• Title/Summary/Keyword: Dynamic movement

Search Result 972, Processing Time 0.023 seconds

Effects of Czech get up Exercise on Functional Movement and Dynamic Balance in Female Office Worker

  • Kim, Chan-Yang;Lee, Jin-Wook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.5
    • /
    • pp.215-224
    • /
    • 2022
  • The purpose of this study is to analyze how it affects functional movement and dynamic balance applying Czech get up exercise based on the principle of motor development of child for office worker women in 30s and 40s. Through random allocation, an Czech get up exercise group(n=15) and a control group(n=14) were formed to apply exercise for 12 weeks, 3 times a week, and 60 minutes a day, and the control group maintained daily life at the same period. As a result of the study, showed that Deep squat(p<.05), Hurdle step(p<.01), In-line lunge(p<.05), Trunk stability push-up(p<.001), Rotary stability (p<.01), Total score(p<.001), were significantly in the Czech get up Group, and Dynamic Balance of Lower Extremity(p<.001), Right Dynamic Balance of Lower Extremity(p<.001) were also significantly in the Czech get up Group. In conclusion, it is thought that Czech get up exercise based on the principle of motor development of child will have a positive effect on the functional movement and dynamic balance in office women, thereby increasing work efficiency as well as healthy life.

Analysis of the Reduction of the Dynamic Response for the CNC 5 Axles Machining Center (CNC 5축 공작기계의 동응답 저감 해석)

  • KIM, Gi Man;CHOI, Seong Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.5
    • /
    • pp.83-89
    • /
    • 2010
  • In this paper, the dynamic response of a CNC 5 Axles machining center was analyzed and then controlled passively by using the dynamic absorber. For the simplification of the theoretical approach, the CNC 5 Axles machining center was modeled as a flexible beam(Bed) having a point mass(Column), two discrete systems(a Table-set and a dynamic absorber). Specifically by using the dynamic absorber, the dynamic response of a Table-set which be caused by the vibration of a flexible beam, was reduced down to the infinitesimal level. The optimal design factors of the dynamic absorber were obtained from the minimization of the cost function. It was found that the natural frequencies of a UT-380 machining center be varied due to the movement of the Table-set. In view of the dynamic response of a Table-set, the larger spring stiffness and mass of the dynamic absorber were found to give the greater reduction.

Dynamic Analysis of Lateral Pile under Seismic Loading (지진하중을 받는 파일기초의 횡방향 동적 거동해석)

  • 이인모;이현종
    • Geotechnical Engineering
    • /
    • v.4 no.1
    • /
    • pp.29-36
    • /
    • 1988
  • Dynamic analysis of lateral pile under seismic loading is performed in this paper. As an analytical model, the Bean-on-twinkler Foundation Model is used for this study because of its simplicity and acceptible accuracy . The method suggested by Kagawa and Kraft, which can account for non-linear effects, is used for the dynamic P-y relationship This relationship is found to be the most important factor in analysis . Group pile effects are also considered approximately The results of dynamic analysis show that a pile without supporting mass follows the soil movement ; in the case of a pile with supporting mass, the relative displacement between the soil and the pile occurs . When designing piles, it must be considered that piles have to resist the curvatures originated by the soil movement.

  • PDF

A Study on the Behavior Characteristics of a Tensioning Device of a Catenary System According to the Longitudinal Dynamic Displacement of Railroad Bridge (철도교량의 종방향 동적 변위에 따른 전차선로 장력조정장치 거동특성에 관한 연구)

  • Na, Youn-Il;Lee, Jae-Bong;Kim, Jae-Moon;Kim, Yang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.10
    • /
    • pp.1517-1522
    • /
    • 2015
  • Since electric railroad vehicle pass through repeatedly on the railroad bridge, the dynamic load that causes the change of tension of contact wire affect it constantly. In this paper, we measured the dynamic displacement of the railroad bridges to analyze the effect of tension in the catenary. A result of dynamic measurement of the longitudinal displacement, it's maximum value was 39.9mm which was lower than the primary management criteria 378mm. Also on the based of a maximum temperature, it shows a feature that the longitudinal displacement value increased as temperature rise from April to October. In terms of behavior characteristics of a tensioning device, it was confirmed to be the value of 50mm stroke movement when the temperature changes ±5℃.

Effects of the earth fissure on the seismic response characteristics of a nearby metro station

  • Jiang Chang;Yahong Deng;Huandong Mu
    • Earthquakes and Structures
    • /
    • v.24 no.1
    • /
    • pp.53-64
    • /
    • 2023
  • Earth fissures with several kilometers will inevitably approach or cross the metro line, significantly threatening the safety of the underground structure in the earth fissure site. However, the influence of the earth fissure site's amplification effect on the metro station's dynamic response is still unclear. A representative earth fissure in Xi'an was taken as an example to establish a numerical model of a metro station in the earth fissure site. The dynamic response characteristics of the metro stations at different distances from the earth fissure under various seismic waves were calculated. The results show that the existence of the earth fissure significantly amplifies the dynamic response of the nearby underground structures. The responses of the axial force, shear force, bending moment, normal stress, horizontal displacement, inter-story drift, and relative slip of the metro station were all amplified within a specific influence range. The amplification effect increases with the seismic wave intensity. The amplification effect caused by the earth fissure has relatively weak impacts on the axial shear, shear force, bending movement, normal stress, and horizontal movement; slightly larger impacts on the inter-story drift and acceleration; and a significant impact on the relative slip. The influence ranges of the axial force and normal stress are approximately 20 m. The influence ranges of the acceleration and inter-story drift can reach 30 m. Therefore, the seismic fortification level of the underground structure in the earth fissure site needs to be improved.

