• Title/Summary/Keyword: E-beam radiation

Search Result 179, Processing Time 0.023 seconds

Comparison and Analysis of Photon Beam Data for Hospitals in Korea and Data for Quality Assurance of Treatment Planning System (국내 의료기관들의 광자 빔 데이터의 비교 분석 및 치료계획 시스템 정도관리자료)

  • Lee, Re-Na;Cho, Byung-Chul;Kang, Sei-Kwon
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.179-186
    • /
    • 2006
  • Purpose: Photon beam data of linear accelerators in Korea are collected, analyzed, and a simple method for checking and verifying the dose calculations in a TPS are suggested. Materials and Methods: Photon beam data such as output calibration condition, output factor, wedge factor, percent depth dose, beam profile, and beam quality were collected from 26 institutions in Korea. In order to verify the accuracy of dose calculation, ten sample planning tests were peformed. These Include square, elongated, and blocked fields, wedge fields, off-axis dose calculation, SSD variation. The planned data were compared to that of manual calculations. Results: The average and standard deviation of photon beam quality for 6, 10, and 15 MV were $0.576{\pm}0.005,\;0.632{\pm}0.004,\;and\;0.647{\pm}0.006$, respectively. The output factors of 6 MV photon beam measured at depth of dose maximum for $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.944{\pm}0.006,\;1.031{\pm}0.006,\;and\;1.055{\pm}0.007$. For 10 MV photon beam, the values were $0.935{\pm}0.006,\;1.031{\pm}0.007,\;1.054{\pm}0.0005$. The collected data were not enough to calculate average, the output factors for 15MV photon beam with field size of $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.941{\pm}0.008,\;1.032{\pm}0.004,\;1.049{\pm}0.014$. There was seven institutions $e{\times}ceeding$ tolerance when monitor unit values calculated from treatment planning system and manually were compared. The measured average MU values for the machines calibrated at SAD setup were 3 MU and 5 MU higher than the machines calibrated at SSD for 6 MV and 10 MV, respectively except the wedge case. When the wedges were inserted, the MU values to deliver 100 cGy to 5 cm depends on manufactures. When the same wedge angle was used, Siemens machine requires more MUs then Varian machine. Conclusion: In this study, photon beam data are collected and analyzed to provide a baseline value for chocking beam data and the accuracy of dose calculation for a treatment planning system.

  • PDF

Design of 4×4 Array Synthesis Horn Antenna and Radiated Power Measurement by Magnetron (4×4 배열 합성 혼 안테나 및 고출력 마그네트론에 의한 방사전력 측정)

  • Ko, Dong-Ok;Shin, Jae-Yoon;Woo, Jong-Myung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.5
    • /
    • pp.108-115
    • /
    • 2016
  • In this paper, the array synthesis horn antenna was designed and measured a radiation power after connecting magnetron. The proposed antenna was designed on the basis of the $4{\times}4$ array synthesis horn antenna characteristics. For suppressing a back-lobe, 2 step short-stub structures were attached to synthesis horn aperture upper and lower. The designed antenna has FBR(Front to Back Ratio) of 39.7 dB. HPBW(Half Power Beam Width) of the E-plane and the H-plane are $8.86^{\circ}$ and $7.35^{\circ}$ each in the measurement. For measuring a radiation power of array antenna that use a magnetron, the waveguide adaptor was designed and connected magnetron with horn antenna. Also, microstrip line coupler that replace a dielectric material with an air gap was designed for measuring a high power. As a result, average radiation output power of the $4{\times}4$ array synthesis horn antenna that connect a four magnetrons had a 0.063W.

Sterilization Effect of the Ion-exchanger Filter Using by Radiation Graft Polymerization (방사선 그라프트 중합법을 이용한 이온교환 필터의 살균효과)

  • Kim, Ye-Jin;Hong, Yong-Cheol;Kim, Min
    • Korean Chemical Engineering Research
    • /
    • v.52 no.3
    • /
    • pp.378-381
    • /
    • 2014
  • We studied the pasteurization effect of the microorganism involved in the water, using ion-exchanging filter made of the Radiation Induced Grafted Polymerization. This ion-exchanging filter is made by the graft polymerization of GMA, after irradiation of electron beam to the non-woven filter. Then, we made the ion-exchanging filter (EtA, DEA, SS) applying ion-exchanging base to the GMA filter. As a result, the density of the ion-exchanging base is shown as 2.38 mol/kg in case of EtA, 1.79 mol/kg in case of DEA and 0.75 mol/kg in case of SS. Through this filter made by this method, we measured the pasteurization power of E. coli. We found very high elimination rate such as log 4.65 in case of SS-dial filter, which is higher as 3.00 times in comparison with EtA, and 1.10 times in comparison with DEA. This data show the result is very excellent comparing with 3,000 CFU/ml. of city water treatment basis.

