• Title/Summary/Keyword: Dynamic calibration

Search Result 234, Processing Time 0.022 seconds

Measurement of the Time Constant of Industrial Platinum Resistance Thermometers (산업용 백금저항온도계의 시정수 측정)

  • Kim, Yong-Gyoo;Kim, Sook-Hyang;Yang, In-Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.11
    • /
    • pp.41-46
    • /
    • 2009
  • We present experimental data on the time response behavior of industrial platinum resistance thermometers (IPRT) to help with the selection of proper sensors in industry and research laboratories. Time constants of IPRTs were measured using a method specified in ASTM standards. Two different sensors of different protecting sheath diameters were tested in air, water and silicon oil at temperatures from $0^{\circ}C$ to $200^{\circ}C$. The time constant was the smallest in water and the highest in air. As the test temperature increased, time constants tended to decrease at all heat conducting media. For different diameters of sheath of IPRT at the same temperature, it was found that the IPRT of larger diameter showed higher time constant in air, but the opposite dependence was observed in water and oil. From the measured results, it was suggested that the sensor diameter and heat conducting medium should be considered if one wants to select proper thermometer to measure the dynamic temperature change in industry and research area.

Seismic reliability evaluation of steel-timber hybrid shear wall systems

  • Li, Zheng;He, Minjuan;Lam, Frank;Zhou, Ruirui;Li, Minghao
    • Earthquakes and Structures
    • /
    • v.13 no.3
    • /
    • pp.289-297
    • /
    • 2017
  • This paper presents seismic performance and reliability evaluation on steel-timber hybrid shear wall systems composed of steel moment resisting frames and infill light frame wood shear walls. Based on experimental observations, damage assessment was conducted to determine the appropriate damage-related performance objectives for the hybrid shear wall systems. Incremental time-history dynamic analyses were conducted to establish a database of seismic responses for the hybrid systems with various structural configurations. The associated reliability indices and failure probabilities were calculated by two reliability methods (i.e., fragility analysis and response surface method). Both methods yielded similar estimations of failure probabilities. This study indicated the greatly improved seismic performance of the steel-timber hybrid shear wall systems with stronger infill wood shear walls. From a probabilistic perspective, the presented results give some insights on quantifying the seismic performance of the hybrid system under different seismic hazard levels. The reliability-based approaches also serve as efficient tools to assess the performance-based seismic design methodology and calibration of relative code provisions for the proposed steel-timber hybrid shear wall systems.

On-Line Monitoring of Low Biochemical Oxygen Demand Through Continuous Operation of a Mediator-Less Microbial Fuel Cell

  • MOON, HYUN-SOO;CHANG, IN-SEO;JANG, JAE-KYUNG;KIM, KYUNG-SHIK;LEE, JI-YOUNG;LOVITT, ROBERT W.;KIM, BYUNG-HONG
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.192-196
    • /
    • 2005
  • Abstract Oligotrophic microbial fuel cells (MFCs) were tested for the continuous monitoring of low biochemical oxygen demand (BOD) by using artificial wastewater, containing glucose and glutamate, as check solution. Ten times diluted trace mineral solution was used to minimize the background current level, which is generated from the oxidation of nitrilotriacetate used as a chelating agent. The feeding rate of 0.53 ml/min could increase the sensitivity from 0.16 to 0.43 ${\mu}$A/(mg BOD/l) at 0.15 ml/min. The dynamic linear range of the calibration curve was between 2.0 and 10.0 mg BOD/l, and the response time to the change of 2 mg BOD/l was about 60 min. The current signal from an oligotroph-type MFCs increased with the increase in salts concentration, and the salt effect could be eliminated by 50 mM phosphate buffer.

Modeling Daily Streamflow in Wastewater Reused Watersheds Using System Dynamics (시스템 다이내믹스를 이용한 하수재이용 유역의 일유출량 모의)

  • Jeong, Han Seok;Seong, Choung Hyun;Park, Seung Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.45-53
    • /
    • 2014
  • This study presents a system dynamics modeling approach to simulate daily streamflow in a watershed including wastewater treatment plant which contributes to irrigation water supply. The conceptual system dynamics model considering the complex and dynamic hydrological processes in the watershed was developed. The model was calibrated and validated each for two years based on observed flow data. Model performances in terms of $E_{NS}$, RSR, PBIAS, and $R^2$ were 0.64, 0.60, -3.6 %, and 0.64 for calibration period, and 0.66, 0.58, -2.6 %, and 0.66 for validation period, respectively, showing an applicability on generating the daily streamflow. System dynamics modeling approach could help better understand the hydrological behavior of the watershed being reused wastewater for agriculture, by providing graphical dynamics of the hydrological processes as well as conventional rainfall-runoff model results.

Visualization of Oil Behavior in Piston Land Region (피스톤 랜드 부에서 오일거동의 가시화)

  • 민병순
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.5
    • /
    • pp.105-113
    • /
    • 2000
  • In order to clarify the final process of oil consumption, the distribution and flow of oil through each ring were visualized by induced fluorescence method. Motoring and firing test were performed in a single cylinder research engine with transparent cylinder liner. The appropriate calibration techniques were used to solve the unstability of induced light intensity as well as to know the relation of the oil film thickness and output signal. Oil behavior was also observed at dynamic state by high speed CCD camera. By analyzing the oil film thickness converted from the photographed image, it was observed that the main route of oil transport through each ring is the end gap under the usual operating condition, low engine speed and low load condition. Oil film thickness is observed to be irregular and tend to move in a body horizontally at a given piston land. And it is also found that oil flows through oil ring gap so quickly that it can be observed in a single cycle, but it flows so slowly through top and 2nd compression rings that it takes quite a long time to detect the flow.

