• Title/Summary/Keyword: Dynamic contrast enhancement

Search Result 99, Processing Time 0.027 seconds

A Nonlinear Image Enhancement Method for Digital Mammogram (디지털 맘모그램을 위한 비선형 영상 향상 방법)

  • Jeon, Geum-Sang;Kim, Sang-Hee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.1
    • /
    • pp.6-12
    • /
    • 2013
  • Mammography is the most common technique for the early detection of breast cancer. To diagnose correctly and treat of breast cancer efficiently, many image enhancement methods have been developed. This paper presents a nonlinear image enhancement method for the enhancement of digital mammogram. The proposed method is composed of a nonlinear function for brightness improvement and a nonlinear filter for contrast enhancement. The nonlinear function improves the brightness of dark area and extends the dynamic range of bright area, and the nonlinear filter efficiently enhances the specific regions and objects of the mammogram. The final enhanced image was obtained by combining the processed image with the nonlinear function and the filtered image with the nonlinear filter. The proposed nonlinear image enhancement method was confirmed the enhanced performance comparing with other existing methods.

Gamma Correction for Local Brightness and Detail Enhancement of HDR Images (HDR 영상의 지역적 밝기 및 디테일 향상을 위한 감마 보정 기법)

  • Lee, Seung-Yun;Ha, Ho-Gun;Song, Kun-Woen;Ha, Yeong-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.5
    • /
    • pp.837-847
    • /
    • 2016
  • Tone mapping for High Dynamic Range(HDR) image provides matching human visual perception between real world scene and displayable devices. Recently, a tone mapping algorithm based on localized gamma correction is proposed. This algorithm is using human visual properties of contrast and colorfulness with background intensity, generating a weight map for gamma correction. However, this method have limitations of controlling enhancement region as well as generating halo artifacts caused by the weight map construction. To overcome aforementioned limitations, proposed algorithm in this paper modifies previous weight map, considering base layer intensity of input luminance channel. By determining enhancement region locally and globally based on base layer intensity, gamma values are corrected accordingly. Therefore, proposed algorithm selectively enhances local brightness and controls strength of edges. Subjective evaluation using z-score shows that our proposed algorithm outperforms the conventional methods.

Color Image Enhancement Based on Color Constancy (칼라 항상성에 기초한 칼라영상 향상)

  • 배성호;김정엽;권갑현;하영호
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.5
    • /
    • pp.103-108
    • /
    • 1993
  • An image can be largely corrupted by the ambient illuminant, so that the image enhancement to restory natural color without respect to the ambient illuminant is needed. It this paper, a new color image enhancement technique based on color constancy is proposed. To enhance the image quality, higher volues of contrast and saturation are preferred, but their excessive values make an image unnatural. Since the color constancy processing preserves only hue, while reducing the dynamic range of lightness and saturation,the technique is needed in order to compensate this phenomenon. The proposed method transforms and increases lightness and saturation simultaneously to avoid the complexity in the related transformation by analyzing the relationship between the RGB and modified IHS coordinate system.

  • PDF

CT Scan Findings of Rabbit Brain Infection Model and Changes in Hounsfield Unit of Arterial Blood after Injecting Contrast Medium (토끼 뇌감염 모델의 CT 소견과 조영제 주입 후 동맥혈의 Hounsfield Unit의 변화)

