• Title/Summary/Keyword: Dynamic imaging

Search Result 495, Processing Time 0.025 seconds

A Study on Dynamic Safety Navigation Envelopes Considering a Ship's Position Uncertainty

  • Pyo-Woong Son;Youngki Kim;Tae Hyun Fang;Kiyeol Seo
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.3
    • /
    • pp.289-294
    • /
    • 2023
  • As technologies such as cameras, Laser Imaging, Detection, and Ranging (LiDAR), and Global Navigation Satellite Systems (GNSS) become more sophisticated and common, their use in autonomous driving technologies is being explored in various fields. In the maritime area, technologies related to collision avoidance between ships are being developed to evaluate and avoid the risk of collision between ships by setting various scenarios. However, the position of each vessel used in the process of developing collision avoidance technology between vessels uses data obtained through GNSS, and may include a position error of 10 m or more depending on the situation. In this paper, a study on the dynamic safety navigation range including the positional inaccuracy of the ship is conducted. By combining the concept of the protection level obtained using GNSS raw data with a conventional safe navigation range, a safer navigation range can be calculated for dynamic navigation. The calculated range is verified using data obtained while sailing in an actual sea environment.

Investigation of Radiation Effects on the Signal and Noise Characteristics in Digital Radiography (디지털 래디오그라피의 신호 및 잡음 특성에 대한 방사선 영향에 관한 연구)

  • Kim, Ho-Kyung;Cho, Min-Kook;Graeve, Thorsten
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.756-767
    • /
    • 2007
  • For the combination of phosphor screens having various thicknesses and a photodiode array manufactured by complementary metal-oxide-semiconductor (CMOS) process, we report the observation of image-quality degradation under the irradiation of 45-kVp spectrum x rays. The image quality was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). For the accumulation of the absorbed dose, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. While the MTF was only slightly affected by the total ionizing dose, the noise power in the case of $Min-R^{TM}$ screen, which is the thinnest one among the considered screens in this study, became larger as the total dose was increased. This is caused by incomplete correction of the dark current fixed-pattern noise. In addition, the increase tendency in NPS was independent of the spatial frequency. For the cascaded model analysis, the additional noise source is from direct absorption of x-ray photons. The change in NPS with respect to the total dose degrades the DQE. However, with carefully updated and applied correction, we can overcome the detrimental effects of increased dark current on NPS and DQE. This study gives an initial motivation that the periodic monitoring of the image-quality degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors.

3D Analysis of Scene and Light Environment Reconstruction for Image Synthesis (영상합성을 위한 3D 공간 해석 및 조명환경의 재구성)

  • Hwang, Yong-Ho;Hong, Hyun-Ki
    • Journal of Korea Game Society
    • /
    • v.6 no.2
    • /
    • pp.45-50
    • /
    • 2006
  • In order to generate a photo-realistic synthesized image, we should reconstruct light environment by 3D analysis of scene. This paper presents a novel method for identifying the positions and characteristics of the lights-the global and local lights-in the real image, which are used to illuminate the synthetic objects. First, we generate High Dynamic Range(HDR) radiance map from omni-directional images taken by a digital camera with a fisheye lens. Then, the positions of the camera and light sources in the scene are identified automatically from the correspondences between images without a priori camera calibration. Types of the light sources are classified according to whether they illuminate the whole scene, and then we reconstruct 3D illumination environment. Experimental results showed that the proposed method with distributed ray tracing makes it possible to achieve photo-realistic image synthesis. It is expected that animators and lighting experts for the film and animation industry would benefit highly from it.

  • PDF

Analysis of Original and Processing Image by Control of Exposure Dose, kVp in Digital Radiography (디지털 방사선에서 조사선량과 관전압조절에 의한 원본영상과 처리영상 분석)

  • Kim, Bo-Ra;Ryu, Sin-Young;Seok, Jin-Young;Choi, Jun-Gu
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.49-53
    • /
    • 2011
  • Dynamic range on the digital detector can be a representation to the ratio of maximum and minimum of pixel value. Wide dynamic range and post processing ability of the digital detector made difficult to recognize visually to high or low dose images. We were evaluated a change of mean pixel value on the original and processed image, when we controlled the kVp, mA, exposure time on the digital detector. On the kVp of a constant condition, we were acquired an original and processed image by changes of mA, exposure time. According to the thickness of the subject under the same conditions, to determine a relation of pixel value and X-ray intensity, we used an aluminum step wedge. When mA and exposure times were changed under the kVp of a constant condition, the X-ray intensity was decreased by the reduction of the mean pixel value. In addition when kVp was increased in a constant condition of mAs, the mean pixel value was increased according to the increment of the X-ray intensity. Therefore, low kVp, high mA and short exposure time were a way to reduce a patient dose.