  • PDF

The Measurement of the Dynamics Performance of a Linear Induction Motor (유도형(誘導型) 리니어모터의 동특성(動特性) 계측(計測))

  • Kim, I.K.;Chung, H.G.;Park, C.I.;Park, H.C.;Kim, B.S.;Park, S.C.;Chung, H.H.;Kim, Y.M.;Jang, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.223-225
    • /
    • 1994
  • In these days, it is widely applications of Linear Induction Motor(LIM) that used propulsion system of maglev and LIM Car. elevator. conveyor system, servo system, etc. The calibration method for, performance of LIM is more difficult than static state of one. Then we made testing system to measurement for dynamic performance of LIM and deal with data acquisition board on PC system. We try to get for the data measuring that is thrust force, braking force versus speed(r.p.m. or time) and current, voltage, frequency versus speed.

  • PDF

Analysis of Saikosaponins by HPLC with Photoreduction Fluorescence Detection (광반응 HPLC를 이용한 시호 사포닌의 분석)

  • Shin, Young-Geun;Cho, Kyung-Hee;Kwon, Soo-Jin;Do, Young-Mi;Hwang, Gwi-Seo;Park, Jeong-Hill;Park, Man-Ki
    • YAKHAK HOEJI
    • /
    • v.40 no.1
    • /
    • pp.41-45
    • /
    • 1996
  • A high performance liquid chromatography using photoreduction fluorescence detection was described for the analysis of saikosaponins. Saikosaponins were separated on an $NH_2$ column using acetonitrile and aqueous 2-tert-butylanthraquinone(t-BAQ) as mobile phase. Column effluent was passed through a 40cm PTFE capillary tube coiled around a 10W UV lamp to reduce t-BAQ to a highly fluorescent dihydroxyanthracene derivative which was detected by a fluorescence detector. The optimal concentration of t-BAQ was found to be $6{\times}10^{-5}M$ and the optimal reaction time to be 2 seconds. The detection limit for saikosaponin a and d by this method was found to be about 280ng and 80ng. The dynamic linear range was over two orders and the correlation coefficient of the calibration curve of them was 0.998.

  • PDF

A Study on the Application of Phased Array Ultrasonic Testing to Main Steam Line in Nuclear Power Plants (원전 주증기배관 웰더렛 용접부 위상배열초음파검사 적용연구)

  • Lee, Seung-Pyo;Kim, Jin-Hoi
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.40-47
    • /
    • 2011
  • KSNPs(Korea Standard Nuclear Power Plant) have been applied the break exclusion criteria to the high energy lines passing through containment penetration area to ensure that piping failures would not cause the loss of containment isolation function, and to reduce the resulting dynamic effects. Systems with the criteria are the Main Steam system, Feed Water system, Steam Generator Blowdown system, and Chemical & Volume Control system. In accordance with FSAR(Final Safety Analysis Report), a 100% volumetric examination by augmented in-service inspection of all pipe welds appled the break exclusion criteria is required for the break exclusion application piping. However, it is difficult to fully satisfy the requirements of inspection because 12", 8" and 6" weldolet weldments of Main Steam pipe line have complex structural shapes. To resolve the difficulty on the application of conventional UT(Ultrasonic Testing) technique, realistic mock-ups and UT calibration blocks were made. Simulations of conventional UT were performed utilizing CIVA, a commercial NDE(Nondestructive Examination) simulation software. Phased array UT experiments were performed through mock-up including artificial notch type flaws. A phased array UT technique is finally developed to improve the reliability of ultrasonic test at main steam line pipe to 12", 8" and 6" branch connection weld.

Design and Fabrication of K-band Attenuation Standard (K-대역 감소량 표준기의 설계 및 제작)

  • Lee Joo-Gwang;Kim Jeong-Hwan;Kang Jin-Seob;Kang Tae-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.107
    • /
    • pp.387-392
    • /
    • 2006
  • In this paper, measurement scheme and uncertainty estimation of the K-band attenuation standard fitted with 3.5 mm coaxial connectors are described. The standard comprises a build-up chain of four steps of power ratio mea-surement and operates in the frequency range of 18 GHz to 26.5 GHz. The nominal attenuation of each step is around 20 dB and total dynamic range is 80 dB. The expanded uncertainty of the overall system is 0.01 dB at the confidence level of approximately 95%.

System Strategies for Time-Domain Emission Measurements above 1 GHz

  • Hoffmann, Christian;Slim, Hassan Hani;Russer, Peter
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.4
    • /
    • pp.304-310
    • /
    • 2011
  • The application of time-domain methods in emission measurement instruments allows for a reduction in scan time by several orders of magnitude and for new evaluation methods to be realized such as the real-time spectrogram to characterize transient emissions. In this paper two novel systems for time-domain EMI measurements above 1 GHz are presented. The first system combines ultra-fast analog-to-digital-conversion and real-time digital signal processing on a field-programmable-gate-array (FPGA) with ultra-broadband multi-stage down-conversion to enable measurements in the range from 10 Hz to 26 GHz with high sensitivity and full-compliance with the requirements of CISPR 16-1-1. The required IF bandwidths were added to allow for measurements according to MIL-461F and DO-160F. The second system realizes a system of time-interleaved analog-to-digital converters (ADCs) and has an upper bandwidth limit of 4 GHz. With the implementation of an automatic mismatch calibration, the system fulfills CISPR 16-1-1 dynamic range requirements. Measurements of the radiated emissions of electronic consumer devices and household appliances like the non-stationary emissions of a microwave oven are presented. A measurement of a personal computer's conducted emissions on a power supply line according to DO-160F is given.