• Title/Summary/Keyword: E-beam Treatment

Search Result 154, Processing Time 0.02 seconds

Comparison of cone-beam computed tomography cephalometric measurements using a midsagittal projection and conventional two-dimensional cephalometric measurements

  • Jung, Pil-Kyo;Lee, Gung-Chol;Moon, Cheol-Hyun
    • The korean journal of orthodontics
    • /
    • v.45 no.6
    • /
    • pp.282-288
    • /
    • 2015
  • Objective: This study investigated whether it is possible to use a two-dimensional (2D) standard in three-dimensional (3D) analysis, by comparing the angles and lengths measured from a midsagittal projection in 3D cone-beam computed tomography (CBCT) with those measured by 2D lateral cephalometric radiography (LCR). Methods: Fifty patients who underwent both LCR and CBCT were selected as subjects. CBCT was reoriented in 3 different methods and the measuring-points were projected onto the midsagittal plane. Twelve angle values and 8 length values were measured on both LCR and CBCT and compared. Results: Repeated measures analysis of the variance revealed statistically significant differences in 7 angular and 5 linear measurements among LCR and 3 types of CBCT (p < 0.05). Of these 12 measurements, multiple comparisons showed that 6 measurements (ANB, AB to FH, IMPA, FMA, Co-Gn, Go-Me) were not significantly different in pairwise comparisons. LCR was significantly different from 3 types of CBCT in 3 angular (SN to FH, interincisal angle, FMIA) and 2 linear (S-Go, Co-ANS) measurements. The CBCT method was similar for all measurements, except for 1 linear measurement, i.e., S-N. However, the disparity between the mean values for all parameters was within the range of clinical measurement error. Conclusions: 3D-CBCT analysis, using midsagittal projection, is a useful method in which the 2D-LCR normative values can be used. Although the measurements changed with reorientation, these changes were not clinically significant.

Reproducibility of cone-beam computed tomographic measurements of bone plates and the interdental septum in the anterior mandible

  • Valerio, Claudia Scigliano;Alves, Claudia Assuncao e;Manzi, Flavio Ricardo
    • Imaging Science in Dentistry
    • /
    • v.49 no.1
    • /
    • pp.9-17
    • /
    • 2019
  • Purpose: This study aimed to introduce a novel method to evaluate the alveolar bone and interdental septum in the anterior mandible using cone-beam computed tomography (CBCT). Materials and Methods: Fifty-six CBCT scans from adult patients were selected. The CBCT scans were obtained before and after orthodontic treatment. The following measurements were taken: width of the alveolar bone and the interdental septum, height of the interdental septum, height of the bone plates, distance between the cementoenamel junction and marginal bone crests, and vertical positioning of the mandibular incisor, using the lingual plane as a reference. To test the reproducibility and the stability of the lingual plane, a triangle was traced in the anterior mandible. The intra-class correlation coefficient(ICC) was used to determine intra- and inter-examiner agreement. The paired Student t-test was used to evaluate the area of the triangle and the reproducibility of all measurements. Results: The ICC was excellent for the alveolar bone and dental measurements (0.9989 and 0.9977, respectively), as well as for the interdental septum (0.9987 and 0.9961, respectively). The area of the triangles showed stability in the lingual plane (P>0.05). For the alveolar bone, mandibular incisor, and interdental septum measurements, no statistically significant differences were found between the 2 examiners(P>0.05), confirming the technical reliability of the measurements. Conclusion: The method used in this study provides a valid and reproducible assessment of alveolar bone dimensions in the anterior mandible measured on CBCT images.

