• 제목/요약/키워드: Dynamic tissue perfusion

검색결과 9건 처리시간 0.019초

교대부양 설정압력 변화가 인체조직의 동적인 관류특성에 미치는 영향 (The Effects of Alternating Set Pressure Changes on Dynamic Tissue Perfusion Characteristics)

  • 원병희;송창섭
    • 대한인간공학회지
    • /
    • 제29권6호
    • /
    • pp.875-887
    • /
    • 2010
  • The quantitative effectiveness of powered support surfaces such as APAM in preventing and treating pressure ulcers has not been sufficiently evaluated because of uncertainty of alternating pressure load input and lack of interpretation of dynamic perfusion characteristics of soft tissue. The aim was to verify the dynamic loading effects to sacral tissue perfusion characteristics from alternating set pressure changes. We developed integrated experiment system to supply alternating load to supinely positioned sacrum and concurrently measured $TcPO_2$, $TcPCO_2$ and air cell pressure. Ten aged subjects (5 female, 5 male) were tested with alternating set pressure 20, 30, 40, 50 and 60mmHg. From the dynamic perfusion response eight characteristic parameters were proposed such as average, minimum, maximum and perfusion range regarding to $TcPO_2$ and $TcPCO_2$. A one-way ANOVA was carried out to determine whether the manipulation of alternating set pressure had any effect on $TcPO_2$ and $TcPCO_2$. From the dynamic tissue perfusion response we found mean $TcPO_2$ decreased exponentially as alternating pressure load increased and perfusion range varied mainly because of minimum level change of $TcPO_2$. And perfusion range of $TcPCO_2$ affected by increase of maximum value of $TcPCO_2$. From the results we can get more strict insights about actual physiological dynamic tissue perfusion mechanism under alternating pressure load.

Dynamic Susceptibility Contrast Magnetic Resonance Images를 이용한 뇌혈류량 지도 구성 (Cerebral Blood Volume Mapping from Dynamic Susceptibility Contrast Magnetic Resonance Images)

  • 김수정;이선규;김광기;김종효;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.281-282
    • /
    • 1998
  • Recently, there has been growing interest in the assessment of physiological parameters on brain perfusion that provide more information than pure morphologic diagnosis. Quantification of parameters that characterize cerebral micro-circulation with magnetic resonance imaging is of great relevance for clinical application. We determine the local tissue concentration by exponential relationship between the relative signal reduction S(t)/$S_0$ and local tissue concentration of contrast material $C_m(t)$ in dynamic susceptibility contrast enhanced MR imaging. And then we made relative regional blood volume map by calculating the area under the measured concentration-time curves $C_m(t)$ during first pass of paramagnetic contrast material as a preliminary step for perfusion map. These images make it possible to compare the rCBV in different brain regions in one individual at a time. We have it in contemplation to obtain arterial and brain signal time curves simultaneously to make absolute rCBV and perfusion (rCBF) map. These maps may provide the method of comparative investigations of different patients having strong variation in AIF.

  • PDF

Development of 3D Mapping Algorithm with Non Linear Curve Fitting Method in Dynamic Contrast Enhanced MRI

  • Yoon Seong-Ik;Jahng Geon-Ho;Khang Hyun-Soo;Kim Young-Joo;Choe Bo-Young
    • 한국자기공명학회논문지
    • /
    • 제9권2호
    • /
    • pp.93-102
    • /
    • 2005
  • Purpose: To develop an advanced non-linear curve fitting (NLCF) algorithm for dynamic susceptibility contrast study of brain. Materials and Methods: The first pass effects give rise to spuriously high estimates of $K^{trans}$ in voxels with large vascular components. An explicit threshold value has been used to reject voxels. Results: By using this non-linear curve fitting algorithm, the blood perfusion and the volume estimation were accurately evaluated in T2*-weighted dynamic contrast enhanced (DCE)-MR images. From the recalculated each parameters, perfusion weighted image were outlined by using modified non-linear curve fitting algorithm. This results were improved estimation of T2*-weighted dynamic series. Conclusion: The present study demonstrated an improvement of an estimation of kinetic parameters from dynamic contrast-enhanced (DCE) T2*-weighted magnetic resonance imaging data, using contrast agents. The advanced kinetic models include the relation of volume transfer constant $K^{trans}\;(min^{-1})$ and the volume of extravascular extracellular space (EES) per unit volume of tissue $\nu_e$.