  • Ha, Bon-Chul;Kwak, Byung-Kook;Jung, Ji-Sung
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.270-279
    • /
    • 2012
  • This paper explores CT findings of a rabbit brain infection model injected with Escherichia coli and investigates the changes in Hounsfield unit (HU) of arterial blood over time. The brain infection model was produced by injecting E. coli $1{\times}10^7$ CFU/ml, 0.1 ml through the burr hole in the calvarium; 2~3 mm in depth from the dura mater, and contrast-enhanced CT, dynamic CT and arterial blood CT images were gained. It was found that various brain infections such as brain abscess, ventriculitis and meningitis. The CT image of brain abscess showed a typical pattern which the peripheral area was strongly contrast-enhanced while the center was weakly contrast-enhanced. The CT image of ventriculitis showed a strong contrast-enhancement along the lateral ventricle wall, and the CT image of meningitis showed a strong contrast-enhancement in the area between the telencephalon and the diencephalon. In dynamic CT images, the HU value of the infection core before injecting contrast medium was $31.01{\pm}3.55$. By 10 minutes after the injection, the value increased gradually to $40.36{\pm}3.76$. The HU value in the areas of the marginal rim where was hyper-enhanced showed $47.23{\pm}3.12$ before contrast injection, and it increased to $63.59{\pm}3.31$ about 45 seconds after the injection. In addition, the HU value of the normal brain tissue opposite to the E. coli. injected brain was $39.01{\pm}3.24$ before the injection, but after the contrast injection, the value increased to $49.01{\pm}4.29$ in about 30 seconds, and then it showed a gradual decline. In the arterial blood CT, the HU value before the contrast injection was $87.78{\pm}6.88$, and it increased dramatically between 10 to 30 seconds until it reached a maximum value of $749.13{\pm}98.48$. Then it fell sharply to $467.85{\pm}62.98$ between 30 seconds to 45 seconds and reached a plateau by 60 seconds. Later, the value showed a steady decrease and indicated $188.28{\pm}25.03$ at 20 minutes. Through this experiment, it was demonstrated that the brain infection model can be produced by injecting E. coli., and the characteristic of the infection model can be well observed with contrast-enhanced CT scan. The dynamic CT scan showed that the center of the infection was gradually contrast-enhanced, whereases the peripheral area was rapidly contrast-enhanced and then slowly decreased. As for arterial blood, it increased significantly between 10 seconds to 30 seconds after the contrast medium injection and decreased gradually after reaching a plateau.

Dynamic MR Imaging in Gastric Cancer : Comparison Between Precontrast and Postcontrast Images (위암의 역동적 자기공명영상: 조영증강 전 후 영상의 비교)

  • 홍성환;한준구;장기현;최병인
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.130-134
    • /
    • 1997
  • Purpose: To analyze contrast-enhancement pattern of stomach cancer on dynamic MRI and to verify the efficacy of intravenous contrast agent in the evaluation of stomach cancer. Materials and Methods: Twelve patients with proven stomach cancer underwent dynamic MRI. By using l.OT scanner, we obtained precontrast FLASH images, and 30, 60, 90 second delay FLASH images after intravenous contrast injection. All patients ingested one liter of water and had intramuscular injection of Buscopan just before MR study. For quantitative analysis we measured signal to noise ratio (SiN) of stomach cancer on each image, and signal difference to noise ratio (SD/N) between cancer and intraluminal fluid, cancer and the pancreas. For qualitative analysis two radiologists evaluated lesion conspicuity on each image by grading system(grade 0, 1, 2, 3: poor, fair, good, excellent). Results: SiN of stomach cancer increased gradually by time(precontrast, 30, 60, 90 second delay: 38.7, 42.5, 57.4, 65.7). SD/N between cancer and intraluminal fluid significantly increased after contrast enhancement(l.24, 25.01, 39.30, 45.89). SD/Ns between cancer and the pancreas were 10.5, 9.33, 9.99, 10.66, respectively. In qualitative analysis, precontrast images were better than postcontrast images for delineation of stomach cancer. Postcontrast images showed clear endo-Iuminal side of stomach cancer, but outer margin of stomach cancer was more distinct on precontrast images. Conclusion: Precontrast MR images are better than postcontrast MR images in the depiction of stomach cancer. Intravenous contrast agent is not imperative in the evaluation of stomach cancer.

  • PDF

Emerging Role of Hepatobiliary Magnetic Resonance Contrast Media and Contrast-Enhanced Ultrasound for Noninvasive Diagnosis of Hepatocellular Carcinoma: Emphasis on Recent Updates in Major Guidelines

