• Title/Summary/Keyword: Dynamic snapping

Search Result 28, Processing Time 0.024 seconds

Dynamic Stability and Semi-Analytical Taylor Solution of Arch With Symmetric Mode (대칭 모드 아치의 준-해석적 테일러 해와 동적 안정성)

  • Pokhrel, Bijaya P.;Shon, Sudeok;Ha, Junhong;Lee, Seungjae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.3
    • /
    • pp.83-91
    • /
    • 2018
  • In this study, we investigated the dynamic stability of the system and the semi-analytical solution of the shallow arch. The governing equation for the primary symmetric mode of the arch under external load was derived and expressed simply by using parameters. The semi-analytical solution of the equation was obtained using the Taylor series and the stability of the system for the constant load was analyzed. As a result, we can classify equilibrium points by root of equilibrium equation, and classified stable, asymptotical stable and unstable resigns of equilibrium path. We observed stable points and attractors that appeared differently depending on the shape parameter h, and we can see the points where dynamic buckling occurs. Dynamic buckling of arches with initial condition did not occur in low shape parameter, and sensitive range of critical boundary was observed in low damping constants.

Snapping Triceps Syndrome with Dislocation of the Ulnar Nerve - Usefulness of Dynamic Ultrasonography - (척골 신경 탈구와 동반된 발음성 삼두근 증후군 - 동적 초음파 검사의 유용성 -)

  • Jeong, Ung-Gyo;Park, Sang-Won;Song, Dong-Ik;Lee, Sun-Hyeok
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2008.03a
    • /
    • pp.171-171
    • /
    • 2008
  • 발음성 삼두근 증후군은 주관절을 굴곡하거나 신전할 때 삼두근 말단부 일부와 척골 신경이 내상과 전방으로 탈구되는 드문 질환이다. 이학적 검사 만으로는 다른 질환으로 오진되는 경우가 많아 정확한 진단이 필수적이며 확진을 위하여는 척골 신경 및 삼두근의 비정상적인 움직임을 관찰할 수 있는 영상 검사가 필요하다. 초음파 검사는 자기 공명 영상 촬영 등 다른 검사에 비해 간편하고 효과적으로 연부 조직의 동적 검사를 시행할 수 있는 장점이 있다. 저자들은 발음성 삼두근 증후군 환자를 동적 초음파 검사를 사용하여 진단하고 척골 신경 전방 전위술 및 삼두근 내두의 이전술을 시행하여 치유하였기에 문헌 고찰과 함께 초음파 검사의 유용성을 보고하고자 한다.

  • PDF

A Study on Tether Cables Used for Deep Submergence Vehicles (심해 잠수정용 테더 케이블에 관한 연구)

  • H. Shin;D.S. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.2
    • /
    • pp.56-67
    • /
    • 1995
  • In this paper, a ship-cable-vehicle system's static configuration is shown obtained by solving cable nonlinear statics. Eigenfrequencies of the cable were calculated by the frequency domain analysis application of the linearized cable dynamic equations. Also extreme tensions in a slack-and-snapping long vertical cable were calculated by the clip-ping-off model.

  • PDF

Snap-through Phenomena on Nonlinear Thermopeizoelastic Behavior of Piezolaminated Plates (압전적층판의 비선형 열압전탄성 거동에서의 스냅-스루 현상)

  • Oh, Il-Kwon;Lee, In
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.232-237
    • /
    • 2000
  • Thermopiezoelastic snap-through phenomena of piezolaminated plates are numerically investigated by applying a cylindrical arc-length scheme to Newton-Raphson method. Based on the layerwise displacement theory and von-Karman strain-displacement relationships, nonlinear finite element formulations are derived for thermopiezoelastic composite plates. From the static and dynamic viewpoint, nonlinear thermopiezoelastic behavior and vibration characteristics are studied for symmetric and eccentric structural models with various piezoelectric actuation modes. Present results show the possibility to enhance the performance of thermal structures using piezoelectric actuators and report new phenomena, namely thermopiezoelastic snapping, induced by the excessive piezoelectric actuation in the active suppression of thermally buckled large deflection of piezolaminated plates.

