• Title/Summary/Keyword: E.coil

Search Result 296, Processing Time 0.03 seconds

Monitoring of norovirus and indicator microorganisms from agricultural products and environmental samples in Korea (한국에서의 농산물 및 환경시료에서 노로바이러스와 위생지표세균의 모니터링)

  • Kang, Ji Hyun;Shim, Hye Mee;Kim, Kwang Yup
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.2
    • /
    • pp.123-131
    • /
    • 2017
  • Norovirus causes frequent epidemic viral gastroenteritis in Korea. The team for the control of noroviral foodborne outbreaks (NOROTECL) executed a project to trace the cause of norovirus contamination in agricultural products and environmental samples to reduce norovirus outbreaks in Korea. Between January and November in 2015, the contaminations by norovirus and indicator microorganisms such as coliforms, Escherichia coil and male specific coliphage (MSC) were examined in 80 agricultural products, 80 soil samples, 78 human feces samples, 3 animal feces samples, 80 agricultural water samples and 80 river water samples. Semi-nested PCR and DNA sequencing revealed 18 genogroup I and 3 genogroup II noroviruses in a total of 18 samples. These noroviruses were validated by real-time (RT)-PCR analysis. For indicator microorganisms, coliform and E. coli were respectively detected in agricultural products (68, 1%), soils (88, 7%), human feces (44, 12.8%), animal feces (67, 67%), agricultural waters (74, 30%) and river waters (96, 51%). The MSC results revealed 14 positive samples.

Evaluation of the Level of Microbial Contamination in the Manufacturing and Processing Company of Red Pepper Powder (고춧가루 제조.가공업체의 시설 및 공정별 미생물학적 오염도 평가)

  • Woo, Hye-Im;Kim, Jong-Bae;Choi, Ji-Hee;Kim, Eun-Hye;Kim, Dong-Sul;Park, Kun-Sang;Kim, Eun-Jeong;Eun, Jong-Bang;Om, Ae-Son
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.4
    • /
    • pp.427-431
    • /
    • 2012
  • This study was conducted to monitor and evaluate microbial contamination during manufacturing process in 6 red pepper powder factories. Red pepper powder samples were taken from manufacturing facilitates, working area and workers' hands to determine sanitary indicator bacteria (SIB) such as aerobic bacteria and coliform group as well as pathogenic indicator bacteria (PIB) such as Staphylococcus aureus, E.coli, Salmonella spp., Listeria monocytogenes, and Bacillus cereus. The results indicated that SIB in primary materials was detected as low as 3 log units and E.coil and Staphylococcus aureus of PIB were detected. After grinding process, aerobic bacteria, fungi, and coliform group increased 52% and 108%, respectively. In final products, PIB was not detected except for one found Staphylococcus aureus by which workers' hands were contaminated. Moreover, UV detectors in all the manufacturers were not able to reduce bacteria. Thus, this data suggest that a stringent safety management be needed to prevent cross contamination, and also reconsider effectiveness of facility.

Ag Ion Substituted HAp Coatings on Ti-6Al-4V Substrate by IBAD and It's Bactericidal Effect (Ti 합금표면의 항균성 HAp Coating에 관한 연구)

  • Jung, Moon-Young;Kim, Taik-Nam;Kim, Yun-Jong;Yim, Hyuk-Jun;Kim, Jong-Ock;Lim, Dae-young;Kim, Sun-Ok
    • The Journal of Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.189-197
    • /
    • 1998
  • Hyeroxyapatite(HAp) which has good biocompatibility was made by Wet Chemical Process. The surface of Ti-6Al-4V, coated with HAp by lon Beam Assisted Deposition (IBAD), was treated with 5ppm, 10ppm, 20ppm, and 100ppm of $AgNO_3$ solution. In this Ag impregnation process, $Ca^{2+}$ of HAp was substituted with $Ag^+$ of $AgNO_3$. In this study, the antimicrobial effect and biocompatibility of Ti-6Al-4V alloy which was coated with Ag-HAp were examined. The antimicrobial test was carried out with two kinds of bacteria(P. Aeruginosa, S. Epidermidis), which are highly infectious in a transplanting operation of implant materials. As a result of the test, it was observed that Ti-6Al-4V alloy which was treated by 20ppm of $AgNO_3$ solution has good biocompatibility. In order to observe the antimicrobial mechanism of $Ag^+$, E. coli which is the most common bacterium was treated by Ag-HAp. Then cell morphology of E. coli was observed by the transmission electron microscope(TEM). The destruction of cell wall and cytoplasm of E. coil were observed. A black spot appeared in the cytoplasm was analyzed by energy dispersive analysis X-ray (EDAX) and it showed a small amount of $Ag^+$. Thus, it was proved that $Ag^+$ destroys bacteria effectively and Ti-6Al-4V alloy which was impregnate with Ag ion show antimicrobial effect on infection bacteria.

