• Title/Summary/Keyword: E-J power

Search Result 823, Processing Time 0.025 seconds

A 3-5GHz frequency band Programmable Impulse Radio UWB Transmitter (3-5 GHz 대역 중심 주파수 변환이 가능한 프로그래머블 임펄스 래디오 송신기)

  • Han, Hong-Gul;Kim, Tae-Wook
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.6
    • /
    • pp.35-40
    • /
    • 2012
  • This paper has proposed a 3~5 GHz IR-UWB low power transmitter for range detection application. Proposed transmitter which has been implemented in a $0.13{\mu}m$ CMOS technology is all digital circuit that consist of simple digital logic. this feature insure low complexity and low power consumption. In addition, center frequency can be changed by adopting voltage controlled delay cell for avoiding existing another radio frequency in UWB low band. Proposed circuit consume only 10pJ/b from 1.2 V supply voltage. The simulation results show 3.3~4.3 GHz center frequency controllability, -51 dBm/MHz maximum output power and is satisfied with FCC regulation.

Development of a HVHC-PEF Power Supply for Low Temperature Pasteurization (저온 살균용 펄스형 고압 대전류 전원장치 개발)

  • Yoo, D.W.;Kim, H.S.;Baek, J.W.;Ryoo, H.J.;Rim, G.H.;Pavlov, E.P.;Park, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2162-2164
    • /
    • 1997
  • High Voltage High Current Pulsed Electric Fields (HVHC-PEF) is a promising technology for the non-thermal pasteurization of foods and a sound complement or replacement to traditional thermal pasteurization, which inactivates bacteria and other microorganisms harmful to humans, but also degrades color, flavor, texture and nutrients. Foods can be pasteurized with pulsed electric fields at ambient or refrigerated temperatures for a short treatment time of seconds or less and the fresh-like quality of food is preserved. Although successful in laboratory tests, applying HVHC-PEF to food pasteurization on a large scale presents many unresolved engineering problems. In this paper the design considerations for 25kV 1kA class HVHC-PEF pasteurization equipment are analyzed and experimental results are discussed.

  • PDF

Development of high repetition rate and high power pulsed Nd:YAG laser power supply using ZCS resonant converter (ZCS공진형 컨버터를 적용한 고반복 대출력 펄스형 Nd:YAG 레이저 전원장치 개발)

  • Joe, K.Y.;Kim, E.S.;Byun, Y.B.;Kim, H.J.;Park, J.M.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.514-517
    • /
    • 1996
  • Zero current switching(ZCS) series resonant converter is used to control laser power density in a pulsed Nd:YAG laser power supply. The high power and high repetition rate paused Nd:YAG laser is designed and fabricated to control current pulse width and pulse repetition rate in the double elliptical laser oscillator. In order to find out operational characteristics of pulsed Nd:YAG laser, the electrical properties of driving power supply and laser output power are investigated and experimented by changing of the current pulse width from 200uS to 350uS(step 50uS) and pulse repetition rate range of 500pps(pulse per second) to 1150pps. From that result, we obtaind maximum efficiency of 1.83% and maximum laser output or 220W at the condition of 350 uS and 1150pps with one Nd:YAG rod), and obtained that of more than 400W with two laser head connecting series.

  • PDF

A Study of EMI Solution for The Elevator Converter (엘리베이터용 컨버터의 EMI 대책에 관한 연구)

  • Kang, D.W.;Lee, G.H.;Lee, J.G.;Kim, H.S.;Jang, C.H.;Jeong, J.T.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2159-2161
    • /
    • 1997
  • This paper presents the investigations and the reduction methods for EMI in the Elevator(E/L) system. In the large capacity E/L. Power factor controlled IGBT converter is used, so that the conducted EMI level is mostly determined by a high frequency input current. We suggest the low cost EMI countermearsure for E/L system using by a LCL filter ed a low cost noise filter.

  • PDF

Development of N700E Invertor for Induction Motor drive (유도전동기 제어용 인버터 N700E 시리즈 개발)

  • Jeong, S.J.;Han, K.J.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.297-298
    • /
    • 2010
  • 산업용 인버터 시장은 부하의 운전 조건에 따라 고성능, 다기능, 단순 기능 분야로 구분된다. 당사는 고성능, 다기능 분야에 대응이 가능한 N700V 모델을 개발하여 영업 활동을 하고 있으나, 단순기능 분야에는 기능의 복잡성과 높은 가격 등으로 경쟁력이 저하되었다. 이에 당사는 단순기능 분야에 대응이 가능하도록 기능은 단순하고 가격경쟁력이 있는 맞춤형 인버터를 새로이 개발하게 되었다. 본 논문에서는 당사가 산업용 인버터 제품의 이원화를 위해 새로이 개발된 단순 기능형 인버터 N700E(5..5kW ~ 350kW) 시리즈에 대한 주요기능 및 성능에 대해 소개하고자 한다.

