• Title/Summary/Keyword: Dynamic response control

Search Result 1,122, Processing Time 0.026 seconds

Extension of the Dynamic Range in the CMOS Active Pixel Sensor Using a Stacked Photodiode and Feedback Structure

  • Jo, Sung-Hyun;Lee, Hee Ho;Bae, Myunghan;Lee, Minho;Kim, Ju-Yeong;Choi, Pyung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.256-261
    • /
    • 2013
  • This paper presents an extension of the dynamic range in a complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) using a stacked photodiode and feedback structure. The proposed APS is composed of two additional MOSFETs and stacked P+/N-well/P-sub photodiodes as compared with a conventional APS. Using the proposed technique, the sensor can improve the spectral response and dynamic range. The spectral response is improved using an additional stacked P+/N-well photodiode, and the dynamic range is increased using the feedback structure. Although the size of the pixel is slightly larger than that of a conventional three-transistor APS, control of the dynamic range is much easier than that of the conventional methods using the feedback structure. The simulation and measurement results for the proposed APS demonstrate a wide dynamic range feature. The maximum dynamic range of the proposed sensor is greater than 103 dB. The designed circuit is fabricated by the $0.35-{\mu}m$ 2-poly 4-metal standard CMOS process, and its characteristics are evaluated.

Design of Friction Dampers for Seismic Response Control of a SDOF Building (단자유도 건물의 지진응답제어를 위한 마찰감쇠기 설계)

  • Min, Kyung-Won;Seong, Ji-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.1
    • /
    • pp.22-28
    • /
    • 2010
  • Approximate analysis for a building installed with a friction damper is performed to get insight of its dynamic behavior. Energy balance equation is used to have a closed analytical form solution of dynamic magnification factor(DMF). It is found out that DMF is dependent on friction force ratio and resonance frequency. Approximation of DMF and equivalent damping ratio of a friction damper is proposed with such assumption that the building with a friction damper shows harmonic steady-state response and narrow banded response behavior near resonance frequency. Linear transfer function from input external force to output building displacement is suggested from the simplified DMF equation. Root mean square of a building displacement is derived under earthquake-like random excitation. Finally, design procedure of a friction damper is proposed by finding friction force corresponding to target control ratio. Numerical analysis is carried out to verify the proposed design procedure.

Performance Evaluation of Response Reduction of Outrigger Damper System Subjected to Wind Loads (풍하중에 대한 아웃리거 댐퍼시스템의 응답 제어 성능 평가)

  • Kim, Su-Jin;Kim, Min-Ju;Kim, Jun-Il;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.2
    • /
    • pp.35-42
    • /
    • 2018
  • The outrigger damper system is a structural system with excellent lateral resistance when a wind load occurs. However, research on outrigger dampers is still in its infancy. In this study, dynamic response control performance of damper is analyzed according to change of stiffness value and damping value of damper. To do this, a real-scale 3D model of 50 stories has been developed and the artificial wind load has been entered for dynamic analysis. Generally, the larger the damping value, the smaller the stiffness value is, the more effective it is to reduce the maximum displacement and acceleration response. However, the larger the attenuation value as the cost of construction increases, it is necessary to select appropriate stiffness and damping value when applying an outrigger damper.

Dynamic Response Improvement Method for Combustion Air Flow Control in Coal Fired Power Plant (석탄 화력발전소 연소공기량 제어 동특성 개선방안)

  • Yu, Kwang-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.88-95
    • /
    • 2012
  • When controling combustion air flow in coal fired power plant the furnace safety must be considered first prior to plant efficiency. therefore it is very important to set air flow demand exactly for safe operation and maintenance. This paper analyze air flow control loop in power plant and introduce the method to improve dynamic response time. Simulation result shows this scheme is adoptable and provide better performance.

Ac Servo motor position control using Sliding mode control (슬라이딩 모우드(Sliding Mode) 제어(制御)에 의한 AC Servo motor의 위치제어(位値制御)에 관한 연구(硏究))

  • Hong, Chang-Hi;Lee, Hyoung-Ki;Park, Yang-Su
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.53-55
    • /
    • 1988
  • The application of Sliding Mode Control for inproving the dynamic response of a Multi-Phase-Bipolar (MPB) Brushless DC motor based position Brushless DC motor system is presented. Sliding Mode Control gives fast dynamic response with no overshoot and zero steady state error. It has the important feature of bins highly robust. A design procedure is outlined for the Sliding Mode Controller for a MPB Brushless DC motor. Digital computer simulation of the overall position control system is carried out using a time domain model in the d-q reference frame.

  • PDF

Design of Cold-flow Test Equipment Considering Dynamic Similarity for DACS Verification (동적상사를 고려한 DACS 검증용 공압 시험장치 설계)

  • Bae, Sangho;Chang, Hongbeen;Park, Iksoo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.374-377
    • /
    • 2017
  • A cold-flow test equipment was designed to carry out the performance verification of TDACS. For that purpose, the pressure dynamics in the solid rocket motor combustor and the cold-flow test was modeled, and the response time showing the dynamic characteristics of each model was obtained. In this paper, the system response time of the cold-flow test was designed to be equal to that of the motor, making the dynamic response in cold-flow and hot gas condition to be similar.

