• Title/Summary/Keyword: Dynamic transient analysis

Search Result 535, Processing Time 0.025 seconds

Simulation of Power IGBT and Transient Analysis (전력용 IGBT의 시뮬레이션과 과도 해석)

  • 서영수
    • Journal of the Korea Society for Simulation
    • /
    • v.4 no.2
    • /
    • pp.41-60
    • /
    • 1995
  • The IGBT(Insulated Gate Bipolar Transistor) is a power semiconductor device that has gained acceptance among circuit design engineers for motor drive and power converter applications. IGBT devices(International Rectifier, Proposed proposed model etc) have the best features of both power MOSFETs and power bipolar transistors, i.e., efficient voltage gate drive requirememts and high current density capability. When designing circuit and systems that utilize IGBTs or other power semiconductor devices, circuit simulations are needed to examine how the devices affect the behavior of the circuit. The interaction of the IGBT with the load circuit can be described using the device model and the state equation of the load circuit. The voltage rise rate at turn-off for inductive loads varies significantly for IGBTs with different base life times, and this rate of rise is important in determing the voltage overshoot for a given series resistor-inductor load circuit. Excessive voltage overshoot is potentially destructive, so a snubber protection circuit may be required. The protection circuit requirements are unique for the IGBT and can be examined using the model. The IGBT model in this paper is verified by comparing the results of the model with experimented results for various circuit operating conditions. The model performs well and describes experimented results accurately for the range of static and dynamic condition in which the device is intended to be operated.

  • PDF

Analysis of Fuel/Coolant Mixing in Steam Explosion (증기 폭발시 용융 핵연료/냉각수 혼합에 대한 해석)

  • Lee, Tae-Ho;Jo, Seong-Youn;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.215-221
    • /
    • 1993
  • A required initial condition for a steam explosion to occur following core meltdown accidents of a nuclear power plant is the formation of a coarse mixture of molten fuel and water. The extent of a premixing is the measure of efficiency of steam explosion that may follow. A simple one-dimensional, transient model and the flooding criteria have been applied to evaluate the fuel/coolant mixing limit. Also, both instant breakup and dynamic breakup models for the mixing process have been separately used here and compared each other. The results indicate that fuel temperature, ambient pressure, mixing diameter, water depth, and pouring diameter are the important parameters affecting the mixing behavior.

  • PDF

Modern Characteristics of Victor Horta's Domestic Architecture (빅터 호르타의 주택설계에 나타난 근대적 특성에 관한 연구)

  • Hwangbo, A.B.
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.73-80
    • /
    • 2009
  • In the early twentieth century, many architects still practised eclectic design elements. Emergence of new building materials such as steel, concrete and glass were not yet found fresh roles in architectural design. It was Brussels that the use of modern materials gave rise to their new forms and gave influence to not only building skins but also spatial organization. Art Nouveau architecture is often seen as revolutionary and pioneering modern architecture against eclectic classicism prevalent in the 18th and 19th centuries. Despite the fact that some scholars point out that Art Nouveau is more a transient phenomenon than modern architecture proper, no one would deny that Art Nouveau carries a good deal of modern characteristics. This paper intends to show rather ambivalent perspectives upon Art Nouveau architecture. Although it insinuates overly dynamic nature in architectural languages, it does not hamper us from reading Art Nouveau as a vital component of modern architecture. Through a careful analysis of the early domestic designs of Victor Horta, it becomes evident that his work can provide modern architecture a meaningful alibi for its growth. Victor Horta's house design is well known to the public, both for his classical tastes and for its changing implementation. Horta's modern quality is never adequately recognized, partly due to his eye catching modern iron properties and sinuous ornamentation. This paper tries to offer an insight into the complicated stage set of the fin-de-$si{\grave{e}}cle$ through the work of Victor Horta whose influence has been immense in the making of modern architecture.

Vibration Analysis of Flexible Rotor Having a Breathing Crack (개폐균열이 존재하는 유연 회전체의 진동해석)

  • Jun, Oh-Sung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.10 s.103
    • /
    • pp.1137-1147
    • /
    • 2005
  • The dynamic response due to the unbalance and crack and the quasi-static response due to gravity are analytically derived based on the complex transfer matrix. The additional slope is expressed as function of the bending moment at crack position based on the fracture mechanics concept, and inversely the bending moment is expressed as function of the additional slope at the crack Position. At each angle step during the shaft revolution, the additional slope and bending moment are calculated by an iterativemethod. The transient behavior is considered by introducing Fourier series expansion concept for the additional slope. Simulation is carried out for a simple rotor similar to those available in the literature and comparison of the basic crack behavior is shown. Using the additional slope, the cracked rotor behavior is explained with the crack depth increased: the magnitude of the additional slope increases and the closed crack duration during a revolution decreases as the crack depth increases. The direction of unbalance is also shown as a factor to affect the crack breathing. Whirl orbits are shown near the sub-critical speed ranges of the rotor.

The Analysis Study on Supplying Heat by Various Control Methods in District Heating System (지역난방 시스템에서 제어방법에 따른 공급열량의 해석적 연구)

  • Kim, Seong-Su;Jung, Sang-Hum;Moon, Youn-Jin;Cho, Sung-Hwan;Ryu, Jae-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1008-1013
    • /
    • 2009
  • The theoretical simulation to predict the variation of supplying heat according to control methods of DHS(District Heating System) have been done by TRNSYS(A Transient System Simulation Program) 16. The physical system for DHS consists of primary and secondary supplying heating loop which is divided by based on heat exchanger for heating demand of building. The simulation results showed that control of secondary supplying heat had influenced more than primary supplying heat control to total energy consumption of DHS. And the outside temperature reset control of primary supplying heating loop could be reduced until about 4% overheating of each zone.