The Axial-displaced gregorian antenna design using Ray-tracing Method (Ray-tracing 기법을 이용한 축변위 그레고리안 안테나 설계)

  • Kim, Chun-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.6
    • /
    • pp.515-521
    • /
    • 2014
  • In this paper, we designed axis-displaced Gregorian antenna by using Ray-tracing method. This antenna improves gain, VSWR by rotating the axis of the sub-reflector to get rid of E-field wave returned from sub-reflector to feed horn. Therefore it reduce the sub-reflector size and the volume of antenna. This method is used to track the propagation path for radiation pattern of feed horn from feed horn to sub-reflector, main-reflector and air. We get E-field distribution of this antenna aperture and calculate antenna radiation pattern and optimize the antenna performance. The Ray-tracing Method was verified because the gain, radiation patterns, side lobe level, beam width and return loss of the designed antenna are very similar to CST simulation result and a measured result of the fabricated antenna.

Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

  • Jeong, Dae-Kyo;Lee, Sang-Chul;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.65-70
    • /
    • 2012
  • Purpose : The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Materials and Methods : Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. Results : The effective dose was the highest for Somatom Sensation 10 (425.84 ${\mu}Sv$), followed by AZ3000CT (332.4 ${\mu}Sv$), Somatom Emotion 6 (199.38 ${\mu}Sv$), and 3D eXaM (111.6 ${\mu}Sv$); it was the lowest for Implagraphy (83.09 ${\mu}Sv$). The CBCT showed significant variation in dose level with different device. Conclusion : The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

Enhancement of Sludge Dewaterability using a Starfish and the Radiation Technology (전자선과 불가사리 분말을 이용한 하수슬러지 탈수능 향상)

  • Yu, Dae Hyeon;Lee, Jae Gwang;Lee, Myeon Ju
    • Journal of Environmental Science International
    • /
    • v.13 no.7
    • /
    • pp.681-687
    • /
    • 2004
  • This study was focused on the manufacturing method of a dewatering aid, which would reduce the water content of the sludge cake by enhancing the dewaterability of sewage sludge. The pretreatment technology for sludge by using radiation and among diverse discarded resources were starfish selected as the material to manufacture the dewatering aid. Starfish went through the process of washing, drying, and pulverizing. The starfish powder made in this process was applied to the digested sludge generated at the sewage treatment plant of D City, and its effects were investigated. The starfish powder that was 300 ${\mu}m$ in particle size was added to the irradiated digested sludge. After the application of the condensation process, the sludge with the starfish powder added was dewatered using the belt press and centrifuge, which were the traditional pressure dewatering devices. As the result, it reduced the water content of the sludge 20% higher than the dewatered cake with no dewatering aid added and irradiation. When the powder was added, it contributed to less use of the coagulant added. The more irradiation dose, the lower water content did the dewatered cake have and the more coagulant was needed for condensation, which seems to be a disadvantage that can be compensated for by the starfish dewatering aid. A small-scaled treatment of the study to a radiation technology and dewatering aid using a discarded resource confirmed the potential of dewaterability. Based on the results saying that the dewatering aid and radiation technology can improve dewatering effects using the traditional dewatering devices, this pretreatment technology will be expected to be applied to sewage treatment plants.

Effect of Total Collimation Width on Relative Electron Density, Effective Atomic Number, and Stopping Power Ratio Acquired by Dual-Layer Dual-Energy Computed Tomography

  • Jung, Seongmoon;Kim, Bitbyeol;Yoon, Euntaek;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.165-171
    • /
    • 2021
  • Purpose: This study aimed to evaluate the effect of collimator width on effective atomic number (EAN), relative electron density (RED), and stopping power ratio (SPR) measured by dual-layer dual-energy computed tomography (DL-DECT). Methods: CIRS electron density calibration phantoms with two different arrangements of material plugs were scanned by DL-DECT with two different collimator widths. The first phantom included two dense bone plugs, while the second excluded dense bone plugs. The collimator widths selected were 64 mm×0.625 mm for wider collimators and 16 mm×0.625 mm for narrow collimators. The scanning parameters were 120 kVp, 0.33 second gantry rotation, 3 mm slice thickness, B reconstruction filter, and spectral level 4. An image analysis portal system provided by a computed tomography (CT) manufacturer was used to derive the EAN and RED of the phantoms from the combination of low energy and high energy CT images. The EAN and RED were compared between the images scanned using the two different collimation widths. Results: The CT images with the wider collimation width generated more severe artifacts, particularly with high-density material (i.e., dense bone). RED and EAN for tissues (excluding lung and bones) with the wider collimation width showed significant relative differences compared to the theoretical value (4.5% for RED and 20.6% for EAN), while those with the narrow collimation width were closer to the theoretical value of each material (2.2% for EAN and 2.3% for RED). Scanning with narrow collimation width increased the accuracy of SPR estimation even with high-density bone plugs in the phantom. Conclusions: The effect of CT collimation width on EAN, RED, and SPR measured by DL-DECT was evaluated. In order to improve the accuracy of the measured EAN, RED, and SPR by DL-DECT, CT scanning should be performed using narrow collimation widths.