  • Tae-Hyung Kim;Jeong Hee Yoon;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • v.20 no.6
    • /
    • pp.863-879
    • /
    • 2019
  • Hepatocellular carcinoma (HCC) can be noninvasively diagnosed on the basis of its characteristic imaging findings of arterial phase enhancement and portal/delayed "washout" on computed tomography (CT) and magnetic resonance imaging (MRI) in cirrhotic patients. However, different specific diagnostic criteria have been proposed by several countries and major academic societies. In 2018, major guideline updates were proposed by the Association for the Study of Liver Diseases, European Association for the Study of the Liver (EASL), Korean Liver Cancer Association and National Cancer Center (KLCA-NCC) of Korea. In addition to dynamic CT and MRI using extracellular contrast media, these new guidelines now include magnetic resonance imaging (MRI) using hepatobiliary contrast media as the first-line diagnostic test, while the KLCA-NCC and EASL guidelines also include contrast-enhanced ultrasound (CEUS) as the second-line diagnostic test. Therefore, hepatobiliary MR contrast media and CEUS will be increasingly used for the noninvasive diagnosis and staging of HCC. In this review, we discuss the emerging role of hepatobiliary phase MRI and CEUS for the diagnosis of HCC and also review the changes in the HCC diagnostic criteria in major guidelines, including the KLCA-NCC practice guidelines version 2018. In addition, we aimed to pay particular attention to some remaining issues in the noninvasive diagnosis of HCC.

Accuracy of Live Fluoroscopy to Detect Intravascular Injection During Lumbar Transforaminal Epidural Injections

  • Lee, Min-Hye;Yang, Kyung-Seung;Kim, Young-Hoon;Jung, Hyun-Do;Lim, Su-Jin;Moon, Dong-Eon
    • The Korean Journal of Pain
    • /
    • v.23 no.1
    • /
    • pp.18-23
    • /
    • 2010
  • Background: Complications following lumbar transforaminal epidural injection are frequently related to inadvertent vascular injection of corticosteroids. Several methods have been proposed to reduce the risk of vascular injection. The generally accepted technique during epidural steroid injection is intermittent fluoroscopy. In fact, this technique may miss vascular uptake due to rapid washout. Because of the fleeting appearance of vascular contrast patterns, live fluoroscopy is recommended during contrast injection. However, when vascular contrast patterns are overlapped by expected epidural patterns, it is hard to distinguish them even on live fluoroscopy. Methods: During 87 lumbar transforaminal epidural injections, dynamic contrast flows were observed under live fluoroscopy with using digital subtraction enhancement. Two dynamic fluoroscopy fluoroscopic images were saved from each injection. These injections were performed by five physicians with experience independently. Accuracy of live fluoroscopy was determined by comparing the interpretation of the digital subtraction fluoroscopic images. Results: Using digital subtraction guidance with contrast confirmation, the twenty cases of intravascular injection were found (the rate of incidence was 23%). There was no significant difference in incidence of intravascular injections based either on gender or diagnosis. Only five cases of intravascular injections were predicted with either flash or aspiration of blood (sensitivity = 25%). Under live fluoroscopic guidance with contrast confirmation to predict intravascular injection, twelve cases were predicted (sensitivity = 60%). Conclusions: This finding demonstrate that digital subtraction fluoroscopic imaging is superior to blood aspiration or live fluoroscopy in detecting intravascular injections with lumbar transforaminal epidural injection.

Radiologic Findings of Renal Oncocytomas (신장 호산성과립세포종의 영상의학적 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.26 no.1
    • /
    • pp.30-37
    • /
    • 2009
  • Purpose : To radiologically differentiate renal oncocytoma from other renal solid tumors, we analyzed and characterized, retrogradely, radiologic findings of renal oncocytomas. Materials and Methods : Radiologic findings of pathologically proven renal oncocytoma were analyzed in 9 patients. CT was performed in all patients, ultrasonography in 4 patients and MRI in 3 patients.(51) Results : On ultrasonography, the echogenicity of the mass was slightly more hyperechoic than normal renal parenchyma in all 4 cases. Two cases were homogeneous and the remaining two cases were relatively homogeneous. On CT, all 8 cases showed iso-density to slightly low density compared to normal renal parenchyma and 5 cases were homogeneous but the central portion of the mass was of a slightly lower density than the peripheral portion in 3 cases. All six cases had an arterial phase scan and were heterogeneously enhanced. An irregular, lower-enhancing portion was found in the central portion of the mass. Segmental inversion of contrast enhancement was found in 5 of 6 cases that had a dynamic enhancement study. On MR T1-weighted imaging, the mass was of iso-signal intensity to normal renal parenchyma and the central portion of the mass had a slightly hypo-signal intensity than the peripheral portion. On T2-weighted imaging, 2 cases were heterogeneous; the peripheral portion was of low signal intensity and central portion was of higher signal intensity than normal renal parenchyma. One case was relatively homogeneous and showed a slightly lower signal intensity than that of normal parenchyma, except for a central small portion showing high signal intensity. For 2 cases that had a dynamic study, a segmental inversion of contrast enhancement was noted. Conclusion : Renal oncocytoma is seen as a well-marginated solid mass lesion. On enhanced scans it is heterogeneously enhanced and segmental inversion of contrast enhancement may be seen. The possibility of oncocytoma can be suggested in cases showing these radiologic findings.