  • PDF

Performance Characteristics of Small Sized Cross-flow Cooling Tower (소형 직교류형 냉각탑의 성능 특성에 관한 연구)

  • Sarker, M.M.A.;Kim, E.P.;Kim, J.D.;Jun, C.H.;Moon, C.G.;Yoon, J.I.
    • Journal of Power System Engineering
    • /
    • v.9 no.2
    • /
    • pp.93-98
    • /
    • 2005
  • The performance of cooling tower is dependent on the thermal performance of the packings. It's assessed by heat transfer rate and fan power. In this study, new packing was developed for application in compact type cross-flow cooling tower. The packing characteristic curve and the pressure drop curve were obtained by measuring packing characteristic values and pressure drops of small sized filler in comparison to existing mid-large sized filler. The heat transfer characteristics on small sized filler are about 66% higher than existing mid-large sized filler. The pressure drop characteristics on small sized filler are about two times of the pressure drop characteristics on existing mid-large sized filler.

  • PDF

Sag-Swell Generator for Power Quality Disturbance of Dynamic UPS System (전력품질을 고려한 다이나믹 UPS 시스템의 Sag-Swell 발생기)

  • Ahn J.S.;Choi K.J.;Chun T.W.;Nho E.C;Kim I.D.;Kim H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.193-196
    • /
    • 2003
  • This paper describes a new Sag-Swell generator for the test of custom power devices such as UPS, DYR, DSTATCOM, 5575, etc. The proposed science has good features of simple structure, high reliability, wide range of Sag and Swell variation, and easy control. Outage, harmonic distortion, notches, and voltage unbalance also can be generated. The operation principle of the proposed scheme is described and verified through simulations.

  • PDF

Benefit/Cost Analysis with Power Market Simulation Software on The Transmission System Expansion (송전망확충의 경제성평가를 위한 전산모형 이용방안)

  • Moon, S.P.;Choi, Y.C.;Jang, B.H.;Kim, S.Y.;Yoon, J.S.;Lee, W.K.;Park, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.72-73
    • /
    • 2006
  • As the electric power market environments are being changed, suitable data for expansions should be subjected to stockholders. And the public responses are requested for transmission system expansion. The necessity of transmission system expansion can be easily assessed via the benefit/cost evaluations. Because the benefit/cost evaluation of the transmission system expansions required variety elements, which can be depended on electric power market simulation software. On this paper, a method is illustrated using the PPOOL developed by PPC and PSS/E developed by PTI.

  • PDF

A Current Differential Relaying Algorithm for Power Transformers Using an Advanced Compensation Algorithm of CTs (잔류자속에 무관한 전류보상 알고리즘을 적용한 변압기 보호용 전류차동 계전방식)

  • Kang, Y.C.;Lim, U.J.;Yun, J.S.;Jin, E.S.;Won, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.314-316
    • /
    • 2003
  • To prevent maloperation during magnetic inrush and over-excitation, a current differential relay for power transformers uses harmonic current based restraining or blocking scheme; it also uses dual slope characteristics to prevent maloperation for an external fault with CT saturation. This paper proposes a current differential relaying algorithm for power transformers with an advanced compensation algorithm for the secondary current of CTs. The comparative study was conducted with and without the compensating algorithm. The algorithm can reduce the operating time of the relay in the case of an internal fault and improve security for external faults.

  • PDF

A Study on Optimal Design of DC Substation Capacity for Mass Transit System (전철용 직류변전소의 최적용량설계에 관한 연구)

  • Kim, J.K.;Lee, S.D.;Baek, B.S.;Lee, H.D.;Lee, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1405-1407
    • /
    • 2000
  • This paper is on optimal design for DC substation capacity for Mass Transit System. Three factors are considered for the design i.e. substation arrangements, line configuration and substation power capacity. In this study, we discussed substation power capacity only. At first, DC-fed-traction system is introduced on an outline, a characteristics of train and fed network. Optimal design procedures is described, and modelling for DC-fed-traction system are presented. The circuit-solution method is presented by matrix formula. In order to simulate DC substation power capacity more closely to actual situations, we proposed the program.

  • PDF