  • PDF

The Effective Heating Control Method of the Radiant Floor Heating System (바닥복사 난방공간의 효율적인 난방제어방법)

  • Cho, S.H.;Tae, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.317-329
    • /
    • 1996
  • By describing the floor slab of a radiant heating system as a one dimensional transient heat exchanger problem, a dynamic analysis model to incorperate with TRNSYS program was developed and their results were compared with experimental results. Results showed that the both of TPOC(Two Parameter On-off Control) and TPSC(Two Parameter Switching Control) method using room air temperature and floor surface temperature as the control parameters does not maintain room air and floor surface temperature exactly at the setting temperatures. But TPSC method is a better candidate for the temperature regulations of room air and floor surface temperature than TPOC method which can keep on the upper and lower limit temperature according to outside temeperature and wall structure etc. And better thermal circumstance can be given by TPSC method than On-off and TPOC method and the overheating which can be occured at the radiant floor heating system with on-off heating control will be reduced.

  • PDF

Electro-thermal Feedback Effects on the Signal in a Pulse Voltage Biased μ-bolometer Focal Plane Array (마이크로 볼로미터 초점면 배열에서 전기-열적 피드백 현상이 신호에 미치는 영향)

  • Park, Seung-Man;Han, Seungoh
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1886-1891
    • /
    • 2012
  • In this paper, the analytical models for the electrothermal feedback of a ${\mu}$-bolometer focal plane array(FPA) are proposed and applied to the conceptually designed FPA to investigate the electrothermal feedback effect on bolometer FPA signal. The temperature and resistance change of the ${\mu}$-bolometer by the electrothermal feedback(ETF) model are increased upto 20 and 35.7 % of those of no feedback case, respectively, while those by the effective thermal conductance(ETC) model increased 8.5 and 15.1 %. The integration current and output voltage of a CTIA used as an column amplifier of FPA are also increased upto 41.6 and 32.4 % by the ETF model, while increased upto 17.2 and 13.5 % by the ETC model. The proposed models give more accurate temperature change, accordingly larger signal than no feedback considering case. Electrothermal feedback effect should be considered to design a high performance and high density ${\mu}$-bolometer FPA. The proposed models are very useful to investigate the transient thermal analysis, also considered to be useful to predict the responsivity and dynamic range of ${\mu}$-bolometer FPAs.

The New Voltage Event Detection Method and Control System Design for DVR Applied to 22.9kV Distribution System (22.9kV 배전선로 적용을 위한 DVR의 새로운 외란검출 기법 및 제어시스템 설계)

  • Kim H.J.;Chung Y.H.;Kwon G.H.;Park T.B.;Moon J.I.;Jeon Y.S.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • This paper proposes the new voltage event detection method using the weight factor of neural network and describes control system design for the DVR(Dynamic Voltage Restorer) consisted of a rectifier and series inverter applied to 22.9kV distribution system. As this method can express the fault level of each phase, we expect the proposed method can make up for disadvantage of synchronous detection method. Also, in this paper, the control system was designed using double deadbeat controller, As it has an inner current control loop and an outer voltage control loop, we can easily limit the current level during the transient intervals by using the current control loop. Simulation and experiment are performed to prove the analysis of the voltage event detection method and double deadbeat controller.

A study on the Structural Stability about the Fan Blade by the Air Excited Forces. (공기 가진력에 의한 팬 블레이드 구조 안정성 평가에 관한 연구)

  • 정규강;김경희;조생현
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.1
    • /
    • pp.93-101
    • /
    • 2000
  • In a gas-turbine engine, fan blades in flow path are confronted with many kinds of loading. The study of the excited force by the wake of struts has proposed and the possibility of fatigue failure about rotating fan blades by the excited force at the steady state is evaluated. Equations of the excited force of wakes has been derived at the steady state and the maximum pressure distributions measured at the transient state are proposed. Dynamic characteristics and the fatigue strength of fan blades by experimental test were obtained. To evaluate HCF(High Cycle Fatigue) damage of fan blades, FEM analysis was performed with a steady state harmonic response, which was followed by high cycle fatigue damage factor from goodman diagram.

  • PDF

Diagnostics of nuclear reactor coolant pump in transition process on performance and vortex dynamics under station blackout accident

  • Ye, Daoxing;Lai, Xide;Luo, Yimin;Liu, Anlin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2183-2195
    • /
    • 2020
  • A mathematical model for the flowrate and rotation speed of RCP during idling was established. The numerical calculation method and dimensionless method were used to analyze the flow, head, torque and pressure and speed changes under idle conditions. Regularity, using the Q criterion vortex identification judgment method combined with surface flow spectrum morphology analysis to diagnose the vortex dynamic characteristics on RCP blade. On impeller blade, there is two oscillations in the pressure ratio on pressure surface in blade outlet region. The velocity on the suction surface is two times more oscillating than the inlet of blade, and there is an intersection with the velocity ratio curve on pressure surface. On blade of guide vane, the pressure ratio increases along the inlet to outlet direction, and the speed ratio decreases with the increase of idle time. There is a vortex that rotates counterclockwise on the suction surface, and the streamline on the suction surface of blade is subjected to the entrainment and blocking action of the vortex creates a large reverse flow in the main flow region. There are two vortices at the outlet of guide vane suction side and the vortices are in opposite directions.