• 제목/요약/키워드: Dynamic pile capacity

검색결과 103건 처리시간 0.023초

지반굴착에 소요되는 전기식모터의 전류저항값 변화에 관한 연구 (A Study of Change in Current Resistance Value of Electric Motor Requied for Ground Dilling)

  • 서동남;정상훈;이상현;신진섭;최상호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.385-386
    • /
    • 2023
  • In this application study, field pilot tests were performed to evaluate the validity of a proposed formula between the exerted electrical energy and SPT N-value based on the result of the basic study. Measurement sensors and recording system were developed to obtain exerted motor current and drilling depth in a field. By using the correlation formula proposed in the basic study, the measured motor current and boring speed were applied to predict SPT N-value and the predicted N-values were compared to SPT N-value of site exploration. From the comparisons it is verified that the exerted electrical energy to bore ground might be used to predict SPT N-value and pile tip location.

  • PDF

연약점토지반에 적용한 우산형 마이크로파일의 지진시 수평거동 특성 (Horizontal Behavior Characteristics of Umbrella-Type Micropile Applied in Soft Clay Ground subjected to Seismic Motion)

  • 김수봉;손수원;김진만
    • 한국산학기술학회논문지
    • /
    • 제21권6호
    • /
    • pp.687-695
    • /
    • 2020
  • 본 논문은 한국산학기술학회 논문지 최종용 투고요령입니다. 마이크로파일은 기존 구조물의 안정성을 향상시키기 위해 사용되고 있을 뿐만 아니라 사면활동 억제, 옹벽의 전단키 등 다양한 지반 공학적 문제를 해결하기 위해 사용되고 있다. 기존 마이크로파일 공법은 연직력에 대해서는 PHC파일이나 강관파일에 비교하여 어느 정도 지지력을 확보하지만 상대적으로 작은 파일 직경으로 인해 수평력에 대해서는 연직력에 비해 현저히 낮은 지지력 양상을 보이고 있다. 이에 내진성능 향상에 우수한 우산형 마이크로파일 공법을 개발하여 기존시설물 내 국한된 협소한 장소에서 시설물의 및 지반 교란영역을 최소화하면서 경제적으로 내진성능을 확보할 수 있도록 연구해야 한다. 본 연구에서는 기존 마이크 로파일의 수평지지력이 약한 단점을 보완하기 위해 사항과 연직말뚝을 일체형으로 제작한 우산형 마이크로파일에 대해 수치해석을 수행하여 연약점토 지반에서의 지진시 수평거동을 분석하였다. 수치해석 결과, 연약점토지반에서 우산형 마이크로파일은 수평변위 억제효과가 있었으며, 경사말뚝의 근입심도가 15m이상일 경우에 수평변위 저감 효과가 뚜렷했다. 마이크로파일의 근입심도와 수평변위 억제효과가 비례하였다. 이에 우산형 마이크로파일이 연약점토 지반에서 지진시 수평변위 억제효과가 우수한 것으로 판단된다.

정화 보조지표와 시료 채취 방법 제안을 통한 토양정화검증 제도 개선 연구 (Improvement of Verification Method for Remedial Works through the Suggestion of Indicative Parameters and Sampling Method)

  • 권지철;이군택;김태승;윤정기;김지인;김용훈;김준영;최정민
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제21권6호
    • /
    • pp.179-191
    • /
    • 2016
  • In addition to the measurement of the concentration of soil contaminants, the new idea of indicative parameters was proposed to validate the remedial works through the monitoring for the changes of soil characteristics after applying the clean up technologies. The parameters like CFU (colony forming unit), pH and soil texture were recommended as indicative parameters for land farming. In case of soil washing, water content and the particle size distribution of the sludge were recommended as indicative parameters. The sludge is produced through the particle separation process in soil washing and it is usually treated as a waste. The parameters like water content, organic matter content, CEC (cation exchange capacity) and CFU were recommended as indicative parameters for the low temperature thermal desorption method. Besides the indicative parameter, sampling methods in stock pile and the optimal minimum amount of composite soil sample were proposed. The rates of sampling error in regular grid, zigzag, four bearing, random grid methods were 17.3%, 17.6%, 17.2% and 16.5% respectively. The random grid method showed the minimum sampling error among the 4 kinds of sampling methods although the differences in sampling errors were very little. Therefore the random grid method was recommended as an appropriate sampling method in stock pile. It was not possible to propose a value of optimal minimum amount of composite soil sample based on the real analytical data due to the dynamic variation of $CV_{fund{\cdot}error}$. Instead of this, 355 g of soil was recommended for the optimal minimum amount of composite soil sample under the assumption of ISO 10381-8.