• 제목/요약/키워드: Dynamic steady-state

검색결과 680건 처리시간 0.028초

리니어모터 동특성 계측 및 인버터 성능분석 (The measurement of LIM dynamic characteristics and the analysis of the inverter performance)

  • 장석명;정상섭;이현구;김봉섭;정현갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.19-21
    • /
    • 1996
  • In this paper, the experiment on the dynamic characteristics of LIM for the propulsion system UTM(Urban Transit Maglev) is threated. Untill now LIM has been mainly experimented by using the rotational arch type system, but this system compose of the test vehicle mounted LIM, which driven by PWM inverter. And the anlysis of the performance and the steady-state characteristics of the LIM is treated under various operation patterns. This paper may be available to compose the operating system of LIM driven by the open or closed loop control.

  • PDF

벡터제어-구동 유도전동기의 파라미터 변동에 대한 비선형 제어특성의 해석 (Analysis of Nonlinear Control Characteristic for the Parameter Variation of Vector Control-Fed Induction Motors)

  • 손진근;석원엽;송양회;전희종
    • 전기학회논문지P
    • /
    • 제53권2호
    • /
    • pp.51-57
    • /
    • 2004
  • Vector control schemes are used in inverter-fed induction motor drives to obtain high performance. Crucial to the success of the vector control scheme is the knowledge of the instantaneous position of the rotor flux. However, the position of the rotor flux change with temperature and magnetic saturation of the motor. This variation cause deterioration of both steady state and dynamic operation of the motor drives. Performance degradation is in the form of input-output torque nonlinearity and saturation of the motor. Analytic expressions are derived to evaluate the effects due to parameter sensitivity. Also, dynamic response is shown by speed command with the variation of stator and rotor resistance.

용액형 유기반도체를 이용한 고성능 포토트랜지스터 (High Performance Organic Phototransistors Based on Soluble Pentacene)

  • 김영훈;이용욱;한정인;한상면;한민구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.79-80
    • /
    • 2007
  • A high performance organic phototransistor with dynamic range of 120 dB is demonstrated by employing soluble pentacene as a photo-sensing layer. The organic phototransistor used suspended source/drain (SSD) electrode structure, which provides a dark current level of ${\sim}10^{-14}$ A at positive gate bias. Under a steady-state illumination, the organic phototransistor exhibited a current modulation of $10^6$ compared to dark to give a dynamic range of 120 dB. These results suggest that the organic phototransistor based on TIPS pentacene can be a new premising candidate for low-cost and high-performance photo-sensing element for digital imaging applications.

  • PDF

An Enhanced Harmonic Voltage Compensator for General Loads in Stand-alone Distributed Generation Systems

  • Trinh, Quoc-Nam;Lee, Hong-Hee;Chun, Tae-Won
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.1070-1079
    • /
    • 2013
  • This paper develops an enhanced harmonic voltage compensator which is implemented with the aid of two repetitive controllers (RCs) in order to improve the output voltage performance of stand-alone distributed generation (DG) systems. The proposed harmonic voltage compensator is able to maintain the DG output voltage sinusoidal regardless of the use of nonlinear and/or unbalanced loads in the load side. In addition, it can offer good steady-state performance under various types of loads and a very fast dynamic response under load variations to overcome the slow dynamic response issue of the traditional RC. The feasibility of the proposed control strategy is verified through simulations and experiments.

Fast Transient Buck Converter Using a Hysteresis PWM Controller

  • Liu, Yong-Xiao;Zhao, Jin-Bin;Qu, Ke-Qing
    • Journal of Power Electronics
    • /
    • 제13권6호
    • /
    • pp.991-999
    • /
    • 2013
  • In this paper, a fast transient buck converter using hysteresis PWM control is presented. The proposed control method is based on hysteresis control of the capacitor C voltage. This offers a faster transient response to meet the challenges of the power supply requirements for fast dynamic input and load changes. It also provides better stability and solves the compensation problem of the error amplifier in conversional voltage PWM control. Finally, the steady-state and dynamic operation of the proposed control method are analyzed and verified by simulation and experimental results.