  • PDF

Comparison of in vitro Antimicrobial Activities of Tc-99m Infecton and Ciprofloxacin (Tc-99m Infecton과 Ciprofloxacin의 생체외 항균력 비교)

  • Kim, Sung-Min;Bom, Hee-Seung;Song, Ho-Chun;Jeong, Hwan-Jeong;Kim, Ji-Yeul;Shin, Jong-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.75-80
    • /
    • 2001
  • Purpose: There was little evidence that Tc-99m labeled ciprofloxacin (Infecton) located inside of bacteria. Antimicrobial activity of Infecton could be an indirect evidence of its location. We compared in vitro antimicrobial activities of Infecton and ciprofloxacin. Materials and methods: Minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) of Infecton and ciprofloxacin against three standard strains of bacteria, Staphylococcus aureus ATCC 29213, Escherichia coli ATCC 25922 and Pseudomonas aeruginosa ATCC 27853 were measured using modified broth macrodilution techniques and pour plate methods, respectively. Data were expressed as mean${\pm}$SE (range). Results: MICs of Infecton and ciprofloxacin were $1.12{\pm}0.20\;(0.8{\sim}1.6){\mu}g/ml\;and\;0.35{\pm}0.04\;(0.2{\sim}0.4){\mu}g/ml$ for S. aureus, $0.03{\pm}0.005\;(0.025{\sim}0.05){\mu}g/ml\;and\;0.011{\pm}0.001\;(0.006{\sim}0.012){\mu}g/ml$ for E. coil, and $0.96{\pm}0.16\;(0.8{\sim}1.6){\mu}g/ml)\;and\;0.56{\pm}0.098\;(0.4{\sim}0.8){\mu}g/ml$ for P. aeruginosa, respectively. MBCs of Infecton and ciprofloxacin were $2.56{\pm}0.39\;(1.6{\sim}3.2){\mu}g/ml\;and\;0.88{\pm}0.2\;(0.4{\sim}1.6){\mu}g/ml$ for S. aureus, $0.04{\pm}0.05\;(0.025{\pm}0.05){\mu}g/ml\;and\;0.02{\pm}0.01\;(0.025{\sim}0.05)\;{\sim}g/ml$ for E coli, and $2.24{\pm}0.39\;(1.6{\sim}3.2){\mu}g/ml\;and\;1.44{\pm}0.16\;(0.8{\sim}1.6){\mu}g/ml$ for P. aeruginosa, respectively. Conclusion: Although both MICs and UBCs of Infecton were higher than those of ciprofloxacin, all three standard bacterial strains were sensitive to Infecton. It could be an indirect evidence that Tc-99m Infecton be a specific imaging agent for bacterial infection.

  • PDF

An Immunohistochemical Study on DNA Synthesis in the Periodontium during Tooth Movement in Dog (성견의 실험적 치아이동시 치주조직내 DNA 합성에 관한 면역조직화학적 연구)