DEVELOPMENT OF COMBIND WELDING WITH AN ELECTRIC ARC AND LOW POWER CO LASER

  • Lee, Se-Hwan;Massood A. Rahimi;Charles E. Albright;Walter R. Lempert
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.176-180
    • /
    • 2002
  • During the last two decades the laser beam has progressed from a sophisticated laboratory apparatus to an adaptable and viable industrial tool. Especially, in its welding mode, the laser offers high travel speed, low distortion, and narrow fusion and heat-affected zones (HAZ). The principal obstacle to selection of a laser processing method in production is its relatively high equipment cost and the natural unwillingness of production supervision to try something new until it is thoroughly proven. The major objective of this work is focused on the combined features of gas tungsten arc and a low-power cold laser beam. Although high-power laser beams have been combined with the plasma from a gas tungsten arc (GTA) torch for use in welding as early as 1980, recent work at the Ohio State University has employed a low power laser beam to initiate, direct, and concentrate a gas tungsten arcs. In this work, the laser beam from a 7 watts carbon monoxide laser was combined with electrical discharges from a short-pulsed capacitive discharge GTA welding power supply. When the low power CO laser beam passes through a special composition shielding gas, the CO molecules in the gas absorbs the radiation, and ionizes through a process known as non-equilibrium, vibration-vibration pumping. The resulting laser-induced plasma (LIP) was positioned between various configurations of electrodes. The high-voltage impulse applied to the electrodes forced rapid electrical breakdown between the electrodes. Electrical discharges between tungsten electrodes and aluminum sheet specimens followed the ionized path provided by LIP. The result was well focused melted spots.

  • PDF

Radiation Technology in the Preparation of Polyethylene Oxide Hydrophilic Gels and Immobilization of Proteases for Use in Medical Practice

  • E.I.Vereschagin;Han, Do-Hung;A.W.Troitsky;O.V.Grishin;S.E.Petrov;E.P.Gulyaeva;L.A.Bogdanova;M.V.Korobeinikov;V.L.Auslender
    • Archives of Pharmacal Research
    • /
    • v.24 no.3
    • /
    • pp.229-233
    • /
    • 2001
  • This Paper deals with the development of a technology for making a hydrophilic gel of Polyethylene oxide reception in which radiating ability is employed to cause cross-linking of Polymers in a water solution. The gel of polyethylene oxide was shown to be nontoxic contain 5-50% of polymer and be useful in composite medicinal forms along with biologically active substances including Bac. subtilis proteases. Proteases immobilized in the gel possess high thermal stability and proteolytic activity and are readily applied in medicine. The effect of immobilized proteolytic and glucolytic enzymes of Bac. subtillis (Immozimase) on the warm ischemia-reperfusion (I/R) which can cause hepatic and jejunum injury was also studied. These enzymes were immobilized on water-soluble polymer polyethylene glycol by means of an electron beam. The number of degraanulated mast cells as well as serum ALT after I/R in the group with Immozimase was decreased to almost half as compared with the control group. Pretreatment with Immozimase resulted in significant reduction of hepatic and gut neutrophil accumulation as compared with control animals. It was concluded that Immozimase has a protective effect for hepatic and gut ischemia/reperfusion, and this effect seems to be associated with prevention of leukocyte accumulation .

  • PDF

Effect of Electron Beam Irradiation on the Opto-Electrical and Transparent Heater Property of ZnO/Cu/ZnO Thin Films for the Electric Vehicle Application (전자빔 조사에 따른 ZnO/Cu/ZnO 박막의 전기광학적 특성 및 전기자동차용 투명 발열체 특성)

  • Yeon-Hak Lee;Min-Sung Park;Daeil Kim
    • Korean Journal of Materials Research
    • /
    • v.33 no.11
    • /
    • pp.497-501
    • /
    • 2023
  • ZnO/Cu/ZnO (ZCZ) thin films were deposited at room temperature on a glass substrate using direct current (DC) and radio frequency (RF, 13.56 MHz) magnetron sputtering and then the effect of post-deposition electron irradiation on the structural, optical, electrical and transparent heater properties of the films were considered. ZCZ films that were electron beam irradiated at 500 eV showed an increase in the grain sizes of their ZnO(102) and (201) planes to 15.17 nm and 11.51 nm, respectively, from grain sizes of 13.50 nm and 10.60 nm observed in the as deposited films. In addition, the film's optical and electrical properties also depended on the electron irradiation energies. The highest opto-electrical performance was observed in films electron irradiated at 500 eV. In a heat radiation test, when a bias voltage of 18 V was applied to the film that had been electron irradiated at 500 eV, its steady state temperature was about 90.5 ℃. In a repetition test, it reached the steady state temperature within 60 s at all bias voltages.