• 제목/요약/키워드: Dynamic mechanical analyzer

검색결과 89건 처리시간 0.025초

유리전이온도(Tg) 측정에 의한 무기/유기복합체의 결합특성에 관한 연구 (A study on the bonding Characteristics of Inorganic/Organic Composite by Measurement of the Glass Transition Temperature(Tg))

  • 이동아;김구대;김현민
    • 분석과학
    • /
    • 제5권3호
    • /
    • pp.309-317
    • /
    • 1992
  • 졸-겔법에 의해 무기-유기 복합체를 합성하였으며, 복합체의 결합특성을 알아보기 위하여 DMTA(Dynamic Mechanical Thermal Analyzer)를 이용하여 유리전이 온돈(Tg)를 측정하였다. HCl 과 물의 양이 증가될수록 Tg는 고운으로 진행됨으로부터 복합화가 더 잘 일어남을 알 수 있었다. 그러나 반응시간에 따른 Tg의 변화는 관찰되지 않았다.

  • PDF

Study on the Underwater Acoustic Properties of Polyurethane Elastomer

  • Shin, Hyun Dai;Ahn, Byung Hyun
    • Elastomers and Composites
    • /
    • 제52권4호
    • /
    • pp.326-331
    • /
    • 2017
  • Two kinds of polyurethane elastomers were prepared and their acoustical properties underwater investigated. Their dynamic mechanical properties were measured using a dynamic mechanical analyzer. The sound speed and echo reduction in the 1-50 kHz frequency range were calculated from the data obtained using the analyzer. The sound speed, transmission and attenuation cofficient in 300-800 kHz were measured in a water-filled tank. Impedance tube experiments were performed to determine the reflective coefficient and echo reduction in the 3-8 kHz range. The polyurethane elastomer containing a hollow glass sphere showed a lower reflective coefficient and a higher echo reduction than the polyurethane elastomer without a filler.

복합적인 환경인자가 탄소섬유강화 복합재의 기계적 및 열분석 특성에 미치는 영향 (Effects of Combined Environmental Factors on Mechanical and Thermal Analysis Properties of Graphite/Epoxy Composites)

  • 이상진;이종근;윤성호
    • 대한기계학회논문집A
    • /
    • 제26권7호
    • /
    • pp.1416-1425
    • /
    • 2002
  • In this study, the effects of combined environmental factors on mechanical and thermal analysis properties of graphite/epoxy composites were evaluated by the use of an accelerated aging test. Environmental factors such as temperature, moisture. and ultraviolet were considered. A xenon-arc lamp was utilized for ultraviolet light. and exposure times of up to 3000 hours were applied. Several types of specimens - tensile. bending, and shear specimens those are transverse to the fiber direction, and bending specimens those are parallel to the tiber direction - were used to investigate the effects of environmental factors on mechanical properties of the composites. Also, glass transition temperature, storage shear modulus, loss shear modulus, and tan ${\delta}$ were measured as a function of exposure times through a dynamic mechanical analyzer. In addition. a suitable testing method for determining the effect of environmental factors on mechanical properties is suggested by comparing the results from using two different types of strain measuring sensors. Finally, composite surfaces exposed to environmental factors were examined using a scanning electron microscope.

Acoustic Emission(AE)을 이용한 복합재료 구조물의 비파괴 특성 연구 (A study on the non-destructive characteristics of the composite structures using the Acoustic Emission)

  • 이창훈;최진호;권진회;변준형;유연호
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 춘계학술발표대회 논문집
    • /
    • pp.139-142
    • /
    • 2004
  • As fiber reinforced composite materials are widely used in aircraft, space structures and robot arms, the study on the non-destructive testing methods of the composite materials has become an important research area for improving their reliability and safety. In this paper, the AE signal analyzer with the resonance circuit to extract the specified frequency of the acoustic emission signal were designed and fabricated. The noise levels of the fabricated AE signal analyzer by the disturbance such as impact or mechanical vibration had a very small value comparable to those of the conventional AE signal analyzer. Also, the crack detection capabilities of the fabricated AE signal analyzer under the static and dynamic tensile test were evaluated and compared with the conventional AE signal analyzer.