  • Kim, Seong-Jin;Lim, Na-Won;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.26 no.4
    • /
    • pp.359-371
    • /
    • 1996
  • The purpose of this study was to investigate the changes about the cellular activity on DNA synthesis in the periodontal ligament of dog, in which experimental tooth movement was performed. A control and 5 experimental dogs, one and half year in age, were studied. Light force (50-75g) was applied by placing open-coil spring between left mandibular premolars ; heavy force (250-300g), between right mandibular premolars. Experimental dogs were sacrificed after infusion of bromodeoxyuridine(BrdU), at 12 hours, 1, 3, 7 and 14 days after force application, respectively. And the histologic and the immunohistochemical evaluation were performed on the obtained periodontal tissue around mandibular premolars, using anti-romodeoxyuridine antibody, which can indicate proliferating cells. The results were as follows: 1. The tearing of periodontal ligament and the vascular dilatation at tension side were observed in 12 hours, increasing until 3 days. After then it decreased; Such a finding was more evident in heavy force group than in light force group. 2. The hyalinization of the periodontal ligament and the activity of osteoclast at pressure side were observed in 12 hours, increasing until 3 days. But from 7 days on, it decreased; Such a finding was more evident in heavy force group than in light force group. 3. The BrdU expression in the control group was positive, mainly in the oral epithelium and the fibroblasts in the periodontal ligament, but negative in bone cells in periodontal ligament. 4. The BrdU expression in the experimental group was more positive in tension side than in pressure side; The expression was a little more positive in the periapical area than in the cervical area of tooth. 5. The BrdU expression in light force group was the highest in 1 day, after which it decreased; In heavy force group, it was the highest in 12 hours, after which it decreased. But in 14 days, there was no difference between the experimental group and control group.

  • PDF

A Model for the $3_{10}$/$\alpha$ Helix Transitions of $\alpha$-Aminoisobutyric Acid-Alanine Oligopeptide ($\alpha$-아미노이소부틸산-알라닌 올리고 펩티드의 $3_{10}$/$\alpha$ 나선 전이에 관한 모형)

  • Kim, Yeong Gu;Park, Hyeong Seok
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.10
    • /
    • pp.710-718
    • /
    • 1994
  • We suggest a statistical thermodynamic theory for the conformational transition of a synthetic alanine (Ala), ${\alpha}$-aminoisobutyric acid (Aib) alternative oligopeptide, Buo-(Ala-Aib)$_n$-oMe, where the terminal groups Buo and oMe stand for t-butoxy and methoxy, respectively. Pure Aib homo-oligomers have always been found to adopt $3_{10}$ helical conformations, while polyalanine has always $\alpha$ helical conformation. In an organic solvent (e.g. $CD_3$CN) it shows that the length for the $3_{10}$/${\alpha}$ helix transitions of Buo-(Ala-Aib)$_n$-oMe, is 8 at room temperature. In an aqueous solution oligopeptide has always coil conformation at room temperature. In an organic solution, helical structures of the oligopeptide are more stable than coil structure, so we studied the $$3_{10}/\alpha$ helix transitions, considering coiled-conformations, coiled and $3_{10}$ helical conformations, and coiled and $\alpha$ helical conformations by using the zipper model. We determined the values of parameters ($\sigma_A$, $\sigma_T$, $\xi_A$, $\xi_T$) from the relating published data; $\sigma_A$ = 0.00011, $\sigma_T$ = 0.0060, $\xi_A$ = 10.1, $\xi_T$ = 3.90. The distributions of $\alpha$ helical length can be N-2, N-3, N-4, ${\cdots}$, 3, 2, 1 (N = 2n) while those of $3_{10}$ helical length, N-1, N-2, N-3, N-4, ${\cdots}$, 3, 2, 1.

  • PDF

Effects of drilling process in stability of micro-implants used for the orthodontic anchorage (고정원을 위한 micro-implant 매식시 drilling 유무에 따른 안정성에 관한 연구)