Fused roots of maxillary molars: characterization and prevalence in a Latin American sub-population: a cone beam computed tomography study

  • Marcano-Caldera, Maytte;Mejia-Cardona, Jose Luis;Blanco-Uribe, Maria del Pilar;Chaverra-Mesa, Elena Carolina;Rodriguez-Lezama, Didier;Parra-Sanchez, Jose Hernan
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.2
    • /
    • pp.16.1-16.12
    • /
    • 2019
  • Objectives: The upper molars generally have three roots; therefore, different combinations of fusion can occur, increasing the possibility of finding more complex root canal systems. The purpose of this study was to evaluate the prevalence and characterization of fused roots in first and second maxillary molars using cone-beam computed tomography (CBCT) in a Colombian population. Materials and Methods: A total of 1274 teeth were evaluated, of which 534 were maxillary first molars and 740 were maxillary second molars. Axial sections were made at the cervical, middle, and apical levels to determine the prevalence of root fusion and the types of fusion. Results: Overall, 43% of the molars (n = 551) presented some type of fused root. Root fusion was present in 23.4% of the maxillary first molars. The most frequent type of fused root was type 3 (distobuccal-palatal; DB-P) (58.9%). Root fusion was observed in 57.6% of the maxillary second molars, and the most prevalent type of fused root was type 6 (cone-shaped) (45.2%). Of the maxillary molars, 12.5% were classified as C-shaped. Conclusion: Within the limitations of this study, there was a high prevalence of fused roots in maxillary molars in the Colombian population, mainly in the maxillary second molars. In first molars, the most common type of fused root was type 3 (DB-P) and in second molars, the most common type was type 6 (cone-shaped). Additionally, molars with root fusion presented variation at different levels of the radicular portion, with implications for treatment quality.

Design and Application of Acrylic Electron Wedge for Improving Dose Inhomogeneities at the Junction of Electron Fields (전자선 조사야 결합부분의 선량분포 개선을 위한 acrylic electron wedge의 제작 및 사용)

  • Kim, Young-Bum;Kwon, Young-Ho;Whang, Woong-Ku;Kim, You-Hyun;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.36-42
    • /
    • 1998
  • Treatment of a large diseased area with electron often requires the use of two or more adjoining fields. In such cases, not only electron beam divergence and lateral scattering but also fields overlapping and separation may lead to significant dose inhomogeneities(${\pm}20%$) at the region of junction of fields. In this study, we made Acrylic Electron Wedges to improve dose inhomogeneities(${\pm}5%$) in these junction areas and to apply it to clinical practices. All measurements were made using 6, 9, 12, 16, 20 MeV Electron beams from a linear accelerator for a $10{\times}10\;cm$ field at 100cm of SSD. Adding a 1 mm sheet of acryl gradually from 1 mm to 15 mm acquires central axis depth dose beam profile and isodose curves in water phantom. As a result, for all energies, the practical range was reduced by approximately the same distance according to the acryl insert, e.g. a 1 mm thick acryl insert reduces the practical range by approximately 1 mm. For every mm thickness of acryl inserted, the beam energy was reduced to approximately 0.2 MeV. These effects were almost Independent of beam energy and field size. The use of Acrylic Electron Wedges produced a small increase(less than 3%) in the surface dose and a small increase(less than 1%) in X-ray contamination. For acryl inserts, thickness of 3 mm or greater, the penumbra width increased nearly linear for all energies and isodose curves near the beam edge were nearly parallel with the incident beam direction at the point of penumbra width($35\;mm{\sim}40\;mm$). We decide heel thickness and angle of the wedge at this point. These data provide the information necessary to design Acrylic Electron Wedge which can be used to improve dose uniformity at electron field junctions and it will be effectively applied to clinical practices.