  • PDF

The association between pain, balance, fall, and disability in patients with lumbar spinal stenosis with vascular claudication

  • Gunes, Musa;Ozmen, Tarik;Guler, Tugba Morali
    • The Korean Journal of Pain
    • /
    • v.34 no.4
    • /
    • pp.471-478
    • /
    • 2021
  • Background: The effect of lumbar spinal stenosis (LSS) and peripheral vascular disease (PVD), which occurs with similar degenerative conditions, when seen together, has not been studied. The aim of this study is to examine and compare the relationship between pain, balance, disability, fear of falling, and kinesiophobia in LSS patients with intermittent vascular claudication (IVC). Methods: Seventy-two patients diagnosed with LSS using magnetic resonance imaging participated in this study. Thirty-five patients with IVC symptoms and showing vascular lesions by lower extremity venous and arterial Doppler ultrasonography imaging were included in the IVC-LSS group. The pain, static balance, dynamic balance, disability, fear of falling, and kinesiophobia were evaluated using the numeric rating scale, single leg stance test, Time Up and Go (TUG), the Oswestry Disability Index (ODI), Fall Efficacy Scale-International (FES-I), and Tampa Scale for Kinesiophobia (TSK), respectively. Results: Age and female sex were found to be higher in the IVC-LSS group (P = 0.024; P = 0.012). The IVC-LSS group had a shorter single leg stance time and TUG test duration, pain intensity, ODI, FES-I, and TSK scores were higher than patients with LSS (P = 0.001). Pain, fear of falling, and kinesiophobia were moderately correlated with disability in the IVC-LSS group. No relationship was found between pain and dynamic balance. Also, the pain was not related to kinesiophobia. Conclusions: The findings indicated that IVC causes loss of balance and an increase in pain, disability, fear of falling, and kinesophobia in patients with LSS.

On-line Magnetic Resonance Quality Evaluation Sensor

  • Kim, Seong-Min;McCarthy, Michael J.;Chen, Pictiaw;Zion, Boaz
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.314-324
    • /
    • 1996
  • A high speed NMR quality evaluation sensor was designed , constructed and tested . The device consists of an NMR spectrometer coupled to a conveyor system. The conveyor was run at speeds ranging from 0 to 250 mm/s. Spectral of avocado fruits and one-dimensional magnetic resonance images of pickled olives were acquired while the samples were moving on a conveyor belt mounted through a 20Tesla NMR magnet with a 20 mm diameter surface coil and a 150 mm diameter imaging coil respectively. Fro a magnetic resonance spectrum analysis, motion through variations in the magnetic field tends to narrow spectral line width just like using sample rotation in high resolution NMR to narrow spectral line width. Spectrum analysis was used to detect the dry weight of avocado fruits using the ratio oil and water resonance peaks. Good correlations maximum r=0.970@ 50 mm/s and minimum r=0.894@250mm/s ) between oil and water resonance peak ratio and dry weight of avocados were observed at speeds ra ging from0 to 250mm/s. For the application of magnetic resonance imaging (MRI) method, the projections were used to distinguish between pitted and non-pitted olives . Effect of fruit position in the coil was tested and coil degree effects were noticed when projects were generated under dynamic conditions. Various belt speeds (up to 250mm/s) were tested and detection results were compared to static measurements. Higher classification errors were occurred at dynamic conditions compared to errors while olives were at rest.

  • PDF

Monitoring Posterior Cerebral Perfusion Changes With Dynamic Susceptibility Contrast-Enhanced Perfusion MRI After Anterior Revascularization Surgery in Pediatric Moyamoya Disease

  • Yun Seok Seo;Seunghyun Lee;Young Hun Choi;Yeon Jin Cho;Seul Bi Lee;Jung-Eun Cheon
    • Korean Journal of Radiology
    • /
    • v.24 no.8
    • /
    • pp.784-794
    • /
    • 2023
  • Objective: To determine whether dynamic susceptibility contrast-enhanced (DSC) perfusion magnetic resonance imaging (MRI) can be used to evaluate posterior cerebral circulation in pediatric patients with moyamoya disease (MMD) who underwent anterior revascularization. Materials and Methods: This study retrospectively included 73 patients with MMD who underwent DSC perfusion MRI (age, 12.2 ± 6.1 years) between January 2016 and December 2020, owing to recent-onset clinical symptoms during the follow-up period after completion of anterior revascularization. DSC perfusion images were analyzed using a dedicated software package (NordicICE; Nordic NeuroLab) for the middle cerebral artery (MCA), posterior cerebral artery (PCA), and posterior border zone between the two regions (PCA-MCA). Patients were divided into two groups; the PCA stenosis group included 30 patients with newly confirmed PCA involvement, while the no PCA stenosis group included 43 patients without PCA involvement. The relationship between DSC perfusion parameters and PCA stenosis, as well as the performance of the parameters in discriminating between groups, were analyzed. Results: In the PCA stenosis group, the mean follow-up duration was 5.3 years after anterior revascularization, and visual disturbances were a common symptom. Normalized cerebral blood volume was increased, and both the normalized time-topeak (nTTP) and mean transit time values were significantly delayed in the PCA stenosis group compared with those in the no PCA stenosis group in the PCA and PCA-MCA border zones. TTPPCA (odds ratio [OR] = 6.745; 95% confidence interval [CI] = 2.665-17.074; P < 0.001) and CBVPCA-MCA (OR = 1.567; 95% CI = 1.021-2.406; P = 0.040) were independently associated with PCA stenosis. TTPPCA showed the highest receiver operating characteristic curve area in discriminating for PCA stenosis (0.895; 95% CI = 0.803-0.986). Conclusion: nTTP can be used to effectively diagnose PCA stenosis. Therefore, DSC perfusion MRI may be a valuable tool for monitoring PCA stenosis in patients with MMD.