  • PDF

Optimal Phase of Dynamic Computed Tomography for Reliable Size Measurement of Metastatic Neuroendocrine Tumors of the Liver: Comparison between Pre- and Post-Contrast Phases

  • Huh, Jimi;Park, Jisuk;Kim, Kyung Won;Kim, Hyoung Jung;Lee, Jong Seok;Lee, Jong Hwa;Jeong, Yoong Ki;Shinagare, Atul B.;Ramaiya, Nikhil H.
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1066-1076
    • /
    • 2018
  • Objective: The reliability of size measurements of liver metastases from neuroendocrine tumors (NETs) on contrast-enhanced computed tomography (CT) phases made by different readers may be hampered due to transient, variable rim enhancement in arterial phase (AP) or portal venous phase (PVP) images. We aimed to assess the reliability of tumor size measurements in pre- and post-contrast scans. Materials and Methods: The study coordinator selected target lesions according to Response Evaluation Criteria in Solid Tumors 1.1 guidelines in 44 consecutive patients with pathologically confirmed NET liver metastases. Two blinded readers measured the longest diameters of target lesions on pre-contrast, AP, and PVP images twice with a 4-week interval. Inter- and intra-observer agreements were evaluated using Bland-Altman plots and 95% limit of agreement (LOA) calculations. Results: Of the 79 target lesions (approximate mean size of 3 cm), 45 showed rim enhancement. Inter-observer agreement assessed based on LOA was highest in pre-contrast CT images (-6.1-5.7 mm), followed by PVP (-7.9-7.1 mm) and AP (-8.5-7.4 mm) images. Intra-observer agreement showed the same trend: -2.8-2.9 mm and -2.9-2.9 mm for readers 1 and 2, respectively, on pre-contrast CT, -2.8-2.9 mm and -3.0-3.2 mm, respectively, on PVP, and -3.2-4.2 mm and -3.4-3.2 mm, respectively, on AP images. Mean tumor diameters differed significantly among the phases in the following increasing order: pre-contrast CT, PVP, and AP images. Conclusion: There was better inter- and intra-observer agreement in size measurements of NET liver metastases on pre-contrast scans than on AP and PVP scans. Pre-contrast CT may be the optimal for measuring NET liver metastases if its accuracy is proven.

A Parametric Image Enhancement Technique for Contrast-Enhanced Ultrasonography (조영증강 의료 초음파 진단에서 파라미터 영상의 개선 기법)

  • Kim, Ho Joon;Gwak, Seong Hoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.3 no.6
    • /
    • pp.231-236
    • /
    • 2014
  • The transit time of contrast agents and the parameters of time-intensity curves in ultrasonography are important factors to diagnose various diseases of a digestive organ. We have implemented an automatic parametric imaging method to overcome the difficulty of the diagnosis by naked eyes. However, the micro-bubble noise and the respiratory motions may degrade the reliability of the parameter images. In this paper, we introduce an optimization technique based on MRF(Markov Random Field) model to enhance the quality of the parameter images, and present an image tracking algorithm to compensate the image distortion by respiratory motions. A method to extract the respiration periods from the ultrasound image sequence has been developed. We have implemented the ROI(Region of Interest) tracking algorithm using the dynamic weights and a momentum factor based on these periods. An energy function is defined for the Gibbs sampler of the image enhancement method. Through the experiments using the data to diagnose liver lesions, we have shown that the proposed method improves the quality of the parametric images.