• Title/Summary/Keyword: E-J power

Search Result 823, Processing Time 0.028 seconds

Development of a new CVAP structural analysis methodology of APR1400 reactor internals using scaled model tests

  • Jongsung Moon;Inseong Jin;Doyoung Ko;Kyuhyung Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.309-316
    • /
    • 2024
  • The U.S. Nuclear Regulatory Commission (NRC) Regulatory Guide (RG) 1.20 provides guidance on the comprehensive vibration assessment program (CVAP) to be performed on reactor internals during preoperational and startup tests. The purpose of the program is to identify loads that could cause vibration in the reactor internals and to ensure that these vibrations do not affect their structural integrity. The structural vibrational analysis program involves creating finite element analysis models of the reactor internals and calculating their structural responses when subjected to vibration loads. The appropriateness of the structural analysis methodology must be demonstrated through benchmarks or any other reasonable means. Although existing structural analysis methodologies have been proven to be appropriate and are widely used, this paper presents the development of an improved new structural analysis methodology for APR1400 reactor internals using scaled model tests.

Improved RPV(reactive-power-variation) anti-islanding method for grid-connected three-phase PVPCS (3상 계통연계형 태양광 PCS의 단독운전검출을 위한 개선된 무효전력변동기법)

  • Lee, K.O.;Jung, Y.S.;So, J.H.;Yu, B.G.;Yu, G.J.;Choi, J.Y.;Choy, I.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1159-1160
    • /
    • 2006
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, this has raised potential problems of network protection on electrical power system. One of the numerous problems is an Island phenomenon. There has been an argument that because the probability of islanding is extremely low it may be a non-issue in practice. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an island can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficient to cause a trip, plus the time required to execute the trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. And, third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an island. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. So the verification of anti-islanding performance is strongly needed. In this paper, the authors propose the improved RPV method through considering power quality and anti-islanding capacity of grid-connected three-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation and experimental results are verified.

  • PDF

Experimental Study on Turbulence and Pressure Drop Characteristics in a Rectangular Duct Fitted with Semicircular Ribs (반원 리브의 거칠기를 가진 사각덕트에서의 난류 및 마찰 특성에 관한 실험적 연구)

  • Nine, Md.J.;Lee, G.H.;Woo, J.S.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.15 no.5
    • /
    • pp.43-48
    • /
    • 2011
  • The article represents an experimental investigation on friction and turbulent flow characteristics of free airflow through a rectangular duct fitted with semicircular ribs of uniform height (e = 3.5 mm) on one principle wall. The aspect ratio of the rectangular duct was AR= 5 where the duct height (H) was of 30 mm. Four different rib pitches (P) of 28 mm, 35 mm, 42 mm and 49 mm were used for constant rib height to hydraulic diameter ratio (e/Dh = 0.07) and constant rib height to channel height ratio (e/H = 0.11). The experimental results show some significant effects on pressure drop as well as turbulent characteristics at various configurations among different numbers of rib arrangements varying Reynolds number in the range of 15000 to 30000. Pressure transducer and hot wire anemometer were used for data acquisition of this experiment.

A Study on Improvement of the Speed Regulation in a Gas Turbine Control (발전기 출력의 계통주파수 추종성 향상에 관한 연구)

  • Kim, J.A.;Byun, S.H.;Kim, E.G.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.639-641
    • /
    • 1997
  • 전력계통의 주파수는 전력의 수요와 공급량의 평형상태에 따라 수시로 변동하며, 각 발전소에서는 이 주파수를 입력 신호로 사용하여 발전기의 출력을 제어하고 있다. 본 논문에서는 국내에서 운영하고 있는 한 개스터빈 발전소의 터빈제어 시스템을 모델로 하여 주파수 추종성에 영향을 미치는 파라미터들을 분석하고, 시뮬레이션을 통해 주파수 추종성을 향상시키기 위한 방안을 제시하였으며, 현장에 적용한 결과를 통해 제안된 주파수 추종성 향상방안의 타당성을 검증하였다.

  • PDF

A Study on the application of Smith Predictor (Smith Predictor의 적용에 관한 연구)

  • Byun, S.H.;Lee, C.J.;Kim, E.G.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.642-644
    • /
    • 1997
  • 프로세스에서의 시간지연은 프로세스의 제어에 있어서 어려움을 초래하며, 시스템의 성능저하의 원인이 되고 있다. 이러한 프로세스의 시간지연을 극복하고자 해서 제안된 제어기의 구조가 기존의 제어기에 smith predictor를 결합한 형태이다. 본 논문에서는 몇 개의 프로세스를 선택하고, PI 제어기와 smith predictor와 결합되어진 PI 제어기에 대해서 프로세스의 지연시간에 따른 컴퓨터 모의실험을 통해 smith predictor의 효용성을 논하고자 한다.