Development of Image Quality Enhancement of a Digital Camera with the Application of Exposure To The Right Exposure Method (ETTR 노출 방법을 활용한 디지털 카메라의 화질 향상)

  • Park, Hyung-Ju;Har, Dong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.8
    • /
    • pp.95-103
    • /
    • 2010
  • Raw files record luminance values corresponds to each pixel of a digital camera sensor. In digital imaging, controlling exposure to capture the first highlight stop is important on linear-distribution of raw file characteristic. This study sought to verify the efficiency of ETTR method and found the optimum over-exposure amount to maintain the first highlight stop to be the largest number of levels. This was achieved by over-exposing a scene with a raw file and converting it to under-exposure in a raw file converting software. Our paper verified the efficiency of ETTR by controlling the exposure range and ISOs. Throughout the results, if exposure increases gradually 6 steps, dynamic range is also increased. And it shows that the optimized exposure value is around + $1\frac{2}{3}$ stop over compared to the normal exposure with the high ISOs simultaneously. We compared visual noise value at $1\frac{2}{3}$ stop to the normal exposure visual noise. Based on the normal exposure's visual noise, we can confirm that visual noise decrement is increased by increasing ISOs. In this experimental result, we confirm that overexposure about + $1\frac{2}{3}$ stop is the optimum value to make the widest dynamic range and lower visual noise in high ISOs. Based on the study results, we can provide the effective ETTR information to consumers and manufacturers. This method will contribute to the optimum image performance in maximizing dynamic range and minimizing noise in a digital imaging.

High Dynamic Range Image Display Combining Weighted Least Squares Filtering with Color Appearance Model (가중 최소자승 필터링과 색 표현 모델을 결합한 넓은 동적 영역 이미지 표현)

  • Piao, Mei-Xian;Lee, Kyung-Jun;Wee, Seung-Woo;Jeong, Jechang
    • Journal of Broadcast Engineering
    • /
    • v.21 no.6
    • /
    • pp.920-928
    • /
    • 2016
  • Recently high dynamic range imaging technique is hot issue in computer graphic area. We present a progressive tone mapping algorithm, which is based on weighted least squares optimization framework. Our approach combines weighted least squares filtering with iCAM06 model. To show more perceptual high dynamic range images in conventional display, we decompose high dynamic range image into base layers and detail layers. The base layers are obtained by using weighted least squares filter. Then, we adopt chromatic adaption function and non-linear compression function to deal with base layers. Only the base layers reduce contrast, and preserving detail. The image quality assessment shows that our tone mapped image is more similar to original high dynamic range image. Moreover, the subjective result shows our algorithm produces more reliable and pleasing image.

Dosimetric Verification for Primary Focal Hypermetabolism of Nasopharyngeal Carcinoma Patients Treated with Dynamic Intensity-modulated Radiation Therapy

  • Xin, Yong;Wang, Jia-Yang;Li, Liang;Tang, Tian-You;Liu, Gui-Hong;Wang, Jian-She;Xu, Yu-Mei;Chen, Yong;Zhang, Long-Zhen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.3
    • /
    • pp.985-989
    • /
    • 2012
  • Objective: To make sure the feasibility with $^{18F}FDG$ PET/CT to guided dynamic intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma patients, by dosimetric verification before treatment. Methods: Chose 11 patients in III~IVA nasopharyngeal carcinoma treated with functional image-guided IMRT and absolute and relative dosimetric verification by Varian 23EX LA, ionization chamber, 2DICA of I'mRT Matrixx and IBA detachable phantom. Drawing outline and making treatment plan were by different imaging techniques (CT and $^{18F}FDG$ PET/CT). The dose distributions of the various regional were realized by SMART. Results: The absolute mean errors of interest area were $2.39%{\pm}0.66$ using 0.6cc ice chamber. Results using DTA method, the average relative dose measurements within our protocol (3%, 3 mm) were 87.64% at 300 MU/min in all filed. Conclusions: Dosimetric verification before IMRT is obligatory and necessary. Ionization chamber and 2DICA of I'mRT Matrixx was the effective dosimetric verification tool for primary focal hyper metabolism in functional image-guided dynamic IMRT for nasopharyngeal carcinoma. Our preliminary evidence indicates that functional image-guided dynamic IMRT is feasible.