  • Chang, Young-Il;Kim, Jong-Wan
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.107-115
    • /
    • 2002
  • The aim of this study was to investigate experimentally the mechanical and histological effect of drilling process on the stability of micro-implant used for the orthodontic anchorage. For this purpose, 32 micro-implants(Osas$^{(R)}$, Epoch medical, ${\phi}$1.6 mm) were inserted into maxilla, mandible and palate in two beagle dogs. 16 micro-implants(8 per dog) were inserted after drilling with pilot drilling bur (drill method group). 16 micro-implants(8 per dog) were inserted without drilling (drill-free method group). After 1 week, micro-implants were loaded by means of Ni-Ti coil spring (Ni-Ti springs-extension$^{(R)}$, Ormco) with 200-300 gm force. Following 12 weeks, the micro-implants and the surrounding bone were removed. Before sacrifice, the mobilities were tested with Periotest$^{(R)}$(Siemens). Undecalcified serial sections with the long axis were made and the histologic evaluations were done. The results of this study were as follow ; 1. The osseointegration was found in both of drill-free method group and drill method group 2. Two of drill method group and one of drill-free method group in 32 micro-implants were lost after loading. 3. The mobilities of drill-free method group were less than drill method group 4. The bone contact on surface of micro-implants in drill-free method group was more than drill method group but there was no significant difference between groups. 5. The bone density in threads of micro-implants in drill-free method group was more than drill method group and there was significant difference between groups. These results suggest that drill-free method in insertion of micro-implants is superior to drill method on the stabilities, bone remodeling and osseointegrations under early loading.

Periodontal Tissue Response Following Different Types of Fixed Retainers in Young Adult Dogs (수종의 고정성 보정장치에 따른 유성견의 치주조직 반응)

  • Jo, Myung-Hun;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.85-95
    • /
    • 2001
  • The purpose of this study was to evaluate the material for fixed type retainer, allowing physiologic tooth movement. and proper remodeling or periodontal tissue during retention period. The Present study was Performed to observe the histologic changes of periodontal tissue after application of different types of fixed type retainer after orthodontic tooth movement in young adult dogs. For this study, 4 young adult dogs were used as a experimental animal and experimental group was divided into three groups : experimental group 1 contained right side maxillayy third incisors and canines, experimental group 2 contained contralateral teeth of same animals, and control group contained mandibular premolars. And each dogs were applied the 4 different types of fixed type retainer to experimental group 1. The experimental teeth were ligated on the Sentalloy closed coil $spring^{\circledR}$(Tomy Co., Japan) from maxillary third incisors and canines and applied orthodontic force at initial 200gm-forced during 1 week. All the experimental animals were sacrificed on the 3rd week after the orthodontic teeth movement and then the specimens were taken, fixed in formalin, embeded in parafin, sectioned $6-8{\mu}m$ in thickness and stained with Hematoxylin-Eosin staining, and Masson's trichrome staining method. Examined under the light microscopy The following results were observed. 1. There were observed that decreased infiltration of giant tells in pressure side and increased the new bone forming in tension side on the specimen of 6-stranded 0.0195' $Respond^{\circledR}$(G&H Co., U.S.A.) group. Periodontal ligament fibers were much compressed or elongated in 3-stranded 0.018', 0.020' $Dentaflex^{\circledR}$(Dentarum Co., Germany), and Superbond $C&B^{\circledR}$(Sun Medical Co., Japan) groups. 2. In experimental group 1, necrotic bone inside the alveolar bone of pressure side, forming of the sharpey's fiber in osteoid tissue, and remodeling of the periodontal ligament were observed in all animals. 3. In experimental group 2, it was observed that the amount of bone resorption was equal or decreased in pressure side, and increased new bone forming and significantly decreased infiltration of giant cell than the experimental group 1. By this results, it considered that 6-stranded $Respond^{\circledR}$(G&H Co., U.S.A.) wire was the most useful material allowing early periodontal tissue remodeling.

  • PDF

A Study on the changes of periodontal tissue after orthodontic tooth movement in young adult dogs (유성견에서 교정적 치아이동에 따른 치주조직 변화에 관한 연구)