  • PDF

Supplementary Control of Conventional Coordinated Control for 1000 MW Ultra-supercritical Thermal Power Plant using Dynamic Matrix Control

  • Lee, Youngjun;Yoo, Euiyeon;Lee, Taehyun;Moon, Un-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.97-104
    • /
    • 2018
  • This paper proposes supplementary control of conventional coordinated control of a power plant which directly affects network frequency. The supplementary control with dynamic matrix control is applied for 1000 MW power plant with ultra-supercritical (USC) once-through boiler. The supplementary control signal is added to the boiler feedforward signal in the existing coordinated control logic. Therefore, it is a very practical structure that can maintain the existing multi-loop control system. This supplementary controller uses the step response model for the power plant system, and on-line optimization is performed at every sampling step. The simulation results demonstrate the effectiveness of the proposed supplementary control in a wide operating range of a practical 1000 MW USC power plant simulator. These results can contribute the stable operation of power system frequency.

Influence of time delay and saturation capacity to the response of controlled structures under earthquake excitations

  • Pnevmatikos, Nikos G.;Gantes, Charis J.
    • Smart Structures and Systems
    • /
    • v.8 no.5
    • /
    • pp.449-470
    • /
    • 2011
  • During the last thirty years many structural control concepts have been proposed for the reduction of the structural response caused by earthquake excitations. Their research and implementation in practice have shown that seismic control of structures has a lot of potential but also many limitations. In this paper the importance of two practical issues, time delay and saturation effect, on the performance of controlled structures, is discussed. Their influence, both separately and in interaction, on the response of structures controlled by a modified pole placement algorithm is investigated. Characteristic buildings controlled by this algorithm and subjected to dynamic loads, such as harmonic signals and actual seismic events, are analyzed for a range of levels of time delay and saturation capacity of the control devices. The response reduction surfaces for the combined influence of time delay and force saturation of the controlled buildings are obtained. Conclusions regarding the choice of the control system and the desired properties of the control devices are drawn.

Model Establishment of a Deployable Missile Control Fin Using Substructure Synthesis Method (부구조물 합성법을 이용한 접는 미사일 조종날개 모델 수립)

  • Kim, Dae-Kwan;Bae, Jae-Sung;Lee, In;Han, Jae-Hung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.7 s.100
    • /
    • pp.813-820
    • /
    • 2005
  • A deployable missile control fin has some structural nonlinearities because of the worn or loose hinges and the manufacturing tolerance. The structural nonlinearity cannot be eliminated completely, and exerts significant effects on the static and dynamic characteristics of the control fin. Thus, It is important to establish the accurate deployable missile control fin model. In the present study, the nonlinear dynamic model of 4he deployable missile control fin is developed using a substructure synthesis method. The deployable missile control fin can be subdivided Into two substructures represented by linear dynamic models and a nonlinear hinge with structural nonlinearities. The nonlinear hinge model is established by using a system identification method, and the substructure modes are improved using the Frequency Response Method. A substructure synthesis method Is expanded to couple the substructure models and the nonlinear hinge model, and the nonlinear dynamic model of the fin is developed. Finally, the established nonlinear dynamic model of the deployable missile control fin is verified by dynamic tests. The established model is In good agreement with test results, showing that the present approach is useful in aeroelastic stability analyses such as time-domain nonlinear flutter analysis.

Impact response of a novel flat steel-concrete-corrugated steel panel

  • Lu, Jingyi;Wang, Yonghui;Zhai, Ximei;Zhou, Hongyuan
    • Steel and Composite Structures
    • /
    • v.42 no.2
    • /
    • pp.277-288
    • /
    • 2022
  • A novel flat steel plate-concrete-corrugated steel plate (FS-C-CS) sandwich panel was proposed for resisting impact load. The failure mode, impact force and displacement response of the FS-C-CS panel under impact loading were studied via drop-weight impact tests. The combined global flexure and local indentation deformation mode of the FS-C-CS panel was observed, and three stages of impact process were identified. Moreover, the effects of corrugated plate height and steel plate thickness on the impact responses of the FS-C-CS panels were quantitatively analysed, and the impact resistant performance of the FS-C-CS panel was found to be generally improved on increasing corrugated plate height and thickness in terms of smaller deformation as well as larger impact force and post-peak mean force. The Finite Element (FE) model of the FS-C-CS panel under impact loading was established to predict its dynamic response and further reveal its failure mode and impact energy dissipation mechanism. The numerical results indicated that the concrete core and corrugated steel plate dissipated the majority of impact energy. In addition, employing end plates and high strength bolts as shear connectors could prevent the slip between steel plates and concrete core and assure the full composite action of the FS-C-CS panel.