  • PDF

Effects of Low Power Laser on Pain Response and Axonal Regeneration in Rat Models with Sciatic Nerve Crush Injury

  • Lee, Hong-Gyun;Kim, Yong-Eok;Min, Kyung-Ok;Yoo, Young-Dae;Kim, Kyung-Yoon;Kim, Gye-Yeop
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.3 no.1
    • /
    • pp.345-355
    • /
    • 2012
  • This study purposed to examine the effect of low power laser on pain response and axonal regeneration. In order to prepare peripheral nerve injury models, we crushed the sciatic nerve of Sprague-Dawley rats and treated them with low power laser for 21 days. The rats were divided into 4 groups: normal group(n=10); control group(n=10) without any treatment after the induction of sciatic nerve crush injury; experimental group I(n=10) treated with low power laser(0.21$mJ/mm^2$) after the induction of sciatic nerve crush injury; and experimental group II(n=10) treated with low power laser(5.25$mJ/mm^2$) after the induction of sciatic nerve crush injury. We measured spontaneous pain behavior(paw withdrawal latency test) and mechanical allodynia(von Frey filament test) for evaluating pain behavioral response, and measured the sciatic function index for evaluating the functional recovery of peripheral nerve before the induction of sciatic nerve crush injury and on day 1, 7, 14 and 21 after the induction. After the experiment was completed, changes in the H & E stain and toluidine blue stain were examined histopathologically, and changes in MAG(myelin associated glycoprotein) and c-fos were examined immunohistologically. According to the results of this study, when low power laser was applied to rat models with sciatic nerve crush injury for 21 days and the results were examined through pain behavior evaluation and neurobehavioral, histopathological and immunohistological analyses, low power laser was found to affect pain response and axonal regeneration in both experimental group I and experimental group II. Moreover, the effect on pain response and axonal regeneration was more positive in experimental group I to which output 0.21$mJ/mm^2$ was applied than in experimental group II to which 5.25$mJ/mm^2$ was applied.

Design of an Inductive Coupler for Power Transmission line (송전선용 대용량 신호결합장치의 설계)

  • Kim, H.S.;Byun, W.B.;Kim, J.R.;Bae, E.R.;Lee, D.C.;Lee, H.Y.;Lee, J.H.;Ji, M.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.439-440
    • /
    • 2008
  • An inductive coupler, which feeds communication to the electric power transmission line, is required to establish Power Line Communication(PLC). The electro-magnetic property of magnetic core and design technology for coupler are very important to manufacture an inductive coupler for power transmission line. The magnetic core with superior electro-magnetic property was manufactured by using nano-crystalline alloy and an inductive coupler, which can operate at the maximum 2,000 A current, was designed and manufactured by establishment of current saturation, signal out winding, and electro-magnetic simulation in this study. Communication speed of 14 Mbps in 600 m communication distance of the real electric power transmission line was obtained by using the inductive coupler and application possibility of the inductive coupler for the electric power transmission line was certified.

  • PDF

Factors Affected the Accuracy of Lightning Current Measuring System (뇌격전류 측정의 정확도에 영향을 미치는 요인)

  • Lee, B.H.;Chang, K.C.;Kang, S.M.;Eom, J.H.;Jeong, K.J.;Sim, E.B.;Woo, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1674-1676
    • /
    • 2003
  • The factors affecting the accuracy of lightning current measuring system are figured out the materials and length of down-conductor, and impedance matching between grounding resistance and characteristic impedance of cable. The cable with the low characteristic impedance used to transfer the lightning current from the top of the tower is too long to measure the waveform of lightning current, exactly. Especially, the height of the tower can cause the change of front time and magnitude of lightning stroke current. Basically, in this experiment. It was found that the magnitude and rise time of the lightning current are extremely dependant in the length of down-conductor in lightning current measuring system.

  • PDF

A Study on the Reduction Factor of the Permissible Current-Carrying Capability of Underground Transmission Power Cables installed in Free Air (기중 다회선 부설에 대한 송전 케이블의 허용전류 저감계수에 관한 연구)

  • Jeong, S.H.;Kim, D.K.;Choi, S.B.;Lee, D.I.;Kang, J.W.;Gwak, B.M.;Tack, E.G.;Yoon, H.H.;Kim, J.S.;Park, J.H.;Kim, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.343-345
    • /
    • 2001
  • This paper calculates the reduction factors of JCS 168E standard and IEC pub 287-2-2 according to installing groups of cables in a tunnel in Korean, respectively. Also, this paper proposes a method fat calculating reduction factors for groups of cables in free air.

  • PDF

A Research for Current decreasing in 345 kV Power System (345 kV 계통전류 저감 대책)

  • Ju, H.J.;Kwak, J.S.;Kang, Y.W.;Shim, E.B.;Lee, B.S.;Pak, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.385-387
    • /
    • 2003
  • 전력계통의 증가에 따라 일부 계통에서 지락고장 전류가 2010년이후 차단기 정격전류인 40[kA]를 초과할 것으로 예상된다. 이에 대한 대책으로 345kV 변압기의 중성점의 부동(Floating) 운전을 위하여 PSS/E를 이용하여 실제의 발변전소의 모델을 설정하고 EMTP를 이용하여 지락고장 발생시 건전상의 전위상승, 중성점 전위상승, 부동운전 가능 대수, 변압기 중정점 NGR 설치 효과 및 적정 임피던스 산출, 변압기 중성점 피뢰기 설치 효과 및 적정 정격 산출등을 검토하였다.

  • PDF