  • Kang, Nam-Yong;Yoon, Young-John;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.559-568
    • /
    • 1997
  • For orthodontic tooth movement, optimal orthodontic force should be maintained without periodontal breakdown and alveolar bone should be remodeled physiologically Therefore, To obtain proper occlusion through tooth movement within alveolar bone, we should know the biomechanics of teeth and supporting 4issues. The present study was performed to observe histologic changes of periodontal tissue immediately after application of orthodontic force and during the retention period in growing young adult dogs. In this study, experimental group contained between mandibular left canine and 1st molar and control group contained contralateral teeth of same animal. The .018'x.022' stainless steel closed coil spring(Dentaurum Co.) was ligated on the experimental teeth at initial 200gm-force from mandibular canine to 1st molar The animals(4 to 6 months aged young adult dogs) were sacrificed on 0, 14, 28 days after the finish of appliance activation, and then tissue samples were divided into hematoxylin-eosin(HE) staining section, ground section, alkaline phosphatase(ALP) staining section, and tartrate-resistant acid phosphatase(TRAP) staining section. Thereafter, the preparations were examined under light microscopy The following results were obtained: 1. Immediately after the finish of appliance activation, the periodontal space was increased in tension side, but decreased in pressure side compared to that of control. The hyalinized zone was also observed in the periodontium. 2. After the 14-day retention, peridontal space was decreased in tension side and slightly increased in pressure side compared to that of immediately after the finish of appliance activation. The hyalinized zone was repaired and a few osteoblasts showing slightly new bone formation were seen. Osteoblasts were scarcely observed along the alveolar bone. 3. Aftter the 28-day retention, the periodontal fibers are normally repaired. A lot of TRAP(+) osteoclasts md increased alveolar bone resorption were observed in pressure side, and AP(+) osteoblast and increased new bone formation were observed in tension side.

  • PDF

Study on the Aseptic Care during Labor and Delivery, and their Effects to Peripheral Morbidity (분만시 무균처치와 산후감염의 이환율과의 관계에 대한 연구)

  • 이경혜
    • Journal of Korean Academy of Nursing
    • /
    • v.2 no.1
    • /
    • pp.141-157
    • /
    • 1971
  • The peripheral infection is one of the major causes of maternal death, and although it is preventable through an effective prenatal as well as postnatal care its morbidity is increasing due to bacterial resistant to an effective antibiotics. The primary purpose of this study was to investigate the peripheral morbidity of 949 parturients who were admitted to the Obstetrics and Gynecologic department of Ewha Woman's University Hospital from January 1971 to September 1971. Among the 949 parturients, especially 40 normal parturients were selected (20, control soup was given complete aseptic care during labor and delivery and post delivery: 20, compare group was given the ordinary care practiced during labor and delivery and maternal ward of Ewha Woman's University Hospital) for bacteriologic test on vaginal flora twice, on admission and on complete cervical dilatation of each parturient. The results obtained from this study were as follows; 1. Majority of parturients age were 21 to 35 years old(90.83%), and educational level of 949 parturients was above high school. A large number of parturients socioeconomic level (according to their husbands' job) were moderate. 2, Among the 949 parturients, multipara (55.9%) were a little more than primipara (44. 1%) and 38.84% of parturients had experienced aborition. 3. In deliverty types, normal deliveries (804 cases) were more than cesarean section deliveries (145 cases) The peripheral morbidity after normal deliveries was 0.5%, and cesarean section deliveries, 23.45%. 4. Among 949 parturients incidence of hemorrhage eases (500cc or more bleeding) showed the higher peripheral morbidity (24.86%) than other cases (bleeding less than 500cc, 7.83%). 5. The majority of parturients (81.03%) had teen taking antenatal care, but most of them were taken irregular antenatal care. On the other hand, on admission, the parturients with complication were 30.32%, and their peripheral morbidity showed much higher (7.02%) than those with no complication (2.71%). 6. The incidence of peripheral morbidity in premature ruptured membrane was higher (10.91%) than normal parturienta (1.73%). 7. In the result of aseptic care during labor and delivery and post delivery, the number of cultured bacteria was legs in control group than Compare group (in control group, on admission 17, on complete cervical dilatation 12: in compare group, on admission 21 on complete cervical dilatation 21) . The most common bacteria were Staphylococcus (control group 14 on admission, compare group 16 on admission), and next Streptococcus, E- Coil, Bacillus Subtilis, in order. Also in control group the number. of colony were reduced (43%) more than in Compare group. Transient temperature elevation from 37℃ to 37.4℃ were noted in compare group (50%) than in control group (30%), and there was no one indicated above 38℃. In conclusion, the aseptic care is the test way of preventing peripheral infection as well as decreasing the puerperal morbidity. Therefore the most important nursing care is the aseptic care for each parturient during labor and delivery and peat delivery and also all the instruments must be cleaned and sterilized.

  • PDF