• Title/Summary/Keyword: E-TAP

Search Result 160, Processing Time 0.021 seconds

Effect of intracanal medications on the interfacial properties of reparative cements

  • Pereira, Andrea Cardoso;Pallone, Mariana Valerio;Marciano, Marina Angelica;Cortellazzi, Karine Laura;Frozoni, Marcos;Gomes, Brenda P.F.A.;de Almeida, Jose Flavio Affonso;de Jesus Soares, Adriana
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.2
    • /
    • pp.21.1-21.8
    • /
    • 2019
  • Objectives: The purpose of the present study was to evaluate the effect of calcium hydroxide with 2% chlorhexidine gel (HCX) or distilled water (HCA) compared to triple antibiotic paste (TAP) on push-out bond strength and the cement/dentin interface in canals sealed with White MTA Angelus (WMTA) or Biodentine (BD). Materials and Methods: A total of 70 extracted human lower premolars were endodontically prepared and randomly divided into 4 groups according to the intracanal medication, as follows: group 1, HCX; group 2, TAP; group 3, HCA; and group 4, control (without intracanal medication). After 7 days, the medications were removed and the cervical third of the specimens was sectioned into five 1-mm sections. The sections were then sealed with WMTA or BD as a reparative material. After 7 days in 100% humidity, a push-out bond strength test was performed. Elemental analysis was performed at the interface, using energy-dispersive spectroscopy. The data were statistically analyzed using analysis of variance and the Tukey test (p < 0.05). Results: BD presented a higher bond strength than WMTA (p < 0.05). BD or WMTA in canals treated with calcium hydroxide intracanal medications had the highest bond strength values, with a statistically significant difference compared to TAP in the WMTA group (p < 0.05). There were small amounts of phosphorus in samples exposed to triple antibiotic paste, regardless of the coronal sealing. Conclusions: The use of intracanal medications did not affect the bond strength of WMTA and BD, except when TAP was used with WMTA.

Kinetic examination on synergistic effect of co-use of ultrasonic wave and ultraviolet radiation on bacterial disinfection in a household humidifier (초음파와 자외선(UV) 동시 적용이 가정용 가습기 내 살균에 미치는 시너지 효과에 대한 반응속도론적 연구)

  • Kim, Seunga;Kim, Jihyun;Lee, Minjoo;Kim, Jayun;Jung, Woosik;Park, Joonhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.3
    • /
    • pp.227-235
    • /
    • 2021
  • This study examined the effect of ultraviolet (UV) application on bacterial disinfection in a commercialized humidifier using ultrasonic wave (UW). To accurately examine disinfection kinetics in tap-water condition, tap-water was sterilized using a filter, and then inoculated with pure cultures of E. coli and P. putida with known viable counts. The disinfection kinetic characteristics were experimentally compared when UV alone, UW alone, and UW+UV together were applied in disinfecting the added bacteria in the commercialized humidifier. When UV alone was applied, bacterial disinfection kinetics followed a first-order decay reaction, and showed an approximately 10-time weaker disinfection compared to the typical UV disinfection in water treatment or wastewater treatment. When UW alone was applied, bacterial disinfection kinetics followed a second-order decay reaction with a low disinfection rate constant of 0.0002 min-1(CFU/mL)-1. When UV and UW were applied together, however and interestingly, the disinfection rate constant (0.0211 min-1(CFU/mL)-1) was approximately 100 times increased than that for the UW alone case. These results revealed that the co-use of UV and UW can provide synergistic effect on bacterial disinfection in a tap-water condition in household humidifiers.