  • PDF

Measurement of Dynamic Compressive Properties of Apples using the Oscillatory Test

  • Lee, Jong-Whan;Tan, Jinglu;Waluyo, Sri
    • Journal of Biosystems Engineering
    • /
    • 제37권1호
    • /
    • pp.28-35
    • /
    • 2012
  • Purpose: This study performed the oscillatory test using the texture analyzer to characterize the viscoelastic behavior of apples such as the storage modulus (E'), the loss modulus (E"), the complex modulus (${\mid}E^*{\mid}$) and the energy dissipated per cycle ($W_{diss}$). Methods: The sinusoidal deformation with the frequency of 1-10 Hz and the maximum displacement of 0.1 mm were applied to the flesh tissues of Fuji, Golden Delicious and Red Delicious apples. The Lissajous figure was used to measure the phase angle(${\delta}$) between stress and strain curve. Results: Trigger force was critical to the measurement of the phase angle. E', E", ${\mid}E^*{\mid}$ and Wdiss were measured using the Lissajous figure and the phase angle. The complex modulus of Golden Delicious apple was significantly lower than those of Fuji apple and Red Delicious apple. Conclusions: Apple flesh was exhibiting more elasticity at low frequency, and more viscosity at high frequency. Dynamic compressive properties of Fuji apple were similar to those of Red Delicious apple but significantly different from those of Golden Delicious apple.

이방성 전도 접착제 물성과 유기 기판 플립 칩의 신뢰성에 미치는 비전도성 충진재의 영향 (Effect of Non-Conducting Filler Additions on Anisotropic Conductive Adhesives(ACAs) Properties and the Reliability of ACAs Flip Chip on Organic Substrates)

  • 임명진;백경욱
    • 한국재료학회지
    • /
    • 제10권3호
    • /
    • pp.184-190
    • /
    • 2000
  • 비전도성 충진재를 포함한 개선된 이방성 전도 접착제의 열적/기계적 특성과 이를 이용한 유기 기판용 플립 칩의 신뢰성에 미치는 충진재 양의 영향을 고찰하였다. 비전도성 충진재 양이 다른 개선된 이방성 접착제의 특성을 살펴보기 위해 differential scanning calorimeter (DSC), thermo-gravimetric analyzer (TGA), dynamic mechanical analyzer (DMA), thermo-mechanical analyzer (TMA)을 사용하였다. 비전도성 충진재의 양이 증가함에 따라 열팽창계수는 감소하였고, 상온에서의 storage modulus는 증가하였다. 추가로, 충진재의 양이 증가하면 DSC에 의한 유리전이온도와 TMA에 의한 유리전이온도도 증가하였다. 그러나 TGA 거동은 거의 변화가 없었다. 이방성 전도 접착제를 사용한 유기 기판 플립 칩의 신뢰성 테스트를 위해 열주기 시험, 고온고습 시험, 고온건조 시험을 수행하였는데, 주로 열주기 시험에서 이방서 전도 접착제의 열팽창계수의 영향이 컸다. 비전도성 충진재를 포함해서 낮은 열팽창계수와 높은 storage modulus를 갖는 이방성 전도 접착제에 의해 부착된 플립 칩의 신뢰성이 비전도성 충진재를 포함하지 않은 이방성 전도 접착제에 의한 플립 칩의 신뢰성보다 더 좋게 나타났다.

  • PDF

Experimental Validation of Numerical Model for Turbulent Flow in a Tangentially Fired Boiler with Platen Reheaters

  • Zheng, Chang-Hao;Xu, Xu-Chang;Park, Jong-Wook
    • Journal of Mechanical Science and Technology
    • /
    • 제17권1호
    • /
    • pp.129-138
    • /
    • 2003
  • A 1 : 20 laboratory scale test rig of a 200 MW tangentially fired boiler is built up with completely simulated structures such as platen heaters and burners. Iso-thermal turbulent flow in the boiler is mapped by 3-D PDA (Particle Dynamic Analyzer). The 3-D numerical models for the same case are proposed based on the solution of к-$\varepsilon$ model closed RANS (Reynolds time-Averaged Navier-Stokes) equations, which are written in the framework of general coordinates and discretized in the corresponding body-fitted meshes. Not only are the grid lines arranged to fit the inner/outer boundaries. but also to align with the streamlines to the best possibility in order to reduce the NDE (numerical diffusion errors). Extensive comparisons of profiles of mean velocities are carried out between experiment and calculation. Predicted velocities in burner region were quantitatively similar with measured ones, while those in other area have same tendency with experimental counterpart.