  • PDF

Ultrasonographic Examination of Compression Neuropathy in the Upper Extremity (상지의 압박성 신경병증의 초음파 검사)

  • Chung, Yang-Guk;Kim, Bae-Gyun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.1
    • /
    • pp.64-72
    • /
    • 2008
  • Compression neuropathy around elbow and wrist are one of the common disturbing problems in the upper extremity. The understanding of normal nerve architectures and pathophysiologic changes in compression neuropathy is important to interpret the ultrasonographic images correctly. Compression neuropathies have characteristic ultrasonographic imaging features of flattened nerve at compression and hypoechoic swollen nerve with loss of fascicular patterns at proximal segments. Dynamic ultrasonographic imagings on motion can show dymanic subluxation of ulnar nerve and medial head of triceps muscle over the medial epicondyle in snapping triceps syndrome. Dynamic compression of median nerve also can be visualized in pronator teres syndrome by dynamic imaging studies. A quantitative measures of cross sectional area or compression ratio can be helpful to diagnose compression neuropathies, such as carpal tunnel syndrome or cubital tunnel syndrome. With the clinical features and electeophysiologic studies, the untrasonographic imagings are useful tool for evaluation of the compression neuropathies in the upper extremities.

  • PDF

Dynamic Instability and Multi-step Taylor Series Analysis for Space Truss System under Step Excitation (스텝 하중을 받는 공간 트러스 시스템의 멀티스텝 테일러 급수 해석과 동적 불안정)

  • Lee, Seung-Jae;Shon, Su-Deok
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.289-299
    • /
    • 2012
  • The goal of this paper is to apply the multi-step Taylor method to a space truss, a non-linear discrete dynamic system, and analyze the non-linear dynamic response and unstable behavior of the structures. The accurate solution based on an analytical approach is needed to deal with the inverse problem, or the dynamic instability of a space truss, because the governing equation has geometrical non-linearity. Therefore, the governing motion equations of the space truss were formulated by considering non-linearity, where an accurate analytical solution could be obtained using the Taylor method. To verify the accuracy of the applied method, an SDOF model was adopted, and the analysis using the Taylor method was compared with the result of the 4th order Runge-Kutta method. Moreover, the dynamic instability and buckling characteristics of the adopted model under step excitation was investigated. The result of the comparison between the two methods of analysis was well matched, and the investigation shows that the dynamic response and the attractors in the phase space can also delineate dynamic snapping under step excitation, and damping affects the displacement of the truss. The analysis shows that dynamic buckling occurs at approximately 77% and 83% of the static buckling in the undamped and damped systems, respectively.

Papers : Snap - through Phenomena on Nonlinear Thermopiezoelastic Behavior of Piezolaminated Plates (논문 : 압전적층판의 비선형 열압전탄성 거동에서의 스냅 - 스루 현상)

  • O,Il-Gwon;Sin,Won-Ho;Lee,In
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.1
    • /
    • pp.36-43
    • /
    • 2002
  • Thermopiezoelastic snap-through phenomena of piezolaminated plates are investigated by applying an are-length scheme to Newton-Raphson method. Based on the layerwise displacement theory and von Karman strain-displacement relationships, nonlinear finite element formulations are derived for the thermopiezoelastic composite plates. From the static and dynamic viewpoint, nonlinear thermopierzoelastic behavior and vibration characteristicx are stuied for symmetric and eccentric structural models with various piezoelestric actuation modes. Present results show the possibility to enhance the performance, namely thermopiezoelastic snapping, induced by the excessive piezoelectric actuation in the active suppression of thermally buckled large deflection piezolaminated paltes.

Multistable Microactuators Functioning on the Basis of Electromagnetic Lorentz Force: Nonlinear Structural and Electrothermal Analyses (전자기 로렌츠력을 이용한 다중안정성 마이크로 액추에이터의 비선형 구조 및 전기-열 해석)

  • Han, Jeong-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.8
    • /
    • pp.1119-1127
    • /
    • 2010
  • In this paper, the design and nonlinear simulation of a multistable electromagnetic microactuator, which provides four stable equilibrium positions within its operating range, have been discussed. Quadstable actuator motion has been made possible by using both X- and Y-directional bistable structures with snapping curved beams. Two pairs of the curved beams are attached to an inner frame in both X- and Y-directions to realize independent bistable behavior in each direction. For the actuation of the actuator at the micrometer scale, an electromagnetic actuation method in which Lorentz force is taken into consideration was used. By using this method, micrometer-stroke quadstability in a plane parallel to a substrate was possible. The feasibility of designing an actuator that can realize quadstable motion by using the electromagnetic actuation method has been thoroughly clarified by performing nonlinear static and dynamic analyses and electrothermal coupled-field analysis of the multistable microactuator.