• Title/Summary/Keyword: E-beam radiation

Search Result 179, Processing Time 0.023 seconds

Elimination of Escherichia coli O157:H7 Contaminated in Frozen Beef by Electron Beam Irradiation (전자선 조사에 의한 동결육에 오염된 Escherichia coli O157:H7 의 제거)

  • Kwon, Oh-Jin;Yang, Jae-Seung;Lim, Seong-Il;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.771-775
    • /
    • 1997
  • Treatment with electron beam irradiation was investigated for the elimination of Escherichia coli O157:H7 which has been linked to outbreaks of foodborne illness on undercooked and raw meat. Before treatment, the maximum populations were observed at 16 hr when E. coli O157:H7 was incubated in TSB at $37^{\circ}C$. Incubation at $4^{\circ}C$ did not influence survival and growth of the strain. The numbers of E. coli O157:H7 were present about $10^{7}\;CFU/mL$ in the log $(6\;hr\;at\;37^{\circ}C)$ and stationary phase $(16\;hr\;at\;37^{\circ}C)$ of cells, respectively. Freezing $(24\;hr\;at\;-18^{\circ})$ had a more marked lethal effect. The $D_{10}$ value at $-18^{\circ}C$ of E. coli O157:H7 contaminated in frozen beef was 0.45 kGy, and inactivation factor were $6.67{\sim}11.11$ at the radiation doses of $3{\sim}5\;kGy$. Therefore, electron beam irradiation was an effective method to eleminate of E. coli O157:H7.

  • PDF

Thermal Deformation Analysis of Shadow Mask : Temperature Distribution (쉐도우마스크의 열변형 해석 -온도분포)

  • 김현규;천현태;임세영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.10
    • /
    • pp.2574-2581
    • /
    • 1993
  • A Shadow mask in C. R. T. (Cathod Ray Tube) undergoes a temperature increase due to impinging electron beams emitted from guns, and thermal deformation from such temperature rise may cause the electron beams to island on the panel, and thus give rise to depolarization. Hence the analysis of temperature distribution for a shadow mask is an important procedure for designing the shadow mask. In this paper, we are concerned with nonlinear finite element analysis of the temperature distribution on a shadow mask. First of all, we replace shadow mask, containing numerous apertures of a slit type, by an orthotropic shell without apertures, and calculate the apparent thermal conductivities. Because of thermal radiation, which is one of the major heat transfer mechanism for shadow masks, the resulting finite element equation is nonlinear and solved by the Newton method. Finally numerical examples are illustrated for a 21" FST(Full Square Tube) shadow mask, and followed by discussion.sion.

Effects of Surface Termination on Directional Emission from Photonic Crystal Waveguides

  • Chung, K.B.
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • We numerically investigate by the finite-difference time-domain method the effects of surface termination on directional emission exiting a photonic crystal waveguide. The directed power and far-field beam profile for the original proposal [E. Moreno et al., Phys. Rev. B 69, 121402 (2004)] and its enhancement [S. K. Morrison et al., Appl. Phys. Lett. 86, 081110 (2005)] are computed for different values of some important parameters. We find another surface termination condition with a positive surface displacement in the structure of the original proposal which has a negative surface displacement. Our surface termination is more effective than the original structure, and nearly as effective as the termination for the enhancement, for directional emission. Besides, our termination is simpler than that for the enhancement. We confirm the effectiveness of directional emission from our termination in its far-field beam profile, radiation intensity distribution, and additionally the wave-vector space representation by the Fourier analysis.

A Monochromatic Soft X-ray Generation from Femtosecond Laser-produced Plasma with Aluminum

  • Son, Joon-Gon;Hwang, Byung-Jun;Seo, Okkyun;Kim, Jae Myung;Noh, Do Young;Ko, Do-Kyeong
    • Journal of the Korean Physical Society
    • /
    • v.73 no.12
    • /
    • pp.1834-1839
    • /
    • 2018
  • A tabletop ultrafast soft x-ray has been generated from the laser-produce plasma with a femtosecond pulsed Ti:Sapphire laser. The estimated total flux of Al $K{\alpha}$ is of $2.2{\times}10^9photons/sec$ in $4{\pi}$ radian and the parameters related to the optical performance were obtained. The tungsten/silicon multilayer, flat quartz and bent thallium acid phthalate (TLAP) crystal were used for monochromatization of soft x-ray to refine the aluminum $K{\alpha}$ radiation and compared the respective value of $E/{\Delta}E$. To estimate the size of the x-ray source beam generated by a fs laser, the approximation using the FWHM obtained from the x-ray beam scan near the focal point was discussed, and the size of the diameter was about $9.76{\mu}m$.