Reliability Enhancement of Anisotropic Conductive Adhesives Flip Chip on Organic Substrates by Non-Conducting Filler Additions

  • Paik, Kyung-Wook;Yim, Myung-Jin
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2000년도 Proceedings of 5th International Joint Symposium on Microeletronics and Packaging
    • /
    • pp.9-15
    • /
    • 2000
  • Flip chip assembly on organic substrates using ACAs have received much attentions due to many advantages such as easier processing, good electrical performance, lower cost, and low temperature processing compatible with organic substrates. ACAs are generally composed of epoxy polymer resin and small amount of conductive fillers (less than 10 wt. %). As a result, ACAs have almost the same CTE values as an epoxy material itself which are higher than conventional underfill materials which contains lots of fillers. Therefore, it is necessary to lower the CTE value of ACAs to obtain more reliable flip chip assembly on organic substrates using ACAs. To modify the ACA composite materials with some amount of conductive fillers, non-conductive fillers were incorporated into ACAs. In this paper, we investigated the effect of fillers on the thermo-mechanical properties of modified ACA composite materials and the reliability of flip chip assembly on organic substrates using modified ACA composite materials. For the characterization of modified ACAs composites with different content of non-conducting fillers, dynamic scanning calorimeter (DSC), and thermo-gravimetric analyzer (TGA), dynamic mechanical analyzer (DMA), and thermo-mechanical analyzer (TMA) were utilized. As the non-conducting filler content increased, CTE values decreased and storage modulus at room temperature increased. In addition, the increase in tile content of filler brought about the increase of Tg$^{DSC}$ and Tg$^{TMA}$. However, the TGA behaviors stayed almost the same. Contact resistance changes were measured during reliability tests such as thermal cycling, high humidity and temperature, and high temperature at dry condition. It was observed that reliability results were significant affected by CTEs of ACA materials especially at the thermal cycling test. Results showed that flip chip assembly using modified ACA composites with lower CTEs and higher modulus by loading non-conducting fillers exhibited better contact resistance behavior than conventional ACAs without non-conducting fillers.ers.

  • PDF

일체형 분광편광간섭모듈 기반 분광타원편광계의 정확도 향상 (Accuracy Enhancement of Dynamic Spectroscopic Polarimetry)

  • 황국현;심준보;최인호;최석현;헤리저데헌거흐 사이드;김대석
    • 반도체디스플레이기술학회지
    • /
    • 제22권3호
    • /
    • pp.90-95
    • /
    • 2023
  • We describe an optimal alignment method for improving accuracy of dynamic spectroscopic polarimeter based on monolithic polarizing interferometer. The dynamic spectroscopic polarimeter enables real-time measurements of spectral ellipsometric parameters by using a spectral carrier frequency concept. However, the non-polarizing beam splitter used in the monolithic polarizing interferometer cannot maintain the polarization state perfectly due to phase retardation caused by optical anisotropic characteristics of the non-polarizing beam splitter, resulting in degraded measurement accuracy. The effect of the beam splitter can be minimized through optimal alignment of the polarizers used in the polarizing interferometer and the analyzer. We demonstrate how much the proposed alignment method can enhance the measurement accuracy by comparing with previous alignment approach.

  • PDF

이중분무 교차지역에서의 액적유동특성의 통계학적 분석에 관한 연구 (A Study on the Statistical Analysis of the Flow Characteristics of Droplet in the Cross Region of Twin Spray)

  • 조대진;윤석주;최태민
    • 대한기계학회논문집
    • /
    • 제18권3호
    • /
    • pp.635-644
    • /
    • 1994
  • This study investigated mainly on the flow characteristics of a droplet in the cross region of twin spray. The velocities of the droplet were measured along the axial and radial direction, and the flow characteristics of the droplet were statistically analyzed. For the statistical analysis, the probability density of the turbulent components has been studied, and then the Reynolds shear stress, the skewness and the flatness factors were calculated, and compared with the Gaussian value. Two pressure swirl stomizers were used for the twin spray system and kerosene was employed as the working liquid. 2-D PDA(particle dynamic analyzer) was used for the purpose of the measurement of droplet size and velocities. As a result, it was found that (1) the droplets collision was taken place strongly in the cross region. So, a large momentum loss of droplets due to the loss of natural movement direction was occurred, and momentum loss of radial direction was greater than that of axial direction. (2) The axial direction skewness factor approached to zero like the Gaussian distribution in the cross region of twin spray. (3) In the cross region of twin spray, the fluctuation instability of droplet was increased because of the development of the turbulence characteristics due to the droplet collision.