Performance Improvement of Model Predictive Control Using Control Error Compensation for Power Electronic Converters Based on the Lyapunov Function

  • Du, Guiping;Liu, Zhifei;Du, Fada;Li, Jiajian
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.983-990
    • /
    • 2017
  • This paper proposes a model predictive control based on the discrete Lyapunov function to improve the performance of power electronic converters. The proposed control technique, based on the finite control set model predictive control (FCS-MPC), defines a cost function for the control law which is determined under the Lyapunov stability theorem with a control error compensation. The steady state and dynamic performance of the proposed control strategy has been tested under a single phase AC/DC voltage source rectifier (S-VSR). Experimental results demonstrate that the proposed control strategy not only offers global stability and good robustness but also leads to a high quality sinusoidal current with a reasonably low total harmonic distortion (THD) and a fast dynamic response under linear loads.

Dynamic Modeling-based Flight P-PD Controller Applied to a Quadrotor

  • Jin, Tae-Seok
    • 한국산업융합학회 논문집
    • /
    • 제25권4_1호
    • /
    • pp.513-519
    • /
    • 2022
  • In this paper, we describe performances of P-PD controllers in the quadrotor system with steady-state error compensation by adding a corrective term to the system input. A decentralized control system using P-PD controllers was successfully implemented on a quadrotor platform. We also presented the results of a mathematical modeling analysis for control the quadrotor and experimental results for each response performance according to the heading reference value in accordance with the mathematical modeling and P-PD controller design. A control experiment with the real system was implemented for the test platform, and the results were evaluated and compared.

The nonlinear fuzzy intelligent theory for high-bypass-ratio two-spool unmixed-flow jet engines

  • C.C. Hung;T. Nguyen
    • Advances in aircraft and spacecraft science
    • /
    • 제10권4호
    • /
    • pp.369-391
    • /
    • 2023
  • In our research we have offered a solid solution for aeronautical analysis. which can guarantee the asymptotic stability of coupled nonlinear facilities. According to the theoretical solutions and methods presented, the engine of this aircraft is a small high-bypass turbofan engine. using the non-linear aero-motor control approach and this paper focuses on the power management function of the aero-motor control system. These include static controls and transient controls. A mathematical model of the high-bypass-ratio two-spool unmixed-flow aeroengine was developed through a set of nonlinear dynamic equations verified by experimental data. A single actuator using the displacement method is designed to maintain a certain level of thrust under steady-state conditions. and maintains repeatable performance during transient operation from the requested thrust phase to the next. A single controller can compensate for the effects of noise and harmonic noise at many performance points. And the dynamic performance of a single controller is satisfactory during the transient. for fairness Numerical and computer experiments are described in the perfection of the methods we offer in research.

Deadbeat Control with a Repetitive Predictor for Three-Level Active Power Filters

  • He, Yingjie;Liu, Jinjun;Tang, Jian;Wang, Zhaoan;Zou, Yunping
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.583-590
    • /
    • 2011
  • Three-level NPC inverters have been put into practical use for years especially in high voltage high power grids. This paper researches three-level active power filters (APFs). In this paper a mathematical model in the d-q coordinates is presented for 3-phase 3-wire NPC APFs. The deadbeat control scheme is obtained by using state equations. Canceling the delay of one sampling period and providing the predictive value of the harmonic current is a key problem of the deadbeat control. Based on this deadbeat control, the predictive output current value is obtained by the state observer. The delay of one sampling period is remedied in this digital control system by the state observer. The predictive harmonic command current value is obtained by the repetitive predictor synchronously. The repetitive predictor can achieve a better prediction of the harmonic current with the same sampling frequency, thus improving the overall performance of the system. The experiment results indicate that the steady-state accuracy and the dynamic response are both satisfying when the proposed control scheme is implemented.

Finite Control Set Model Predictive Control of AC/DC Matrix Converter for Grid-Connected Battery Energy Storage Application

  • Feng, Bo;Lin, Hua
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.1006-1017
    • /
    • 2015
  • This paper presents a finite control set model predictive control (FCS-MPC) strategy for the AC/DC matrix converter used in grid-connected battery energy storage system (BESS). First, to control the grid current properly, the DC current is also included in the cost function because of input and output direct coupling. The DC current reference is generated based on the dynamic relationship of the two currents, so the grid current gains improved transient state performance. Furthermore, the steady state error is reduced by adding a closed-loop. Second, a Luenberger observer is adopted to detect the AC input voltage instead of sensors, so the cost is reduced and the reliability can be enhanced. Third, a switching state pre-selection method that only needs to evaluate half of the active switching states is presented, with the advantages of shorter calculation time, no high dv/dt at the DC terminal, and less switching loss. The robustness under grid voltage distortion and parameter sensibility are discussed as well. Simulation and experimental results confirm the good performance of the proposed scheme for battery charging and discharging control.