Effect of Electron Beam Irradiation on Microbiological and Physicochemical Properties of Dried Red Pepper Powders of Different Origin (원산지별 건고추 분말의 미생물학적 및 이화학적 품질특성에 대한 electron beam 조사처리의 효과)

  • Lee, Hye-Jin;Kim, Gui-Ran;Park, Ki-Hwan;Kim, Jeong-Sook;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.13-19
    • /
    • 2015
  • The effects of electron beam (e-beam) irradiation at up to 10 kGy on the microbiological and physicochemical properties of dried red pepper powders were studied. Samples from Korea, China, and Vietnam were included in this study. In untreated samples, the total number of microbes, such as total aerobic bacteria, yeasts and molds, was in the range of $10^6-10^7CFU/g$. E-beam irradiation at 5 kGy reduced the microbial load by 2-4 log cycles, thus improving the hygienic quality of the samples. Moisture and pH of the samples were unchanged after e-beam irradiation. Reducing sugar content decreased at 1 kGy, followed by a gradual increase at higher radiation doses. At 5 kGy, no significant changes in the content of capsaicinoids were observed between the irradiated and control samples, while a 10 kGy dose led to a significant decrease. The content of pigments did not exhibit apparent changes with increasing dose of irradiation.

Comparison of Film Measurements, Convolution$^{}$erposition Model and Monte Carlo Simulations for Small fields in Heterogeneous Phantoms (비균질 팬텀에서 소조사면에 대한 필름측정, 회선/중첩 모델과 몬테 카를로 모사의 비교 연구)

  • 김상노;제이슨손;서태석
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.89-95
    • /
    • 2004
  • Intensity-modulated radiation therapy (IMRT) often uses small beam segments. The heterogeneity effect is well known for relatively large field sizes used in the conventional radiation treatments. However, this effect is not known in small fields such as the beamlets used in IMRT. There are many factors that can cause errors in the small field i.e. electronic disequilibrium and multiple electron scattering. This study prepared geometrically regular heterogeneous phantoms, and compared the measurements with the calculations using the Convolution/Superposition algorithm and Monte Carlo method for small beams. This study used the BEAM00/EGS4 code to simulate the head of a Varian 2300C/D. The commissioning of a 6MV photon beam were performed from two points of view, the beam profiles and depth doses. The calculated voxel size was 1${\times}$1${\times}$2$\textrm{cm}^2$ with field sizes of 1${\times}$1$\textrm{cm}^2$, 2${\times}$2$\textrm{cm}^2$, and 5${\times}$5$\textrm{cm}^2$. The XiOTM TPS (Treatment Planning System) was used for the calculation using the Convolution/Superposition algorithm. The 6MV photon beam was irradiated to homogeneous (water equivalent) and heterogeneous phantoms (water equivalent + air cavity, water equivalent + bone equivalent). The beam profiles were well matched within :t1 mm and the depth doses were within ${\pm}$2%. In conclusion, the dose calculations of the Convolution/Superposition and Monte Carlo simulations showed good agreement with the film measurements in the small field.

X-ray Photoelectron Spectroscopic Analysis of Modified MWCNT and Dynamic Mechanical Properties of E-beam Cured Epoxy Resins with the MWCNT

  • Lee, Young-Seak;Im, Ji-Sun;Yun, Seok-Min;Nho, Young-Chang;Kang, Phil-Hyun;Jin, Hang-Kyo
    • Carbon letters
    • /
    • v.10 no.4
    • /
    • pp.314-319
    • /
    • 2009
  • The surface treatment effects of reinforcement filler were investigated based on the dynamic mechanical properties of mutiwalled carbon nanotubes (MWCNTs)/epoxy composites. The as-received MWCNTs(R-MWCNTs) were chemically modified by direct oxyfluorination method to improve the dispersibility and adhesiveness with epoxy resins in composite system. In order to investigate the induced functional groups on MWCNTs during oxyfluorination, X-ray photoelectron spectroscopy was used. The thermo-mechanical property of MWCNTs/epoxy composite was also measured based on effects of oxyfluorination treatment of MWCNTs. The storage modulus of MWCNTs/epoxy composite was enhanced about 1.27 times through oxyfluorination of MWCNTs fillers at $25^{\circ}C$. The storage modulus of oxyfluorinated MWCNTs (OF73-MWCNTs) reinforced epoxy composite was much higher than that of R-MWCNTs/epoxy composite. It revealed that oxygen content led to the efficient carbon-fluorine covalent bonding during oxyfluorination. These functional groups on surface modified MWCNTs induced by oxyfluorination strikingly made an important role for the reinforced epoxy composite.