  • PDF

Design and Application of Acrylic Electron Wedge to Improve Dose Inhomogeneities at the Junction of Electron Fields (전자선 조사야 결합부분의 선량분포 개선을 위한 Acrylic Electron Wedge의 제작 및 사용)

  • Kim Young Bum;Kwon Young Ho;Whang Woong Ku;Kim You Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.60-68
    • /
    • 1998
  • Treatment of a large diseased area with electron often requires the use of two or more adjoining fields. In such cases, not only electron beam divergence and lateral scattering but also fields overlapping and separation may lead to significant dose inhomogeneities(${\pm}20\%$) at the field junction area. In this study, we made Acrylic Electron Wedges to improve dose homogeneities(${\pm}5\%$) in these junction areas and considered application it to clinical practices. All measurements were made using 6, 9, 12, 16, 20MeV Electron beams from a linear accelerator for a $10{\times}10cm$ field at 100cm SSD. Adding a 1 mm sheet of acryl gradually from 1 mm to 15 mm, We acquired central axis depth dose beam profile and isodose curves in water phantom. As a result, for all energies, the practical range was reduced by approximately the same distance as the thickness of the acryl insert, e.g. a 1 mm thick acryl insert reduce the practical range by approximately 1 mm. For every mm thickness of acryl inserted, the beam energy was reduced by approximately 0.2MeV. These effects were almost independent of beam energy and field size. The use of Acrylic Electron Wedges produced a small increase $(less\;than\;3\%)\;in\;the\;surface\;dose\;and\;a\;small\;Increase(less\;than\;1\%)$ in X-ray contamination. For acryl inserts, thickness of 3 mm or greater, the penumbra width increased nearly linear for all energies and isodose curves near the beam edge were nearly parallel with the incident beam direction, and penumbra width was $35\;mm{\sim}40\;mm$. We decide heel thickness and angle of the wedge at this point. These data provide the information necessary to design Acrylic Electron Wedge which can be use to improve dose uniformity at electron field junctions and it will be effectively applicated in clinical practices.

  • PDF

Measurement of Sputtering Yield of $RF-O_2$ Plasma treated MgO Thin Films ($RF-O_2$ Plasma 처리한 MgO 박막의 스퍼터링 수율 측정)

  • Jeong, W.H.;Jeong, K.W.;Lim, Y.C.;Oh, H.J.;Park, C.W.;Choi, E.H.;Seo, Y.H.;Kim, Y.K.;Kang, S.O.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.259-265
    • /
    • 2006
  • We measured sputtering yield of RF $O_2-plasma$ treated MgO protective layer for AC-PDP(plasma display panel) using a Focused ion Beam System(FIB). A 10 kV acceleration voltage was applied. The sputtering yield of the untreated sample and the treated sample were 0.33 atoms/ion and 0.20 atoms/ion, respectively. The influence of the plasma-treatment of MgO thin film was characterized by XPS and AFM analysis. We observed that the binding energy of the O 1s spectra, the FWHM of O 1s spectra and the RMS(root-mean-square) of surface roughness decreased to 2.36 eV, 0.6167 eV and 0.32 nm, respectively.

Phase Changes of Vanadium Oxide Thin Films (산화 바나듐 박막의 상변화)

  • 선우진호;신인하;고경현;안재환
    • Journal of the Korean institute of surface engineering
    • /
    • v.25 no.6
    • /
    • pp.293-298
    • /
    • 1992
  • Various vanadium-oxide thin films were deposited by e-beam and thermal evaporation of V2O5, V2O3, and VO2 powders. Films with thickness of $2000\AA$ were subjected to annealing at $300^{\circ}C$~$450^{\circ}C$ in N2 atmosphere for the crystallization and desification purposes. For the films deposited from V2O5 and VO2 sources, sources, Magneli (VnO2n-1$ 4\leq$ $n\leq$ 8) and VO2 phase appeared at $300^{\circ}C$, respectively, but VO2 phase also transformed into Magneli phase at $450^{\circ}C$ by severe reduction. On the contrary, VO2/VO mixed phases resulted from congruent evaporation of V2O3 unchanged after the same annealing treatment due to the balanced reduction and oxidation of VO2 and VO whcih have different equilibrium O2 pressures. It is suggested that the annealing in the controlled oxidation atmosphere or the deposition using mixed oxide sources are necessary to get the film containing VO2 phase.