Clinical study of myocardial preservation (심근보호에 대한 임상적 고찰)

  • Jo, Jae-Il;Lee, Yeong-Gyun
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.557-564
    • /
    • 1984
  • Of the valve replacement patients operated between 1983 and June, 1984, 75 patients need more than 60 minutes of aortic cross-clamping time. 42 patients performed single valve replacement [35 MVR, 7 AVR with or without TAP] and remainder needs double valve replacement with or without TAP. The average aortic clamping time was 95.1 minutes. They need 30 minutes more extra-corporeal circulation time than aortic clamping time. The patients were divided into two groups by usage of cardioplegic solution. Group I [n=31] with Bretschneider solution and group II with potassium cardioplegic solution [M.G.H. modification] were analyzed by extra-corporeal circulation data,/CG and Echocardiography findings, and clinical data. There was no difference between two groups in Bivon addition amounts [cc/kg] and E.F. and S.F. by echocardiography, group I need 1 more electrocardioversion to convert sinus rhythm postoperatively. Also no difference could be found in patients whose preoperative C.I. was above 2.0 between two group. But significant postoperative decrease in E.F. was found in group I whose preoperative C.I. was below 2.0. Relatively longer ECC time was also needed in same group. Ischemic changes in ECG and low cardiac output syndrome was, however more prevalent in groupII. As a whole, the clinical data was satisfactory with both cardioplegic solution in clinical practice.

  • PDF

Discrimination of the drinking water taste by potentiometric electronic tongue and multivariate analysis (전자혀 및 다변량 분석법을 활용한 먹는물의 구별 방법)

  • Eunju Kim;Tae-Mun Hwang;Jae-Wuk Koo;Jaeyong Song;Hongkyeong Park;Sookhyun Nam
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.425-435
    • /
    • 2023
  • Organoleptic parameters such as color, odor, and flavor influence consumer perception of drinking water quality. This study aims to evaluate the taste of the selected bottled and tap water samples using an electronic tongue (E-tongue) instead of a sensory test. Bottled and tap water's mineral components are related to the overall preference for water taste. Contrary to the sensory test, the potentiometric E-tongue method presented in this study distinguishes taste by measuring the mineral components in water, and the data obtained can be statistically analyzed. Eleven bottled water products from various brands and one tap water from I city in Korea were evaluated. The E-tongue data were statistically analyzed using multivariate statistical tools such as hierarchical clustering analysis (HCA), principal component analysis (PCA), and partial least squares discriminant analysis (PLS-DA). The results show that the E-tongue method can clearly distinguish taste discrimination in drinking water differing in water quality based on the ion-related water quality parameters. The water quality parameters that affect taste discrimination were found to be total dissolved solids (TDS), sodium (Na+), calcium (Ca2+), magnesium (Mg2+), sulfate (SO42-), chloride (Cl-), potassium (K+) and pH. The distance calculation of HCA was used to quantify the differences between 12 different types of drinking water. The proposed E-tongue method is a practical tool to quantitatively evaluate the differences between samples in water quality items related to the ionic components. It can be helpful in quality control of drinking water.

5-Tap Adaptive PRML Architecture for High-Density Optical Disc Channel

  • Choi, Goang-Seog
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.12
    • /
    • pp.1585-1590
    • /
    • 2007
  • This paper introduces adaptive PRML (Partial Response Maximum Likelihood) architecture with PR (a,b,c,d,e) channel type for the improved readability of high-density optical discs with capacity greater than 30GB. The proposed PRML architecture consists of an adaptive equalizer, a Viterbi detector and a channel identifier. Detailed description for each component is included. The architecture is implemented in chip and also confirmed its performance on the test board mounting the chip. Test results show that the proposed 5-tap PRML architecture is well operated, and less than $2{\times}10^{-4}$ of BER (Bit Error Rate) is achieved with radial and tangential tilt margin of ${\pm}0.6^{\circ}$ on self-made 30GB BD at 1x speed.

  • PDF

The Behavior of a $CO_2$Fixation Process by Euglena Gracilis Z with a Photobioreactor (광반응기와 Euglena gracilis Z를 이용한 이산화탄소 고정화 공정의 거동 특성)

  • 신항식;채소용;황응주;임재림;남세용
    • KSBB Journal
    • /
    • v.15 no.6
    • /
    • pp.644-648
    • /
    • 2000
  • Biological fixation of carbon dioxide using microalgae is known as an effective CO$_2$reduction technology. However, many environmental factors influence microalgal productivity. Optimal cultivation factors were determined for the green alga, Euglena gracilis Z, which offers high protein and vitamin E content for animal fodder. In batch culture in a photovioreactor, it was found that theinitial pH, temperature, CO$_2$concentration in air, and light intensity during the optimal cultivating conditions were 3.5, 27$^{\circ}C$, 5-10% and 520 ${\mu}$mol/㎡/s, respectively. When tap water and freshwater were used as cultivating media unsterilized tap water was found to be effective. A kinetic model was considered to determine the relationship between the specific growth rate and the light intensity. The half-velocity coefficient (K(sub)I) in the Monod model under photoautotrophic conditions was 978.9 ${\mu}$mol/㎡/s.