  • PDF

동력형 욕창예방제품의 교대부양 압력 프로파 특성 (Alternating Pressure Profile Characteristics of Powered Pressure Ulcer Preventing Devices)

  • 원병희;송창섭
    • 대한인간공학회지
    • /
    • 제29권4호
    • /
    • pp.639-646
    • /
    • 2010
  • The APAM's quantitative effectiveness and comparative study in preventing and treating pressure ulcer has not been sufficiently evaluated mainly because of uncertainty of pressure load input and lack of interpretation of dynamic perfusion recovery characteristics of soft tissue. The purpose of this paper was to quantify and analyze the alternating pressure characteristics of APAM as a preventive measure for pressure ulcers. To quantify the alternating load to human body, we introduced alternating pressure profile concept and developed parametric model of the profile. Regarding pressure level and cycle time, 3 global and 7 local periodic parameters were used to define the profile such as light, standard, typical and heavy duty profile shape. Pressure impulse ratio of light duty is the lowest but pressure fluctuation is significantly high. For the same duty shape, contact conditions are changed with alternating cycle time and more dramatically in shorter alternating cycle time conditions. We can conclude that if we use shorter alternating cycle time on APAM's operation we can get more positive effects regarding to inflated contact time condition. We proposed the quantitative methods on tissue viability study of external loading by simultaneous measurement of interface pressure and tissue perfusion with proper alternating pressure profile conditions.

생체장기용 지지체 제작을 위한 박동형 탈세포화 장치의 박동성 평가 (Pulsatility Estimation of a Pulsatile Decellularizing Device for the Fabrication of Organ Scaffold)

  • 김동선;양세란;박성민;최성욱
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권2호
    • /
    • pp.62-73
    • /
    • 2017
  • To identify a solution for the restricted availability of healthy lungs and the high risk of immune rejections following organ transplantation, tissue engineering techniques for culturing lungs have been studied by many research groups. The most promising method for culturing lungs is the utilization of a bio-scaffold that was prepared using harvested organs from human donors or other animals by removing their original cells. In this study, a pulsatile perfusion pump was used to alleviate the cell removal effect with the high fluid-dynamic power of the perfusion stream during the decellularization process, while other conventional studies focused on chemical methods to identify efficient detergents. The purpose of this study was to analyze the developed device by using energy equivalent pressure (EEP), which is an indicator of pulsatility, to understand the characteristics of pulsatile energy transmitted according to the load size by using the artificial model and compare it with the measured EEP. The pulsatility of the device can be estimated with the concept of fluid-dynamic energy during a particular constant time period or fluid-dynamic power represented as EEP and EEP increment. Because the measured EEP of perfusion flow during decellularization can be changed by the amount of fluid leakage and the degree of clogging in the capillary vessels, EEP should be measured to determine whether the decellularization is progressing without problems. The decrement of EEP caused by the high perfusion resistance was observed from some experimental results that were obtained with artificial models. EEP can be used to monitor the decellularization process after analyzing the varying EEP according to the amount of load. It was confirmed that the EEP was maintained at a high level in the experiment using the harvested lungs from 12-13-week-old rats. In addition, it was confirmed that the cell removal time was faster than when continuous perfusion was performed. In this study, pulsatile power delivered to the lungs was measured to monitor the process of cell removal, and it serve as the evidence for efficient decellularization.

Rubidium-82 심근 Dynamic PET 영상과 이중적분법을 이용한 국소 심근 혈류 예측의 기본 모델 연구 (Regional Myocardial Blood Flow Estimation Using Rubidium-82 Dynamic Positron Emission Tomography and Dual Integration Method)

  • 곽철은;정재민
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권2호
    • /
    • pp.223-230
    • /
    • 1995
  • Rb-82 dynamic PET과 이중적분법에 의한 국소 심근 혈류측정 연구를 시행하고자 실험 개를 이용한 심근 경색 모델과 허혈성 심근질환에서 좌심실 입력함수에 의한 정상 및 관류결손 심근에서의 혈류를 측정하였다. 이중적분법이 선형회귀모델에 의한 혈류측정방법에 비하여 안정도가 높고 심근내혈류가 선형적인 가정을 배제할 수 있어 사용 가능한 방법이 될 수 있음을 확인하였다.

