hyperplastic AchA in the management of cerebral aneurysms.

Antibiotic Resistance of Pathogenic Escherichia coli Isolated from Piglets with Diarrhea (설사자돈 유래 대장균의 항생물질 내성에 관하여)

  • 조광현;박노찬;권헌일;김이준;박덕상
    • Korean Journal of Veterinary Service
    • /
    • v.15 no.2
    • /
    • pp.134-143
    • /
    • 1992
  • The present study was conducted to investigate the biochemical characteristics and anti-biotic resistance of Escherichia coli(E. coli) isolated from piglets with diarrhea in Kyongbuk province during the Period from February to November 1991. 368 E. coli strains were isolated from 382 piglets with diarrhea and the biochemical and cultural reaction were compared with the classification criteria of Edwards and Ewing. Tetracycline and sulfadimethoxine were found to be highly ineffective at in vitro inhibition of the E. coli of piglets origin. The majority of E. coli were susceptible to amikacin, chloramphenicol and gentamicine. 89 (89.0%) of 100 strains of E. coil were resistant to one or more drugs. The organisms resistant to 20 or 3 drugs were 54(60.6%) of 89 strains, whereas 16(17.9%) strains were found to be resistant to one drug. 55(61.8%) out of 89 drug resistance strains carried R factors($R^+$) which were transfer-able to the recipients by conjugation.

  • PDF