Implementation of Nuclear Medicine Dynamic Cardiac Phantom for Clinical Application (임상적용을 위한 핵의학 동적 심장팬텀의 구현)

  • Lee, Joo-Young;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.53-59
    • /
    • 2019
  • In the field of nuclear medicine, the various static phantoms of international standards are used to assess the performance of the nuclear medicine equipment. However, we only reproduced a fixed situation in spite of the movement of the cardiac, and the demands for dynamic situations have been continuously raised. More research is necessary to address these challenges. This study used flexible materials to design the dynamic cardiac phantom, taking into account the various clinical situations. It also intended to reproduce the images through dynamic cardiac flow to confirm the usefulness of the proposed technique. The frame of dynamic cardiac phantom was produced based on the international standard phantom. A nuclear medicine dynamic cardiac phantom was produced rubber material and silicone implemented by 3D printing technique to reproduce endocardium and epicardium movement. Therefore we compared and evaluated the image of a cardiac phantom made of rubber material and a cardiac phantom made of silicone material by 3D printing technique. According to the results of this study, the analysis of the Summed Rest Score(SRS) showed abnormalities in the image of a cardiac phantom made of rubber material at 10, 20, and 30 stroke rates, but the image of a cardiac phantom made of silicone material by 3D printing technique showed normal levels. And the analysis of the Total Perfusion Deficit(TPD) showed that TPD in the image of a cardiac phantom made of rubber material was higher than that of the image of a cardiac phantom made of silicone material by 3D printing technique at 10, 20, and 30 stroke rates. The potential for clinical application of the proposed method was confirmed in the dynamic cardiac phantom implemented with 3D printing technique. It is believed that the objective information secures the reliability of inspection equipment and it contributes to improve the diagnostic value of nuclear medicine.

The Effects of a Functional Movement Screen on Pain and Performance Ability in Professional Fencing Players (펜싱선수에서 통증과 수행 능력이 기능적 동작 검사에 미치는 영향)

  • Kim, Seong-Yeol;Lee, Je-Hoon;An, Seung-Heon
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.21-28
    • /
    • 2011
  • Purpose: The aim of this study was to investigate correlations between the Functional Movement Screen (FMS), pain, and performance ability in professional fencing players. Methods: Fifty-six athletes participated in this study. The pain group included those who had a score on a pain-related Visual Analogue Scale (VAS) of ${\geq}$20 and an Oswestry Disability Index (ODI) score ${\geq}$10). In the non-pain group, these scores were: VAS(<20), ODI(<10). The VAS and ODI were used to measure pain throughout the study. Performance ability included motor function of the lower extremities (as assessed by a Modified Functional Index Questionnaire, MFIQ), dynamic balance (Balance system, BS and Posture med, PM), flexor and extensor muscle strength of the lumbar region was recorded as maximal isometric strength. Results: Among athletes who had pain, 5 of 15(33.33%) showed impaired functional movement. Conversely, only 2 of 41(4.88%) of those who had no pain showed such impairment (FMS ${\leq}$14score). The athletes who had pain and who had an FMS score above 14 (10/56; 17.86%) showed a significantly higher score for extensor muscle strength of the lumbar compared with those with pain and an FMS score below 14 (5/56; 8.93%) were significant correlations between the FMS and pain (r=-0.40 to -0.42, p<0.01), the MFIQ (r=-0.33, p<0.05), dynamic balance (r=-0.27 to -0.40, p<0.05-0.01), muscle strength of the lumbar (r=0.27 to 0.29, p<0.05). Stepwise multiple regression analysis showed that the dynamic balance score (${\beta}{\beta}$=-0.41) had slightly more power in predicting FMS score than pain, motor function of lower extremity, or muscle strength. Conclusion: The FMS was significantly associated with values of pain, motor function of the lower extremities, dynamic balance, and muscle strength of the lumbar. However the FMS appears to lack relevance and reasonable evidence to suggest that it is an acceptable measurement tool for functional movement analysis.

A Study of Performance and Analysis of Dynamic Signature Verification System (동적 서명검증시스템의 성능 평가에 관한 연구)

  • 김진환;조혁규;차의영
    • Proceedings of the IEEK Conference
    • /
    • 2003.07d
    • /
    • pp.1537-1540
    • /
    • 2003
  • Dynamic signature verification technology is to verify the signer by calculating his writing manner, speed, angle, and the number of strokes, order, down/up/movement of pen when the signer input his signature with an electronic pen for his authentication In this paper, we will study an abjective basis for performance and analysis of the dynamic signature verification system.

  • PDF