  • PDF

Corrosion control technology in water pipes by adjusting the corrosivity of drinking water : effect and impact of the lime dispersion system (수돗물 부식성 제어를 통한 수도관 부식방지기술: 석회수 분산화장치를 이용한 미네랄 공급 효과와 영향 분석)

  • Han, Keum-Seok;Park, Young-Bok;Kim, Seong-Jae;Kim, Hyen-Don;Choi, Young-June;Park, Ju-Hyun;Woo, Dal-sik;Hong, Seong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.3
    • /
    • pp.235-242
    • /
    • 2018
  • Corrosion inhibitors including calcium hydroxide have been used to prevent corrosion in the pipes for tap water supply. The corrosion index (i.e., Langelier Index) differs by area and water quality. The corrosion indices of the areas studied differed by more than 2.0. The 'homogenized' calcium hydroxide was added to the treated water at the K water treatment plant, in order to increase the value of the corrosion index and the concentration of calcium. As the result, the concentration of calcium was increased while the turbidity and pH changed little. The corrosion rate of the tap water with the 'homogenized' calcium hydroxide could be slowed down pretty much. The results suggested that the technology of 'homogenization' of calcium hydroxide can applied to tap water and desalinated water to prevent corrosion in water pipes even in corrosive pipes.

Analysis of Factors and it's Effectiveness to Maintenance Cost of Public Buildings (공공청사의 운영비용에 영향을 미치는 요인과 요인별 영향력 분석)

  • Ko, Kyujin;Cho, Sangouk;Hwang, Jeongha;Lee, Chansik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.2
    • /
    • pp.29-37
    • /
    • 2015
  • Multi-household buildings are efficiently maintained from the mid- and long-term viewpoint according to the long-term repair coverage system etc. On the other hand, public buildings are not systematically maintained due to a lack of past maintenance cost data and inefficient budget plans, among other problems. Targeting public buildings in Incheon, this study analyzed operation costs variables. To verify the analysis results, they underwent a correlation analysis and a multi-regression analysis. With regard to public buildings electricity, gas and tap water cost, the influence power of the served life, floor area, and workforce were analyzed, revealing that electricity cost was highly correlated with workforce, while gas and tap water cost were correlated with tap water cost. Also, the correlation analysis results were verified through a multi-regression analysis, and a maintenance cost estimation model was presented using a regression equation.

Operating Characteristic of a User Defined Distance Relay Model in PSS/E during Voltage Instability (전압 불안정시 PSS/E 사용자 정의모델로 구현된 거리계전기 응동 특성)

  • Lee, D.G.;Kang, S.H.;Yang, J.J.;Oh, H.W.;Jang, B.T.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.82-84
    • /
    • 2003
  • This paper presented a method to develop a relay model by the user-written model function of PSS/E. As for the voltage instability, although generator current limiters, transformer's tap-changers and dynamic loads have been considered as the dominant components, the protection system is also very important because it may influence the system's dynamic behaviour. Hence a distance relay model implemented with the suggested method was added, and then the operating characteristics of the distance relay under the voltage instability condition were investigated.

  • PDF

Performance Evaluation and Convergence Analysis of a VEDNSS LMS Adaptive Filter Algorithm

  • Park, Chee-Hyun;Hong, Kwang-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.2E
    • /
    • pp.64-68
    • /
    • 2008
  • This paper investigates noise reduction performance and performs convergence analysis of a Variable Error Data Normalized Step-Size Least Mean Square(VEDNSS LMS) algorithm. Adopting VEDNSS LMS results in higher system complexity, but noise is reduced providing fast convergence speed Mathematical analysis demonstrates that tap coefficient misadjustment converges. This is confirmed by computer simulation with the proposed algorithm.