Calibration of an $^{192}Ir$ Source Used for High Dose Rate RALS. (RALS에 장착한 Ir-192 선원의 강도측정에 대한 고찰)

  • Moon, Un-Chull
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.6 no.1
    • /
    • pp.56-60
    • /
    • 1994
  • In the past, brachytherapy was carried out mostly with radium or radon sources. Currently. use of artificially produced radionuclially produced radionuclides such as $^{137}Cs,\;^{192}Ir,\;^{198}Au,\;and\;^{125}I$ is rapidly increasing. Although electrons are often used as an alternative to interstitial implants, brachytherapy continues to remain an important mode of therapy, either alone or combined with external beam. The National Council on Radiation Protection and Measurements(NCRP) recommends that the strength of any ${\gamma}$ emitter should be specified directly in terms of exposure rate in air at a specified distance such as 1m. The air kerma strength is defined as the product of air kerma rate in 'free space' and the square of the disrance of the calibration point from the source center along the perpendicular bisector, i. e., $S_k=K_L{\times}L^2$. Where $S_K$ is the the air kerma strength and K is the air kerma rate at a specified distance L. (usually 1m). Recommended units for all kerma strength are ${\mu}Gym^{2}h^{-1}$.

  • PDF

Experimental Techniques for Surface Science with Synchrotron Radiation

  • Jonhnson, R.L.;Bunk, O.;Falkenberg, G.;Kosuch, R.;Zeysing, J.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.17-17
    • /
    • 1998
  • Synchrotron radiation is produced when charged particles moving with relativistic velocities a are accelerated - for example, deflected by the bending magnets which guide the electron or p positrons in circular accelerators or storage rings. By using special focusing magnetic lattices i in the particle accelerators it is possible to make the dimensions of the particle beam very small with a hi맹 charge density which results in a light source with high b디lIiance. Synchrotron light h has important properties which make it ideal for a wide range of investigations in surface s science. The fact that the spectrum of electromagnetic radiation emitted in a bending magnet e extends in a continuum from the 얹r infra red region to hard x-rays means that it is id않I for a v variety of spectroscopic studies. Since there are no convenient lasers, or other really bright l light sources, in the vacuum ultraviolet and soft x-ray re.밍ons the development of synchrotron r radiation has enabled enormous advances to be made in this di펌C비t spectr따 re밍on. P Polarization-dependent measurements, for ex없nple ellipsometry or circular dichroism studies a are possible because the radiation has a well-defined polarization - linear in the plane of orbit w with additional right-circular, or left-circular, components for emission an생es above, or below, t the horizontal, respectively. Since the synchrotron light is emitted from a bunch of charge c circulating in a ring the light is emitted with a well-defined time structure with a short flash of l light every time a bunch passes an exit port. The time structure depends on the size of the ring a and the number and sequence of filling of the bunches. A pulsed light source enables time¬r resolved studies to be performed which provide direct information on the lifetimes and decay m modes of excited states and in addition opens up the possibility of using time of flight t techniques for spectroscopic studies. The fact that synchrotron radiation is produced in a clean u ultrahi야 vacuum environment is of gr않t importance for surce science studies. The current t비rd generation synchrotron light sources provide exceptionally high baliance and stability a and open up possibilities for experiments which would have been inconceivable only a short time ago.

  • PDF

Degradation of thin carbon-backed lithium fluoride targets bombarded by 68 MeV 17O beams

  • Y.H. Kim;B. Davids;M. Williams;K.H. Hudson;S. Upadhyayula;M. Alcorta;P. Machule;N.E. Esker;C.J. Griffin;J. Williams;D. Yates;A. Lennarz;C. Angus;G. Hackman;D.G. Kim;J. Son;J. Park;K. Pak;Y.K. Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.919-926
    • /
    • 2023
  • To analyze the cause of the destruction of thin, carbon-backed lithium fluoride targets during a measurement of the fusion of 7Li and 17O, we estimate theoretically the lifetimes of carbon and LiF films due to sputtering, thermal evaporation, and lattice damage and compare them with the lifetime observed in the experiment. Sputtering yields and thermal evaporation rates in carbon and LiF films are too low to play significant roles in the destruction of the targets. We estimate the lifetime of the target due to lattice damage of the carbon backing and the LiF film using a previously reported model. In the experiment, elastically scattered target and beam ions were detected by surface silicon barrier (SSB) detectors so that the product of the beam flux and the target density could be monitored during the experiment. The areas of the targets exposed to different beam intensities and fluences were degraded and then perforated, forming holes with a diameter around the beam spot size. Overall, the target thickness tends to decrease linearly as a function of the beam fluence. However, the thickness also exhibits an increasing interval after SSB counts per beam ion decreases linearly, extending the target lifetime. The lifetime of thin LiF film as determined by lattice damage is calculated for the first time using a lattice damage model, and the calculated lifetime agrees well with the observed target lifetime during the experiment. In experiments using a thin LiF target to induce nuclear reactions, this study suggests methods to predict the lifetime of the LiF film and arrange the experimental plan for maximum efficiency.