  • PDF

Changes in the Modulation Amplitude and the Particle Sizes of Co/Pd Multilayers During Stress Release and Interdiffusion

  • Kim, Jai-Young;Evetts, Jan-E
    • Journal of Magnetics
    • /
    • v.3 no.1
    • /
    • pp.21-30
    • /
    • 1998
  • An artificially modulated magnetic Co/Pd multilayer is one of the promising candidates for high density magneto-optic (MO) recording media, due to large Kerr rotation angle in the wavelength of a blue laser beam. however, since multilayer structure, as well as amorphous structure, is a non-equilibrium state in terms of free energy and MO recording is a kind of thermal recording which is conducted aound Curie temperature (Tc) of the recording media, when the multilayer is used for the MO recording media, changes in the multilayer structure are occurred as the amorphous structure do. Therefore, the assessment of the structural stability in the Co/Pd multilayer is crucially important both for basic research and applications. As the parameter of the structural stability in this research, modulation amplitude and particle size of the Co/Pd multilayer are measured in terms of Ar sputtering pressure and heat treatment temperature. From the results of the research, we find out that the magnetic exchange energy in the structural changes of a magnetic multilayer structure and suggest the operating temperature range for MO recording in the Co/Pd multilayer for the basic research and applications, respectively.

  • PDF

J-Integral Evaluation of Concrete Fracture Characteristics

  • Choi, Sin-Ho;Kye, Hae-Ju;Kim, Wha-Jung
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.3E
    • /
    • pp.183-189
    • /
    • 2006
  • Many researchers have recently proposed various parameters, variables of models and experimental methods to evaluate fracture properties of concrete, and their developments allow us to analyze the non-linear and quasi-brittle fracture mechanisms. This paper presents a brief treatment of the fracture parameters. Additionally, three-point bending tests were conducted to compare J-integral($J_{Ic}$) with other parameters($K_{Ic},\;G_{Ic},\;and\;G_F$). The change in parameter values with respect to the width and notch length of concrete beam specimens was also considered. The load-displacement curves were used to measure the concrete fracture toughness experimentally. From the results of experiment, it was found that the value of $G_F\;and\;J_{Ic}$ decreased as the notch depth increased and that $G_F$ was less sensitive than $J_{Ic}$. Therefore, the former, $G_F$, is more appropriate in using it as the concrete fracture toughness parameter. The values of $G_F\;and\;J_{Ic}$ increased when the width of concrete specimens increasing from 75 mm to 150 mm. Thus, the effects of the specimen width should be considered in determining the fracture toughness of concrete.

Rapid Thermal Annealing at the Temperature of 650℃ Ag Films on SiO2 Deposited STS Substrates

  • Kim, Moojin;Kim, Kyoung-Bo
    • Applied Science and Convergence Technology
    • /
    • v.26 no.6
    • /
    • pp.208-213
    • /
    • 2017
  • Flexible opto-electronic devices are developed on the insulating layer deposited stainless steel (STS) substrates. The silicon dioxide ($SiO_2$) material as the diffusion barrier of Fe and Cr atoms in addition to the electrical insulation between the electronic device and STS is processed using the plasma enhanced chemical vapor deposition method. Noble silver (Ag) films of approximately 100 nm thickness have been formed on $SiO_2$ deposited STS substrates by E-beam evaporation technique. The films then were annealed at $650^{\circ}C$ for 20 min using the rapid thermal annealing (RTA) technique. It was investigated the variation of the surface morphology due to the interaction between Ag films and $SiO_2$ layers after the RTA treatment. The results showed the movement of Si atoms in silver film from $SiO_2$. In addition, the structural investigation of Ag annealed at $650^{\circ}C$ indicated that the Ag film has the material property of p-type semiconductor and the bandgap of approximately 1 eV. Also, the films annealed at $650^{\circ}C$ showed reflection with sinusoidal oscillations due to optical interference of multiple reflections originated from films and substrate surfaces. Such changes can be attributed to both formation of $SiO_2$ on Ag film surface and agglomeration of silver film between particles due to annealing.