  • PDF

개에서 발생한 결장 평활근종에 대한 동적 컴퓨터 단층촬영 소견 1례 (Dynamic Computed Tomographic Characteristics of aColorectal Leiomyoma in a Dog)

  • 박노운;정욱헌;한재웅;엄기동
    • 한국임상수의학회지
    • /
    • 제32권2호
    • /
    • pp.200-204
    • /
    • 2015
  • 12년령 중성화 수컷 시추가 변비와 배변곤란 증상으로 내원하였다. 방사선 사진상 결장이 팽대되어 있으며 천추 수준에서 연부조직밀도의 종괴가 결장을 복측으로 압박하는 것이 관찰되었다. 컴퓨터 단층촬영상 종괴는 균일한 연부조직 정도의 감약성을 보이며 변연이 뚜렷하고 전이소견을 보이지 않았다. 동적 컴퓨터 단층촬영상 종괴는 촬영간 지속적인 낮은 조영증강을 보였으며 관류성 및 모세혈관 투과성은 둔부근육과 비교하여 낮은 것으로 평가되었다. 영상진단학적 검사상 종괴는 신생혈관 발달이 약한 골반강 내 양성 종양으로 잠정진단되었다. 종괴는 둔성분리를 통한 외과적 절제로 제거되었으며 조직검사결과 평활근종으로 진단되었다.

실험 개에서 Rb-82 심근 Dynamic PET 영상을 이용한 국소 심근 혈류 예측의 기본 모델 연구 (A Study on the Estimation of Regional Myocardial Blood Flow in Experimental Canine Model with Coronary Thrombosis using Rb-82 Dynamic Myocardial Positron Emission Tomography)

  • 곽철은;이동수;강건욱;황은경;정재민;장기현;정준기;이명철;서정돈;고창순
    • 대한핵의학회지
    • /
    • 제29권1호
    • /
    • pp.48-53
    • /
    • 1995
  • Rb-82 dynamic PET과 이중적분법에 의한 국소 심근 혈류측정 연구를 시행하고자 실험 개를 이용한 심근 혈전증 모델에서 좌심실 입력함수에 의한 정상 및 관류결손 심근에서의 혈류를 측정하였다. 이중적분법이 선형회귀모델에 의한 혈류측정방법에 비하여 실현이 간단하고 심근내 혈류가 선형적인 가정을 배제할 수 있어 더욱 정확한 방법이 될 수 있음을 확인하였다.

  • PDF

흡연자에서 관상동맥 내피세포 의존성 심근 혈류 예비능: $H_2^{15}O\;PET$ 찬물자극 검사에 의한 평가 (Evaluation of Endothelium-dependent Myocardial Perfusion Reserve in Healthy Smokers; Cold Pressor Test using $H_2^{15}O\;PET$)

  • 황경훈;이동수;이병일;이재성;이호영;정준기;이명철
    • 대한핵의학회지
    • /
    • 제38권1호
    • /
    • pp.21-29
    • /
    • 2004
  • 목적: 젊은 흡연자 및 비흡연자에서 찬물자극 후 심근혈류 예비능을 $H_2^{15}O\;PET$을 이용하여 측정한 후 비교함으로써 흡연에 의한 관상동맥 내피세포의 기능저하를 평가하고자 하였다. 대상 및 방법: 젊은 흡연자 9명($23.8{\pm}1.1$세; $6.6{\pm}2.5$ pack-years) 및 비흡연자 9명($23.8{\pm}2.9$세)에 대하여 안정상태 및 찬물자극 후, 그리고 아데노신 주입 중에 $H_2^{15}O$를 순간주사하고 동적 PET영상을 획득한 뒤, NMF 방법으로 입력 방사능곡선 및 조직 방사능곡선을 처리하여 심근혈류량을 산출하였다. 결과: 흡연자군 및 비흡연자군 사이에 심박수혈압곱 및 안정시 혈류량에는 유의한 차이가 없었다. 그러나, 찬물자극 자극 후에는 심근혈류가 흡연자군에서 비흡연자군에 비하여 유의하게 낮았으며(흡연자군 심근혈류 : $1.25{\pm}0.34$ ml/g/min, 비흡연자군 심근혈류=$1.59{\pm}0.29$ ml/g/min ; p=0.019), 특히 안정시 심근혈류에 대한 찬물자극 후의 심근혈류의 비(내피세포 기능에 의한 심근혈류의 예비능)도 흡연자에서 유의하게 낮았다(흡연자군=$90{\pm}24%$, 비흡연자군=$122{\pm}28%$ ; p=0.024). 한편, 아데노신 주입시의 심근혈류는 두군 간에 유의한 차이가 관찰되지 않았다(흡연자군 심근혈류=$5.81{\pm}1.99$ ml/g/min, 비흡연자군 심근혈류=$5.11{\pm}1.31$ ml/g/min ; p=NS). 결론: 젊은 흡연자에서 찬물자극 후에 $H_2^{15}O\;PET$을 이용하여 측정하여 산출한 심근혈류의 예비능이 젊은 비흡연자에 비하여 감소되어 있어서 흡연에 의한 관상동맥 내피세포의 기능장애를 확인할 수 있었다.